  • Axis Communications A 120 V AC - page 1

    INSTALLATION GUIDE ENGLISH DEUTSC H ITALIANO ESPAÑOL FRAN Ç AIS AXIS Electrical Safety Kit A 120 V AC AXIS Electrical Safety Kit B 230 V AC ...

  • Axis Communications A 120 V AC - page 2

    Electrical Safety: Low Voltage Directive (LVD) Europe - This equipment complies with the Low Voltage Directive 2006/95/EC. Safety For safety informati on regarding the components of this kit, see Technical Specifications, o n page 15. Equipment Modifications This equipment must be installed and used in strict acco rdance with th e instructions give ...

  • Axis Communications A 120 V AC - page 3

    ENGLISH Safeguards Please read through this Installation Guide carefully be fore installing the Axis product. Ke ep the Installa tion Guide for further reference . • Store the Axis product in a dry and ventilated environment. • Avoid exposing the Axis product to vibration, shocks or heavy pressure. Do not install the product on unstable bracket ...

  • Axis Communications A 120 V AC - page 4

    ...

  • Axis Communications A 120 V AC - page 5

    AXIS Electr ical Safety Kit A/B Page 5 ENGLISH AXIS Electrical Safety Kit A/B Installation Guide This Installation Guide provides instru ctions for installing AXIS Electrical Safety Kit A 120 V AC and AXIS Electr ical Safety Kit B 230 V AC in AXIS T98A-VE Surveillance Cabinet Series. The purpose of this kit is to prov ide surge protection, a fuse a ...

  • Axis Communications A 120 V AC - page 6

    Page 6 AXIS Electr ical Safet y Kit A/B Hardware Overview In this document PE, Protective Earth, and Ground are referred to as ground. 1 2 3 4 5 7 6 1 MCB fuse 4 A (Circuit bre aker) 2 Surge protector 4 A 3 Terminal block – feed-through (blue) 4 Terminal block – ground (green/yellow) 5 Terminal block – ground (green/yellow) 6 Door switch 7 Do ...

  • Axis Communications A 120 V AC - page 7

    AXIS Electr ical Safety Kit A/B Page 7 ENGLISH Connection Diagram • If an external protective bonding wire is used it is recom- mended to have a miminum area of 6 mm 2 (AWG 10) for indoor use and a minimum area of 10 mm 2 (AWG 8) for outdoor use. • The circuitry shall be connected to an external double pole cir- cuit breaker in the building ins ...

  • Axis Communications A 120 V AC - page 8

    Page 8 AXIS Electr ical Safet y Kit A/B • Check the surge protector after lig htning strikes and replace if required. See Replace the Surge Protector, on page 14. • An additional fuse may be required in regions with severe light- ning strikes. To preven t unwant ed triggering of the fuse, a higher rated fuse may replace th e 4 A MCB fuse, follo ...

  • Axis Communications A 120 V AC - page 9

    AXIS Electr ical Safety Kit A/B Page 9 ENGLISH Install the Devices • The electrical connections and conduit installat ions shall be made by a certified electricia n and in compliance with local regulations. • Risk of electric shock. The main s supply shall be disconnected during installation. • Keep the wires short but do not stretch them. Sh ...

  • Axis Communications A 120 V AC - page 10

    Page 10 AXIS Electrical Safety Kit A/B Example: AXIS Electrical Safety Kit A 120 V AC 1 0 L N PE 4 A 1 6 7 9 8 2 3 4 5 1 Circuit breaker 2 Surge protector 3 Terminal block – feed-through (blue) 4 Terminal block – ground (green/yellow) 5 Terminal block – ground (green/yellow) 6L L i n e c o n n e c t i o n 7 N Neutral connection 8 Ground conne ...

  • Axis Communications A 120 V AC - page 11

    AXIS Elect rical Safe ty Kit A/B Page 11 ENGLISH Example: AXIS Electrical Safety Kit B 230 V AC PE 1 0 LN 4 A 1 6 7 9 8 2 3 4 5 1 Circuit breaker 2 Surge protector 3 Terminal block – feed-through (blue) 4 Terminal block – ground (green/yellow) 5 Terminal block – ground (green/yellow) 6L L i n e c o n n e c t i o n 7 N Neutral connection 8 Gro ...

  • Axis Communications A 120 V AC - page 12

    Install the Door Swit ch The door switch included with the elec trical safety kit can be connected to the I/O port on a camera or an I/O device. See the camera’s Installation Guide and User Manual for information about connecting and configuring the camera’s I/O port. 1. Connect either of the connectors on the door switch cable to the common te ...

  • Axis Communications A 120 V AC - page 13

    AXIS Elect rical Safe ty Kit A/B Page 13 ENGLISH 4. If connecting to the I/O port on a camera, route the door switch cable through a cable gasket and at tach the cabl e gaske t to one of the cable holes in the cabinet door. 5. Secure the cable to the door using the supplied cable clip. 6. Connect the door switch cable to the I/O port on the camera ...

  • Axis Communications A 120 V AC - page 14

    Page 14 AXIS Electrical Safety Kit A/B Replace the Surge Protector The surge protector gets worn out by surges. The window on the surge protector shows the status of the device. 1. When the entire window is red, pull out the module and replace it. on res alarm on res alarm ...

  • Axis Communications A 120 V AC - page 15

    AXIS Elect rical Safe ty Kit A/B Page 15 ENGLISH Technical Specifications General Function/group Item Specifications General Environment In a cas ing for indoor or outdoor use Pollution Degree 2 Door switch Ap provals EN61058 UL1054 Operating conditions -40 ºC to +85 ºC (-40 ºF to 185 ºF) Humidity 15 – 10 0% RH Terminal blocks Approvals UL105 ...

  • Axis Communications A 120 V AC - page 16

    Page 16 AXIS Electrical Safety Kit A/B AXIS Electrical Safety Kit A 120 V AC Function/group Item Specifications Circuit breaker/fuse Rated current 4A at 30°C (8 6°F) Operating voltage Max 277 V AC Rated frequencey 50/60 Hz Rated short- circuit capacity 10 kA Tripping curve K Approvals IEC/EN 60947-2 UL 489 CSA 22.2 No. 5 Operating conditions -40 ...

  • Axis Communications A 120 V AC - page 17

    AXIS Elect rical Safe ty Kit A/B Page 17 ENGLISH AXIS Electrical Safety Kit B 230 V AC Function/group Item Specifications Circuit breaker/fuse Rated current 4A at 30°C (86°F) Operating voltage Max 253 V AC Rated frequencey 50/60 Hz Rated short- circuit capacity 6 kA Tripping curve C Approvals IEC/EN 60898-1 IEC/EN 60947-2 UL 1077 CSA 22.2 No. 235 ...

  • Axis Communications A 120 V AC - page 18

    Page 18 AXIS Electrical Safety Kit A/B Warranty For information about Axis’ produ ct warranty and thereto related information, see www.axis.com/warranty ...

  • Axis Communications A 120 V AC - page 19

    ...

  • Axis Communications A 120 V AC - page 20

    Installation Guide Ver.2.10 AXIS Electrical Safety Kit A/B Printed: October 2012 © Axis Communications AB, 2012 Part No. 48993 ...

Produzent Axis Communications Kategorie Marine Safety Devices

Dokumente, die wir vom Produzenten des Geräts Axis Communications A 120 V AC erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Axis Communications
- Bedienungsanleitungen A 120 V AC
- Produktkarten Axis Communications
- Informationsbroschüren
- oder Energieetiketten Axis Communications A 120 V AC
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Axis Communications A 120 V AC.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Axis Communications A 120 V AC, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Axis Communications A 120 V AC. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Axis Communications A 120 V AC ansehen.

Die komplette Bedienungsanleitung des Geräts Axis Communications A 120 V AC, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Axis Communications A 120 V AC hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Axis Communications A 120 V AC verständlich ist.

Eine gänzliche Bedienungsanleitung von Axis Communications sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Axis Communications A 120 V AC bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Axis Communications A 120 V AC befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Axis Communications A 120 V AC, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Axis Communications A 120 V AC - die uns die ersten Schritte während der Nutzung von Axis Communications A 120 V AC erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Axis Communications A 120 V AC hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Axis Communications A 120 V AC im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Axis Communications A 120 V AC?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Axis Communications A 120 V AC nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Axis Communications A 120 V AC hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)