    Operation/Reference Guide Touch Panels NXD-700Vi 7" Modero ® Wall/Flush Mount Touch Panel with Intercom Last Revised: 4/1/2011 ...

  • AMX nxd-700vi - page 2

    AMX Limited Warranty and Disclaimer This Limited W arranty and Disclaimer extends only to products purchased directly from AMX or an AMX Authorized Partn er which include AMX Dealers, Distributors, VIP’s or other AMX authorized entity . AMX warrants its products to be free of defects in material and workmanship under normal use for three (3) ye a ...

  • AMX nxd-700vi - page 3

    AMX Software License and Warranty Agreement • LICENSE GRANT . AMX grants to Licensee the non-exclusive right to use the AMX Software in the manner described in this License. The AMX Software is licensed, no t sold. This license does not grant Licensee the right to create derivative wor ks of t he AMX Software. The AMX Software consists of general ...

  • AMX nxd-700vi - page 4

    FCC Information This device complies with Part 15 of the FCC Rules. Operati on is subject to the fol lowing two condition s: (1) this device may not cause harmful interference, and (2) this device must accept any interference rece ived; in cluding in terference that may cause undesi red operation. Federal Communications Commission (FCC) Statement T ...

  • AMX nxd-700vi - page 5

    Table of Contents i NXD-700Vi 7" Modero® Wall/Flush Mo unt Touch Panel with Intercom Table of Contents Introduction .................. ...................................................................... ................ 1 Common Applicati on.. ............. ................ ............. ............. ................ ............. ....... ...

  • AMX nxd-700vi - page 6

    ii NXD-700Vi 7" Modero® Wall/Flush Mount Tou ch Panel with Intercom Table of Contents Ethernet/RJ-45 Port: Connections and Wiring ................... .................... ................. 37 USB Port: Connecting and Using Input Devices ................. ......................... ............ 37 Panel Calibration .. .......................... ...

  • AMX nxd-700vi - page 7

    Table of Contents iii NXD-700Vi 7" Modero® Wall/Flush Mo unt Touch Panel with Intercom Step 3: Confirm an d Upgrade the firmw are via the USB port ........ ................ ............... 65 Upgrading the Modero Firmware via Et hernet (IP Address) ................................ ... 67 Step 1: Prepare the Master for commu nication v ia an I ...

  • AMX nxd-700vi - page 8

    iv NXD-700Vi 7" Modero® Wall/Flush Mount Tou ch Panel with Intercom Table of Contents Checking imag e cache status .... ............. ............. ................ ............. ................ ........... 116 Password Setup Page ................... ................ ............. ................ ................. ............. .... 116 SIP ...

  • AMX nxd-700vi - page 9

    Table of Contents v NXD-700Vi 7" Modero® Wall/Flush Mo unt Touch Panel with Intercom @PHT .................. ............ ............ ............ ........... ............... ............ ............ ........... ........ .... ........ 136 @PPA ...... ............ ............ ............ .............. ............ ............ ........... ...

  • AMX nxd-700vi - page 10

    vi NXD-700Vi 7" Modero® Wall/Flush Mount Tou ch Panel with Intercom Table of Contents ^BSO .............. ........... ............ ............... ............ ........... ............ ............... ............ ......... .. ......... 155 ^BSP ............... ........... ............ ............... ............ ........... ............ ... ...

  • AMX nxd-700vi - page 11

    Table of Contents vii NXD-700Vi 7" Modero® Wall/Flush Mo unt Touch Panel with Intercom ADBEEP ....................... ............ ............... ........... ............ ............ ............... ........... .......... .. ........ 172 ?TXT ............. ............ ............ ............ .............. ............ ............ ..... ...

  • AMX nxd-700vi - page 12

    viii NXD-700Vi 7" Modero® Wall/Flush Mount Tou ch Panel with Intercom Table of Contents ^BBR ... ............ ........... ............... ............ ............ ........... ............... ............ ............ ........ ...... ...... 182 ^RAF ....................... ............ ............ ............ ........... ............... ... ...

  • AMX nxd-700vi - page 13

    Table of Contents ix NXD-700Vi 7" Modero® Wall/Flush Mo unt Touch Panel with Intercom ?PHN-LINESTATE ........... ............ .............. ............ ............... ............ ............ .............. ........... ... 189 ^PHN-PRIVACY ........... ............ ............... ........... ............ ............... ............ ..... ...

  • AMX nxd-700vi - page 14

    x NXD-700Vi 7" Modero® Wall/Flush Mount Tou ch Panel with Intercom Table of Contents ...

  • AMX nxd-700vi - page 15

    Introduction 1 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Introduction The NXD-700V i is an incredibly versatile user interf ace, combining a sleek, co mpact size, W all/Flush Mount flexibil ity and the ability to cre ate a high qual ity dig ital home/of fice intercom ne tw ork or to make/receiv e digital local, long dist ...

  • AMX nxd-700vi - page 16

    Introduction 2 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom These Color V ideo (CV) panels display NTSC/P AL/SEC AM video formats within variable sized windo ws. They include a b uilt-in microphone, speaker , audio/ headphone connector , and six NetLinx programmable pushbuttons ( available on N XD models only when mo unted ...

  • AMX nxd-700vi - page 17

    Introduction 3 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom The NXD-700V i comes with a standard silver bezel (FIG. 1), b ut the de vice is also av ailable with the optional Mystique-style bezel (FIG. 3 ). The NXXD-700V i may be ordered with the bezel already instal led, or the bezel may be purchased separately to update th ...

  • AMX nxd-700vi - page 18

    Introduction 4 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom NXD-700Vi Specifications The following table outlines th e specifications for the 7" W i descreen Modero panels. Product Specifications Dimensions (HWD): • NXA-RK7: metal rack-mount with black matte finish: (4 RU - rack units high) 6.97" x 19.0" x ...

  • AMX nxd-700vi - page 19

    Introduction 5 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Product Specifications (Cont.) Side Panel Components: Front setup access button: • Provides both access to the Setup and Calibration page and toggles the panel between a "sleep" or "wake" state. - When wired, "sleep" status means the ...

  • AMX nxd-700vi - page 20

    Introduction 6 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Product Specifications (Cont.) Operating / Storage Environment: • Operating T emperature: 0° C (32° F) to 40° C (104° F) • Operating Humidity: 20% - 85% RH • S torage T emper ature: -20° C (-4° F) to 60° C (140° F) • S torage H umidity: 5% - 85% RH ...

  • AMX nxd-700vi - page 21

    Introduction 7 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom NXD-700Vi Panels - Connector Layout FIG. 4 sho ws the layout of the connectors (located on the re ar of the base on the NXT and on the left side panel of the NXD panels). FIG. 4 Connector layout on th e NXD-700Vi touch panels PROGRAM ETHERN ET 10/1 00 A L 12VDC AUD ...

  • AMX nxd-700vi - page 22

    Introduction 8 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom ...

  • AMX nxd-700vi - page 23

    NXA-AVB/ETHERNET Breakout Box 9 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom NXA-AVB/ETHERNET Breakout Box The NXA-A VB/ETHERNET Brea kout Box (FIG. 5) is incl uded as part of the NXD -700V i Kit configuration ( panel and box ) but can be purchased as a separate access ory . This box facilitates the installation and distrib ...

  • AMX nxd-700vi - page 24

    NXA-AVB/ETHERNET Breakout Box 10 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Installing the NXA-AVB/ETHERNET A 12 VDC-compliant power supply can indirectly pro v ide po wer to a Modero panel by routing po wer through the NXA-A VB/ETHERNET Breakout Box. FIG. 6 shows a sa mple wiring configuratio n using both an indirect or ...

  • AMX nxd-700vi - page 25

    NXA-AVB/ETHERNET Breakout Box 11 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Wiring the NXA-AVB/ETHERN ET Connectors And Cables The inputs and outputs on the breakout box are separated into front and rear connect ors. The rear connectors are used to input external signals. The front connect ors are used to communicat e sig ...

  • AMX nxd-700vi - page 26

    NXA-AVB/ETHERNET Breakout Box 12 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Wiring the NXA-AVB/ETHERNET for Unbalanced Audio Most domestic audio equipment has unbalanced audio inputs and outputs. This means that the audio output (left, right, or mono) appears on a singl e wire, and is refe renced to "0 V" or &qu ...

  • AMX nxd-700vi - page 27

    NXD-700Vi Touch Panel Accessories 13 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom NXD-700Vi Touch Panel Accessories Overview The following section outli nes and describes the othe r AMX equipment av ailable for these touch panels. NXA-WC80211B/CF 802.11b Wireless Card (FG2255-03) These touch panels can connect to a wireless ...

  • AMX nxd-700vi - page 28

    NXD-700Vi Touch Panel Accessories 14 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom NXA-WC80211GCF 802.11g Wireless Card (FG2255-07) These panels can also connect to a wireless network using the ( optional) 802.11g W i-Fi CF card. This internal WIC (FIG. 2) can be purchased separately as a W i-Fi upgrade kit from AMX. This in ...

  • AMX nxd-700vi - page 29

    NXD-700Vi Touch Panel Accessories 15 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom This card works with compatible 802.11b/g W ire less Access Points s uch as the NXA-W AP200G ( which uses a default SSID of AMX ). Please follo w your particul ar W ireless Access Point’ s instruction manual for the correct procedures to set ...

  • AMX nxd-700vi - page 30

    NXD-700Vi Touch Panel Accessories 16 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom NXA-WC80211GCF Spec ifications (Cont.) Network Architecture: • Infrastructure mode (Client-to-Access Point) Operating Channels: • Using 802.1 1b & g communication: - 04: (Ch 10 - 13) - Fra n ce - 1 1: (Ch 1 - 1 1) - North America - 13: ...

  • AMX nxd-700vi - page 31

    NXD-700Vi Touch Panel Accessories 17 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom NXA-WC80211GCF Spec ifications (Cont.) T ransmit Out put Power: • 802.1 1b communication : 12 +-1 dBm (1, 2, 5.5, 1 1 Mbps) • 802.1 1g communication : 12 +-1 dBm (6, 9, 12, 18, 24, 36, 48, and 54 Mbps) Wireless LAN Security: • EAP-F AST ...

  • AMX nxd-700vi - page 32

    NXD-700Vi Touch Panel Accessories 18 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom ...

  • AMX nxd-700vi - page 33

    NXA-CFSP Compact Flash (FG2116-7x) 19 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom NXA-CFSP Compact Flash (FG2116-7x) Overview Every NXD-700V i Modero panel is shipped with a 128 MB Compact Flash card (NXA-CFSP). The NXA-CFSP Compact Flash card is factory programmed with specif ic panel fir mware and can be upgraded to se v ...

  • AMX nxd-700vi - page 34

    NXA-CFSP Compact Flash (FG2116-7x) 20 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom ...

  • AMX nxd-700vi - page 35

    Installation and Upgrade of the Inter nal NXD Components 21 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Installation and Upgrade of the Internal NXD Components Overview Upgrading the cards within the W all Mount panel in v o lves removing the rear plas tic outer housing (back box), removing the e xisting card, replacing it ...

  • AMX nxd-700vi - page 36

    Installation and Upgrade of the Inter nal NXD Components 22 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom 6. Carefully lift-of f the back box housing and angle it ov er to the side of the unit where the wires are connected to the circuit board. 7. Gently lay the back box to one side of the unit. This e xposes the internal ci ...

  • AMX nxd-700vi - page 37

    Installation and Upgrade of the Inter nal NXD Components 23 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom 6. T o complete the upgrade process, either upgrade the re maining wireless card (Step 3) or close and re- secure the enclosure using the procedures in Step 3: Close and Re-secur e the NXD P anel Enclosur e section on pa ...

  • AMX nxd-700vi - page 38

    Installation and Upgrade of the Inter nal NXD Components 24 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom ...

  • AMX nxd-700vi - page 39

    Installation 25 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Installation Overview NXD-700V i panels are installed into either a pre-w all surface (using a CB-TP7 conduit/w allbox) or a solid surface (using either solid surface or drywall scre ws). Installing the No-Button Trim Ring The NXD-700V i panel is shipped from AMX ...

  • AMX nxd-700vi - page 40

    Installation 26 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom 5. From along the internal surface of the Faceplate, r emov e the six b u ttons by gently bending each Button latch up and pulling the b utton outwards. 6. Remov e the pair of clear lig ht pipe strips by bendi ng the two black light pipe latches inwards and pullin ...

  • AMX nxd-700vi - page 41

    Installation 27 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom 5. From along the internal surface of the Faceplate, instal l the six b uttons by fi rmly inserting them into the button open ings until the Button latch secures the button in place (FIG. 9). 6. Install the pair of clear light pi pe strips by pushing light pipes o ...

  • AMX nxd-700vi - page 42

    Installation 28 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Pre-Wall Installation of the Conduit Box W all Mount panels (NXDs) are contained within an outer housing (back box). This back box is not remov ed when installing the NXD into a Con duit Box (CB-TP7). The back box is only removed to gain access for the replacement ...

  • AMX nxd-700vi - page 43

    Installation 29 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom 4. Thread the incoming power , RJ-45 audio/video, Ethernet, and USB wiring through the knockouts ( use of the left wiring knock out s are recommended wit h this installation ). Leav e enough slack in the wiring to acco mmodate an y re-posit ioning of the panel. 5. ...

  • AMX nxd-700vi - page 44

    Installation 30 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom 5. Disconnect the terminal end of the power cable from the connected power supply . 6. Carefully slide the main NXD-700V i unit ( B in FIG. 12) into the conduit box, so that all Mounting T abs lie flush against the conduit box ( C in FIG. 12). 7. Insert and secure ...

  • AMX nxd-700vi - page 45

    Installation 31 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom 3. Remove the F aceplate/bezel ( A in FIG. 14) from the main NXD unit ( B in FIG. 14) b y gripping the faceplate and pulling with ge ntle ou tward force. 4. Thread the incoming power , RJ- 45, Ethernet, USB, and any optio n al audio/video wiring (from their termin ...

  • AMX nxd-700vi - page 46

    Installation 32 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom 8. Install the three sets of drywall screws and e xpansio n clips into the three ov al notch lo cations along both sides of the main unit ( B in FIG. 14). 9. Carefully insert the main unit (with e xpansion clips) into the cutout until the Mounting T abs on the NXD ...

  • AMX nxd-700vi - page 47

    Installation 33 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Installing the NXD into a Fl at Surface using #4 screws Mounting scre ws (#4-40, includ ed) are secur ed through two sets of circul ar holes located at the left and right sides of the NXD-700V i. The most important thing to r emember when mounting the NXD W all Mo ...

  • AMX nxd-700vi - page 48

    Installation 34 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom 7. Disconnect the terminal end of the power cable from the power supply . 8. Carefully slide the main unit into the cutout un til the Mounting T abs of the NXD-700V i unit lie flush against the wall. 9. Insert and secure four #4-40 Mounti ng Scre ws (included) int ...

  • AMX nxd-700vi - page 49

    Installation 35 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom 4. T est the incoming wiring by connecting the panel connect ions to their terminal locations and applying power . V erify that the panel is rece iv ing po wer a nd functioning properly to pre vent repetition of the installat ion. 5. Disconnect the terminal end of ...

  • AMX nxd-700vi - page 50

    Installation 36 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Wiring a Power Connection T o use the 2-pin 3.5 mm mini-Phoen ix connector with a 12 VDC-complia nt po wer supply , the incoming PWR and GND wires from the external source must be connected to their co rresponding locations on the connector (FIG. 17). 1. Insert th ...

  • AMX nxd-700vi - page 51

    Installation 37 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Ethernet/RJ-45 Port: Connections and Wiring FIG. 18 describes the blink activity for the Ethernet 10/100 Base-T RJ-45 connector and cable. The Ethernet cable is connected to the rear of T able T op and side of the W all Mount panels. The following table li sts the ...

  • AMX nxd-700vi - page 52

    Installation 38 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom  If a USB mouse has been connected, a mouse cursor appears on the panel screen and its location corresponds to the mouse cursor posit ion sent by the external USB mouse.  If a USB ke yboard has been connected, only on-s creen keyboards and keypads will ...

  • AMX nxd-700vi - page 53

    Panel Calibration 39 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Panel Calibration Overview This section outlines the steps fo r calibrating the touch panel. It is r ecommended that you calibrate the panel befor e its initial use and after completing a firmwar e download. Modero panels are factory setup with specif ic demo ...

  • AMX nxd-700vi - page 54

    Panel Calibration 40 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Testing your Calibration 1. Press and hold down the on-screen Calibration b utton for 6 seconds to enter the Calibration T est page (FIG. 23). 2. Press anywhere on this page to confirm the on-screen crossh airs match your touch points. 3. If the crosshairs do ...

  • AMX nxd-700vi - page 55

    Configuring Communication 41 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Configuring Communication Overview Communication between the Modero panel and the Master is done using either USB or ETHERNET ( DHCP or Static IP ). Ethernet communication can be achiev ed through either a di rect connection (Ethernet) or through the ...

  • AMX nxd-700vi - page 56

    Configuring Communication 42 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Setting the Panel’ s Device Number In the Pr otected Setup page: 1. Press the Device Number f ield to open the Device Number ke ypad (FIG. 25). Enter a unique Device Number assignment for the panel , and press Done to return to the Pr otected Setup ...

  • AMX nxd-700vi - page 57

    Configuring Communication 43 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Configuring a Wireless Network Access When working with a wire less card, the f irst step is to conf igure wireless comm unication parameters within the W ireless Settings page. This page only configures the card to communi cate to a target W AP (such ...

  • AMX nxd-700vi - page 58

    Configuring Communication 44 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Security Settings section on page 46 f or detailed procedures to setup either a secure or unsecure connection. Wireless communic ation using a Static IP Address In the Pr otected Setup page: 1. Press the W irele ss Settings butt on (located on th e lo ...

  • AMX nxd-700vi - page 59

    Configuring Communication 45 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom  If a W AP is displayed in the list is not detected for 10 scans in a ro w it is then remov ed from the screen. In this way , a user can walk ar ound a building and see access points come and go as they mo ve in and out of range. 3. Sort the inf ...

  • AMX nxd-700vi - page 60

    Configuring Communication 46 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Step 2: Configure the Card’s Wireless Security Settings The second step to successfully setting up your wireless ca rd is to configure the W i reless Settings section of the W ireless Settings page. This se ction configures both the communicati on a ...

  • AMX nxd-700vi - page 61

    Configuring Communication 47 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom 3. From within the W ireless Security section, press the Open (Clear T ext) button to open the Open (Clear T ext) Settings dialog (FIG. 30). An Open security method does not utilize any en cryption methodology but does require that an SSID (alp ha-num ...

  • AMX nxd-700vi - page 62

    Configuring Communication 48 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Configuring the Mode ro’s wireless ca rd for secured access to a WAP200G After logging into the W AP200G, the default Status page appears within the web bro wser . These read-only values are "pulled" from some of the ot her user- configura ...

  • AMX nxd-700vi - page 63

    Configuring Communication 49 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Manually set SSID In the Pr otected Setup page: 1. Select Wireless Settings . 2. Locate the W ireless Security section (FIG. 3 2). 3. Press the Static WEP b utton to open the Static WEP Settings dialog (FIG. 33). 4. Press the SSID field and from the N ...

  • AMX nxd-700vi - page 64

    Configuring Communication 50 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom  As an example, if you use TECHPUBS as your SSID, you must match this word and the case within both the Network Name (SSID) f ield on the touch panel’ s Network Name SSID f ield and on the W AP’ s Basic W ir eless Conf iguration page. 5. T o ...

  • AMX nxd-700vi - page 65

    Configuring Communication 51 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom  As an exam ple, enter the w ord AMXPanel using a 128-bit hex digit encr yption. After pressing Done , the on-screen Current K ey f ield displays a long string of characters (separated by colons) which represents the encryption ke y equiv alent ...

  • AMX nxd-700vi - page 66

    Configuring Communication 52 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Configuring Multiple Wirel ess Moderos To Communicate To a Target WAP200G 1. For each co mmunicating t ouch panel, complete all of the st eps outlined within the pre vious Configu ring the Moder o’ s wir eless card fo r secur e d access to a W AP200 ...

  • AMX nxd-700vi - page 67

    Configuring Communication 53 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Prepare your PC for USB communicati on with the panel If you hav en’t already done so, do wnload and install th e latest versions of Ne tLinx Studio2 and TPDesign4 (from www .amx.com), and restart your PC. Configure the panel fo r USB communication ...

  • AMX nxd-700vi - page 68

    Configuring Communication 54 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom 8. Click Ye s to proceed with the driv er installation. Once the install ation is comple te, the pane l and PC are ready to communicate via USB. 9. Navigate back to the System Settings page. Configure a Vir tual NetLinx Maste r using NetLinx Stu dio A ...

  • AMX nxd-700vi - page 69

    Configuring Communication 55 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom 3. Click the Communication s Settings button t o open the Co mmunications Settings dialog. 4. Click the NetLinx Master radio b utton ( fr om the Platform Selection section ). 5. Click the V irtual Master radio button ( fr om the T ransport Conne ction ...

  • AMX nxd-700vi - page 70

    Configuring Communication 56 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Master Connection to a Virtua l Master via Ethernet Before beginning: 1. V erify the panel has been configured to communicate with the W ireless Access Point and v erify the signal strength quality bar graph is On. 2. Launch NetLinx Studio 2.x (defaul ...

  • AMX nxd-700vi - page 71

    Configuring Communication 57 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom 13. After the panel power s-up, pre ss and hold the two lo wer buttons on both sides of the display ( for 3 seconds ) to continue with the setup proces s and proceed to the Setup page. 14. Select Protected Setup > System Settings (located on th e l ...

  • AMX nxd-700vi - page 72

    Configuring Communication 58 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Using G4 Web Control to Interact with a G4 Panel The G4 W eb Control feature allows you to use a PC to interact with a G4 enable d panel via the web . This feature works in tandem with the new bro wser- capable NetLinx Securi ty firmw are update ( bui ...

  • AMX nxd-700vi - page 73

    Configuring Communication 59 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom 12. From the W eb Password ke yboard, enter a unique al pha-numeric string to b e assigned as the G4 Authentication se ssion password a ssociated with VNC web access of this panel. 13. Press Done after you are finished assigning the alpha-n umeric str ...

  • AMX nxd-700vi - page 74

    Configuring Communication 60 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom  If the Master has been previously conf igured for secur ed communication, cl ick OK to accept the AMX SSL certif icate ( if SSL is enabled ) and then enter a valid username and passw ord into the field s within the Login dialog. 4. Click OK to ...

  • AMX nxd-700vi - page 75

    Configuring Communication 61 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom 8. In some cases, you might get a Connection Details dialog (FIG. 46) requesting a VNC Server IP Address. This is the IP Address not the IP of the Master bu t of the target touch pane l. Depending on which method of communication you are using, it can ...

  • AMX nxd-700vi - page 76

    Configuring Communication 62 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom ...

  • AMX nxd-700vi - page 77

    Upgrading Modero F irmware 63 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Upgrading Modero Firmware Overview Before beginning the Upgrade process:  Setup and conf igure your NetLinx Master . Refer to the your particular NetL inx Master Instruction Manual for detailed setup procedures.  Calibrate and prepare the ...

  • AMX nxd-700vi - page 78

    Upgradin g Modero Fi rmware 64 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom 5. Press the Back button on the touch panel to retu rn to the Protected Setup page. 6. Press the on-screen Reboot button to both sa ve any changes and r estart the panel. Remember that the panel’ s connection type must be set to USB prior to reboo ...

  • AMX nxd-700vi - page 79

    Upgrading Modero F irmware 65 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom 6. Click the Edit Settings button ( on the Communications Settings dialo g ) to open the V irtual NetLinx Master Settings dialog (FIG. 47). 7. From within this dialog enter the System number (default is 1 ). 8. Click OK three times to close the open ...

  • AMX nxd-700vi - page 80

    Upgradin g Modero Fi rmware 66 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom 5. If the panel firmware being used is not current, do wnload the latest Kit file by f irst logging in to www .amx.com and then navig ate to T ech Center > Fir mware Files and from within the Moder o section of the web page locate your Modero pan ...

  • AMX nxd-700vi - page 81

    Upgrading Modero F irmware 67 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Upgrading the Modero Firmware via Ethernet (IP Address) Before beginning with this section, v erify that your panel is powered an d connected to the NetLinx Master through an Ethernet connection (direct or wireless). Step 1: Prepare the Maste r for c ...

  • AMX nxd-700vi - page 82

    Upgradin g Modero Fi rmware 68 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom 9. Place a checkmark within the Automatically Ping the Maste r Cont r oller to ensure availability radio box to make sure the Master is initially respond ing online before establ ishing full communication. 10. Click OK to close the current Ne w TCP/ ...

  • AMX nxd-700vi - page 83

    Upgrading Modero F irmware 69 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom 4. If the panel firmware bein g used is not current, do wnload t he latest Kit file by f irst logging in to www .amx.com and then navigate to T ech Center > Fi rmware Files and from withi n the Modero section of the web page locate your Moder o pa ...

  • AMX nxd-700vi - page 84

    Upgradin g Modero Fi rmware 70 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom ...

  • AMX nxd-700vi - page 85

    Firmware Pages and Desc riptions 71 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Firmware Pages and Descriptions This section describes each firmware page and their sp ecif ic functional elements. Setup Navigation Buttons These Setup Navigation Buttons (FIG. 52) appear on the left of the pane l screen when the Setup page is ...

  • AMX nxd-700vi - page 86

    Firmware Pages and Descripti ons 72 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Setup Page This page (FIG. 53) centers around basic Modero panel properties such as: Connecti on Status of the pan el, Display T imeout, Inacti vity Page Flip T ime, Inacti vity page fi le, and the Pa nel Brightness. The elements of the Setup p ...

  • AMX nxd-700vi - page 87

    Firmware Pages and Desc riptions 73 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Information The Informatio n button provides a menu to select either the Pr oject Information P age section on page 74 or the P anel Information P age section on page 75. Select either option to access that page. Setup Page Elements (Cont.) Ina ...

  • AMX nxd-700vi - page 88

    Firmware Pages and Descripti ons 74 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Project Informati on Page The Project Information page displays the TPDesign4 (TPD4) project f ile properties current ly loaded on the selected Modero panel (FIG. 55). Refer to the TPDesign4 T ouch P anel Pr ogr am instruction manual for more d ...

  • AMX nxd-700vi - page 89

    Firmware Pages and Desc riptions 75 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Panel Information Page The Panel Information page (FIG. 56) centers around Modero panel prope rties such as: resolution used, on- board memory , firmw are, address/channel info rmation, and st ring info rmation. The elements of the Panel Inform ...

  • AMX nxd-700vi - page 90

    Firmware Pages and Descripti ons 76 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Panel Information Page Elements (Cont.) Firmware V ersion: Displays the G4 firmware version being used by the panel. • V erify you have t he latest version from www.amx.com . Setup Port: Displays the setup port information/value being used by ...

  • AMX nxd-700vi - page 91

    Firmware Pages and Desc riptions 77 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Time & Date Settings Page The options on the T ime & Da te Settings page (FIG. 57) allow you to set and adjust time and date information on the NetLinx Master . If the time and/ or date on the Master is modif ied, all connected devices ...

  • AMX nxd-700vi - page 92

    Firmware Pages and Descripti ons 78 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Audio Settings Page The Audio Settings page (accessed by pressing the Au d i o button on the Setup page) allo ws you to adjust the master volume parameters and defa ult panel sounds on the panel. The page includes two tabs f or analog (FIG. 58) ...

  • AMX nxd-700vi - page 93

    Firmware Pages and Desc riptions 79 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom En vironmental acoustics, personal v oic e level and ambient noise are all deciding f actors when setting your mic, intercom and panel sound le vels. Consider your en vironment when adjusting intercom and sound lev els and use caution so as not ...

  • AMX nxd-700vi - page 94

    Firmware Pages and Descripti ons 80 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Panel Soun ds Information P opup Window Clicking the Inf ormation bu tton in the Default P anel Sounds section opens the P anel Sounds Information popup windo w (FIG. 60). Click the Close button to return to the Audio Settings page. Supported s ...

  • AMX nxd-700vi - page 95

    Firmware Pages and Desc riptions 81 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Video Settings Page The V ideo Settings page (FIG. 61) (accessed by pressing the Vi d e o button on the Setup page) sets the V ideo properties of the incoming video signal from an NXA-A VB/ ETHERNET Breakout Box. The elements of the V ideo Sett ...

  • AMX nxd-700vi - page 96

    Firmware Pages and Descripti ons 82 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Video Settings Page Elements (Cont.) Hue: Use the UP/DN buttons to alter the hue level of the incoming signal. • Range = 0 - 255, default = 128. ...

  • AMX nxd-700vi - page 97

    Firmware Pages and Desc riptions 83 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Protected Setup Navigation Buttons The Protected Setup Naviga tion Buttons (FIG. 62) appear on the le ft of the panel screen when the Pr otected Setup page is currently acti ve. FIG. 62 Protected Setup Navigation Buttons Press to access the Sys ...

  • AMX nxd-700vi - page 98

    Firmware Pages and Descripti ons 84 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Protected Setup Page The Protected Setup page (FIG. 63) centers around the properties used by the pane l to properly communicate with the NetLinx Master . Enter the factory default password ( 1988) into the password keypad to access this page f ...

  • AMX nxd-700vi - page 99

    Firmware Pages and Desc riptions 85 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Protected Setup Page Elements (Cont.) System Recovery: Allows you to either reset the touch panel to factory default settings and/or wipe out all existing touch panel pages: • The Reset System Settings button allows a user to wipe out all cur ...

  • AMX nxd-700vi - page 100

    Firmware Pages and Descripti ons 86 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom System Settings Page The System Settings page (FIG. 67) sets the Seco ndary DNS Addres s information with its corresponding IP communication parameters, Ne tLinx Master communication settings, a nd reads the de vice number assigned to the Moder ...

  • AMX nxd-700vi - page 101

    Firmware Pages and Desc riptions 87 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom System Settings Page Elements (Cont.) IP Settings: Sets the IP communication val ues for the panel and contains: DHCP/S tatic Sets the panel to either DHCP or S tatic communication modes. • DHCP (Dynamic Host Configuration Protocol) assigns I ...

  • AMX nxd-700vi - page 102

    Firmware Pages and Descripti ons 88 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Refer to the Step 3: Choose a Master Connection Mode section on page 52 for more detaile d in formation on using the System Settings page. Wireless Settings Page Use the options on the W ireless Settings page (FIG. 68) to configure comm unicati ...

  • AMX nxd-700vi - page 103

    Firmware Pages and Desc riptions 89 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Wireless Settings Page (Cont.) IP Settings: Sets the IP communication values for the panel: DHCP/ST A TIC Sets the panel to either DHCP or S tatic communication modes. • DHCP - a temporary IP Addresses is assigned to the panel by a DHCP serve ...

  • AMX nxd-700vi - page 104

    Firmware Pages and Descripti ons 90 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Wireless Settings Page (Cont.) Wireless Security (Cont.): WP A-PSK This button opens the WP A-PSK Settings page (FIG . 71 on page 95). “WP A-PSK” security is designed for environments where is it desirable to use WP A or WP A2, but an 802.1 ...

  • AMX nxd-700vi - page 105

    Firmware Pages and Desc riptions 91 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Secondary Connectio n Page The Secondary Connection page sets the communication information for an installe d wireless interf ace card. The NXD-CV5 T ouch panel is not enabled for wireless co mmunication and therefore, this page is not user - e ...

  • AMX nxd-700vi - page 106

    Firmware Pages and Descripti ons 92 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Open (Clear Text ) Settings Press the Open (Clear T ext) button to open the Op en (Clear T ext) Settings page (FIG. 69). Wireless Security pages (each Wi Fi card supports diffe rent security features) FIG. 69 Wireless Setti ngs page - Open (Cle ...

  • AMX nxd-700vi - page 107

    Firmware Pages and Desc riptions 93 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Open security does not utilize any encryption methodology , but requires an SSID (alpha-numer ic) entry . This entry must match the Network Name (SSID) entry of th e targ et W AP so the panel kno ws what de vice it is using to communicate wi th ...

  • AMX nxd-700vi - page 108

    Firmware Pages and Descripti ons 94 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Static WEP security requires that bot h a target W AP be identified and an encryption method be implemented prior to establishing communication. In addition to providing both Open and Shared Authentication capabilities, this page also supports ...

  • AMX nxd-700vi - page 109

    Firmware Pages and Desc riptions 95 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom  Refer to the Conf iguring a W ir eless Network Access section on page 43 for fu rther details on these security options .  Refer to the Using the Site Surve y tool section on page 44 for more information on using this feature. WPA- ...

  • AMX nxd-700vi - page 110

    Firmware Pages and Descripti ons 96 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom WP A-PSK security is designed for env ironments where is it desirable to use WP A or WP A2, but an 802.1x authentication server is not a v ailable. PSK connections are more secure th an WEP and are simpler to configure since they im plement dyn ...

  • AMX nxd-700vi - page 111

    Firmware Pages and Desc riptions 97 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom EAP-LEAP Setting s Press the EAP-LEAP b utton to open the EAP-LEAP Se ttings page (FIG. 72). EAP (Extensible Authentication Protocol) is an Enterprise authentication protocol th at can be used in both wired and wireless network en vironm ents. ...

  • AMX nxd-700vi - page 112

    Firmware Pages and Descripti ons 98 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom  Refer to the EAP A uthentication section on page 201 for further deta ils on these security options.  Refer to FIG. 73 for an ex ample of what a typi cal EAP-LEAP sy stem c onf iguration page would like. EAP-FAST Settin gs Press th ...

  • AMX nxd-700vi - page 113

    Firmware Pages and Desc riptions 99 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom FIG. 74 Wireless Settings page - EAP-F AST Settings EAP-FAST Settings SSID (Service Set Identifier): Opens an on-screen keyboard to enter the SSID name used on the target WA P . The SSID is a unique name used by the W AP , and is assigned to al ...

  • AMX nxd-700vi - page 114

    Firmware Pages and Descripti ons 100 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom EAP-PEAP Settings Press the EAP-PEAP b utton to open the EAP-PEAP Settings page (FIG. 75). PEAP (Protected Exte nsible Authentication Protoc ol) was de veloped as a way to securely transmit authentication inf ormation, such as passw ords, ov e ...

  • AMX nxd-700vi - page 115

    Firmware Pages and Desc riptions 101 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom There are two main v e rsions of the PEAP protocol su pported by panel’ s DeviceScape W ireless Client:  PEAPv0  PEAPv1 PEAP uses inner authentication mech anisms su pported by the De viceScape W ireless Client, the most common o ...

  • AMX nxd-700vi - page 116

    Firmware Pages and Descripti ons 102 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom  Refer to the EAP A uthentication section on page 201 for further deta ils on these security options.  Refer to the Using the Site Surve y tool section on page 44 for more information on using this feature. EAP-TTLS Setting s Press ...

  • AMX nxd-700vi - page 117

    Firmware Pages and Desc riptions 103 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom EAP-TTLS Settings SSID (Service Set Identifier): Opens an on-screen keyboard to enter the SSID name used on the target WA P . The SSID is a unique name used by the W AP , and is assigned to all panels on that network. An SSID is required by th ...

  • AMX nxd-700vi - page 118

    Firmware Pages and Descripti ons 104 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom  Refer to the EAP A uthentication section on page 201 for further deta ils on these security options.  Refer to the Using the Site Surve y tool section on page 44 for more information on using this feature. EAP-TLS Settings Press t ...

  • AMX nxd-700vi - page 119

    Firmware Pages and Desc riptions 105 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom  Refer to the EAP A uthentication section on page 201 for further deta ils on these security options.  Refer to the Using the Site Surve y tool section on page 44 for more information on using this feature. EAP-FAST Settings (Cont. ...

  • AMX nxd-700vi - page 120

    Firmware Pages and Descripti ons 106 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Client certif icate configu ration There are se ve ral ways in which a clie nt certif icate can be configured by an IT dep artment. The client certificate and pri vate key can both be in corporated into one f ile or split into two separate fil ...

  • AMX nxd-700vi - page 121

    Firmware Pages and Desc riptions 107 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Calibration Page This page (FIG. 78) allows you to calibrate the touch panel using a pre-selected touch dri ver .  Press and hold the grey Front Setu p Access button (b elo w the Modero LCD) for 6 seconds to access the Calibration page. ...

  • AMX nxd-700vi - page 122

    Firmware Pages and Descripti ons 108 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom G4 Web Control Page An on-board VNC (V irtual Network Computing) serv er al lo ws the panel to connect to any remote PC running a VNC client. Once connected, the clie nt can vie w and control the panel re motely . The options on this page allo ...

  • AMX nxd-700vi - page 123

    Firmware Pages and Desc riptions 109 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Refer to the Using G4 W eb Contr ol to Interact with a G4 P anel section on page 58 for more detailed instructions on how to use the G4 W eb Control page with the new web-based NetL inx Security application. G4 Web Control Page ( Cont.) G4 We ...

  • AMX nxd-700vi - page 124

    Firmware Pages and Descripti ons 110 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Sensor Setup The Sensor Setup page (FIG. 81) allows you to adjust the Light and Motion Sensor parameters on a Modero touch panel. The elements of the Sensor Setup page ar e described in the table be low: FIG. 81 Sensor Setup page A light level ...

  • AMX nxd-700vi - page 125

    Firmware Pages and Desc riptions 111 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Sensor Setup Page Elements (Cont.) Light Senso r: Allows you to monitor and alter the sensit ivity of the Modero panel light sensor: • The Light Sensor Level field indicates the level used to report the light sensor level back to the NetLinx ...

  • AMX nxd-700vi - page 126

    Firmware Pages and Descripti ons 112 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Making the Most of the Automated Br ightn ess Control Feature (DIM Mode) Please follow the steps below to set up Automated Brightness Control: 1. Set the lighting conditions in the room to maximum (turn On all the lights) . 2. Set the Maximum ...

  • AMX nxd-700vi - page 127

    Firmware Pages and Desc riptions 113 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Other Settings The Other Settings button pro vides a menu to select the Image Caching page, Passw ord Setup page, or SIP Settings page. Select any opt ion to access its page. FIG. 82 Other Settin gs menu ...

  • AMX nxd-700vi - page 128

    Firmware Pages and Descripti ons 114 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Image Caching Page The Image Caching page (FIG. 83) configures the alloca tion of memo ry for image caching. The G4 graphics engine caches ima ges to decrea se load time of previously viewed images. RAM cac hing is always enabled, and images ( ...

  • AMX nxd-700vi - page 129

    Firmware Pages and Desc riptions 115 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Image Caching Page Elements Image Cache Settings: Allocates Flash memory for image caching. Flash Cache Size Press the Up and Down arrows to add and remove memory . Flash memory allocation cannot exceed the amount of Flash memory on the panel. ...

  • AMX nxd-700vi - page 130

    Firmware Pages and Descripti ons 116 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Setting the image cache In the Pr otected Setup page: 1. Press the Cache but ton in the Pr otected Setup Navigation Buttons section. This opens t he Imag e Cache page. 2. Set the cache e xpiration in the f ield Flash/RAM Cache Expir es . The U ...

  • AMX nxd-700vi - page 131

    Firmware Pages and Desc riptions 117 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom The elements of the P asswor d Setup page are described in the table belo w: SIP Settings Page The options on the SIP Settings page (F IG. 85) enable you to establish ne twork settings for using your touch panel as an IP phone. W ith a CS G SI ...

  • AMX nxd-700vi - page 132

    Firmware Pages and Descripti ons 118 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Features on this page include: SIP Settings Page Back: Saves all changes and returns to the previous page. Connection Status icon: The icon in the upper-right corner of each Setup page shows online/offline state of the panel to the master . ? ...

  • AMX nxd-700vi - page 133

    Firmware Pages and Desc riptions 119 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Tools The T ools button provides a menu to select either the Pa n e l L o g s Pa g e section on page 119, the P anel Statistics Pa g e section on page 120, or the Connection Utility P age section on page 122. Select an y of the options to acce ...

  • AMX nxd-700vi - page 134

    Firmware Pages and Descripti ons 120 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Features on this page include: Checking the Panel Connection Logs 1. Press the T ools button in the Pr otected Setup Navigation Buttons section. This opens the T ools menu. 2. W ithin the T ools menu, press the Panel Logs button. All connectio ...

  • AMX nxd-700vi - page 135

    Firmware Pages and Desc riptions 121 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Features on this page include: FIG. 88 Panel Statistics page Panel Statistics Page Back: Saves all changes and returns to the previous page. Connection Status icon: The icon in the upper-right corn er of eac h Setup page shows online/offline s ...

  • AMX nxd-700vi - page 136

    Firmware Pages and Descripti ons 122 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Checking the Pa nel Statistics 1. Press the T ools button in the Pr otected Setup Navigation Buttons section. This opens the T ools menu. 2. W ithin the T ools menu, press the Panel Statistics button. All connec tion statistics are contained o ...

  • AMX nxd-700vi - page 137

    Firmware Pages and Desc riptions 123 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Features on this page include: Connection Utility Page Close: Closes the Connection Utility popup. Connection Status icon: The icon in the upper-right co rner of t he utility provides a constant visual i indication of current connection status ...

  • AMX nxd-700vi - page 138

    Firmware Pages and Descripti ons 124 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Using the Connection Utility 1. Press the T ools button in the Pr otected Setup Navigation Buttons section. This opens the T ools menu. 2. W ithin the T ools menu, press the Connection Utility b utton. This launches the Connection Utility p op ...

  • AMX nxd-700vi - page 139

    EAP Security & Server Certifica tes 125 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom EAP Security & Server Certificates Overview The follo wing EAP types all support a server certif icate:  EAP-PEAP  EAP-TTLS  EAP-TLS All three of these certif icate-us ing security methods are documente d in the fo ...

  • AMX nxd-700vi - page 140

    EAP Security & Server Certificates 126 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom ...

  • AMX nxd-700vi - page 141

    Full Duplex Intercom 127 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Full Duplex Intercom Overview V oIP technology gi ves users the ability to instantly crea te a high-quality , di gital home/off ice intercom network with no additional equipmen t required. By utilizing V oIP intercom, syst em inte gration is simple a nd c ...

  • AMX nxd-700vi - page 142

    Full Duplex Intercom 128 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Setting the Intercom Session Timeout 1. Select th e Setup button on your intercom page. 2. Press the up or down arro ws to increment the timeo ut up by 1 second in each direction. If your call exceeds your session timeout the panel pro vides you with a po ...

  • AMX nxd-700vi - page 143

    Full Duplex Intercom 129 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Allowing a panel to be monitored 1. Select th e Setup button on your intercom page. 2. On the intercom setup page, press A dvanc ed Setup . This launches the password numeric ke ypad. 3. Enter the password and press Done . The default password is P asswor ...

  • AMX nxd-700vi - page 144

    Full Duplex Intercom 130 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom 7. Press Exit when you are finished. Sample Intercom Page The module for duplex intercom capabl e panels includes user pages. While you can create your own intercom directory page (see Cr eating Inter com P ages section on page 133), it is possible to use ...

  • AMX nxd-700vi - page 145

    Full Duplex Intercom 131 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Sample Intercom Page ( Cont.) No. Name Description Channel Port:Code Ad dress Port:Code Lev el P or t:Code 7 Panel Directory Room Name The name of a panel in the intercom directory . Y ou can call the panel, enact privacy against the panel and monitor the ...

  • AMX nxd-700vi - page 146

    Full Duplex Intercom 132 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Answering an incoming cal l The provided in tercom pages include an answering popup windo w . The popup page indicates the name of the panel calling and two options:  Answer - Pressing this b utton opens the in tercom session with the other panel. ? ...

  • AMX nxd-700vi - page 147

    Full Duplex Intercom 133 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Creating Intercom Pages The easiest method of creating your ow n intercom pages is to start with the pages pro vided by AMX in the module download .ZIP f ile. Y ou can chan ge the aesthetics of the pages as long as the channel, address, lev el and links r ...

  • AMX nxd-700vi - page 148

    Full Duplex Intercom 134 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom ...

  • AMX nxd-700vi - page 149

    Programming 135 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Programming Overview Y ou can program the touch panel, using the commands in this secti on, to perform a wide vari ety of operations using Send_Commands and v ariable text commands. A device must f irst be defined in the NetLinx programming language with values f ...

  • AMX nxd-700vi - page 150

    Programming 136 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Page Commands (Cont. ) @DPG Delete a specific popup page from specified popup group if it exists. Syntax: "'@DPG-<popup page name>;<popup group name>'" Va r i a b l e : popup page name = 1 - 50 ASCII characters. Name of the popup pa ...

  • AMX nxd-700vi - page 151

    Programming 137 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Page Commands (Cont.) @PP A Close all popups on a specified page. If the page name is empty , the current page is used. Same as the ’Clear Page’ command in TPDesign4. Syntax: "'@PPA-<page name>'" Va r i a b l e : page name = 1 - 50 AS ...

  • AMX nxd-700vi - page 152

    Programming 138 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Page Commands (Cont. ) @PPM Set the modality of a specific popup page to Modal or NonModal. A Modal popup page, when active, only allows you to use the buttons and featur es on that popup page. All other buttons on the panel page are inactivated. Syntax: "&ap ...

  • AMX nxd-700vi - page 153

    Programming 139 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Page Commands (Cont.) @PSE Set the show effect for the specified popup page to the named show effect. Syntax: "'@PSE-<popup page name>;<show effect name>'" Va r i a b l e : popup page name = 1 - 50 ASCII characters. Name of the page ...

  • AMX nxd-700vi - page 154

    Programming 140 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Page Commands (Cont. ) PPOF Deactivate a specific popup page on either a specified page or the current page. If the page name is empty , the cu rr ent page is used (see example 2). If the popup page is part of a group, the whole group is deactivat ed. This command ...

  • AMX nxd-700vi - page 155

    Programming 141 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Programming Numbers The following information provides the progra mming numbers for colors, fonts, and borders. Colors can be used to set the colors on buttons, slider s, and pages. The lo west co lor number represents the lightest color -specific display; the hig ...

  • AMX nxd-700vi - page 156

    Programming 142 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom RGB Values for all 88 Basic Colors (Cont.) Index No . Name Red Green B lue 48 V ery Light Blue 0 0 255 49 Light Blue 0 0 223 50 Blue 0 0 191 51 Medium Blue 0 0 159 52 Dark Blue 0 0 127 53 V ery Dark Blue 0 0 95 54 V ery Light Purple 128 0 255 55 Light Purple 1 12 ...

  • AMX nxd-700vi - page 157

    Programming 143 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Font Styles and ID Numbers Font styles can be used to program the text fonts on b uttons, sliders, and pages. The following chart shows the default font type and th eir respecti ve ID numbers generated by TPDesign4. Border Styles and Programming Numbers Border sty ...

  • AMX nxd-700vi - page 158

    Programming 144 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom TPD4 Border Styles by Name No. Border styles No. Border styles 8 Circle 15 29 Cursor T op 9 Circle 25 30 Cursor T op with Hole 10 Circle 35 31 Cursor Left 1 1 Circle 45 32 Cursor Lef t with Hole 12 Circle 55 33 Cursor Right 13 Circle 65 34 Cursor Right with Hole 1 ...

  • AMX nxd-700vi - page 159

    Programming 145 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom TPD4 Border Styles by Name No. Border styles No. Border styles 76 Quad Line 1 18 Menu Right Rounded 15 77 Single Line 1 19 Menu Right Rounded 25 78 Windows Style Pop up 120 Menu Right Rounded 35 79 Windows Style Pop up (S tatus Bar) 121 Menu Right Rounded 45 80 Me ...

  • AMX nxd-700vi - page 160

    Programming 146 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom "^" Button Commands These Button Commands are used in Ne tLinx Studio and are case insensitive. All commands that begin with " ^ " hav e the capability of assigning a variable te xt address range and button state range. A device must first be d ...

  • AMX nxd-700vi - page 161

    Programming 147 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom "^" Button Commands (Cont.) ^B A U Append unicode text. Same format as ^UNI. Syntax: "'^BAU-<vt addr range>,<button states range>,<unicode text>'" Va r i a b l e : variable text address range = 1 - 4000. button state ...

  • AMX nxd-700vi - page 162

    Programming 148 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom "^" Button Commands (Cont .) ^BCT Set the text color to the specified color . Only if the specified text color is not the same as the curren t color . Note : Color can be assigned by color name (without spaces), number or R,G ,B value (RRGGBB or RRGGBBAA ...

  • AMX nxd-700vi - page 163

    Programming 149 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom "^" Button Commands (Cont.) ^BIM Set the input mask for the specified address. Syntax: "'^BIM-<vt addr range>,<input mask>'" Va r i a b l e : variable text address range = 1 - 4000. input mask = Refer to the T ext Area Inp ...

  • AMX nxd-700vi - page 164

    Programming 150 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom "^" Button Commands (Cont .) ^BMC (Cont.) Example: SEND_COMMAND Panel,"'^BMC-425,1,1,500,1,BR'" or SEND_COMMAND Panel,"'^BMC-425,1,1,500,1,%BR'" Copies the OFF state border of button with a variable text address of ...

  • AMX nxd-700vi - page 165

    Programming 151 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom "^" Button Commands (Cont.) ^BMF (Cont.) For some of these commands and values, refer to theRGB V alues for all 88 Basic Colors table on page 14 1. ’%CF<on fill color >’ = Set Fill Color. ’%CB<on border color>’ = Set Bord er Color . ? ...

  • AMX nxd-700vi - page 166

    Programming 152 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom "^" Button Commands (Cont .) ^BMI Set the button mask image. Mask image is used to crop a borderless button to a non-square shap e. This is typically used with a bitmap. Syntax: "'^BMI-<vt addr range>,<button states range>,<mask ...

  • AMX nxd-700vi - page 167

    Programming 153 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom "^" Button Commands (Cont.) ^BNP Set the T akeNote network password for the specified Addresses. Syntax: "'^BNP-<vt addr range>,<network password>'" Va r i a b l e : variable text address range = 1 - 4000. network password ...

  • AMX nxd-700vi - page 168

    Programming 154 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom "^" Button Commands (Cont .) ^BOR Set a border to a specific border style associated with a border value for those buttons with a defined address range. Refer to theBorder Styles and Programming Numbers table on page 143 for more information. Syntax: &qu ...

  • AMX nxd-700vi - page 169

    Programming 155 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom "^" Button Commands (Cont.) ^BSF Set the focus to the text area. Note : Select one button at a time (single vari able text address). Do not assign a variable text address range to set focus to multiple buttons. Only one variable text address can be in fo ...

  • AMX nxd-700vi - page 170

    Programming 156 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom "^" Button Commands (Cont .) ^BVL Log-On/Log-Off the computer control connection. Syntax: "'^BVL-<vt addr range>,<connection>'" Va r i a b l e : variable text address range = 1 - 4000. connection = 0 (Log-Off connection) a ...

  • AMX nxd-700vi - page 171

    Programming 157 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom "^" Button Commands (Cont.) ^CPF Clear all page flips from a button. Syntax: "'^CPF-<vt addr range>'" Va r i a b l e : variable text address range = 1 - 4000. Example: SEND_COMMAND Panel,"'^CPF-500'" Clears a ...

  • AMX nxd-700vi - page 172

    Programming 158 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom "^" Button Commands (Cont .) ^GDI Change the bargraph drag increment. Syntax: "'^GDI-<vt addr range>,<bargraph drag increment>'" Va r i a b l e : variable text address range = 1 - 4000. bargraph drag increment = The defau ...

  • AMX nxd-700vi - page 173

    Programming 159 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom "^" Button Commands (Cont.) ^GRU Change the bargraph ramp-up time in 1/10th of a second. Syntax: "'^GRU-<vt addr range>,<bargraph ramp up time>'" Va r i a b l e : variable text address range = 1 - 4000. bargraph ramp up ti ...

  • AMX nxd-700vi - page 174

    Programming 160 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom "^" Button Commands (Cont .) ^ICO Set the icon to a button. Syntax: "'^ICO-<vt addr range>,<button states range>,<icon index>'" Va r i a b l e : variable text address range = 1 - 4000. button states range = 1 - 256 f ...

  • AMX nxd-700vi - page 175

    Programming 161 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom "^" Button Commands (Cont.) ^JST Set text alignment using a numeric keypad layout for those buttons with a defined address range. The alignment of 0 is followed by ',<left>,<top> '. The left and top coordinates are relative to the u ...

  • AMX nxd-700vi - page 176

    Programming 162 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom "^" Button Commands (Cont .) ^SKT Receive touch information on specified socket. Syntax: '^SKT-<0=disable socket, greater than 1023=enable socket on specified port> Only socket values equal to or greater t han 1024 are valid. T he panel will o ...

  • AMX nxd-700vi - page 177

    Programming 163 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Text Effects Names The follo w ing is a listing of text ef fects names (associated with the ^TEF command on page 162). "^" Button Commands (Cont.) ^UNI Set Unicode text. For the ^UNI command (% UN and ^BMF command), the Unicode text is sent as ASCII-HEX ...

  • AMX nxd-700vi - page 178

    Programming 164 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Button Query Commands Button Query commands reply back with a custom ev ent. There will be one custom event for each button/state combination. Each query is assi gned a unique custom ev ent type. The f ollowing example is f or debug purposes only: NetLinx Example: ...

  • AMX nxd-700vi - page 179

    Programming 165 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Button Query Commands ?BCB Get the current border color . Syntax: "'?BCB-<vt addr range>,<button states range>'" Va r i a b l e : variable text address range = 1 - 4000. button states range = 1 - 256 for multi-state buttons (0 = All ...

  • AMX nxd-700vi - page 180

    Programming 166 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Button Query Commands (Cont.) ?BCT Get the current text color . Syntax: "'?BCT-<vt addr range>,<button states range>'" Va r i a b l e : variable text address range = 1 - 4000. button states range = 1 - 256 for multi-state buttons (0 ...

  • AMX nxd-700vi - page 181

    Programming 167 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Button Query Commands (Cont.) ?BOP Get the overall button opacity . Syntax: "'?BOP-<vt addr range>,<button states range>'" Va r i a b l e : variable text address range = 1 - 4000. button states range = 1 - 256 for multi-state button ...

  • AMX nxd-700vi - page 182

    Programming 168 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Button Query Commands (Cont.) ?BWW Get the current word wrap flag status. Syntax: "'?BWW-<vt addr range>,<button states range>'" Va r i a b l e : variable text address range = 1 - 4000. button states range = 1 - 256 for multi-state ...

  • AMX nxd-700vi - page 183

    Programming 169 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Button Query Commands (Cont.) ?ICO Get the current icon index. Syntax: "'?ICO-<vt addr range>,<button states range>'" Va r i a b l e : variable text address range = 1 - 4000. button states range = 1 - 256 for multi-state buttons (0 ...

  • AMX nxd-700vi - page 184

    Programming 170 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Button Query Commands (Cont.) ?JSI Get the current icon justification. Syntax: "'?JSI-<vt addr range>,<button states range>'" Va r i a b l e : variable text address range = 1 - 4000. button states range = 1 - 256 for multi-state but ...

  • AMX nxd-700vi - page 185

    Programming 171 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Button Query Commands (Cont.) ?TEC Get the current text effect color . Syntax: "'?TEC-<vt addr range>,<button states range>'" Va r i a b l e : variable text address range = 1 - 4000. button states range = 1 - 256 for multi-state but ...

  • AMX nxd-700vi - page 186

    Programming 172 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Panel Runtime Operations Serial Commands are use d in the AxcessX T erminal Emul ator mode. These commands are case insensiti ve. Button Query Commands (Cont.) ?TXT Get the current text information. Syntax: "'?TXT-<vt addr range>,<button states ...

  • AMX nxd-700vi - page 187

    Programming 173 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Panel Runtime Operatio n Commands (Cont.) @AKB Pop up the keyboard icon and initialize the tex t string to that specified. Keyboard string is set to null on power up and is stored until power is lost. The Prompt T ext is optional. Syntax: "'@AKB-<init ...

  • AMX nxd-700vi - page 188

    Programming 174 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Panel Runtime Operatio n Commands (Cont.) @AKR Remove the Keyboard/ Keypad. Remove keyboard or keypad that was displayed using ' AKEYB', 'AKEYP', 'PKEYP', @AKB, @AKP , @ PKP , @EKP , or @ TKP commands. Syntax: "'@AKR'&q ...

  • AMX nxd-700vi - page 189

    Programming 175 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Panel Runtime Operatio n Commands (Cont.) PKEYP Present a private keypad. Pops up the keypad icon and initializes the text string to that specified. Keypad displays a '*' instead of the numbers typed. The Prompt T ext is optional. Syntax: "'PKE ...

  • AMX nxd-700vi - page 190

    Programming 176 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Panel Runtime Operatio n Commands (Cont.) @SSL Change Sleep string. Syntax: "'@SSL-<string>'" Va r i a b l e s : string = name of sleep string. Example: SEND COMMAND Panel,"'@SWK-SLEEPNOW'" Changes the sleep string to ...

  • AMX nxd-700vi - page 191

    Programming 177 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Input Commands These Send Commands are case insensitiv e. Panel Runtime Operatio n Commands (Cont.) TP A GEOFF T urn Off p age tracking. Syntax: "'TPAGEOFF'" Example: SEND COMMAND Panel,"'TPAGEOFF'" T urns Off page tracking. ...

  • AMX nxd-700vi - page 192

    Programming 178 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Input Comm ands (Cont .) ^MBT Set the mouse button mode for the virtual PC. Syntax: "'^MBT-<0-3>'" Va r i a b l e : 0 = None. 1 = Left. 2 = Middle. 3 = Right. Example: SEND COMMAND Panel,"'^MBT-1'" Sets the mouse butto ...

  • AMX nxd-700vi - page 193

    Programming 179 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Embedded Codes The following is a list of G4 compatible embedded codes: Embedded Codes Decimal number s Hexidecimal values V ir t ual keystroke 8 ($08) Backspace 13 ($0D) Enter 27 ($1B) ESC 128 ($80) CTRL key down 129 ($81) AL T key down 130 ($82) Shift key down 1 ...

  • AMX nxd-700vi - page 194

    Programming 180 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Panel Setup Commands These commands a re case insensi tiv e. Panel Setup Commands CLOCK Sets the time and date on the panel. Syntax: “’CLOCK mm-dd-yy hh:mm:ss’” Va r i a b l e s : mm = Month dd = Day yy = Y ear hh = Hour mm = Minute ss = Second Example: SE ...

  • AMX nxd-700vi - page 195

    Programming 181 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Panel Setup Commands (Cont.) ^CFSM Sets the Flash cache to the maximum available size allowed for backup Flash cache. (determined by taking 75% of free Flash space) Syntax: “’^CFSM’” Va r i a b l e : There is no parameter for this command. Example: SEND_CO ...

  • AMX nxd-700vi - page 196

    Programming 182 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Dynamic Image Commands The following table describe s Dynamic Image Commands. Panel Setup Commands (Cont.) @RPP Reset the protected pas sw ord . @RPP resets the protected password to its default (1988). Syntax: "'@RPP'" Example: SEND COMMAND Pa ...

  • AMX nxd-700vi - page 197

    Programming 183 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom ^RAF, ^RMF - Embedded Codes The ^RAF and ^RMF commands add and modify any and all resource pa rameters by sending embedded codes and data: "'^RAF-<resource name>,<data>'" "'^RMF-<resource name>,<data>'&quo ...

  • AMX nxd-700vi - page 198

    Programming 184 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Escape Sequences The ^RAF and ^RMF commands support the replacement of any special escape se quences in the filename (specif ied by the %F embedded code) with the corre sponding data obtained from the system as outlined in the table below: For instance, http://www ...

  • AMX nxd-700vi - page 199

    Programming 185 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Intercom Commands The follo wing is a listing and descri ptions of panel intercom commands. Intercom Co mmands ^ICE Ends an intercom call. Syntax: "'^ICE'" Example: SEND_COMMAND Panel,"'^ICE'" Ends a call. ^ICM Modifies an i ...

  • AMX nxd-700vi - page 200

    Programming 186 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom SIP Commands The follo wing table list s and describes SIP commands that are generated from the touch panel. Intercom Co mmands (C ont.) ^ICS S tarts an intercom call to the specified IP address and ports. Syntax: ^ICS-<IP>,<TX UDP port>,<RX UDP por ...

  • AMX nxd-700vi - page 201

    Programming 187 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom SIP Commands (Cont.) ^PHN-INCOMING Provides incoming call notification. Provides incoming call notification and the con nection id used for all future commands related to this call. The connection id w ill be 0 or 1. Syntax: "'^PHN-INCOMING, <caller n ...

  • AMX nxd-700vi - page 202

    Programming 188 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom The follo wing table lists an d describes SIP commands that are sent to the touch panel to manage calls. SIP Commands (Cont.) ^PHN- TRANSFERRED Indicates a call has been transferred. Syntax: "'^PHN-TRANSFERRED'" Example: SEND_COMMAND Panel,&quo ...

  • AMX nxd-700vi - page 203

    Programming 189 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom SIP Commands (Cont.) ^PHN-HANGUP Hangs up the call. Syntax: "’^PHN-HANGUP, <connection id>’" Va r i a b l e : connection id = The identifying number of the connection Example: SEND_COMMAND Panel,"'^PHN-HANGUP, 1'" ^PHN-HOLD ...

  • AMX nxd-700vi - page 204

    Programming 190 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom The follo wing table lists and describes SIP setup comma nds. Using any of these co mm ands causes the current user to go of fline. SIP Setup Commands ^PHN-SETUP- DOMAIN Sets the realm for authentication. Syntax: "’^PHN-SETUP-DOMAIN,<domain>’" ...

  • AMX nxd-700vi - page 205

    Appendix A: Text Formatti ng 191 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Appendix A: Text Formatting Text Formatting Codes for Bargraphs/Joysticks T ext formatting codes for bar graphs pro vide a mechan ism to allow a portion of a bar graphs text to be dynamically provided in formation about the current status of the l ...

  • AMX nxd-700vi - page 206

    Appendix A: Text Formatting 192 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Text Area Input Masking T ext Area Input Masking can be used to limi t the allowed/correct characters that are ent ered into a text area. For e xample, in working with a zip code, a user could limit the entry to a max length of only 5 charact ers b ...

  • AMX nxd-700vi - page 207

    Appendix A: Text Formatti ng 193 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Refer to the follo wing Send Commands for more detailed information: Input mask ranges These ranges allo w a user to specify the minim um and maximum numeric v alue for a field. Only one range is allow ed per field. Using a rang e implies a n umer ...

  • AMX nxd-700vi - page 208

    Appendix A: Text Formatting 194 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom When operating with a mask, the mask should be disp layed with placeholders. The "-" character should display where you should enter a charac ter . The arrow ke ys will mov e betw een the "-" characters and allo w you to replace ...

  • AMX nxd-700vi - page 209

    Appendix A: Text Formatti ng 195 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Special es cape sequence s The system has only a limited kno wledge of URL formats in that it transparently passes the URL information onto the server for translation. A user can then pass an y parameters to the server side programs such as CGI sc ...

  • AMX nxd-700vi - page 210

    Appendix A: Text Formatting 196 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom ...

  • AMX nxd-700vi - page 211

    Appendix B - Wireless Technology 197 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Appendix B - Wireless Technology Overview of Wireless Technology  802.11b/2.4 GHz and 802.11a/5 GHz are the tw o major WLAN sta ndards and both operate using radio frequency (RF) technology . T ogether the two st andards are together cal ...

  • AMX nxd-700vi - page 212

    Appendix B - Wireless Technology 198 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Terminology  802.1x  IEEE 802.1x is an IEEE standard that is b uilt on the Intern et standard EAP (Extensible Authentication Protoc ol). 802.1x is a standard for passin g EAP messages over either a wired or wireless LAN. Addi tiona ...

  • AMX nxd-700vi - page 213

    Appendix B - Wireless Technology 199 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom  WP A  W i-Fi Protected Access (WP A and WP A2) is a cla ss of system used to secure wireless (W i-Fi) computer networks. It w as created in response to se veral serious weaknesses researchers had found in the pre vious WEP system. ...

  • AMX nxd-700vi - page 214

    Appendix B - Wireless Technology 200 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom  WP A2  Also know as IEEE 802.11i, is an amendment to the 802.11 st andard specifying security mechanisms for wireless networks. The 802. 11i scheme makes use of the Advanced Encryption Standard (AES) block cipher; WEP and WP A use ...

  • AMX nxd-700vi - page 215

    Appendix B - Wireless Technology 201 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom EAP Authentication EAP (Extensible Authentication Protocol) is an En terprise authenticat ion prot ocol that can be used in both a wired and wireless network en vironm ent. EAP requires the use of an 8 02.1x Authentication Serv er , also known ...

  • AMX nxd-700vi - page 216

    Appendix B - Wireless Technology 202 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom EAP communication overview EAP Authentication goes a step beyond just encrypting data tr ansfers, but also requires that a set of credentials be va lidated before the client (panel ) is allo wed to connect to the rest of the network (FIG. 100) ...

  • AMX nxd-700vi - page 217

    Appendix B - Wireless Technology 203 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom AMX Certificate Upload Utility The Certificate Upload utility gi ves you the ability to compile a list of targ et touch panels, se lect a pre-obtained certif icate (uniquely ident ifying the panel), and then uploa d that file to the selected p ...

  • AMX nxd-700vi - page 218

    Appendix B - Wireless Technology 204 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Step 2: Confirm t he Installation of the USB Driver on the PC The f irst time eac h AMX touch panel i s connected to the PC it is detected as a ne w hardware de vice and the USBLAN dri ver becomes associat ed with it (panel specific). Each tim ...

  • AMX nxd-700vi - page 219

    Appendix B - Wireless Technology 205 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom How to Upload a Certificate File 1. Install the latest AMX USB LAN LINK driv er onto your computer by installing th e latest versions of either TPDesign4 or NetLinx Studio2. This USB driv er prepares your computer to properly communicate with ...

  • AMX nxd-700vi - page 220

    Appendix B - Wireless Technology 206 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom ...

  • AMX nxd-700vi - page 221

    Appendix C: Troubleshooting 207 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Appendix C: Troubleshooting This section describes the solutions to possible hardware/firmware issues that could arise during the common operation of a Modero touch panel. Troubleshooting Information Symptom Solution My USB drivers has a yellow exc ...

  • AMX nxd-700vi - page 222

    Appendix C: Troubleshooting 208 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Troubleshooting Information (Cont.) Symptom Solution My Modero panel can’t obt ain a DHCP Address In requesting a DHCP Address, the DHCP Server can take up to a few minutes to provide the address. • V erify there is an a ctive Ethernet connecti ...

  • AMX nxd-700vi - page 223

    Appendix C: Troubleshooting 209 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Troubleshooting Information (Cont.) Symptom Solution There is a crawling, dashed line on the left border of the graphics. • On some units at some resolutions, there are wavy lines across the entire screen. This has been seen on middle resolutions ...

  • AMX nxd-700vi - page 224

    Appendix C: Troubleshooting 210 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom Troubleshooting Information (Cont.) Symptom Solution I have more that one Mo dero panel connected to my System Maste r and only one shows up. Multiple NetLinx Compatible devi c es (such as Modero panels) can be associated for use with a single Mast ...

  • AMX nxd-700vi - page 225

    Appendix C: Troubleshooting 211 NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with In tercom ...

  • AMX nxd-700vi - page 226

    4/11 © 2011 AMX. All rights reserved. AMX a nd the AMX logo are regist ered trademarks of AM X. AMX reserves the right to alter specific ations without notice at any time. It’s Your World - Take Con trol™ 3000 RESEARCH DRIVE, RICHARDSON, TX 75082 USA • 800.222.0193 • 469.624.8000 • 469-624-7153 fax • 800.932.6993 technical support • ...

Produzent AMX Kategorie Intercom System

Dokumente, die wir vom Produzenten des Geräts AMX nxd-700vi erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen AMX
- Bedienungsanleitungen nxd-700vi
- Produktkarten AMX
- Informationsbroschüren
- oder Energieetiketten AMX nxd-700vi
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung AMX nxd-700vi.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen AMX nxd-700vi, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen AMX nxd-700vi. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts AMX nxd-700vi ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts AMX nxd-700vi, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von AMX nxd-700vi hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von AMX nxd-700vi verständlich ist.

Eine gänzliche Bedienungsanleitung von AMX sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von AMX nxd-700vi bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von AMX nxd-700vi befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich AMX nxd-700vi, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts AMX nxd-700vi - die uns die ersten Schritte während der Nutzung von AMX nxd-700vi erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit AMX nxd-700vi hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von AMX nxd-700vi im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich AMX nxd-700vi?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit AMX nxd-700vi nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit AMX nxd-700vi hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)