Bedienungsanleitung APC SMT1500

21 Seiten 0.32 mb
Download

Zur Seite of 21

Summary
  • APC SMT1500 - page 1

    Operation Manual Smart-UPS ® UPS 750/1000/1500/2200/3000 V A T ower 120/230 V AC ...

  • APC SMT1500 - page 2

    Content s Smart-UPS 750/1000/1500/2200 /3 000 VA 120/230 Vac Tower i Overview ....................................... ................................... 1 Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • APC SMT1500 - page 3

    Smart-UPS 750/1000/1500/2200 /3 000 VA 120/230 Vac Tower ii Emergency Power Off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 EPO Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Normally open contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 N ...

  • APC SMT1500 - page 4

    1 Smart-UPS 750/1000/1500/2 200/3000 VA 120/230 Vac Tower Overview Product Description The APC ® by Schneider Electric Smart-UPS ® 750-30 00 V A 120/230 V ac T ower is a high performance Uninterruptible Power Supply (UPS). It provides pr otection for electronic equipment from utility power blackouts, brownouts, sags, and sur ges; small utility fl ...

  • APC SMT1500 - page 5

    Smart-UPS 750/1000/1500/2200 /3 000 VA 120/230 Vac Tower 2 Rear p a nels  USB port 750 V A 120 V ac 750 V A 230 V ac  Serial port  Ground screw  Smart slot  Circuit breaker  UPS input  Outlets  EPO connector 1000/1500 V A 1 20 V ac 1000/1500 V A 23 0 V ac 2200 V A 120 V ac/3000 V A 120 V ac† 2200/3000 V A 230 V ac †Circu ...

  • APC SMT1500 - page 6

    3 Smart-UPS 750/1000/1500/2 200/3000 VA 120/230 Vac Tower Specifications Operating Conditions This unit is intended for indoor use only . Select a location sturdy enough to support the weight of the UPS. Do not operate the unit where there is excessive dust, or the temperature or humidity are outside the specified limits. This unit has side air ven ...

  • APC SMT1500 - page 7

    Smart-UPS 750/1000/1500/2200 /3 000 VA 120/230 Vac Tower 4 Operation Connect Equipment to the UPS Note: The UPS will char ge to 90% capacity in th e first three hours of normal operation. Do not expect full battery run capability during this i nitial charge period. 1. Connect equipment to the outlets on the rear panel o f the UPS. Do not use extens ...

  • APC SMT1500 - page 8

    5 Smart-UPS 750/1000/1500/2 200/3000 VA 120/230 Vac Tower Display Interface Overview Using the display interface Use U P and D OWN to scroll through the main menu options. Press E NTER to view the sub-menus under each main menu option. Press E SCAPE to exit a sub-menu and return to a main menu. St andard menus The Standard menus are the most co mmo ...

  • APC SMT1500 - page 9

    Smart-UPS 750/1000/1500/2200 /3 000 VA 120/230 Vac Tower 6 Advanced menus The Advanced menus provid e additional options for the UPS and are available only if the display interface is configured to use the Advanced menus. About Display information about thi s unit: • U n i t model number • Serial number • Battery installation date • Suggest ...

  • APC SMT1500 - page 10

    7 Smart-UPS 750/1000/1500/2 200/3000 VA 120/230 Vac Tower Configuration UPS Settings St art-up Settings Configure these settings at initial start-up, using the display interface or APC PowerChute ® software. Note: During start-up, use the display interface to configure these settings. If nothing is selected, the until will u se the default setting ...

  • APC SMT1500 - page 11

    Smart-UPS 750/1000/1500/2200 /3 000 VA 120/230 Vac Tower 8 Low T ransfer Point 120 V : 106 V ac • 97 V a c • 100 V ac • 103 V ac • 106 V ac Set the transfer point lower if the utility voltage is chronically low and the connected equipment can tolerate this condition.This setting may also be adjusted using the power quality setting. Note: Us ...

  • APC SMT1500 - page 12

    9 Smart-UPS 750/1000/1500/2 200/3000 VA 120/230 Vac Tower Main Outlet Group and the Switched Outlet Group Overview The Main Outlet Group and the Switched Outlet Grou p can b e configured to indep endently turn of f, turn on, shut down, and reboot conn ected equipment. (Th ese features are not available on the 750 V A units.) The Main Outlet Group a ...

  • APC SMT1500 - page 13

    Smart-UPS 750/1000/1500/2200 /3 000 VA 120/230 Vac Tower 10 Network Management Card Settings These settings are available only on units that have a Network Management Card (NMC) and are set in the factory . These settings can only be modified using an external interface, like the NMC web interface. • NMC IP Address Mode • NMC IP Address • NMC ...

  • APC SMT1500 - page 14

    11 Smart-UPS 750/1000/1500/2 200/3000 VA 120/230 Vac Towe r Emergency Power Off EPO Overview The Emergency Power Of f (EPO) option is a safety feature that will immediately disconnect all connected equipment from utility po wer . The UPS will immediately shut down and will not switch to battery powe r . The UPS must be manually re-started to re-app ...

  • APC SMT1500 - page 15

    Smart-UPS 750/1000/1500/2200 /3 000 VA 120/230 Vac Tower 12 T roubleshooting Problem and P ossible Cause Solution The UPS will not turn on or ther e is no output The unit has not been turned on. Press the ON button once to turn on the UPS. The UPS is not connected to utility power . Ensure that the power cable is securel y connected to the unit and ...

  • APC SMT1500 - page 16

    13 Smart-UPS 750/1000/1500/2 200/3000 VA 120/230 Vac Towe r The replace battery i ndicator is illuminated The battery has a weak charge. Allow the battery to rechar ge for at least four hours. Then, perform a self-test. If the problem persists after recharging, replace the battery . The replacement battery is not properly connected. Ensure that the ...

  • APC SMT1500 - page 17

    Smart-UPS 750/1000/1500/2200 /3 000 VA 120/230 Vac Tower 14 Service and Support Service If the unit requires service, do not retu rn it to the dealer . Follow these steps: 1. Review the T r oubleshooting section of the UPS manual to eliminate common problems. 2. If the problem persists, contact APC Cust omer Support through the APC W eb site, www . ...

  • APC SMT1500 - page 18

    15 Smart-UPS 750/1000/1500/2 200/3000 VA 120/230 Vac Towe r T ransport the unit 1. Shut down and disconnect all connected equipment. 2. Disconnect the unit from utility power . 3. Disconnect all internal and ex ternal batteries (if applicable). 4. Follow the shipping instructions outlined in the Service . APC Worldwide Customer Support Customer sup ...

  • APC SMT1500 - page 19

    Smart-UPS Factory W arranty LIMITED W ARRANTY American Power Conversion (APC ) warrants its Smart-UPS (Produc ts) to be free from defects in materials and workmanship for a period of three (3) years, excluding the batteries, which are warranted for two (2) years from date of purchase. APC's obligation under this warranty is limited to repairin ...

  • APC SMT1500 - page 20

    Harmonized S tandards EN62040-1-1, EN62040-2, EN6095 0-1, IEC60950-1, EN55022, EN55024, IEC61000-3-2, 3-3, 4-2, 4-3, 4-4, 4-5, 4-6, 4-1 1 Applicable Council Directives 2006/95/EC; 2004/108/EC T y pe of Equipment Uninterruptible Power Sup ply Model Numbers SMT750I, SMT1000I, SMT 1500I, SMT2200I, SMT3000I Manufacturers American Power Conversion 132 F ...

  • APC SMT1500 - page 21

    06/2009 990-3534-0 01 © 2009 APC by Schneider Electric. APC, the APC logo are owned by Schneide r El ectric Industries S.A.S., American Power Conversion Co rporation, or their affiliat ed companies. All other tr ademarks are proper ty of their respective owners. ...

Produzent APC Kategorie Portable Generator

Dokumente, die wir vom Produzenten des Geräts APC SMT1500 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen APC
- Bedienungsanleitungen SMT1500
- Produktkarten APC
- Informationsbroschüren
- oder Energieetiketten APC SMT1500
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung APC SMT1500.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen APC SMT1500, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen APC SMT1500. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts APC SMT1500 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts APC SMT1500, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von APC SMT1500 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von APC SMT1500 verständlich ist.

Eine gänzliche Bedienungsanleitung von APC sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von APC SMT1500 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von APC SMT1500 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich APC SMT1500, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts APC SMT1500 - die uns die ersten Schritte während der Nutzung von APC SMT1500 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit APC SMT1500 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von APC SMT1500 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich APC SMT1500?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit APC SMT1500 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit APC SMT1500 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)