    UL TRAPROBE TM 100 INSTRUCTION MANUAL VOLUME 1.3 ...

  • Alpine VOLUME 1.3 - page 2

    NEED HELP??? HA VE QUESTIONS?? AT UE SYSTEMS, WE ARE DEDICATED TO SUPPORTING OUR ULTRAPROBE USERS. OUR STAFF HAS YEARS OF FIELD EXPERIENCE AND IS STANDING READY TO ASSIST YOU SHOULD YOU NEED US. WHEREVER YOU ARE, REMEMBER, WE ARE AS CLOSE AS YOUR PHONE, FAX OR COMPUTER. CALL: 914-592-1220 FAX: 914-347-2181 Email: ue@worldnet.att.net Internet: http: ...

  • Alpine VOLUME 1.3 - page 3

    The ULTRAPROBE 100 provides easy, accurate leak detection and mechanical inspection through advanced ultrasonic technology. Before you begin testing, it is advisable to familiarize yourself with the basic components of your kit. 1. PISTOL HOUSING The main component of the Ultraprobe is its' pistol housing. From back to front, let's examin ...

  • Alpine VOLUME 1.3 - page 4

    2. SCANNING MODULE This module is utilized to receive air-borne ultrasound such as the ultrasounds emitted by pressure leaks and electrical discharges. To use, make sure it is plugged in to the front end of the metered pistol housing by aligning the plug with the receptical and inserting it firmly. To use the Scanning Module: 1. Plug in to front en ...

  • Alpine VOLUME 1.3 - page 5

    To use the WARBLE TONE GENERATOR : 1. Turn Tone Generator on by selecting either "LOW" for a low amplitude signal (usually recom mended for small containers) or "HIGH" for high amplitude. In high, the Warble Tone Generator will cover up to 4,000 cubic feet (121.9 cu. meters) of unobstructed space. When the Tone Generator is on, ...

  • Alpine VOLUME 1.3 - page 6

    -4- UL TRAPROBE APPLICA TIONS 1. LEAK DETECTION This section will cover airborne leak detection of pressure and vacuum systems. (For information concerned with internal leaks such as in Valves and Steam Traps, refer to the appropriate sections). What produces ultrasound in a leak? When a gas passes through a restricted orifice under pressure, it is ...

  • Alpine VOLUME 1.3 - page 7

    -5- B. TO CONFIRM A LEAK: Position the Scanning Module, or the rubber focusing probe (if it is on the scanning module) close to the suspect leak site and move it, slightly, back and forth, in all directions. If the leak is at this location, the sound will increase and decrease in intensity as you sweep over it. In some instances, it is useful to po ...

  • Alpine VOLUME 1.3 - page 8

    -6- D. LOW LEVEL LEAKS In ultrasonic inspection of leakage, the amplitude of the sound often depends upon the amount of turbulence generated at the leak site. The greater the turbulence, the louder the signal, the less the turbulence, the lower the intensity of the signal. When a leak rate is so low that it produces little, if any turbulence that i ...

  • Alpine VOLUME 1.3 - page 9

    The Tone Test incorporates two basic components: a TONE GENERATOR (an ultrasonic transmitter) , and the Scanning Module in the Ultraprobe. To conduct the test: 1. Make certain the test item has no fluids or contaminants such as water, mud, sludge, etc., that can block the path of the transmitted ultrasound. -7- 2. Place the Tone Generator within th ...

  • Alpine VOLUME 1.3 - page 10

    2. ELECTRIC ARC, CORONA, TRACKING DETECTION There are three basic electrical problems that are detected with the Ultraprobe 500: Arcing: An arc occurs when electricity flows through space. Lightning is a good example. Corona: When voltage on an electrical conductor, such as an antenna or high voltage transmission line exceeds the threshold value, t ...

  • Alpine VOLUME 1.3 - page 11

    3. DETECTING BEARING WEAR Ultrasonic inspection and monitoring of bearings is by far the most reliable method for detecting incipient bearing failure. The ultrasonic warning appears prior to a rise in temperature or an increase in low frequency vibration levels. Ultrasonic inspection of bearings is useful in recognizing: a. The beginning of fatigue ...

  • Alpine VOLUME 1.3 - page 12

    DETECTING BEARING FAILURE COMPARATIVE TESTING. The comparative method involves testing two or more similar bearings and "com- paring" potential differences. FOR COMPARATIVE TEST 1. Use contact (stethoscope) module. 2. Select a "test spot" on the bearing housing. Touch that spot with the contact module. In ultrasonic sensing, the ...

  • Alpine VOLUME 1.3 - page 13

    5. LOCATING FAULTY STEAM TRAPS An ultrasonic test of steam traps is a positive test. The main advantage to ultrasonic testing is that it isolates the area being tested by eliminating confusing background noises. A user can quickly adjust to recognizing differences among various steam traps, of which there are three basic types: mechanical, thermost ...

  • Alpine VOLUME 1.3 - page 14

    THERMOSTATIC TRAPS (bellows & bimetallic) operate on a difference in temperature between condensate and steam. They build up condensate so that the temperature of condensate drops down to a certain level below saturation temperature in order for the trap to open. By backing up condensate, the trap will tend to modulate open or closed depending ...

  • Alpine VOLUME 1.3 - page 15

    6. LOCATING FAULTY VALVES Utilizing the contact (stethoscope) module in the Ultraprobe, valves can easily be monitored to determine if a valve is operating properly. As a liquid or gas flows through a pipe, there is little or no turbulence generated except at bends or obstacles. In the case of a leaking valve, the escaping liquid or gas will move f ...

  • Alpine VOLUME 1.3 - page 16

    ULTRASOUND TECHNOLOGY The technology of ultrasound is concerned with sound waves that occur above human perception. The average threshold of human perception is 16,500 Hertz. Although the highest sounds some humans are capable of hearing is 21,000 Hertz, ultrasound technology is usually concerned with frequencies from 20,000 Hertz and up. Another w ...

  • Alpine VOLUME 1.3 - page 17

    SPECIFICA TIONS Construction : Hand held ABS pistol type ultrasonic processor stainless steel sensor enclosures Circuitry: SMD/Solid State hybrid hetrodyne receiver Frequency Response: 20-100 kHz (centered at 28-42 kHz) Indicator: 10 segment LED bargraph (red) Sensitivity Selection: 8 position precision attenuation Power: 9 volt alkaline battery Lo ...

  • Alpine VOLUME 1.3 - page 18

    SAFETY ADVISOR Y PLEASE READ BEFORE USING YOUR INSTRUMENT . W ARNING Improper use of your ultrasonic detector may result in death or serious injury . Observe all safety precautions. Do not attempt to make any rep airs or adjustments while the equipment is operating. Be sure to turn off and LOCK OUT all electrical and mechanical sources before perfo ...

Produzent Alpine Kategorie Impact Driver

Dokumente, die wir vom Produzenten des Geräts Alpine VOLUME 1.3 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Alpine
- Bedienungsanleitungen VOLUME 1.3
- Produktkarten Alpine
- Informationsbroschüren
- oder Energieetiketten Alpine VOLUME 1.3
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Alpine VOLUME 1.3.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Alpine VOLUME 1.3, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Alpine VOLUME 1.3. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Alpine VOLUME 1.3 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Alpine VOLUME 1.3, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Alpine VOLUME 1.3 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Alpine VOLUME 1.3 verständlich ist.

Eine gänzliche Bedienungsanleitung von Alpine sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Alpine VOLUME 1.3 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Alpine VOLUME 1.3 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Alpine VOLUME 1.3, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Alpine VOLUME 1.3 - die uns die ersten Schritte während der Nutzung von Alpine VOLUME 1.3 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Alpine VOLUME 1.3 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Alpine VOLUME 1.3 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Alpine VOLUME 1.3?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Alpine VOLUME 1.3 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Alpine VOLUME 1.3 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)