Bedienungsanleitung Campbell Hausfeld GR3000

20 Seiten 1.92 mb
Download

Zur Seite of 20

Summary
  • Campbell Hausfeld GR3000 - page 1

    Operating Instructions P ower P ack IN974302AV 6/13 © 2013 Campbell Hausfeld/Scott Fetzer For parts, product & service information visit www.campbellhausfeld.com GR3000 RET AIN THIS INFORMA TION FOR FUTURE REFERENCE Serial Number: Model Number: Date of Purchase: T able of Contents Description . . . . . . . . . . . . . . . . . . . . . . . . . 1 ...

  • Campbell Hausfeld GR3000 - page 2

    Safety Guidelines This manual contains information that is very important to know and understand. This information is pro vided for SAFETY and to PREVENT EQ UIPMENT PROBLEMS. T o help recognize this information, observe the following symbols . Danger indicates an imminently hazardous situation which, if not avoided , WILL result in death or serious ...

  • Campbell Hausfeld GR3000 - page 3

    ◆ Keep all persons away fr om the unit during operation. ◆ NEVER allo w children in the work ar ea. ◆ Do not allo w persons wearing loose clothing or jewelry to start or operate the unit. Loose clothing or jewelry may become entangled in mo ving components, causing equipment damage and or personal injury . ◆ Keep all persons away fr om part ...

  • Campbell Hausfeld GR3000 - page 4

    Operating Instructions www .campbellhausfeld.com 4 ◆ N ever use an electric arc welder to thaw fro zen pipes. Flying sparks and hot metal can cause injury . As welds cool, slag can be thrown off . T ake all precautions described in this manual to reduce the possibility of injury from flying sparks and hot metal. ◆ W ear ANSI compliant face shie ...

  • Campbell Hausfeld GR3000 - page 5

    COMPRESSOR SAFETY Never r emo ve or attempt to adjust safety valve. Keep safety v alve free from paint and other accumulations. Nev er attempt to repair or modify a tank! W elding , drilling or any other modification will weaken the tank resulting in damage from ruptur e or explosion. Always r eplace worn or damaged tanks. ◆ T anks rust from moi ...

  • Campbell Hausfeld GR3000 - page 6

    Operating Instructions www .campbellhausfeld.com 6 AC or Alternating Curr ent - electric current that r everses direction periodically . Sixty cycle curr ent travels in both directions sixty times per second. Arc Length - the distance from the end of the electr ode to the point where the ar c makes contact with the work surface. Base M etal - the m ...

  • Campbell Hausfeld GR3000 - page 7

    LOCA TION Selecting the proper location can significantly incr ease performance, reliability and life of the unit. ◆ F or best results locate the unit in an environment that is clean and dry . Dust and dirt in the unit retain moistur e and increase wear of mo ving par ts. ◆ There ar e mounting holes in the bottom of the open frame models to per ...

  • Campbell Hausfeld GR3000 - page 8

    Operating Instructions www .campbellhausfeld.com 8 LOW OIL SHUTDOWN A lo w oil shutdown switch is pro vided to protect the engine. When engine oil level drops too lo w for proper engine operation, the lo w oil shutdown switch causes the engine to shut off. If oil level is lo w when attempting to start the engine, the lo w oil level shutdo wn switch ...

  • Campbell Hausfeld GR3000 - page 9

    INST ALLA TION FOR ST AND-BY USE Pr ecautions must be taken to prevent electrical back feeding into utility systems. This requires isolation of the electrical system. T o isolate the electrical system, perform the following procedur es: 1. T urn off the main electrical system switch prior to connecting the unit. 2. In accor dance with national and ...

  • Campbell Hausfeld GR3000 - page 10

    Operating Instructions www .campbellhausfeld.com 10 Welder Operation ( FRONT P ANEL SWITCH MUST BE SET TO WELDER POSITION ) WELDING LEAD ASSEMBLIES W elding leads assemblies are not included with all units. U se copper welding cables in the size specified in T able 3. 1. V erify that the surfaces of metals to be joined are free from dirt, rust, pai ...

  • Campbell Hausfeld GR3000 - page 11

    GR3000 www .campbellhausfeld.com 11 Release all pr essure from the system before attempting to install, service, relocate or perform any maintenance. In or der to maintain efficient operation of the compressor system, check the air filter , oil level and gasoline level before each use . The ASME safety valve should also be checked daily . Pull ring ...

  • Campbell Hausfeld GR3000 - page 12

    Operating Instructions www .campbellhausfeld.com 12 Maintenance (Continued) INFREQUENT USAGE If the unit is used infrequently , starting difficulty may occur . T o help prevent this , the engine should be run for approximately 30 minutes per week. STORAGE If the unit is not to be used for extended periods of time, the follo wing pre-storage procedu ...

  • Campbell Hausfeld GR3000 - page 13

    GR3000 www .campbellhausfeld.com 13 GENERAL This line of welding machines utilizes a process kno wn as Shielded M etal-Ar c W elding (SMA W ). This process is used to bond metals b y heating them with an electric arc created between the electr ode and the work piece. Electrodes used for shielded metal arc welding hav e two parts. The inner core is ...

  • Campbell Hausfeld GR3000 - page 14

    Operating Instructions Welding Guidelines (Continued) ARC WELDING BASICS F our basic techniques affect weld quality . These ar e: amperage setting, weld angle, ar c length, and travel speed. P roper use of these techniques is necessary for good weld quality . AMPERAGE SETTING The correct amper age involves the adjustment of the welding machine to t ...

  • Campbell Hausfeld GR3000 - page 15

    TRA VEL SPEED The travel speed is the rate at which the electr ode is moved acr oss the weld area (S ee Figur e 4). When the speed is too fast, the bead is narro w and bead ripples are pointed as sho wn. When the speed is to slo w , the weld metal piles up and the bead is high and wide. T o control travel speed, watch the width of the weld bead (no ...

  • Campbell Hausfeld GR3000 - page 16

    Operating Instructions www .campbellhausfeld.com 16 Lamp Off Lamp On Figure 8 - Diode T est Procedur e Welding Guidelines (Continued) TESTING WELDER / GENERA TOR DIODES The follo wing method eliminates the need to disconnect the diodes from the welder / generators wiring. 1. U se a 12 V olt battery and automotive lamp ( T ype 5001) to test the diod ...

  • Campbell Hausfeld GR3000 - page 17

    GR3000 www .campbellhausfeld.com 17 T roubleshooting Chart (Continued) Generator Symptom Possible Cause(s) Corr ective Action No output voltage 1. Engine speed is too slow 2. Open, shorted, or incorrect wiring 3. Faulty capacitor 4. Open or shorted field windings 5. Open diodes 6. Front panel switch set incorrectly 7. Circuit breaker tripped 1. Adj ...

  • Campbell Hausfeld GR3000 - page 18

    Operating Instructions www .campbellhausfeld.com 18 Welds Symptom Possible Cause(s) Corr ective Action Bead is intermittently too thin or too thick 1. Inconsistent travel speed 2. Output amp setting incorrect 1. Carefully watch and control the width of the molten weld bead 2. Adjust output amp setting or change to smaller diameter electrode Ragged ...

  • Campbell Hausfeld GR3000 - page 19

    GR3000 www .campbellhausfeld.com 19 Figure 9 - Wiring Diagram ...

  • Campbell Hausfeld GR3000 - page 20

    Operating Instructions Reminde r: Keep your dated proof of purchase for warr anty purposes! Attach it to this manual or file it for safekeeping. Limited Warranty 1. DURA TION: The manufactur er warrants that it will repair , at no charge for parts or labor , the following C ampbell Hausfeld products pro ven defective in material or workmanship , du ...

Produzent Campbell Hausfeld Kategorie Welding System

Dokumente, die wir vom Produzenten des Geräts Campbell Hausfeld GR3000 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Campbell Hausfeld
- Bedienungsanleitungen GR3000
- Produktkarten Campbell Hausfeld
- Informationsbroschüren
- oder Energieetiketten Campbell Hausfeld GR3000
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Campbell Hausfeld GR3000.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Campbell Hausfeld GR3000, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Campbell Hausfeld GR3000. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Campbell Hausfeld GR3000 ansehen.

Die komplette Bedienungsanleitung des Geräts Campbell Hausfeld GR3000, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Campbell Hausfeld GR3000 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Campbell Hausfeld GR3000 verständlich ist.

Eine gänzliche Bedienungsanleitung von Campbell Hausfeld sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Campbell Hausfeld GR3000 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Campbell Hausfeld GR3000 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Campbell Hausfeld GR3000, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Campbell Hausfeld GR3000 - die uns die ersten Schritte während der Nutzung von Campbell Hausfeld GR3000 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Campbell Hausfeld GR3000 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Campbell Hausfeld GR3000 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Campbell Hausfeld GR3000?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Campbell Hausfeld GR3000 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Campbell Hausfeld GR3000 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)