    OM−05463−OE01 February 4, 2003 THE GORMAN-RUPP COMP ANY D MANSFIELD , OHIO GORMAN-RUPP OF CANADA LIMITED D ST . THOMAS, ONT ARIO, CANADA Printed in U.S.A. www .gormanrupp.com E Copyright by the Gorman-Rupp Company INST ALLA TION, OPERA TION, AND MAINTENANCE MANU AL WITH P ARTS LIST 10 SERIES PUMPS MODELS 13D1−19 and 13D1−(19) PPO ...

  • Briggs & Stratton 13D1-(19) PPO - page 2

    The engine exhaust from this product contains chemicals known to the State of California t o cause cancer , birth defects or other reproductive harm. ...

  • Briggs & Stratton 13D1-(19) PPO - page 3

    T ABLE OF CONTENTS i INTRODUCTION P AGE I − 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SAFETY - SECTION A P AGE A − 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . INST ALLA TION − SECTION B P AGE B − 1 . . . . . . . . . . . . . . . . . . . . ...

  • Briggs & Stratton 13D1-(19) PPO - page 4

    T ABLE OF CONTENTS (continued) ii Pump P arts Only P AGE E − 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PUMP AND SEAL DISAS SEMBL Y AND REASSEMBL Y P AGE E − 6 . . . . . . . . . . . . . . . . . . . . . . . . . Suction Check V alve Disassembly P AGE E − 6 . . . . . . . . . . ...

  • Briggs & Stratton 13D1-(19) PPO - page 5

    10 SERIES OM−05463 P AGE I − 1 INTRODUCTION INTRODUCTION Thank Y ou for purchasing a Gorman-Rupp pump. Read this manual carefully to learn how to safely install and operate your pump. Failure to do so could result in personal injury or damage to the pump. This Installation, Operation, and Mainte- nance manual is designed to help you achieve the ...

  • Briggs & Stratton 13D1-(19) PPO - page 6

    10 SERIES OM−05463 P AGE A − 1 SAFETY SAFETY − SECTION A This information applies to 10 Series en- gine driven pumps. Refer to the manual accompanying the engine before at- tempting to begin operation. Because pump installations are seldom identical, this manual cannot possibly provide detailed instructions and pre- cautions for each specific ...

  • Briggs & Stratton 13D1-(19) PPO - page 7

    10 SERIES OM−05463 P AGE A − 2 SAFETY Do not operate an internal combustion engine in an explosive atmosphere. When operating internal combustion engines in an enclosed area, make cer- tain that exhaust fumes are piped to the outside. These fumes contain carbon monoxide, a deadly gas that is color- less, tasteless, and odorless. Fuel used by in ...

  • Briggs & Stratton 13D1-(19) PPO - page 8

    10 SERIES OM−05463 P AGE B − 1 INST ALLATION INST ALLA TION − SECTION B Review all SAFETY information in Section A . Since pump installations are seldom identical, this section offers only general recommendations and practices required to inspect, position, and ar- range the pump and piping. Most of the information pertains to a standard s ta ...

  • Briggs & Stratton 13D1-(19) PPO - page 9

    OM−05463 10 SERIES P AGE B − 2 INST ALLATION c. Carefully read all tags, decals, and markings on the pump assembly , and perform all duties indicated. d. Check levels and lubricate as necessary . Re- fer to LUBRICATION in the MAINTENANCE AND RE P AIR section of this manual and per- form duties as instructed. e. If the pump and engine have been ...

  • Briggs & Stratton 13D1-(19) PPO - page 10

    10 SERIES OM−05463 P AGE B − 3 INST ALLATION forced type to prevent collapse under suction. Us- ing piping couplings in suction lines is not recom- mended. Line Configuration Keep suction and discharge lines as straight as possible to minimize friction losses. Make mini- mum use of elbows and fittings, which substan- tia lly increase friction l ...

  • Briggs & Stratton 13D1-(19) PPO - page 11

    OM−05463 10 SERIES P AGE B − 4 INST ALLATION If it is necessary to position inflow close to the suc- tio n inlet, install a baffle between the inflow and the suction inlet at a distance 1-1/2 times the diameter of the suction pipe. The baffle will allow entrained air to escape from the liquid before it is drawn into the suction inlet. If two su ...

  • Briggs & Stratton 13D1-(19) PPO - page 12

    10 SERIES OM−05463 P AGE B − 5 INST ALLATION W it h high discharge heads, it is recommended that a throttling valve and a system check valve be in- stalled in the discharge line to protect the pump from excessive shock pressure and reverse rota- tion when it is stopped. If the application involves a high discharge head, gradually close the disc ...

  • Briggs & Stratton 13D1-(19) PPO - page 13

    OM−05463 10 SERIES OPERA TION P AGE C − 1 OPERA TION − SECTION C Review all SAFETY information in Section A . Follow the instructions on all tags, labels and decals attached to the pump. This pump is designed to handle dirty water containing specified entrained solids. Do not attempt to pump volatile, corrosive, or flammable liquids which ma ...

  • Briggs & Stratton 13D1-(19) PPO - page 14

    OM−05463 10 SERIES OPERA TION P AGE C − 2 line. Air from the suction line will be discharged through th e bypass line back to the wet well during the priming cycle. When the pump is fully primed and liquid is flowing steadily from the bypass line, open the discharge throttling valve. Liquid will then continue to circulate through the bypass lin ...

  • Briggs & Stratton 13D1-(19) PPO - page 15

    OM−05463 10 SERIES OPERA TION P AGE C − 3 shock waves can be transmitted to the pump and piping system. Close all connecting valves slo wly . On engine driven pumps, reduce the throttle speed s low ly and allow the engine to idle briefly be- fore stopping. If the application involves a high discharge head, gradually close the discharge throttli ...

  • Briggs & Stratton 13D1-(19) PPO - page 16

    TROUBLE POS SIBLE CA USE PROBABLE REMEDY PUMP F AILS TO PRIME Strainer clogged. Check strainer and clean if neces- sary . Suction lift or discharge head too high. Check piping installation and install bypass line if needed. See INSTAL- LA TION . Leaking or worn seal or pump gasket. Check pump vacuum. Replace leaking or worn seal or gasket. Lining o ...

  • Briggs & Stratton 13D1-(19) PPO - page 17

    TROUBLE POS SIBLE CAUSE PROBABLE REMED Y PUMP STOPS OR F AILS TO DELIVER RA TED FL OW OR PRES SURE PUMP REQUIRES TOO MUCH POWER PUMP CL OGS FREQUENTL Y F ree impeller of debris. Impeller clogged. Discharge head too low . Dilute if possible. Liquid solution too thick. Adjust discharge valve. Open discharge valve fully to in- crease flow rate, and ru ...

  • Briggs & Stratton 13D1-(19) PPO - page 18

    OM−05463 10 SERIES TROUBLESHOOTING P AGE D − 3 PREVENTIVE MAINTENANCE Sin ce pump applications are seldom identical, and pump wear is directly affected by such things as the abrasive qualities, pressure and temperature of the liquid being pumped, this section is intended only to provide general recommendations and practices for preventive maint ...

  • Briggs & Stratton 13D1-(19) PPO - page 19

    10 SERIES OM−05463 MAINTENANCE & REP AIR P AGE E − 1 PUMP MAINTENANCE AND REP AIR - SECTION E MAINTENANCE AND REP AIR OF THE WEARING P ARTS OF THE PUMP WILL MAINT AIN PEAK OPERA TING PERFORMANCE. ST ANDARD PERFORMANCE FOR PUMP MODELS 13D1−19 Based on 70 _ F (21 _ C) clear water at sea level with minimum suction lift. Since pump installati ...

  • Briggs & Stratton 13D1-(19) PPO - page 20

    10 SERIES OM−05463 MAINTENANCE & REP AIR P AGE E − 2 SECTION DRA WING P ARTS P AGE Figure 1. Pump Model 13D1−19 ...

  • Briggs & Stratton 13D1-(19) PPO - page 21

    10 SERIES OM−05463 MAINTENANCE & REP AIR P AGE E − 3 P ARTS LIST Pump Models 13D1−19 (From S/N 1259620 up) If your pump serial number is foll owed by an N", your pump is NOT a standard production model. Contact the Gorman-Rupp Company to verify part numbers. ITEM NO . P ART NAME P ART NUMBER MA T’L CODE QTY 1 PUMP END ASSY 13D1? ...

  • Briggs & Stratton 13D1-(19) PPO - page 22

    10 SERIES OM−05463 MAINTENANCE & REP AIR P AGE E − 4 SECTION DRA WING Figure 2. 13D1−(19) Pump Parts Only ...

  • Briggs & Stratton 13D1-(19) PPO - page 23

    ITEM NO. P ART NAME P ART NUMBER MA T’L CODE QTY ITEM NO. P ART NAME P ART NUMBER MA T’L CODE QTY 10 SERIES OM−05463 MAINTENANCE & REP AIR P AGE E − 5 P ARTS LIST 13D1−(19) Pump Parts Only 1 PUMP CASING 13304 13040 1 2 IMPELLER 13303H 11060 1 3 SEAL ASSY 25285−855 −−− 1 4 IMP A DJ SHIM SET 2X 17090 REF 5 SPRING CENT W ASHER 31 ...

  • Briggs & Stratton 13D1-(19) PPO - page 24

    10 SERIES OM−05463 MAINTENANCE & REP AIR P AGE E − 6 PUMP AND SEAL DISASSEMBL Y AND REASSEMBL Y Review all SAFETY information in Section A . Follo w the instructions on all tags, label and de - cals attached to the pump. This pump requires little service due to its rugged, minimum-maintenance design. However , if it be- comes necessary to i ...

  • Briggs & Stratton 13D1-(19) PPO - page 25

    OM−05463 10 SERIES MAINTENANCE & REP AIR P AGE E − 7 Pump Casing Removal (Figure 2) T o service the impeller or seal assembly , discon- nect the discharge piping. See Figure 1 and re- move the hardware (12, 13 and 14) securing the pump casing to the base (3). Support t he pump casing (1) using a suitable hoist and sling, and remove the hard ...

  • Briggs & Stratton 13D1-(19) PPO - page 26

    10 SERIES OM−05463 MAINTENANCE & REP AIR P AGE E − 8 T o ease installation of the seal, lubricate the O- rings, sleeve and bellows with water or a very small amount of oil, and apply a drop of light lubricating oil on the finished faces. Assemble the seal as fol- lows, (see Figure 3). SPRING CENTERING WASHER SPRING RET AINER O -RING ST A TI ...

  • Briggs & Stratton 13D1-(19) PPO - page 27

    OM−05463 10 SERIES MAINTENANCE & REP AIR P AGE E − 9 Lubricate the seal as indicated in LUBRICA TION , after the impeller has been installed. Impeller Installation And Adjustment (Figure 2) Inspect the impeller and replace it if cracked or badly worn. Install the same thickness of impeller shims (4) as previously removed. Apply anti-seize t ...

  • Briggs & Stratton 13D1-(19) PPO - page 28

    THE GORMAN-RUPP COMP ANY AND GORMAN-RUPP OF CANADA LIMITED 12 MONTH LIMITED W ARRANTY EXTENT AND DURA TION OF W ARRANTY Coverage: The Gorman-Rupp Company or Gorman-Rupp of Canada Limited (herein individually referred to as GR") each indi vidually warrant that its products and parts shall be free from defects in material and workmanship for ...

Produzent Briggs & Stratton Kategorie Heat Pump

Dokumente, die wir vom Produzenten des Geräts Briggs & Stratton 13D1-(19) PPO erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Briggs & Stratton
- Bedienungsanleitungen 13D1-(19) PPO
- Produktkarten Briggs & Stratton
- Informationsbroschüren
- oder Energieetiketten Briggs & Stratton 13D1-(19) PPO
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Briggs & Stratton 13D1-(19) PPO.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Briggs & Stratton 13D1-(19) PPO, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Briggs & Stratton 13D1-(19) PPO. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Briggs & Stratton 13D1-(19) PPO ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Briggs & Stratton 13D1-(19) PPO, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Briggs & Stratton 13D1-(19) PPO hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Briggs & Stratton 13D1-(19) PPO verständlich ist.

Eine gänzliche Bedienungsanleitung von Briggs & Stratton sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Briggs & Stratton 13D1-(19) PPO bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Briggs & Stratton 13D1-(19) PPO befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Briggs & Stratton 13D1-(19) PPO, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Briggs & Stratton 13D1-(19) PPO - die uns die ersten Schritte während der Nutzung von Briggs & Stratton 13D1-(19) PPO erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Briggs & Stratton 13D1-(19) PPO hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Briggs & Stratton 13D1-(19) PPO im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Briggs & Stratton 13D1-(19) PPO?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Briggs & Stratton 13D1-(19) PPO nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Briggs & Stratton 13D1-(19) PPO hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)