Bedienungsanleitung Axor 06401XX0

12 Seiten 3.88 mb
Download

Zur Seite of 12

Summary
  • Axor 06401XX0 - page 1

    ThermoBalance II Deck V alve Metris S 06401XX0 Focus S 06405000 Solaris E 06450XX0 Stratos E 06451XX0 Metro E 06452XX0 T alis S 06453XX0 C Cross 06454XX0 C Scroll 06455XX0 C Lever 06456XX0 Solaris² E 04172XX0 Allegro² E 04185XX0 Metro² E 04198XX0 Installation Instructions / W arranty ...

  • Axor 06401XX0 - page 2

    2 ThermoBalance II Deck V alve 06401XX0 Metris S 06405000 Focus S 06450XX0 Solaris E 06451XX0 Stratos E 06452XX0 Metro E 06453XX0 T alis S 06450XX0 06451XX0 06452XX0 06453XX0 06454XX0 06455XX0 06456XX0 06401XX0 06405XX0 06454XX0 C Cross 06455XX0 C Scroll 06456XX0 C Lever 04172XX0 Solaris² E 04185XX0 Allegro² E 04198XX0 Metro² E ...

  • Axor 06401XX0 - page 3

    3 04198XX0 04172XX0 04185XX0 T echnical Specification Recommended pressure 45 - 72 psi Maximum hot water temp. 165° F* Recommended hot water temp. 120° - 140° F* Flow rate @ 44 PSI 8 gpm Safety stop 100° F 1/2" female NPT inlets Maximum mounting surface thickness 1 3/8" Hole size in mounting surface 2 3/8" *Know and follow all ap ...

  • Axor 06401XX0 - page 4

    4 Install the rough Rest the rough on the mounting surface. T ighten the lower mounting ring and washer . T ighten the tensioning screws. Install the plaster shield. Remove the upper mounting ring. Screw the lower mounting ring and washer to their lowest position. Insert the rough up through the hole. Install the upper mounting ring. T ighten it as ...

  • Axor 06401XX0 - page 5

    5 If the supplies are not connected to the correct inlets, the valve cannot function properly! Both outlets must be plumbed! Install the hot and cold water supply lines* W rap the threads on the hot and cold supply pipes with T eflon tape. Install the hot and cold supplies to the corresponding inlets. Install the outlet lines* W rap the threads on ...

  • Axor 06401XX0 - page 6

    6 Install the valve trim Remove the plaster shield. Push the escutcheon over the valve. Install the handle. T ighten the screw with a 3 mm Allen wrench. The screw must engage the slot on the cartridge. Justify the handle. Set the high temperature limit stop, if required. Justify the handle T urn the water on to the tub spout or hand- shower . Place ...

  • Axor 06401XX0 - page 7

    7 Set the high temperature limit stop (optional) T urn the water on to the tub spout or handshower . Use a 3 mm Allen wrench to loosen the handle screw . Remove the handle from the valve. Carefully remove the retainer clip and the limit stop ring (1). T urn the temperature control stem until the water is the desired high temperature, usually 110°F ...

  • Axor 06401XX0 - page 8

    8 Maintenance: Clean the filters CAUTION: T urn off the water at the main or with the ser vice stops, before opening the valve. Remove the handle and escutcheon. Failure to hold the stop unit steady while unscrewing or replacing the thermostat car tridge will result in damage to the stop unit. Grasp the wrench flats on the cartridge stop unit with ...

  • Axor 06401XX0 - page 9

    9 Justify the handle. User instructions From the off position, turn the diver ter lever clockwise or counter-clockwise to obtain water from either of the two functions. T urn the temperature control knob clockwise to make the water cooler . T urn it counter-clock- wise to make the water warmer . When turning the knob counter-clockwise, it will stop ...

  • Axor 06401XX0 - page 10

    10 1 cartridge with shutoff unit 88586000 2 thermostat car tridge 94282000 3 Solaris handle 88528XX0 4 Stratos handle 88543XX0 5 Metro handle 88548XX0 6 T alis handle 88549XX0 7 Cross handle 88608XX0 8 Scroll handle 88609XX0 9 Lever handle 88610XX0 10 Metris handle 11 Focus handle 12 escutcheon 13 Allegro² handle 14 Metro² handle XX = color code ...

  • Axor 06401XX0 - page 11

    11 Limited Lifetime Consumer W arranty This product has been manufactured and tested to the highest quality standards by Hansgrohe, Inc. (“Hansgrohe”). This warranty is limited to Hansgrohe products which are purchased by a consumer in the United States after March 1, 1996, and installed in either the United States or Canada. WHO IS COVERED BY ...

  • Axor 06401XX0 - page 12

    Hansgrohe, Inc. • 1490 Bluegrass Lakes Parkway • Alpharetta, GA 30004 T el. 770-360-9880 • Fax 770-360-9887 www .hansgrohe-usa.com US - Installation Instructions • Part No.90445601 • Revised 04/2008 THIS W ARRANTY DOES NOT COVER, AND HANSGROHE WILL NOT P A Y FOR: A. Conditions, malfunctions or damage not resulting from defects in material ...

Produzent Axor Kategorie Thermometer

Dokumente, die wir vom Produzenten des Geräts Axor 06401XX0 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Axor
- Bedienungsanleitungen 06401XX0
- Produktkarten Axor
- Informationsbroschüren
- oder Energieetiketten Axor 06401XX0
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Axor 06401XX0.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Axor 06401XX0, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Axor 06401XX0. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Axor 06401XX0 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Axor 06401XX0, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Axor 06401XX0 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Axor 06401XX0 verständlich ist.

Eine gänzliche Bedienungsanleitung von Axor sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Axor 06401XX0 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Axor 06401XX0 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Axor 06401XX0, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Axor 06401XX0 - die uns die ersten Schritte während der Nutzung von Axor 06401XX0 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Axor 06401XX0 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Axor 06401XX0 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Axor 06401XX0?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Axor 06401XX0 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Axor 06401XX0 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)