Bosch Appliances 100 Combi Boiler - page 1
Gas Condensing Boiler Bosch 100, 151 Combi Boiler 57, 100, 131, 151 Heating Boiler W ARNING: Improper installation, setup, modi fi cation, operation or maintenance of the heating syst em can cause personal injury and proper ty damage. F ollow each appliances' instructions precisely . F or assistance or further information, contact a trained a ...
-
Bosch Appliances 100 Combi Boiler - page 2
2 | Bosch Greenstar Applications Manual Bosch Thermot echnology Corp. Data subject to c hange ...
-
Bosch Appliances 100 Combi Boiler - page 3
Applications Manual Bosch Gr eenstar | 3 Bosch Thermot echnology Corp. Data subject to c hange T able of Contents 1 Information about the appliance 4 1.1 Boiler types and sizes 4 1.2 FW200 Boiler Energy Management 5 1.3 FB100 Remot e Control & Room Sensor 6 1.4 IPM2 Space Heating Module 7 1.5 ISM2 Solar Module 8 2 Applications 9 Legend 9 List o ...
-
Bosch Appliances 100 Combi Boiler - page 4
4 | Bosch Greenstar Applications Manual Bosch Thermot echnology Corp. Data subject to c hange 1 Information about the appliance 1.1 Boiler types and sizes Greenstar Heating boilers Greenstar 57: ZBR 16-3, 54,600btu (16kW) output Greenstar 100: ZBR 28-3, 95,500btu (28kW) output Greenstar 131: ZBR 35-3, 119,400btu (35kW) output Greens ...
-
Bosch Appliances 100 Combi Boiler - page 5
Applications Manual Bosch Gr eenstar | 5 Bosch Thermot echnology Corp. Data subject to c hange 1.2 FW200 Boiler Energy Management Syst em The Boiler Energy Management Syst em includes the FW200 user programming int er face with integrat ed outdoor reset contr ol. In connection with the IPM2 module the FW200 offers an outdoor reset contr ol ...
-
Bosch Appliances 100 Combi Boiler - page 6
6 | Bosch Greenstar Applications Manual Bosch Thermot echnology Corp. Data subject to c hange 1.3 FB100 Remote Contr ol & Room Sensor The FB100 can only be connect ed to sy stems with FW200 and a boiler with BUS-enabled Heatronic 3. The FB100 is a remot e room sensor and user interface that is used t o display de vice and syst em informatio ...
-
Bosch Appliances 100 Combi Boiler - page 7
Applications Manual Bosch Gr eenstar | 7 Bosch Thermot echnology Corp. Data subject to c hange 1.4 IPM2 Space Heating Module The IPM2 module operates pum ps and mixing valves of 2 heating zones. Each zone is run independently based on the programming and f eedback from the FB100 room sensor (if installed). Instead of a second zone a DHW recirculati ...
-
Bosch Appliances 100 Combi Boiler - page 8
8 | Bosch Greenstar Applications Manual Bosch Thermot echnology Corp. Data subject to c hange 1.5 ISM2 Solar Module The ISM2 module controls the com ponents of a solar thermal syst em. Integration of solar thermal with a boiler and central heating syst em for backup brings additional bene fi ts as it allow s minimizing boiler r un time and reduces ...
-
Bosch Appliances 100 Combi Boiler - page 9
Applications Manual Bosch Gr eenstar | 9 Bosch Thermot echnology Corp. Data subject to c hange 2 Applications Legend Greenstar boiler Greenstar combi-boiler Greenstar Greenstar pipe pipe Flow check valve Fig. 3 Legend NOTICE: All drawings in t his manual are conceptual in natur e and only depict components r elevant f or the syst ems shown. It is t ...
-
Bosch Appliances 100 Combi Boiler - page 10
10 | Bosch Greenstar Applications Manual Bosch Thermot echnology Corp. Data subject to c hange List of most common applications Single Zone Baseboard Syst ems: Syst em 1: Greenstar Heating Boiler in a single zone syst em (page 13-16). Syst em 2: Greenstar Combi-Boiler in a single zone syst em (page 17-20). Syst em 3: Greenstar Heating B ...
-
Bosch Appliances 100 Combi Boiler - page 11
Applications Manual Bosch Gr eenstar | 11 Bosch Thermot echnology Corp. Data subject to c hange Boiler pump capacity in single zone syst ems When installing the boiler in a single zone application without primar y/secondar y piping, it is critical not to overload t he pump. Use the Greenstar Heating or Combi Boiler in this setup only in lo w pressu ...
-
Bosch Appliances 100 Combi Boiler - page 12
12 | Bosch Greenstar Applications Manual Bosch Thermot echnology Corp. Data subject to c hange 02 5 7 8 14 36 15 20 25 10 5 0 H / ft . V / gpm 1 2 3 4 400 800 1200 1600 200 600 1000 1400 7 0 6 5 4 3 2 1 0 H / m . V / l/h 6 720 641 933-59.1O 1 2 3 4 02 13 5 46 8 7 15 20 25 10 5 0 H / ft . V / gpm 1 2 3 4 400 800 1200 1600 7 0 6 5 4 3 2 1 0 H / m . V ...
-
Bosch Appliances 100 Combi Boiler - page 13
Applications Manual Bosch Gr eenstar | 13 Bosch Thermot echnology Corp. Data subject to c hange 2.1 Syst em 1: Greenstar Heating Boiler in a single zone syst em Summar y: Single boiler supplying one baseboard heating zone equipped with FW200 outdoor rese t controller with built-in room sensor in the living space. This sy st em is using the boiler p ...
-
Bosch Appliances 100 Combi Boiler - page 14
14 | Bosch Greenstar Applications Manual Bosch Thermot echnology Corp. Data subject to c hange System 1 - Piping Diagram ...
-
Bosch Appliances 100 Combi Boiler - page 15
Applications Manual Bosch Gr eenstar | 15 Bosch Thermot echnology Corp. Data subject to c hange System 1 - Wiring Diagram ...
-
Bosch Appliances 100 Combi Boiler - page 16
16 | Bosch Greenstar Applications Manual Bosch Thermot echnology Corp. Data subject to c hange System 1: Setup and Pr ogramming In this single zone syst em the FW200 is installed in the living space in a location that repr esents the conditions of the entire zone. Av oid locations exposed to dir ect or indirect sunlight, heat sources, draft, etc. t ...
-
Bosch Appliances 100 Combi Boiler - page 17
Applications Manual Bosch Gr eenstar | 17 Bosch Thermot echnology Corp. Data subject to c hange 2.2 Syst em 2: Greenstar Combi Boiler in a single zone syst em Summar y: Single combi-boiler supplying one baseboard heating zone equipped with FW200 outdoor rese t controller with built-in room sensor in the living space. DHW generation directly off the ...
-
Bosch Appliances 100 Combi Boiler - page 18
18 | Bosch Greenstar Applications Manual Bosch Thermot echnology Corp. Data subject to c hange System 2 - Piping diagram ...
-
Bosch Appliances 100 Combi Boiler - page 19
Applications Manual Bosch Gr eenstar | 19 Bosch Thermot echnology Corp. Data subject to c hange System 2 - Wiring diagram ...
-
Bosch Appliances 100 Combi Boiler - page 20
20 | Bosch Greenstar Applications Manual Bosch Thermot echnology Corp. Data subject to c hange System 2: Setup and Pr ogramming In this single zone syst em the FW200 is installed in the living space in a location that repr esents the conditions of the entire zone. Av oid locations exposed to dir ect or indirect sunlight, heat sources, draft, etc. t ...
-
Bosch Appliances 100 Combi Boiler - page 21
Applications Manual Bosch Gr eenstar | 21 Bosch Thermot echnology Corp. Data subject to c hange 2.3 Syst em 3: Greenstar Heating Boiler in a single zone syst em with DHW tank loading Summar y: Single boiler supplying one baseboard heating zone equipped with FW200 outdoor rese t controller with built- in room sensor in the living space. This sy st e ...
-
Bosch Appliances 100 Combi Boiler - page 22
22 | Bosch Greenstar Applications Manual Bosch Thermot echnology Corp. Data subject to c hange System 3 - Piping diagram ...
-
Bosch Appliances 100 Combi Boiler - page 23
Applications Manual Bosch Gr eenstar | 23 Bosch Thermot echnology Corp. Data subject to c hange System 3 - Wiring diagram ...
-
Bosch Appliances 100 Combi Boiler - page 24
24 | Bosch Greenstar Applications Manual Bosch Thermot echnology Corp. Data subject to c hange System 3: Setup and Pr ogramming In this single zone syst em the FW200 is installed in the living space in a location that repr esents the conditions of the entire zone. Av oid locations exposed to dir ect or indirect sunlight, heat sources, draft, etc. t ...
-
Bosch Appliances 100 Combi Boiler - page 25
Applications Manual Bosch Gr eenstar | 25 Bosch Thermot echnology Corp. Data subject to c hange 2.4 System 4: Greenstar Heating Boiler in a single zone syst em with solar thermal DHW and boiler backup Summar y: Single boiler supplying one baseboard heating zone equipped with FW200 outdoor rese t controller with built- in room sensor in the living s ...
-
Bosch Appliances 100 Combi Boiler - page 26
26 | Bosch Greenstar Applications Manual Bosch Thermot echnology Corp. Data subject to c hange System 4 - Piping diagram R1 ...
-
Bosch Appliances 100 Combi Boiler - page 27
Applications Manual Bosch Gr eenstar | 27 Bosch Thermot echnology Corp. Data subject to c hange System 4 - Wiring diagram R1 ...
-
Bosch Appliances 100 Combi Boiler - page 28
28 | Bosch Greenstar Applications Manual Bosch Thermot echnology Corp. Data subject to c hange System 4: Setup and Pr ogramming In this single zone syst em the FW200 is installed in the living space in a location that repr esents the conditions of the entire zone. Av oid locations exposed to dir ect or indirect sunlight, heat sources, draft, etc. t ...
-
Bosch Appliances 100 Combi Boiler - page 29
Applications Manual Bosch Gr eenstar | 29 Bosch Thermot echnology Corp. Data subject to c hange 2.5 System 5: Greenstar Heating Boiler in a single zone syst em Summar y: Single boiler with primar y/secondar y piping con fi guration supplying one heating zone. Outdoor rese t with FW200 controller with built-in r oom sensor mounted in t he living sp ...
-
Bosch Appliances 100 Combi Boiler - page 30
30 | Bosch Greenstar Applications Manual Bosch Thermot echnology Corp. Data subject to c hange System 5 - Piping diagram ...
-
Bosch Appliances 100 Combi Boiler - page 31
Applications Manual Bosch Gr eenstar | 31 Bosch Thermot echnology Corp. Data subject to c hange System 5 - Wiring diagram ...
-
Bosch Appliances 100 Combi Boiler - page 32
32 | Bosch Greenstar Applications Manual Bosch Thermot echnology Corp. Data subject to c hange System 5: Setup and Pr ogramming In this single zone syst em the FW200 is installed in the living space in a location that repr esents the conditions of the entire zone. Av oid locations exposed to dir ect or indirect sunlight, heat sources, draft, etc. t ...
-
Bosch Appliances 100 Combi Boiler - page 33
Applications Manual Bosch Gr eenstar | 33 Bosch Thermot echnology Corp. Data subject to c hange 2.6 System 6: Greenstar Combi Boiler in a single zone syst em Summar y: Single combi-boiler supplying one heating zone. Outdoor reset wit h FW200 controller with built-in r oom sensor mounted in t he living space for r oom feedbac k. DHW generation direc ...
-
Bosch Appliances 100 Combi Boiler - page 34
34 | Bosch Greenstar Applications Manual Bosch Thermot echnology Corp. Data subject to c hange System 6 - Piping diagram ...
-
Bosch Appliances 100 Combi Boiler - page 35
Applications Manual Bosch Gr eenstar | 35 Bosch Thermot echnology Corp. Data subject to c hange System 6 - Wiring diagram ...
-
Bosch Appliances 100 Combi Boiler - page 36
36 | Bosch Greenstar Applications Manual Bosch Thermot echnology Corp. Data subject to c hange System 6: Setup and Pr ogramming In this single zone syst em the FW200 is installed in the living space in a location that repr esents the conditions of the entire zone. Av oid locations exposed to dir ect or indirect sunlight, heat sources, draft, etc. t ...
-
Bosch Appliances 100 Combi Boiler - page 37
Applications Manual Bosch Gr eenstar | 37 Bosch Thermot echnology Corp. Data subject to c hange 2.7 System 7: Greenstar Heating Boiler in a single zone syst em with DHW tank loading Summar y: Single boiler with primar y/secondar y piping con fi guration supplying one heating zone. Outdoor rese t with FW200 controller with built-in r oom sensor mou ...
-
Bosch Appliances 100 Combi Boiler - page 38
38 | Bosch Greenstar Applications Manual Bosch Thermot echnology Corp. Data subject to c hange System 7 - Piping diagram ...
-
Bosch Appliances 100 Combi Boiler - page 39
Applications Manual Bosch Gr eenstar | 39 Bosch Thermot echnology Corp. Data subject to c hange System 7 - Wiring diagram ...
-
Bosch Appliances 100 Combi Boiler - page 40
40 | Bosch Greenstar Applications Manual Bosch Thermot echnology Corp. Data subject to c hange System 7: Setup and Pr ogramming In this single zone syst em the FW200 is installed in the living space in a location that repr esents the conditions of the entire zone. Av oid locations exposed to dir ect or indirect sunlight, heat sources, draft, etc. t ...
-
Bosch Appliances 100 Combi Boiler - page 41
Applications Manual Bosch Gr eenstar | 41 Bosch Thermot echnology Corp. Data subject to c hange 2.8 System 8: Greenstar Heating Boiler in a single zone syst em with room thermostat and DHW tank loading Summar y: Single boiler with primar y/secondar y piping con fi guration supplying one heating zone. Outdoor rese t with FW200 controller mount ed o ...
-
Bosch Appliances 100 Combi Boiler - page 42
42 | Bosch Greenstar Applications Manual Bosch Thermot echnology Corp. Data subject to c hange System 8 - Piping diagram ...
-
Bosch Appliances 100 Combi Boiler - page 43
Applications Manual Bosch Gr eenstar | 43 Bosch Thermot echnology Corp. Data subject to c hange System 8 - Wiring diagram ...
-
Bosch Appliances 100 Combi Boiler - page 44
44 | Bosch Greenstar Applications Manual Bosch Thermot echnology Corp. Data subject to c hange System 8: Setup and Pr ogramming In this single zone syst em the FW200 is installed in the boiler for pur e outdoor reset wit hout room in fl uence. Install a suitable 3rd party thermostat in the living space in a location that repr esents the entire zon ...
-
Bosch Appliances 100 Combi Boiler - page 45
Applications Manual Bosch Gr eenstar | 45 Bosch Thermot echnology Corp. Data subject to c hange 2.9 System 9: Greenstar Heating Boiler in a single zone syst em with solar thermal DHW and boiler backup Summar y: Single boiler with primar y/secondar y piping con fi guration supplying one heating zone. Outdoor rese t with FW200 controller with built- ...
-
Bosch Appliances 100 Combi Boiler - page 46
46 | Bosch Greenstar Applications Manual Bosch Thermot echnology Corp. Data subject to c hange System 9 - Piping diagram R1 ...
-
Bosch Appliances 100 Combi Boiler - page 47
Applications Manual Bosch Gr eenstar | 47 Bosch Thermot echnology Corp. Data subject to c hange System 9 - Wiring diagram R1 ...
-
Bosch Appliances 100 Combi Boiler - page 48
48 | Bosch Greenstar Applications Manual Bosch Thermot echnology Corp. Data subject to c hange System 9: Setup and Pr ogramming In this single zone syst em the FW200 is installed in the living space in a location that repr esents the conditions of the entire zone. Av oid locations exposed to dir ect or indirect sunlight, heat sources, draft, etc. t ...
-
Bosch Appliances 100 Combi Boiler - page 49
Applications Manual Bosch Gr eenstar | 49 Bosch Thermot echnology Corp. Data subject to c hange 2.10 System 10: Greenstar Heating Boiler with zone pumps and room thermostats Summar y: Single boiler with primar y/secondar y piping con fi gura- tion supplying multiple heating zones. Outdoor rese t with FW200 controller mount ed on the boiler . 3rd p ...
-
Bosch Appliances 100 Combi Boiler - page 50
50 | Bosch Greenstar Applications Manual Bosch Thermot echnology Corp. Data subject to c hange System 10 - Piping diagram ...
-
Bosch Appliances 100 Combi Boiler - page 51
Applications Manual Bosch Gr eenstar | 51 Bosch Thermot echnology Corp. Data subject to c hange System 10 - Wiring diagram ...
-
Bosch Appliances 100 Combi Boiler - page 52
52 | Bosch Greenstar Applications Manual Bosch Thermot echnology Corp. Data subject to c hange System 10: Setup and Pr ogramming In this dual zone syst em the FW200 is installed in the boiler for pur e outdoor reset wit hout room in fl uence on the heating cur ve. Install suitable 3rd party thermostats in each zone in a location that best repr ese ...
-
Bosch Appliances 100 Combi Boiler - page 53
Applications Manual Bosch Gr eenstar | 53 Bosch Thermot echnology Corp. Data subject to c hange 2.11 System 11: Greenstar Heating Boiler with zone pumps, rela y panel, room thermostats and DHW tank loading Summar y: Single boiler with primar y/secondar y piping con fi guration supplying three heating zones contr olled by individual zone thermostat ...
-
Bosch Appliances 100 Combi Boiler - page 54
54 | Bosch Greenstar Applications Manual Bosch Thermot echnology Corp. Data subject to c hange System 11 - Piping diagram ...
-
Bosch Appliances 100 Combi Boiler - page 55
Applications Manual Bosch Gr eenstar | 55 Bosch Thermot echnology Corp. Data subject to c hange System 11 - Wiring diagram ...
-
Bosch Appliances 100 Combi Boiler - page 56
56 | Bosch Greenstar Applications Manual Bosch Thermot echnology Corp. Data subject to c hange System 11: Setup and Pr ogramming In this multi zone syst em the FW200 is installed in the boiler for pur e outdoor reset wit hout room in fl uence on the heating cur ve. Install suitable 3rd party thermostats in each zone in a location that best repr es ...
-
Bosch Appliances 100 Combi Boiler - page 57
Applications Manual Bosch Gr eenstar | 57 Bosch Thermot echnology Corp. Data subject to c hange 2.12 System 12: Greenstar Heating Boiler with zone valves and room thermostats Summar y: Single boiler with primar y/secondar y piping con fi gura- tion supplying three heating zones contr olled by 3rd par ty room thermostats with zone valv es. Outdoor ...
-
Bosch Appliances 100 Combi Boiler - page 58
58 | Bosch Greenstar Applications Manual Bosch Thermot echnology Corp. Data subject to c hange System 12 - Piping diagram ...
-
Bosch Appliances 100 Combi Boiler - page 59
Applications Manual Bosch Gr eenstar | 59 Bosch Thermot echnology Corp. Data subject to c hange System 12 - Wiring diagram ...
-
Bosch Appliances 100 Combi Boiler - page 60
60 | Bosch Greenstar Applications Manual Bosch Thermot echnology Corp. Data subject to c hange System 12: Setup and Pr ogramming In this multi zone syst em the FW200 is installed in the boiler for pur e outdoor reset wit hout room in fl uence on the heating cur ve. Z one control is handled b y a zone valve panel with r oom thermostats in each zone ...
-
Bosch Appliances 100 Combi Boiler - page 61
Applications Manual Bosch Gr eenstar | 61 Bosch Thermot echnology Corp. Data subject to c hange ...
-
Bosch Appliances 100 Combi Boiler - page 62
62 | Bosch Greenstar Applications Manual Bosch Thermot echnology Corp. Data subject to c hange ...
-
Bosch Appliances 100 Combi Boiler - page 63
Applications Manual Bosch Gr eenstar | 63 Bosch Thermot echnology Corp. Data subject to c hange ...
-
Bosch Appliances 100 Combi Boiler - page 64
United Stat es and Canada Bosch Thermotechnology Corp. 50 Wentw orth Avenue Londonderry, NH 03053 T el: 603-552-1100 F ax: 603-584-1681 www.bosch-climat e.us BTC 436001101 A / 07.2011 ...
¿Tienes una pregunta acerca de Bosch Appliances 100 Combi Boiler?
Utiliza el formulario que se encuentra abajo
Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Bosch Appliances 100 Combi Boiler, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Bosch Appliances 100 Combi Boiler probablemente compartirá una forma de solucionarlo.