Manual de instrucciones ResMed RPS II

16 de páginas 1.02 mb
Descargar

Pasar a la página of 16

Summary
  • ResMed RPS II - page 1

    Respiratory Care Solutions P o w er Station II BA TTERY P ACK User Guide English ...

  • ResMed RPS II - page 2

    P o w er Station II BA TTERY P ACK / AKKUP ACK / BA TTERIE / ALIMENT A TORE A BA TTERIA / BA TERÍA / BA TERIA / ACCU / BA TTERIP ACK / BA TTERIP AKKE / BA TTERIP AKKE / AKKU / ΜΠΑ ΤΑΡΙΑ / 电池包 / 電池包 2 1 2 3 8 4 5 6 7 9 B 1 2 3 C 1 2 3 4 5 6 7 a DC plug / Gleichstromstecker / F iche CC / Spinotto DC / Enchufe de C C / Ficha CC / ...

  • ResMed RPS II - page 3

    3 2 1 4 D * 3 4 5 2 1 6 E * 1 2 3b 3a * * Example device illustration only / Abbildung eines Beispielgerätes / Exemple d’appar eil / Illustrazione dell’apparecchio a solo titolo di esempio / Ilustración del dispositivo proporcionada a modo de ejemplo únicamente / Ilustração de dispositiv o apenas para exemplo / Uitsluitend voorbeeldillustr ...

  • ResMed RPS II - page 4

    i P o w er Station II DC output v oltage & DC cables 24V 26V DC Cable Par t Number VP AP ™ III ST -A  24959 VP AP ™ III ST -A with Quic kNav  24959 VP AP ™ Auto 25  24960 VP AP ™ S, VP AP ™ ST  24960 VP AP ™ IV , VP AP ™ IV S T  24960 S8 ™ Auto 25  24960 S9 ™ Series  24961 Stellar ™  24959 (24981 for ...

  • ResMed RPS II - page 5

    ii Svenska Obs! • Vissa utrustningar finns inte i alla delar a v världen. • För inf ormation om batteriernas körtider hän visas till Produktkompatibilitetslista för bat terier/ utrustningar på www .resmed.com. Dansk Bemærkninger: • Det er ikke alle apparater , der kan fås i alle lande. • Der er oplysninger om bat teriers driftstid ...

  • ResMed RPS II - page 6

    English 1 Intended use The R esMed P ower Station II (RPS II) is an external lithium-ion bat ter y that provides pow er when mains pow er is unav ailable. Please read the entire guide before using the RPS II. R ef er to the device user guides for intended patients, uses and contraindications associated with CP AP , bilev el and ventilation therap y ...

  • ResMed RPS II - page 7

    2 Set ting up CA UTION • Ensure the RPS II and the device are turned off before set ting up. • When the RPS II is plugged to the mains power supply , ensure all cables are properly connected. Charging the bat tery Ref er to illustration C . 1. At t ac h the pow er supply unit adapter to the DC plug and connect into the bat ter y DC input/output ...

  • ResMed RPS II - page 8

    English 3 2. Plug the bat ter y coupler cables into eac h of the bat ter y DC input/output ports. The bat ter y coupler cables are marked with ‘1’ (primar y) and ‘2’ (reser ve) labels. 3. a. When c harging t wo bat teries, at tach the po wer supply unit adapter to the DC plug and connect the adapter to the the bat ter y coupler . b. When po ...

  • ResMed RPS II - page 9

    4 Using humidifi ers When a device integrated with the HumidAire 2i ™ or H4i ™ humidifi er is not connected to the mains pow er supply , the humidifi er will only operate in passive unheated mode despite the warm-up message appearing on the de vice. When the device is connected to the mains pow er supply , it will return to activ e heated mo ...

  • ResMed RPS II - page 10

    English 5 T r oubleshooting If there is a problem, tr y the follo wing suggestions. If the problem cannot be solved, contact your equipment supplier or ResMed. Do not at tempt to open the bat ter y . Problem/P ossible cause Solution Device is not running P ower connections are disr upted. Chec k all cables and connect them as described in Set ting ...

  • ResMed RPS II - page 11

    6 T ec hnical specifications Bat ter y tec hnology Lithium ion Capacity < 1 0 0 Wh (97 Wh) UN classification UN3481 (lithium-ion bat teries pack ed with equipment) P ower supply Input range 1 00–240V , 50–60Hz, 1 .0-1 .5A Nominal for aircraf t use 1 1 0V , 40 0Hz Bat ter y output voltage (24V / 26V) ± 0.5V , 90W continuous P ower supply u ...

  • ResMed RPS II - page 12

    English 7 Symbols The f ollowing symbols ma y appear on the device or pac kaging: At tention, consult accompanying documents; Read instructions bef ore use; Drip proof; No protection; Class II equipment; European RoHS; Batc h Code; Serial number; Catalogue number; 8 Maximum humidity; T emperature limitation (storage and transport); Charging; Bat te ...

  • ResMed RPS II - page 13

    8 • Make sure to periodically recharge the bat tery due to effects of self- disc harging. • As the battery ages, the available capacity decreases. When the remaining battery capacity is get ting low, do not rely on the RPS II as the primary supply . • Ensure the internal battery of an y connected device is k ept c harged up to provide bac kup ...

  • ResMed RPS II - page 14

    English 9 Limited w arr anty ResMed Ltd (hereafter ’ResMed’) warrants that your ResMed product shall be free from defects in material and workmanship from the date of purchase for the period specified below. Product W arranty period • Mask systems (including mask frame, cushion, headgear and tubing)—e xcluding single-use de vices • Acces ...

  • ResMed RPS II - page 15

    10 This w arranty gives y ou specific legal rights, and you ma y also hav e other rights whic h vary from region to region. For further inf ormation on your w arranty rights, contact your local R esMed dealer or ResMed of fice. ...

  • ResMed RPS II - page 16

    Global leaders in sleep and respiratory medicine www .resmed.com 248527/2 20 1 2-07 P ow er Station II USER ROW MUL TI Respiratory Care Solutions Manufacturer: ResMed Ltd 1 Elizabeth Macarthur Drive Bella Vista NSW 2153 Australia. Distributed by: ResMed Corp 9001 Spectrum Center Boulevard San Diego CA 92123 USA. ResMed (UK) Ltd 96 Milton Park Abing ...

Fabricante ResMed Categoría Marine Instruments

Los documentos del dispositivo ResMed RPS II que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos ResMed
- manuales de instrucciones RPS II
- hojas de producto ResMed
- folletos informativos
- o etiquetas energéticas ResMed RPS II
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones ResMed RPS II.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje ResMed RPS II, instrucciones de servicio, instrucciones cortas o instrucciones de usuario ResMed RPS II. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto ResMed RPS II.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo ResMed RPS II, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar ResMed RPS II. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de ResMed RPS II.

El manual de instrucciones completo de ResMed debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual ResMed RPS II - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice ResMed RPS II, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de ResMed RPS II que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo ResMed RPS II - que deben facilitarnos los primeros pasos durante el uso de ResMed RPS II
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con ResMed RPS II
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de ResMed RPS II en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de ResMed RPS II?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con ResMed RPS II, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con ResMed RPS II probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)