    SYSTEM III ® OPERA TING & SER VICE MANU AL BUNN-O-MA TIC CORPORA TION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS 62708-3227 PHONE: (217) 529-6601 F AX: (217) 529-6644 27362.0000B 9/00 ©1996 Bunn-O-Matic Corporation BU N N ® ...

  • Bunn System III - page 2

    Page 2 W ARRANTY Bunn-O-Matic Corp. (“Bunn”) warrants the equipment manufactured by it to be commercially free from defects in material and workmanship existing at the time of manufacture and appearing within one year from the date of installation. In addition: 1.) Bunn warrants electronic circuit and/or control boards to be commercially free f ...

  • Bunn System III - page 3

    Page 3 20201.5600 00831.0000 ! WARNING HOT WATER 12364.0000 10044.0000 USER NOTICES Carefully read and follow all notices in this manual and on the equipment. The notices on this brewer should be kept in good condition. Replace any unreadable or damaged labels. 27362 092900 00656.0000 03408.0000 03409.0000 ...

  • Bunn System III - page 4

    Page 4 Electrical Hook-Up CAUTION – Improper electrical installation will damage electronic components. 1. An electrician must provide electrical service as specified. 2. Using a voltmeter, check the voltage and color coding of each conductor at the electrical source. 3. Remove the front panel beneath the sprayhead. Models with digital brewer con ...

  • Bunn System III - page 5

    Page 5 INITIAL SET -UP CAUTION – The brewer must be disconnected from the power source throughout the initial set-up, except when specified in the instructions. 1. Remove the front panel beneath the sprayhead. Models with digital brewer control assembly: Place the tank heater toggle switch at the bottom left of the control assembly in the "O ...

  • Bunn System III - page 6

    Page 6 T o decrease a batch size. Press and release the ST ART or BREW switch once for every two-second inter val to be removed from the total brew time period; then immediately press and hold down the ST ART or BREW switch until three clicks are heard. Release the switch. (Failure to release the switch within two seconds after the third click caus ...

  • Bunn System III - page 7

    Page 7 TROUBLESHOOTING A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic Technical Service Department. • Inspection, testing, and repair of electrical equipment should be performed only by ...

  • Bunn System III - page 8

    Page 8 Brew cycle will not start (cont.) Automatic refill will not operate Refer to Service - ON/OFF switch for testing procedures. See page 28 Refer to Service - Start switch for testing procedures. See page 32 Refer to Service - Timer for testing procedures. See page 34 or 35 Refer to Service - Dispense valve for testing procedures. See page 21 R ...

  • Bunn System III - page 9

    Page 9 Automatic refill will not operate (cont.) Beverage level will not adjust (Selec- tor switch in any position) Water flows into tank continuously (ON/OFF Switch "OFF") Water from tank is not hot Refer to Service - Solenoid valve for testing procedures. See page 30 Refer to Service - Selector switch for testing procedures. See page 16 ...

  • Bunn System III - page 10

    Page 10 TROUBLESHOOTING (cont.) Water from tank is not hot (cont.) Server warmer is not hot. Spitting or unusual steaming from sprayhead or airvent. Inconsistent beverage level in server. 5. Triac assembly (DBC) 1. ON/OFF switch 2. Warmer element 1. (A) Control thermostat (Electro/ mechanical) (B) Digital Brewer Control 2. Triac assembly (DBC) 3. L ...

  • Bunn System III - page 11

    Page 11 TROUBLESHOOTING (cont.) Inconsistent beverage level in server. (cont.) Consistently high or low beverage level in server. Dripping from sprayhead. Water overflows filter. Beverage overflows server. Weak beverage. 3. Dispense valve 1. (A) Time adjustment (Electro/ mechanical) (B) DBC volume adjustment 1. Dispense valve 1. Bypass valve (Elect ...

  • Bunn System III - page 12

    Page 12 TROUBLESHOOTING (cont.) Weak beverage (cont.) Brewer is making unusual noises. Temperature on the DBC display varies. 3. Sprayhead 4. Funnel loading 5. Water temperature 1. Solenoid (Inlet) 2. Plumbing lines 3. Water supply 4. Tank heater 5. Contactor 1. Digital brewer control B.O.M. sprayhead #01082.0002 should be used to properly wet the ...

  • Bunn System III - page 13

    Page 13 TROUBLESHOOTING (cont.) Cannot access the DBC DBC display is blank 1. Digital brewer control 1. Digital brewer control Refer to Service - Digital brewer con- trol for testing procedures. See page 22 step 7 Refer to Service - Digital brewer con- trol for testing procedures. See page 23 step 9 Problem Probable Cause Remedy 27362 092900 ...

  • Bunn System III - page 14

    Page 14 SERVICE This section provides procedures for testing and replacing various major components used in this brewer should service become necessary. Refer to Troubleshooting for assistance in determining the cause of any problem. WARNING - Inspection, testing, and repair of electri- cal equipment should be performed only by qualified service pe ...

  • Bunn System III - page 15

    Page 15 SERVICE (cont.) BYPASS VALVE Location: The bypass valve is located inside the hood on the left side just in front of the tank. Test Procedures: 1. Disconnect the brewer from the power source. 2. With a voltmeter, check the voltage across the white/green wire and the white/violet wire on the bypass valve. Connect the brewer to the power sour ...

  • Bunn System III - page 16

    Page 16 5. Reattach the connector to the brew timer circuit board or DBC connector. Grinder Interface: 6. Disconnect pink, gray and tan wires on the selector switch from the pink, gray and tan wires on the interface socket. 7. Check for continuity across the pink wire and the tan wire on the selector switch when the switch is in the 1 gallon positi ...

  • Bunn System III - page 17

    Page 17 SERVICE (cont.) BREW SELECTOR SWITCH (cont.) P1105.75 7. Install the knob so that the arrow lines up in the 2 gallon position when the switch is turned to the full right position. 8. Reattach the connector to the brew timer circuit board or DBC 9. Refer to Fig. 5 when reconnecting the wires. P1112.75 ELECTRO/MECHANICAL DIGITAL CONTROL (DBC) ...

  • Bunn System III - page 18

    Page 18 SERVICE (cont.) CONTACTOR ASSEMBLY (ELECTRO/MECHANICAL ONLY) Location: The contactor assembly is located inside the hood to the right of the overflow cup. Test Procedures: Mechanical Thermostat 1. Disconnect the brewer from the power source. 2. Disconnect the white wire or the red wire and the black wire of the contactor coil and disconnect ...

  • Bunn System III - page 19

    Page 19 Removal and Replacement: 1. Remove all wires from the contactor. 2. Remove the two #10-32 screws securing contactor to the inside of the hood. 3. Securely install the new contactor inside the hood. 4. Refer to Fig. 7 when reconnecting the wires. SERVICE (cont.) CONTACTOR ASSEMBLY (ELECTRO/MECHANICAL ONLY) (cont.) P1113 BLK T2 to Tank Heater ...

  • Bunn System III - page 20

    Page 20 SERVICE (cont.) P1098 CONTROL THERMOSTAT (ELECTRO/MECHANICAL ONLY) Location: The control thermostat is located inside the front of the brewer in the center of the component bracket. Test Procedures: 1. Disconnect the brewer from the power source. 2. With a voltmeter, check the voltage across the blue wires on the control thermostat and the ...

  • Bunn System III - page 21

    Page 21 DISPENSE VALVE N N x o p e r a t i n g p r e s s u r e l # 2 2 3 0 0 . 0 5 0 0 6 0 5 0 0 ) . 5 0 0 g p m F L O W J2 S ET L O C K L O CK SET T L 1 T L 2 T L 3 T L 4 T L 5 J 1 P2231.35 SERVICE (cont.) Location: Dispense valve is located inside the hood directly above the sprayhead. Test Procedures: 1. Disconnect the brewer from the power sour ...

  • Bunn System III - page 22

    Page 22 Location The digital control board is located inside the upper front of the trunk on the component bracket. The digital display is located in the upper center of the front of hood. NOTE: Check the function list (supplied) for FUNC- TION, ENTRY AND DESCRIPTION. 1. If display indicates a "FAULT" use the list below to troubleshoot th ...

  • Bunn System III - page 23

    Page 23 SERVICE (cont.) heater relay or triac. ("0" means the temperature will be allowed to vary by the value in "set relay temperature difference") 7. If you cannot access the DBC with the password you have entered, the password has been changed. If you know what the brew settings are you can "reset" the memory back ...

  • Bunn System III - page 24

    Page 24 P1099 P1094.35 Location The triac/heat sink is located on the lower rear of the brewer. Removal and Replacement NOTE - each triac installation requires the use of an approved silicone heat sink compound. Bunn-O- Matic recommends the use of Dow Corning 340 com- pound or equivalent. It can be purchased direct from Bunn-O-Matic (part number M2 ...

  • Bunn System III - page 25

    Page 25 SERVICE (cont.) LEVEL CONTROL BOARD AND LEVEL PROBE (Electro/ mechanical only) Location: The level control board is located inside the front of the brewer on the lower left side of the component bracket. The level probe is located inside the hood on the left center rear of the tank lid next to the limit thermostat. Test Procedure: 1. Discon ...

  • Bunn System III - page 26

    Page 26 LEVEL CONTROL BOARD AND LEVEL PROBE (Electro/ mechanical only)(cont.) P1100 SERVICE (cont.) b.) 200 to 240 volts ac for two wire 200 or 240 volt models after a delay of approximately 1 second. 17. Disconnect the brewer from the power source. If voltage is present as described, reinstall the probe, the level control board and level probe are ...

  • Bunn System III - page 27

    Page 27 Location: The limit thermostat is located inside the hood on the tank lid to the left of the tank heater. Test Procedure: 1. Disconnect the brewer from the power supply. 2. Disconnect both black wires from the limit ther- mostat. 3. With an ohmmeter, check for continuity across the limit thermostat terminals. If continuity is present as des ...

  • Bunn System III - page 28

    Page 28 SERVICE (cont.) ON/OFF (Warmer) SWITCH Location: The ON/OFF (Warmer) switch is located on the front of the hood to the right of the start switch. Test Procedure: 1. Disconnect the brewer from the power source. 2. Viewing the switch from the back remove the red or white wire from the upper right terminal and the black wire from the center te ...

  • Bunn System III - page 29

    Page 29 Removal and Replacement: 1. Disconnect the red leads from the overflow pro- tection switch from the black wire from the termi- nal block or DBC board assembly and the blue wire from the thermostat or red wire from DBC board assembly. 2. Remove the nut beneath the copper overflow cup. 3. Remove the entire switch assembly from the cup. 4. Pla ...

  • Bunn System III - page 30

    Page 30 SERVICE (cont.) SOLENOID VALVE (Refill) Location: The inlet solenoid valve is located inside the trunk on top of the flow control bracket. Test Procedure: 1. Disconnect the brewer from the power source. 2. Disconnect both wires from the solenoid valve coil terminals and check for continuity across the solenoid valve coil terminals. If conti ...

  • Bunn System III - page 31

    Page 31 SERVICE (cont.) SOLENOID VALVE (Refill) (cont.) P1107 9. Slide flow control bracket and solenoid as an assembly over flow control and secure with four #8-32 screws to the support bracket. 10. Securely fasten the water lines to and from the solenoid valve and flow control. 11. Refer to Fig. 24 when reconnecting the wires. WHI to Level Contro ...

  • Bunn System III - page 32

    Page 32 START SWITCH Location: The start switch is located in front of hood to the left of the ON/OFF switch. Test Procedure: 1. Disconnect the brewer from the power source and remove the wires from both terminals of the switch. 2. Check for continuity across the two terminals on the switch when it is held in the lower position. Continuity must not ...

  • Bunn System III - page 33

    Page 33 Location: The tank heater is located inside the hood on the right rear of the tank lid. Test Procedure: Electro/Mechanical Models. 1. Disconnect the brewer from the power supply. 2 With a voltmeter, check the voltage across the black and the red wire on the tank heater. With the control thermostat turned to the "ON" position (full ...

  • Bunn System III - page 34

    Page 34 SERVICE (cont.) TIMER (ELECTRO/MECHANICAL ONLY)(EARLY MODELS) tion. Select the 2 gallon batch setting. Connect the brewer to the power source and press the start switch. The indication must be: a.)120 volts ac for three wire 120/208 volt models and three wire 120/240 volt models for approxi- mately 1 minute 20 seconds for 2 gallon batch. b. ...

  • Bunn System III - page 35

    Page 35 SERVICE (cont.) DIGITAL TIMER (ELECTRO/MECHANICAL ONLY) (LATE MODELS) B U N N 9 0 p s ig m a x o p e ra ti n g p re s s u re S t ra in e r/ F lo w C o n t ro l # 2 2 3 0 0 . 0 5 0 0 (R e p l. F lo w W a s h e r # 2 0 5 2 6 . 0 5 0 0 ) ( R e p l. S c re e n # 2 3 7 2 1 . 0 0 0 0 ) . 5 0 0 g p m F L O W J 2 S E T L O C K L O CK SET T L 1 T L ...

  • Bunn System III - page 36

    Page 36 T imer Setting: NOTE: Prior to setting or modifying volumes, check that the brewer is connected to water supply , the tank is properly filled, and a funnel and server are in place. NOTE: All volume settings must be done with the sprayhead installed. NOTE: The timer must be adjusted for each individual batch setting. 1. Modifying brew volume ...

  • Bunn System III - page 37

    Page 37 4. Disconnect wires from the warmer element. 5. Check the continuity across the two terminals on the warmer element. If continuity is present as described, reconnect the white or red wire and white/red wires, or the white or red wire and white/violet wires on the warmer element. If continuity is not present as described, replace the warmer ...

  • Bunn System III - page 38

    Page 38 LOWER 27362 092900 ...

  • Bunn System III - page 39

    Page 39 27362 092900 ...

  • Bunn System III - page 40

    Page 40 LOWER 27362 092900 ...

Fabricante Bunn Categoría Coffeemaker

Los documentos del dispositivo Bunn System III que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Bunn
- manuales de instrucciones System III
- hojas de producto Bunn
- folletos informativos
- o etiquetas energéticas Bunn System III
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Bunn System III.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Bunn System III, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Bunn System III. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Bunn System III.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Bunn System III, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Bunn System III. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Bunn System III.

El manual de instrucciones completo de Bunn debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Bunn System III - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Bunn System III, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Bunn System III que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Bunn System III - que deben facilitarnos los primeros pasos durante el uso de Bunn System III
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Bunn System III
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Bunn System III en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Bunn System III?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Bunn System III, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Bunn System III probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)