  • Athena Technologies P - page 1

    DIGIT AL TEMPERA TURE CONTR OLLERS SERIES O TC25 N/L/P Instruction Manual ...

  • Athena Technologies P - page 2

    Congratulations on your purchase of an Athena Series OTC25 Digital T emperature Controller . It is designed for ease of use and reliability wherever accurate temperature control is required. After following the instructions for installation, simply step through and set each of the unit’ s parameters using the OTC25’ s easy menu system. If you s ...

  • Athena Technologies P - page 3

    T able of Contents Installation 1 Mounting 1 Wiring 2 Operation 2 OTC25 N On/Off Controller 4 OTC25 L Limit Controller 5 OTC25 P PID Controller 7 Calibration 10 Error Codes 11 IEC Requirements 11 W arranty/Repair Information 12 T echnical Specifications 14 ...

  • Athena Technologies P - page 4

    1 Installation Pre-Installation Instructions 1. Inspect shipping carton for obvious signs of mishandling. 2. After removing the controller from the shipping carton, inspect it carefully for damage. Never attempt to install and use a damaged unit. 3. Verify that the ordering code number indicated on the side of the controller matches what was ordere ...

  • Athena Technologies P - page 5

    2 Operation Athena Series OTC25 Digital T emperature Controller Just a few easy steps are required before your OTC25 can be placed into service. After completing the mounting and wiring procedures as previously instructed, set each controller parameter using the simple front-panel keys as instructed. Power On When power is first applied to the OTC2 ...

  • Athena Technologies P - page 6

    O TC25 N Operation F igure 5a. Series O TC25 N Parameters and Default Settings Parameter Descriptions Default Display This parameter determines whether the OTC25 N’ s display shows the Setpoint or the actual temperature by default. Regardless of the selection made here, the operator can observe the other value by momentarily pressing the Paramete ...

  • Athena Technologies P - page 7

    O TC25 N Operation The Calibration High and Calibration Low selections ar e accessi- ble only when the calibration jumper is installed as instructed on page 10 (F igure 6). OTC25 N On/Off T emperature Controller Normal Operation The factory default display setting of the OTC25 N is for Actual Te mperature . The default display may be changed to set ...

  • Athena Technologies P - page 8

    5 O TC25 L Operation OTC25 L Limit Controller Normal Operation The factory default display setting of the OTC25 L is for Actual Te mperature . The default display may be changed to setpoint temperature by selecting Limit Setpoint at the Default Display parameter selection. When the Default Display is changed to Limit Setpoint, the limit setpoint te ...

  • Athena Technologies P - page 9

    6 O TC25 L Operation Parameter Descriptions Default Display This parameter determines whether the OTC25 L ’ s display shows the Limit Setpoint or the actual temperature by default. Regardless of the selection made here, the operator can observe the other value by momentarily pressing the Parameter Key . This will cause the alternate value to be d ...

  • Athena Technologies P - page 10

    7 O TC25 P Operation OTC25 P PID T emperature Controller Normal Operation The factory default display setting of the OTC25 P is for Actual Te mperature . The default display may be changed to setpoint temperature by selecting Setpoint at the Default Display parameter selection. When the Default Display is changed to Setpoint, the setpoint temperatu ...

  • Athena Technologies P - page 11

    F igure 5c. Series O TC25 P Parameters and Default Settings Parameter Descriptions Default Display This parameter determines whether the OTC25 P’ s display shows the Setpoint or the actual temperature by default. Regardless of the selection made here, the operator can observe the other value by momentarily pressing the Parameter Key . This will c ...

  • Athena Technologies P - page 12

    O TC25 P Operation Proportional Band Proportional Band is a PID parameter that represents the amount of deviation of the controlled variable required to move through the full range, expressed in % of span or degrees of temperature. This para- meter can also be expressed as “Gain” (the wider the band, the lower the gain). Rate Rate is a PID para ...

  • Athena Technologies P - page 13

    10 Calibration Procedure 1. Prior to applying power to the unit, install the calibration jumper on the microprocessor board as shown in Figure 6. 2. With the instrument still unpowered, connect a calibration reference source to the thermocouple input terminals on the OTC25. 3. Apply power . Allow at least 15 minutes for the controller to warm up be ...

  • Athena Technologies P - page 14

    The maximum supply current is line voltage dependent: 60 mA for an 100-250 Vac input fuse rating: 2AG, 0.5 A Output Specifications Output 1 T ype Max current Voltage Leakage T (T riac) 2 A 400 Vpk 1 mA B (Relay) 5 A 380 V — Output 2 T ype Max current Voltage Leakage T (SSR) 0.5 A 400 Vpk 1 mA B (Relay) 5 A 380 V — CLEANING INSTRUCTIONS 1. Remov ...

  • Athena Technologies P - page 15

    12 W arranty/Repair Inf ormation T wo-Y ear Limited Warranty THIS EQUIPMENT IS WARRANTED TO BE FREE FROM DEFECTS OF MA TERIAL AND WORKMANSHIP . IT IS SOLD SUBJECT TO OUR MUTUAL AGREEMENT THA T THE LIABILITY OF A THENA CONTROLS, INCORPORA TED IS TO REPLACE OR REPAIR THIS EQUIPMENT A T ITS FACTOR Y , PROVIDED THA T IT IS RETURNED WITH TRANSPORT A TIO ...

  • Athena Technologies P - page 16

    13 W arranty/Repair Inf ormation Unit Repairs It is recommended that units requiring service be returned to an authorized service center . Before a controller is returned for ser- vice, please consult the service center nearest you. In many cases, the problem can be cleared up over the telephone. When the unit needs to be returned, the service cent ...

  • Athena Technologies P - page 17

    14 Mechanical Characteristics Display 7-segment LED, alphanumeric: 3 digits Display Height 0.56" (14.22 mm) Color Orange Front-Panel Cutout 3.622" x 3.622" (92 mm x 92 mm) Bezel Outside Dimensions 3.780" x 3.780" (96 mm x 96 mm) Bezel Height 0.250" (6.35 mm) Case Depth 3.515" (89.28 mm) Weight < 15 oz (425 g) C ...

  • Athena Technologies P - page 18

    15 T echnical Specif ications Input Source (T emperature Sensor) Thermocouple Range: T ype J OTC25 N/L: 6 to 926° F (-14 to 496° C) OTC25 P: 32 to 999° F (0 to 537° C) T ype K OTC25 N/L: N/A OTC25 P: 0 to 999° F (-17 to 537° C) Output Source (Power to Heater) Solid-State Relay (Output 1) 120/250 Vac, Zero-V oltage Switched, 2 A Continuous/ 10 ...

  • Athena Technologies P - page 19

    16 NO TES ...

  • Athena Technologies P - page 20

    17 Keep This Information in a Safe Place Configured Parameters Reference Information Series OTC25 T emperature Controller Model Number: _____________________ Zone Location: _____________________ Firmware V ersion No. : _______________ (Displayed when the controller is powered up after all the segments on both lines of the display have been tested). ...

  • Athena Technologies P - page 21

    18 NO TES ...

  • Athena Technologies P - page 22

    19 Keep This Information in a Safe Place Configured Parameters Reference Information Series OTC25 T emperature Controller Model Number: _____________________ Zone Location: _____________________ Firmware V ersion No. : _______________ (Displayed when the controller is powered up after all the segments on both lines of the display have been tested). ...

  • Athena Technologies P - page 23

    20 NO TES ...

  • Athena Technologies P - page 24

    For technical assistance, call toll free 1-800-782-6776 (in the U .S.) or 610-828- 2490 (fr om an ywhere in the w orld), or e-mail techsupport@athenacontrols.com. Athena Controls, Inc. 5145 Campus Drive Plymouth Meeting, P A 19462 USA T oll-free: 800.782.6776 T el: 610.828.2490 Fax: 610.828.7084 techsupport@athenacontrols.com athenacontrols.com 900 ...

Fabricante Athena Technologies Categoría Weather Radio

Los documentos del dispositivo Athena Technologies P que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Athena Technologies
- manuales de instrucciones P
- hojas de producto Athena Technologies
- folletos informativos
- o etiquetas energéticas Athena Technologies P
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Athena Technologies P.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Athena Technologies P, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Athena Technologies P. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Athena Technologies P.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Athena Technologies P, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Athena Technologies P. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Athena Technologies P.

El manual de instrucciones completo de Athena Technologies debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Athena Technologies P - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Athena Technologies P, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Athena Technologies P que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Athena Technologies P - que deben facilitarnos los primeros pasos durante el uso de Athena Technologies P
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Athena Technologies P
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Athena Technologies P en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Athena Technologies P?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Athena Technologies P, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Athena Technologies P probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)