    IPmux-11 TDM Pseudowire Access Gateway Version 2.00 Installation and Operation Manual Notice T h i s m a n u a l c o n t a i n s i n f o r m a t i o n t h a t i s p r o p r i e t a r y t o R A D D a t a C o m m u n i c a t i o n s L t d . ( " R A D " ) . N o part of this publication may be reproduced in any form whatsoever without prior w ...

  • RAD Data comm IPmux-11 - page 4

    Limited Warranty RAD warrants to DISTRIBUTOR that the hardware in the I Pmux -11 to be delivered hereunder shall be free of defects in material and workmans hip under no rmal use and service for a period of twelve (12) months following the date of shipment to DISTRIBUTOR. If, during the warranty period, any component part of the equipment becomes d ...

  • RAD Data comm IPmux-11 - page 5

    Product Disposal To facilitate the reuse, recycling and ot her forms of recovery of waste equipment in protecting the environm ent, the owner of this RAD product is required to refrain from disposing of this pr oduct as unsorted municipal waste at the end of its life cycle. Upon termination of the unit’s use, customers should provide for its coll ...

  • RAD Data comm IPmux-11 - page 6

    In some cases, the users may insert their own SFP la ser transceivers into the product. Users are alerted that RAD cannot be held responsible for any damage th at may result if non-compliant transceivers are used. In particular, users are warned to use only age ncy approved pro ducts that comply with the local laser safety regulations fo r Class 1 ...

  • RAD Data comm IPmux-11 - page 7

    The maximum permissible current capability of the branch distribution circuit that supplies power to th e product is 16A. The circuit breaker in the building installatio n should have high breaki ng capacity and m ust operate at short-circuit current exceeding 35A. Before connecting the DC su pply wires, ensure that power i s removed from the DC ci ...

  • RAD Data comm IPmux-11 - page 8

    Some SELV and non-SELV circuits use the same connectors. Use caution when connecting cables. Extra caution should be exer cise d during thunderstorms. When using shielded or coaxial cables, verify that there is a good ground connection at both ends. The earthing and bonding of the ground connectio ns should comply with the local codes. The telecomm ...

  • RAD Data comm IPmux-11 - page 9

    FCC-15 User Information This equipment has been tested and found to comply with the limits of the Class A digital device, pursuant to Part 15 of the FCC rules. These limi ts are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can ra ...

  • RAD Data comm IPmux-11 - page 10

    Declaration of Conformity Manufacturer's Name: RAD Data Communications Ltd. Manufacturer's Address: 24 Raoul Wallenberg St. Tel Aviv 69719 Israel declares that the product: Product Name: IPmux-11 conforms to the following standard(s ) or other normative document(s): EMC : EN 55022: 1998 Information techno logy equipment – Radio disturba ...

  • RAD Data comm IPmux-11 - page 11

    IPmux-11 Ver. 2.00 Configuring IPmux-11 1 Quick Start Guide Installation of IPmux-11 should be carrie d out only by an experienced technician. If you are familiar with IPmux-11, use this guide to prepare the unit for operation. 1. Installing IPmux-11 Connecting the Interfaces 1. Connect the network to the RJ-45 connector designated ETH 1. 2. Connec ...

  • RAD Data comm IPmux-11 - page 12

    Quick Start Guide Installation and Operation Manual 2 Configuring IPmux-11 IPmux-11 Ver. 2.00 Configuring the IP Management Parameters The host IP address, subnet mask and default gateway IP address must be configured via an ASCII terminal.  To configure the IP management parameters: • From the Host IP menu ( Main > Configuration > Syste ...

  • RAD Data comm IPmux-11 - page 13

    IPmux-11 Ver. 2.00 i Contents Chapter 1. Introduction 1.1 Overview ..................................................................................................................... 1-1 Versio ns ....................................................................................................................... ......... 1-1 Applicat ion .... ...

  • RAD Data comm IPmux-11 - page 14

    Table of Contents Installation an d Operation M anual ii IPmux-11 Ver. 2.00 Chapter 4. Configuration 4.1 Configuration Sequence .............................................................................................. 4-1 4.2 Configuring IPmux-11 for Management ....................................................................... 4-2 Configu ...

  • RAD Data comm IPmux-11 - page 15

    IPmux-11 Ver. 2.00 Overview 1-1 Chapter 1 Introduction 1.1 Overview IPmux-11 offers a solution for extendin g tradit ional E1/T1 transparently over packet switched networks (PSNs) such as IP, Ethernet, and MPLS networks. The device converts the data stream coming from its TDM ports into configura ble-sized packets that are extended over the Fast Et ...

  • RAD Data comm IPmux-11 - page 16

    Chapter 1 Introduction Installation and Operation Manual 1-2 Overview IPmux-11 Ver. 2.00 Application Figure 1-1 ill ustrates a typical IPmux-11 multiplexing voice and Ethernet traffic over an IP link. Figure 1-1. Multiplexing Voice and Et hernet over a Packet-Switched Network Features E1 Interface The E1 port complies with G.703, G.7 04, and G.823 ...

  • RAD Data comm IPmux-11 - page 17

    Installation and Operation Manual Chapter 1 Introduction IPmux-11 Ver. 2.00 Overview 1-3 IP The data stream coming from the E1 or T1 port is converted into IP packets that are transported over the Fast Ethernet ports, and vice versa. TDM bytes are encapsulated in a UDP frame that runs over IP an d over Ethernet. The number of TDM bytes in an IP fra ...

  • RAD Data comm IPmux-11 - page 18

    Chapter 1 Introduction Installation and Operation Manual 1-4 Overview IPmux-11 Ver. 2.00 QoS QoS supports: • Labeling IP level priority (ToS/Diffserv) for TDMoIP packets • VLAN tagging and priority labeling according to IEEE 802.1p&Q for TD MoIP packets • QoS marking of the TDMoIP traffic in MPLS networks. The user can configure the ToS ( ...

  • RAD Data comm IPmux-11 - page 19

    Installation and Operation Manual Chapter 1 Introduction IPmux-11 Ver. 2.00 Functional Description 1-5 1.2 Physical Description IPmux-11 is a compact easy-to-install standalone unit. Figure 1-2 shows a 3-dimens ional view of IPmu x-11. Figure 1-2. IPmux-11 3D View The front panel includes the IPmux-11 LEDs . For the detailed LED description, see Ch ...

  • RAD Data comm IPmux-11 - page 20

    Chapter 1 Introduction Installation and Operation Manual 1-6 Functional Description IPmux-11 Ver. 2.00 Unframed In the unframed mode, the incoming bit st ream from each channel (regardless of framing) is converted into IP over Eth e rnet frames. This option provides clear channel end-to-end se rvice (unframed). Fractional In the fractional mode, th ...

  • RAD Data comm IPmux-11 - page 21

    Installation and Operation Manual Chapter 1 Introduction IPmux-11 Ver. 2.00 Functional Description 1-7 • Internal timing – in this mode, the Tx clock is derived from an internal oscillator. • External timing – in this mode the Tx clock is derived from the external clock input. The external clock port also outputs the input clock signal to a ...

  • RAD Data comm IPmux-11 - page 22

    Chapter 1 Introduction Installation and Operation Manual 1-8 Functional Description IPmux-11 Ver. 2.00 Figure 1-4. IPmux-11 in Ex ternal Clock Mode Single Source Clock Network When a common clock is not available on all the ends of the network, one of the IPmux-11 devices is configured to work in loopback timing, while the other IPmux-11device is c ...

  • RAD Data comm IPmux-11 - page 23

    Installation and Operation Manual Chapter 1 Introduction IPmux-11 Ver. 2.00 Functional Description 1-9 Table 1-2. TDMoIP Frame Structure Field Length (Bytes) Field 7 Preamble 1 SFD 6 Destination MAC Address 6 Source MAC Address 2 Type 1 Vers/HLEN 1 Service Type 2 Total Length 2 Identification 1 Flags/Fragment Offset (most) 1 Fragment Offset (least) ...

  • RAD Data comm IPmux-11 - page 24

    Chapter 1 Introduction Installation and Operation Manual 1-10 Functional Description IPmux-11 Ver. 2.00 VLAN Support VLAN, according to IEEE 802.1p& Q, adds four byt es to the MAC layer of the Ethernet frame. The user can set the cont ents of these bytes, MAC layer priority and VLAN ID. In this mode, only VLAN fo rmat frames are sent and receiv ...

  • RAD Data comm IPmux-11 - page 25

    Installation and Operation Manual Chapter 1 Introduction IPmux-11 Ver. 2.00 Functional Description 1-11 Table 1-4. TDMoMPLS Frame Structure Field Length (Bytes) Field 7 Preamble 1 SFD 6 Destination MAC Address 6 Source MAC Address 2 Type 20 Outer label 3 EXP 1 Stacking bit 8 TTL 20 Inner label 3 EXP 1 Stacking bit 8 TTL ... Payload 4 CRC Packet Del ...

  • RAD Data comm IPmux-11 - page 26

    Chapter 1 Introduction Installation and Operation Manual 1-12 Functional Description IPmux-11 Ver. 2.00 PDVT (Jitter) Buffer IPmux-11 is equipped with a Packet DVT (Delay Variation Tol erance) buffer. The PDVT buffer or jitter buffer is filled by the incoming IP packets and emptied out to fill the TDM stream. The buffer begin s to empty out only a ...

  • RAD Data comm IPmux-11 - page 27

    Installation and Operation Manual Chapter 1 Introduction IPmux-11 Ver. 2.00 Functional Description 1-13 Configuring the TDM byt es per frame (TDM bytes/frame) parameter has impact on the Ethernet throughput (bandwidth or traf fic traveling through the Ethernet). This parameter controls the number of TDM bytes enc apsulated in one frame. The TDM byt ...

  • RAD Data comm IPmux-11 - page 28

    Chapter 1 Introduction Installation and Operation Manual 1-14 Functional Description IPmux-11 Ver. 2.00 Where: • VLAN is an optional field: if enabled it adds 4 bytes to the frame overhead • payload = number of TDM bytes in frame, (48, 96, 144, 19 2, … 1440) • frame overhead = size of 46 bytes, include MAC, LLC, IP and UDP layer • CAS is ...

  • RAD Data comm IPmux-11 - page 29

    Installation and Operation Manual Chapter 1 Introduction IPmux-11 Ver. 2.00 Functional Description 1-15 For V1 the maximum number of frames that can be reordered is 7, even if the calculation result exceeds 7. For V2 th e maximum number of frames that can be reordered is 64, even if t he ca lculation result exceeds 64. Duplicated Frames When frames ...

  • RAD Data comm IPmux-11 - page 30

    Chapter 1 Introduction Installation and Operation Manual 1-16 Functional Description IPmux-11 Ver. 2.00 IPmux-11 transfers fault condit ions only if the payload format is configured to V2. The fault conditions are transferre d as follows: • Framed E1 or T1: RDI as RDI, LOS and AIS as AIS • Unframed E1 or T 1: LOS and AIS as AIS. VLAN Traffic Be ...

  • RAD Data comm IPmux-11 - page 31

    Installation and Operation Manual Chapter 1 Introduction IPmux-11 Ver. 2.00 Functional Description 1-17 Internal Swi tch TDMo IP E1 o r T1 P ort Et hernet Networ k Port Et hernet User Port 1 Et hernet User Port 2 Figure 1-11. IPmux-11 with Two Ethernet User Port Priority is always given to TDMoIP packets insi de the internal switch. Switch Operatio ...

  • RAD Data comm IPmux-11 - page 32

    Chapter 1 Introduction Installation and Operation Manual 1-18 Functional Description IPmux-11 Ver. 2.00 Table 1-7. Automatic Per-Port Rate Limiting Default VLAN Priority Automatic Rate Limiting 4 - 7 64 Mbps 2 - 3 32 Mbps 0 - 1 16 Mbps Table 1-8 illustrates relations between rate limiting and VLAN tagging modes. Table 1-8. Rate Limitin g and VLAN T ...

  • RAD Data comm IPmux-11 - page 33

    Installation and Operation Manual Chapter 1 Introduction IPmux-11 Ver. 2.00 Functional Description 1-19 Switch Behavior When Handling User and Network Traffic The way the network and user ports handle the traffic depends on the selected port mode (transparent , untagged, tagged or double tagged) and fra me type (untagged, tagged or double tagged). ...

  • RAD Data comm IPmux-11 - page 34

    Chapter 1 Introduction Installation and Operation Manual 1-20 Functional Description IPmux-11 Ver. 2.00 Table 1-12. Mode C Ingress Egress If a tagged frame enters the transparent port, it is switched to the tagged port • If the tagged port is not a member of the frame’s VID, the frame is disc arded • The tagged port is a member of the frame? ...

  • RAD Data comm IPmux-11 - page 35

    Installation and Operation Manual Chapter 1 Introduction IPmux-11 Ver. 2.00 Functional Description 1-21 Table 1-14. Mode E Ingress Egress If a tagged frame enters the untagged port, it is switched to the tagged port If the tagged port is not a member of the frame VID, the frame is discarde d If the tagged port is a member of the frame VID, the fram ...

  • RAD Data comm IPmux-11 - page 36

    Chapter 1 Introduction Installation and Operation Manual 1-22 Functional Description IPmux-11 Ver. 2.00 Table 1-16. Mode G Ingress Egress If a double-tagged frame enters the transparent port, it is switched to the double-tagged port • If the double-tagged port is not a member of the first VID of the frame, the frame is discarded • If the double ...

  • RAD Data comm IPmux-11 - page 37

    Installation and Operation Manual Chapter 1 Introduction IPmux-11 Ver. 2.00 Functional Description 1-23 Switch Behavior When Hand ling Management Traffic Table 1-17 lists operation modes of the network port when handl ing the management traffic. Table 1-17. Switch Behavior (Management Traffic) Port Option Transparent Untagged Tagged Double-Tagg ed ...

  • RAD Data comm IPmux-11 - page 38

    Chapter 1 Introduction Installation and Operation Manual 1-24 Technical Specifications IPmux-11 Ver. 2.00 1.4 Technical Specifications E1 Interface Compliance ITU-T Rec. G.703, G.704 , G.706, G.732, G.82 3 Data Rate 2.048 Mbps Line Code HDB3 Framing Unframed, framed, multiframe ; with or without CRC-4 Signaling CAS, CCS (transparent) Line Impedance ...

  • RAD Data comm IPmux-11 - page 39

    Installation and Operation Manual Chapter 1 Introduction IPmux-11 Ver. 2.00 Technical Specifications 1-25 Timing Transmit • Internal • External input or output via dedicated connector: E1/T1 or 2048/1544 kHz squarewave (RS-485 electrical levels) • Loopback • Adaptive Pseudowire Connections Number of Connections 1 Jitter Buffer Size 3–300 ...

  • RAD Data comm IPmux-11 - page 40

    Chapter 1 Introduction Installation and Operation Manual 1-26 Technical Specifications IPmux-11 Ver. 2.00 ...

  • RAD Data comm IPmux-11 - page 41

    IPmux-11 Ver. 2.00 Site Requirements and Prerequisites 2-1 Chapter 2 Installation and Setup 2.1 Introduction This chapter describes installation and se tup procedures for the IPmux-11 unit. After installing the unit, re fer to Chapter 3 for the operating instructions. If a problem is encountered, refer to Chapter 6 for test and diagnostic instructi ...

  • RAD Data comm IPmux-11 - page 42

    Chapter 2 Installation and Setup Installation and Operation Manual 2-2 Connecting the Ethernet Equipment IPmux-11 Ver. 2.00 2.3 Package Contents The IPmux-11 package includ es the following items: • One IPmux-11 unit • Power cord • IEC 60320 AC/DC adapter plug • CBL-DB9F-DB9M-STR control po rt cable (if ordered) • CBL-RJ45/2BNC/E1/X a dap ...

  • RAD Data comm IPmux-11 - page 43

    Installation and Operation Manual Chapter 2 Installation and Setup IPmux-11 Ver. 2.00 Connecting to the E1/T1 Devices 2-3 Connecting the Ethernet User Equi pment Figure 2-3 illustrates a rear panel of th e IPmux-11 unit with two user LAN ports. CO NTRO L EXT C LK E1 ETH 123 SET DEF Figure 2-3. E TH 2 and ETH 3 Co nnectors  To connect to the Ethe ...

  • RAD Data comm IPmux-11 - page 44

    Chapter 2 Installation and Setup Installation and Operation Manual 2-4 Connecting IPmux-11 to Power IPmux-11 Ver. 2.00 2.6 Connecting to the External Clock Source IPmux-11 is connected to the external clock source via a balance d RJ-45 connector designated EXT CLK. Re fer to Appendix A for the connector pinout. CO NTRO L EXT C LK E1 ETH 123 SET DEF ...

  • RAD Data comm IPmux-11 - page 45

    Installation and Operation Manual Chapter 2 Installation and Setup IPmux-11 Ver. 2.00 Connecting IPmux-11 to Power 2-5 Before connecting or disconnecting any cable, t he protective earth terminals of this unit must be connected to the protective ground conductor of the mains (AC or DC) power cord. If you are u sing an extension cord (power cabl e) ...

  • RAD Data comm IPmux-11 - page 46

    Chapter 2 Installation and Setup Installation and Operation Manual 2-6 Connecting IPmux-11 to Power IPmux-11 Ver. 2.00 ...

  • RAD Data comm IPmux-11 - page 47

    IPmux-11 Ver. 2.00 Controls and Indicators 3-1 Chapter 3 Operation This chapter: • Provides a detailed description of the front panel c ontrols and indicators a nd their functions • Explains power-on and po wer-off procedures • Provides instructions for config uration using a termi nal connected to the IPmux-11 control port • Provides instr ...

  • RAD Data comm IPmux-11 - page 48

    Chapter 3 Operation Installation and Operation Manual 3-2 Controls and Indicators IPmux-11 Ver. 2.00 Table 3-1. IPmux-11 LED s and Controls Name Type Function Location PWR Green LED ON – Power is ON Front panel ALM Red/yellow LED ON (red) – Active alarm is stored in the log file ON (yellow) – An alarm is present in the log file OFF – No ala ...

  • RAD Data comm IPmux-11 - page 49

    Installation and Operation Manual Chapter 3 Operation IPmux-11 Ver. 2.00 Default Settings 3-3 3.3 Default Settings The following table lists the default settings of the IPmux-11 co nfiguration parameters. Table 3-2. Default Settings Parameter Default Value System IP address Empty IP mask Empty Default gateway 0.0.0.0 DHCP status Enable Authenticati ...

  • RAD Data comm IPmux-11 - page 50

    Chapter 3 Operation Installation and Operation Manual 3-4 Default Settings IPmux-11 Ver. 2.00 Table 3-2. Default Settings (Cont.) Parameter Default Value Fall back clock source Port1 Master clock Ex ternal Fall back clock Internal Physical Layer (T DM, E1) Admin status Enable Transmit clock source Adaptive Loopback state Disable Rx sensitivity Shor ...

  • RAD Data comm IPmux-11 - page 51

    Installation and Operation Manual Chapter 3 Operation IPmux-11 Ver. 2.00 Default Settings 3-5 Table 3-2. Default Settings (Cont.) Parameter Default Value Trail mode Termination Physical Layer (ETH) Channel state Enable Auto negotiation • Disable for fiber optic interf ace • Enable for copper interface Max capability advertised 100baseT full dup ...

  • RAD Data comm IPmux-11 - page 52

    Chapter 3 Operation Installation and Operation Manual 3-6 Configuration Alternatives IPmux-11 Ver. 2.00 3.4 Configuration Alternatives If required, IPmux-11 can be reconfig ured. The IPmux-11 configuration and monitoring operations are performed using any of th e following tools: • ASCII terminal connected to supervisory port • ConfiguRAD, a We ...

  • RAD Data comm IPmux-11 - page 53

    Installation and Operation Manual Chapter 3 Operation IPmux-11 Ver. 2.00 Configuration Alternatives 3-7  To enter as a user: 1. Enter user for u ser name. 2. Enter 1234 for pass word. If the password is invalid in three consecutive attempts, the system becomes inaccessible for 15 minutes.  How to use the terminal to perform a desired activity ...

  • RAD Data comm IPmux-11 - page 54

    Chapter 3 Operation Installation and Operation Manual 3-8 Configuration Alternatives IPmux-11 Ver. 2.00  Type the line number corr esponding to the desired value, and then press <Enter>  To enter a value which requires free text entry, type in the desired string and then press <Enter> . Use backspace to erase the current string. N ...

  • RAD Data comm IPmux-11 - page 55

    Installation and Operation Manual Chapter 3 Operation IPmux-11 Ver. 2.00 Configuration Alternatives 3-9 General Web Browsers Operating Procedures  To manage IPmux-11 via Web browser: 1. Open the Web browser. 2. Enter the IP address of IPmux-11 in the address field of the browser in the following format: http://’IP address’ ( ‘IP address’ ...

  • RAD Data comm IPmux-11 - page 56

    Chapter 3 Operation Installation and Operation Manual 3-10 Configuration Alternatives IPmux-11 Ver. 2.00 Overview of Menu Operations Use these menu trees as a reference ai d while performing configuration and control functions. Chapter 4 illustrates menus an d explains parameters. Host IP Manage ment User Access 1. Devi ce inf o 2. Authentication/c ...

  • RAD Data comm IPmux-11 - page 57

    Installation and Operation Manual Chapter 3 Operation IPmux-11 Ver. 2.00 Configuration Alternatives 3-11 Configuration Connection Bundle Connecti on 1. System 2. Physical layer 3. Connection 4. Bridge 1. Bundle ID 2. DS0 bundle 3. Bundle connection 1. Destination IP address 2. Next hop 3. IP TOS 4. Connection status 5. Destination bundle 6. TDM byt ...

  • RAD Data comm IPmux-11 - page 58

    Chapter 3 Operation Installation and Operation Manual 3-12 Turning IPmux-11 Off IPmux-11 Ver. 2.00 Diagnostics Ping Loopback Self Test Results 1. Pin g 2. Trace route 3. Loopback 4. Self test resu lts 1. Destinati on IP address 2. VLAN tagging 3. 5. Number of frames to send 6. Pin g sen d VLA N ID 4. VLA N prio rity 1. Loopb ack state 1. Framer tes ...

  • RAD Data comm IPmux-11 - page 59

    IPmux-11 Ver. 2.00 Configuration Sequence 4-1 Chapter 4 Configuration This chapter illustrates the IPmux-11 c onfiguration screens an d explains their parameters. Menu trees of the IPmux-11 management software are shown in Chapter 3 . 4.1 Configuration Sequence There are four basic configurat ion steps that need to be followed when depl oying any I ...

  • RAD Data comm IPmux-11 - page 60

    Chapter 4 Configuration Installation and Operation Manual 4-2 Configuring IPmux-11 for Management IPmux-11 Ver. 2.00 4.2 Configuring IPmux-11 for Management The IPmux-11 management software allows yo u to perform the following: • Defining IP parameters of the IPmux-11 host • Configuring management access • Configuring control port parameters ...

  • RAD Data comm IPmux-11 - page 61

    Installation and Operation Manual Chapter 4 Configuration IPmux-11 Ver. 2.00 Configuring IPmux-11 for Management 4-3  To enable DHCP client : 1. From the System menu, select Host IP . The Host IP menu appears (see Figure 4-2 ). 2. Fr om the Host IP menu , select DHCP , and choose Enabl e . IPmux-11 starts broadcasting requests for an IP address. ...

  • RAD Data comm IPmux-11 - page 62

    Chapter 4 Configuration Installation and Operation Manual 4-4 Configuring IPmux-11 for Management IPmux-11 Ver. 2.00  To acquire a new IP address from the DHCP server: 1. From the Host IP menu, set all host IP parameters (host IP, IP mask and default gateway) to 0.0.0. 0. 2. Enable the DHCP client. IPmux-11 reboots itself automatically and acqui ...

  • RAD Data comm IPmux-11 - page 63

    Installation and Operation Manual Chapter 4 Configuration IPmux-11 Ver. 2.00 Configuring IPmux-11 for Management 4-5  To define read, write and trap communities: 1. From the Management menu, select Authentication/community . The Authentication/Communi ty menu appears (see Figure 4-4 ). 2. From the Authentication/Com munity menu, do th e followin ...

  • RAD Data comm IPmux-11 - page 64

    Chapter 4 Configuration Installation and Operation Manual 4-6 Configuring IPmux-11 for Management IPmux-11 Ver. 2.00 It is possible to set up a local or re mote management link using the manager location and VLAN configuration. Refer to the configuration example at the end of this section.  Network-Eth1 – The network manager accesses IPmux-11 ...

  • RAD Data comm IPmux-11 - page 65

    Installation and Operation Manual Chapter 4 Configuration IPmux-11 Ver. 2.00 Configuring IPmux-11 for Management 4-7 Configuration Example Local Management Figure 4-6 illustrates how to manage a local IPmux-11 from an NMS connected via Ethernet user port 2. • VLAN tagging mode of the Ethernet user ports is configured to Double Tag • User and ma ...

  • RAD Data comm IPmux-11 - page 66

    Chapter 4 Configuration Installation and Operation Manual 4-8 Configuring IPmux-11 for Management IPmux-11 Ver. 2.00 User 2 User 2 Network Netwo rk Management Tr affic (VLA N 1) User Traffic (VLAN 100) User Traffic (VLA N 10 0) VLAN 1 VL AN 1 VLA N 10 0 VLA N 10 0 User 1 User 1 Network Manag emen t Station Local IPmux-11 Remot e IPmux-11 User Equip ...

  • RAD Data comm IPmux-11 - page 67

    Installation and Operation Manual Chapter 4 Configuration IPmux-11 Ver. 2.00 Configuring IPmux-11 for Management 4-9  Select Access , and specify the user’s access methods (ASCII ter minal, Telnet, Web browser, Telnet and Web browser, or all of them).  Select 'su' password , and enter your current superuser pa ssword.  Select N ...

  • RAD Data comm IPmux-11 - page 68

    Chapter 4 Configuration Installation and Operation Manual 4-10 Configuring IPmux-11 for Management IPmux-11 Ver. 2.00  Enable (Telnet, SNMP or Web access is enabled)  Disable (Telnet, SNMP or Web access is disabled)  Manager Only (Access is allowed only for the statio ns appearing in the manager list). Table 4-1. Management A ccess Impleme ...

  • RAD Data comm IPmux-11 - page 69

    Installation and Operation Manual Chapter 4 Configuration IPmux-11 Ver. 2.00 Configuring IPmux-11 for Operation 4-11  To select the baud rate: 1. From the System menu ( Figure 4-1 ), select Control port . The Control Port menu is displayed (se e Figure 4-11 ). 2. From the Control Port menu, select Baud rate , and configure baud rate of th e IPmu ...

  • RAD Data comm IPmux-11 - page 70

    Chapter 4 Configuration Installation and Operation Manual 4-12 Configuring IPmux-11 for Operation IPmux-11 Ver. 2.00  Channel 4  External  Fall back clock (Fall back clock type):  Internal  Adaptive  Rx clock  None  Fall back source (Fall back clock source):  Channel 1  Channel 2  Channel 3  Channel 4  Externa ...

  • RAD Data comm IPmux-11 - page 71

    Installation and Operation Manual Chapter 4 Configuration IPmux-11 Ver. 2.00 Configuring IPmux-11 for Operation 4-13 Configuring IPmux-11 at the Physical Level The TDM (E1 or T1) and Ethernet interfaces of IPmux-11 must be configured at the physical level. Configuration>Physical layer 1. TDM > 2. Eth > 3. External clock interface (Balance) ...

  • RAD Data comm IPmux-11 - page 72

    Chapter 4 Configuration Installation and Operation Manual 4-14 Configuring IPmux-11 for Operation IPmux-11 Ver. 2.00  Rx sensitivity (Maximum attenuatio n of the receive signal that can be compensated for by the interface receive path):  Short haul (-10 dB)  Long haul (-32 dB)  Trail Mode (Enables the end-to-end transfer of TDM OA M (Op ...

  • RAD Data comm IPmux-11 - page 73

    Installation and Operation Manual Chapter 4 Configuration IPmux-11 Ver. 2.00 Configuring IPmux-11 for Operation 4-15 Configuration>Physical layer>TDM (E1) Channel ID (1) Restoration time >(CCITT) Signaling mode (CAS Disabled) 1. Admin status (Enable) 2. Transmit clock source >(Adaptive) 3. Rx sensitivity (Short haul) 4. Trail mode (Term ...

  • RAD Data comm IPmux-11 - page 74

    Chapter 4 Configuration Installation and Operation Manual 4-16 Configuring IPmux-11 for Operation IPmux-11 Ver. 2.00  To configure T1 interface: • From the TDM (T1) men u, configure the following:  Admin Status:  Enable (T1 link is enabled)  Disable (T1 link is disabled)  Transmit clock source:  Adaptive (Adaptive clock regenera ...

  • RAD Data comm IPmux-11 - page 75

    Installation and Operation Manual Chapter 4 Configuration IPmux-11 Ver. 2.00 Configuring IPmux-11 for Operation 4-17  Line buildOut (CSU mo de only, Tx gain level relative to T1 output tran smit level)  0 dB (No attenuation)  7.5 dB (Attenuation of 7.5 dB relati ve to the nominal transmit level)  15 dB (Attenuation of 15 dB relati ve to ...

  • RAD Data comm IPmux-11 - page 76

    Chapter 4 Configuration Installation and Operation Manual 4-18 Configuring IPmux-11 for Operation IPmux-11 Ver. 2.00 Configuration>Physical layer>TDM (T1) Channel ID (1) 1. Admin status (Enable) 2. Transmit clock source >(Adaptive) 3. Rx sensitivity (Short haul) 4. Trail mode (Termination) 5. Line type >(ESF) 6. Line code >(B8ZS) 7. ...

  • RAD Data comm IPmux-11 - page 77

    Installation and Operation Manual Chapter 4 Configuration IPmux-11 Ver. 2.00 Configuring IPmux-11 for Operation 4-19 3. When the required Ethernet interfac e is displayed, configure the following:  Channel state:  Enable (Current Ethernet interface is enabled)  Disable (Current Ethernet interface is disabled)  Auto negotiation:  Enab ...

  • RAD Data comm IPmux-11 - page 78

    Chapter 4 Configuration Installation and Operation Manual 4-20 Configuring IPmux-11 for Operation IPmux-11 Ver. 2.00 Configuring Bund le Connections IPmux-11 supports one bundle that can includ e up to 31 E1 or up to 24 T1 timeslots. The bundle can be connected to any bundle of the TDMo IP device that operates opposite IPmux-11. Currently, TDMo IP ...

  • RAD Data comm IPmux-11 - page 79

    Installation and Operation Manual Chapter 4 Configuration IPmux-11 Ver. 2.00 Configuring IPmux-11 for Operation 4-21  Destination bundle (bundl e number in the destin ation device): 1–8063  Next hop address (Use the next hop parameter when the destination address is not in the devic e subnet. In such cases the Ethernet frame is sent to the ...

  • RAD Data comm IPmux-11 - page 80

    Chapter 4 Configuration Installation and Operation Manual 4-22 Configuring IPmux-11 for Operation IPmux-11 Ver. 2.00  Sensitive (Whether to optimize the cl ock for acc urateness or for constant delay):  Data (Accurate clock is more important than constant delay.  Delay (Constant delay is more important than accurate clock.  VLAN Tagging ...

  • RAD Data comm IPmux-11 - page 81

    Installation and Operation Manual Chapter 4 Configuration IPmux-11 Ver. 2.00 Configuring IPmux-11 for Operation 4-23 Configuration>Connection>DS0 bundle +1 +2 +3 +4 +5 +6 +7 +8 +9 +10 TS 0 1 0 0 0 0 0 0 0 0 0 TS 10 0 0 0 0 0 0 0 0 0 0 TS 20 0 0 0 0 0 0 0 0 0 0 TS 30 0 1. Change cell [0 - 1] ... (0) > Please select item <1 to 1> E - E ...

  • RAD Data comm IPmux-11 - page 82

    Chapter 4 Configuration Installation and Operation Manual 4-24 Configuring IPmux-11 for Operation IPmux-11 Ver. 2.00 Configuration>Connection>Bundle connection TDM channel ID: 1 Bundle ID: 1 1. Destination IP address ... (0.0.0.0) 2. Outbound label tagging (Enable) 3. Outbound tunnel label ... (4) 4. Outbound EXP bits ... 7 5. Inbound label t ...

  • RAD Data comm IPmux-11 - page 83

    Installation and Operation Manual Chapter 4 Configuration IPmux-11 Ver. 2.00 Configuring IPmux-11 for Operation 4-25 2. From the Bridge menu, select Aging time and defi ne a period of time in seconds from the moment when a node is disconnected fro m the network segment or becomes inactive and remo val of the node ad dress from the database. 3. Sele ...

  • RAD Data comm IPmux-11 - page 84

    Chapter 4 Configuration Installation and Operation Manual 4-26 Configuring IPmux-11 for Operation IPmux-11 Ver. 2.00  Status:  Enable (Adds the current port as a VLAN member)  Disable (Disables VLAN membership of the current port) Configuration>Bridge 1. Aging time [sec] <0-Disable>[0 - 4080] ... (304) 2. Erase MAC table 3. Bridge ...

  • RAD Data comm IPmux-11 - page 85

    Installation and Operation Manual Chapter 4 Configuration IPmux-11 Ver. 2.00 Additional Tasks 4-27 4.4 Additional Tasks Displaying the IPmux-11 Inventory The IPmux-11 inventory displays informat ion on c urrent software and hardware revisions of the unit. It als o provides the IPmux-11 interface description.  To display the IPmux-11 inventory: ? ...

  • RAD Data comm IPmux-11 - page 86

    Chapter 4 Configuration Installation and Operation Manual 4-28 Additional Tasks IPmux-11 Ver. 2.00 2. From the Date/Time menu, select Set time , and enter the current time in t he hh:mm:ss format. 3. Select Set date , and enter the current date in the yyyy:mm:dd format. Configuration>System>Date/time 1. Set time <HH:MM:SS> ... (09:12:06 ...

  • RAD Data comm IPmux-11 - page 87

    Installation and Operation Manual Chapter 4 Configuration IPmux-11 Ver. 2.00 Additional Tasks 4-29 Monitoring>Status>Diagnostics loopback Channel ID (1) Loopback state: > (Disable) > ESC-prev.menu; !-main menu; &-exit 1 Mngr/s Figure 4-30. Diagnos tics loopback Screen Displaying the TDM Phys ical Layer Information You can view the s ...

  • RAD Data comm IPmux-11 - page 88

    Chapter 4 Configuration Installation and Operation Manual 4-30 Additional Tasks IPmux-11 Ver. 2.00 Monitoring>Status>Eth Physical layer Channel > (Network-Eth1) Mode > (Full Duplex) Rate(Mbps) > (100) Status > (Connected) > F - forward ESC-prev.menu; !-main menu; &-exit 1 Mngr/s Figure 4-32. ETH Physical Layer Screen Displa ...

  • RAD Data comm IPmux-11 - page 89

    Installation and Operation Manual Chapter 4 Configuration IPmux-11 Ver. 2.00 Additional Tasks 4-31  Sequence errors – total number of sequence errors o ccurred on the bundle  Jitter buffer underflows – total number of jitter buffe r underflows occurred on the bundle  Jitter buffer overflows – to tal number of jitter buffer overflows ...

  • RAD Data comm IPmux-11 - page 90

    Chapter 4 Configuration Installation and Operation Manual 4-32 Additional Tasks IPmux-11 Ver. 2.00 2. From the File Utilities , se lect Download/Upload using TFTP . 3. From the Download/Upload using TF TP menu, configure the following:  File name (Name of the file that you int end to transfer)  Command (Operation type)  No operation  So ...

  • RAD Data comm IPmux-11 - page 91

    Installation and Operation Manual Chapter 4 Configuration IPmux-11 Ver. 2.00 Additional Tasks 4-33 Resetting IPmux-11 to the Defaults You can reset IPmux-11 t o its default setting s. The reset to the defaults does not affect the master clock setting. In additi on, you can reset local IPmux-11 without affecting its management para meters (IP addres ...

  • RAD Data comm IPmux-11 - page 92

    Chapter 4 Configuration Installation and Operation Manual 4-34 Additional Tasks IPmux-11 Ver. 2.00 ...

  • RAD Data comm IPmux-11 - page 93

    IPmux-11 Ver. 2.00 Overview 5-1 Chapter 5 Configuring IPmux-11 for a Typical Application This chapter provides detailed instr uctions for setting up a typic al application using two IPmux-11 units. 5.1 Overview Application The section provides detailed instr uctions for configuring t wo IPmux-11 unit s operating opposite each other (see Figure 5-1 ...

  • RAD Data comm IPmux-11 - page 94

    Chapter 5 Configuring IPmux -11 for a Typical Application Installation and Op eration Manual 5-2 Configuring IPmux-11 Units IPmux-11 Ver. 2.00 Table 5-1. Configuration Summary Device E1 Parameters IP Parameters Bundle Parameters Bundle Connection IPmux-11 (A) • Transmit clock source: adaptive • Line type: Framed G.704 CRC-4 enable d • CAS: di ...

  • RAD Data comm IPmux-11 - page 95

    Installation and Operation Manual Chapter 5 Co nfiguring IPmux-11 for a Typical Application IPmux-11 Ver. 2.00 Configuring IPmux-11 Units 5-3  To configure the manager list: 1. Display the Manager List menu ( Configuration > System > Management > Manager list ), and enter IP parameters fo r the network manager station:  NMS IP addres ...

  • RAD Data comm IPmux-11 - page 96

    Chapter 5 Configuring IPmux -11 for a Typical Application Installation and Op eration Manual 5-4 Configuring IPmux-11 Units IPmux-11 Ver. 2.00 Configuring Bund les  To assign timeslots to a bundle: 1. Display the Connection menu ( Configuration > Connection ), and assign a number 1 to a bundle. 2. Display the DS0 Bundle Configuratio n menu ( ...

  • RAD Data comm IPmux-11 - page 97

    Installation and Operation Manual Chapter 5 Co nfiguring IPmux-11 for a Typical Application IPmux-11 Ver. 2.00 Configuring IPmux-11 Units 5-5 Configuration>Connection>Bundle connection 1. Destination IP address ... (192.168.10.1) 2. Next hop ... (0.0.0.0) 3. IP TOS ... (0) 4. Connection status (Enable) 5. Destination bundle [1 - 496] ... (1) ...

  • RAD Data comm IPmux-11 - page 98

    Chapter 5 Configuring IPmux -11 for a Typical Application Installation and Op eration Manual 5-6 Configuring IPmux-11 Units IPmux-11 Ver. 2.00 ...

  • RAD Data comm IPmux-11 - page 99

    IPmux-11 Ver. 2.00 Monitoring Performance 6-1 Chapter 6 Troubleshooting and Diagnostics This chapter describes how to: • Monitor performance • Detect errors • Handle alarms • Troubleshoot problems • Perform diagnostic tests. 6.1 Monitoring Performance IPmux-11 provides powerful performance monitoring tools, which consist of the following ...

  • RAD Data comm IPmux-11 - page 100

    Chapter 6 Troubleshooting and Diagnostics Installation and Operation Manual 6-2 Monitoring Performance IPmux-11 Ver. 2.00  To view the E1/T1 statistics: 1. From the Monitoring menu ( Figure 6-6 ), select Statistics . The Statistics menu appears. 2. From the Statistics menu, select Physical Layer . The Physical Layer (E1) or Physical Layer (T1) s ...

  • RAD Data comm IPmux-11 - page 101

    Installation and Operation Manual Chapter 6 Troubleshooting and Diagnostics IPmux-11 Ver. 2.00 Monitoring Performance 6-3 Table 6-1. E1/T1 Statistic s Alarm Description LOS Number of seco nds with Loss of Signal . A Loss of Signal indicates that there is either no signal arriving from the adjacent E1/T1 device or no valid E1 volt age mask or no vol ...

  • RAD Data comm IPmux-11 - page 102

    Chapter 6 Troubleshooting and Diagnostics Installation and Operation Manual 6-4 Monitoring Performance IPmux-11 Ver. 2.00 Table 6-1. E1/T1 Statistic s (Cont.) RAI (Yellow) Number of seconds with Remote Alarm Indica tors . A Remote Alarm Indicator is sent by a devi ce when it enters RED state (loses sync). RAI Alarm indicates that the adjacent E 1/T ...

  • RAD Data comm IPmux-11 - page 103

    Installation and Operation Manual Chapter 6 Troubleshooting and Diagnostics IPmux-11 Ver. 2.00 Monitoring Performance 6-5 Table 6-1. E1/T1 Statistic s (Cont.) Alarm Description ES An Errored Second is a second containing one or more of the following: • CRC error • SEF (OOF) • AIS (T1 only) • If SES is active ES runs for 10 seconds and then ...

  • RAD Data comm IPmux-11 - page 104

    Chapter 6 Troubleshooting and Diagnostics Installation and Operation Manual 6-6 Monitoring Performance IPmux-11 Ver. 2.00 Monitoring>Statistics>Bridge Channel > (User1-Eth2) Frames Received Frames Transmitted Total Frames: (0) Correct Frames: (0) Total Octets: (0) Correct Octets: (0) Oversize Frames (0) Collisions: (0) Fragments: (0) Jabbe ...

  • RAD Data comm IPmux-11 - page 105

    Installation and Operation Manual Chapter 6 Troubleshooting and Diagnostics IPmux-11 Ver. 2.00 Monitoring Performance 6-7 Displaying Bundle Connection Statistics The Connection screen provides infor mation about the integrity of the TDMoIP connection, including the jitter buffer statistics. (Each bundle has it own independent jitter buffer ).  T ...

  • RAD Data comm IPmux-11 - page 106

    Chapter 6 Troubleshooting and Diagnostics Installation and Operation Manual 6-8 Monitoring Performance IPmux-11 Ver. 2.00 Table 6-2. Bundle Con nection Parameters Parameter Description Sequence Errors The number of seconds with at least one seque nce error since the last clear. Each packet transmitted by IPmux-11 holds a sequ ence number. The recei ...

  • RAD Data comm IPmux-11 - page 107

    Installation and Operation Manual Chapter 6 Troubleshooting and Diagnostics IPmux-11 Ver. 2.00 Monitoring Performance 6-9 Table 6-2. Bundle Connection Parame ters (Cont.) Parameter Description Jitter Buffer Underflows The number of seconds with at least one jitter buffer underflow event since the last clear. IPmux-11 is equipped with a “Packet De ...

  • RAD Data comm IPmux-11 - page 108

    Chapter 6 Troubleshooting and Diagnostics Installation and Operation Manual 6-10 Detecting Errors IPmux-11 Ver. 2.00 Table 6-2. Bundle Connection Parame ters (Cont.) Parameter Description Jitter Buffer Overflows The number of seconds with at least one jitter buffer overflow ev ent since the last clear. Explanation: In steady state, the jitter buffe ...

  • RAD Data comm IPmux-11 - page 109

    Installation and Operation Manual Chapter 6 Troubleshooting and Diagnostics IPmux-11 Ver. 2.00 Detecting Errors 6-11 Diagnostics 1. Ping > 2. Loopback > 3. Trace route > 4. Self Test Results > > Please select item <1 to 4> ESC-prev.menu; !-main menu; &-exit 1 Mngr/s Figure 6-4. Diagnostics Menu Diagnostics>Self Test Resu ...

  • RAD Data comm IPmux-11 - page 110

    Chapter 6 Troubleshooting and Diagnostics Installation and Operation Manual 6-12 Detecting Errors IPmux-11 Ver. 2.00 Monitoring 1. Statistics > 2. Status > 3. Event Log > > Please select item <1 to 3> ESC-prev.menu; !-main menu; &-exit 1 Mngr/s Figure 6-6. Monitoring Menu Monitoring>Event log 1. Read log file [] 2. Clear lo ...

  • RAD Data comm IPmux-11 - page 111

    Installation and Operation Manual Chapter 6 Troubleshooting and Diagnostics IPmux-11 Ver. 2.00 Detecting Errors 6-13 Table 6-3. Event List Event Description Corrective Action COLD START IPmux-11 has been powered up None CON LOCAL FAIL Ethernet frames are not received by the local IPmux-11 on the specified connection Check Eth/IP path CON REMOTE FAI ...

  • RAD Data comm IPmux-11 - page 112

    Chapter 6 Troubleshooting and Diagnostics Installation and Operation Manual 6-14 Detecting Errors IPmux-11 Ver. 2.00 Table 6-3. Event List (Co nt.) Event Description Corrective Action LINE AIS END Line AIS state detected has ended None LINE AIS START IPmux-11 has AIS (alarm indicator signal) state on its E1/T1 port Check for a fault at the PDH ne t ...

  • RAD Data comm IPmux-11 - page 113

    Installation and Operation Manual Chapter 6 Troubleshooting and Diagnostics IPmux-11 Ver. 2.00 Handling Alarms 6-15 Configuring the Bundle Statistics Collection You can set the interval for the bundle statistics collection, as we ll the statistics threshold.  To configure the bundle statistic collection: • From the Event Log menu ( Figure 6-7 ...

  • RAD Data comm IPmux-11 - page 114

    Chapter 6 Troubleshooting and Diagnostics Installation and Operation Manual 6-16 Troubleshooting IPmux-11 Ver. 2.00 6.4 Troubleshooting The following table presents the event type s as they appear on the Event Log File and lists the actions required to co rrect the event (alarm) indication. Table 6-4. IPmux-11 Troubleshooting Chart Fault Probable C ...

  • RAD Data comm IPmux-11 - page 115

    Installation and Operation Manual Chapter 6 Troubleshooting and Diagnostics IPmux-11 Ver. 2.00 Testing IPmux-11 6-17 6.5 Testing IPmux-11 Diagnostic capabilities of IPmux-11 include: • External loopbacks • Inband remote loopbacks for T 1 lines • Internal loopbacks • Pinging IP hosts • Running a trace route. Running Loopbacks Running Exter ...

  • RAD Data comm IPmux-11 - page 116

    Chapter 6 Troubleshooting and Diagnostics Installation and Operation Manual 6-18 Testing IPmux-11 IPmux-11 Ver. 2.00  To run a loopback: 1. From the Diagnostics menu ( Figure 6-4 ), select Loopback . The Loopback menu is displayed (see Figure 6-12 ). 2. From the Loopback menu, type F to select the E1/T1 link t hat you intend to test. 3. From the ...

  • RAD Data comm IPmux-11 - page 117

    Installation and Operation Manual Chapter 6 Troubleshooting and Diagnostics IPmux-11 Ver. 2.00 Testing IPmux-11 6-19 Activating T1 Inband Loopbacks T1 physical loopbacks ca n be activated by receiving a loopback activation c ode from TDM equipment connected to t he T1 port. When IPmux-11 receives a loopback activation code, it closes an external lo ...

  • RAD Data comm IPmux-11 - page 118

    Chapter 6 Troubleshooting and Diagnostics Installation and Operation Manual 6-20 Testing IPmux-11 IPmux-11 Ver. 2.00 • Define loop-up code length (Length of th e code to be sent by the TDM devic e in order to activate a loopback) • Define loop-up code (Co de to be sent by the TDM de vice in order to activate a loopback) • Define loop-down cod ...

  • RAD Data comm IPmux-11 - page 119

    Installation and Operation Manual Chapter 6 Troubleshooting and Diagnostics IPmux-11 Ver. 2.00 Testing IPmux-11 6-21 Diagnostics>Ping 1. Destination IP address ... (0.0.0.0) 2. VLAN tagging (Enable) 3. VLAN ID[1 - 4095] ... (0) 4. VLAN priority[0 - 7] ... (0) 5. Number of frames to send[1 - 4] ... (1) 6. Ping send > Please select item <1 t ...

  • RAD Data comm IPmux-11 - page 120

    Chapter 6 Troubleshooting and Diagnostics Installation and Operation Manual 6-22 Frequently Asked Questions IPmux-11 Ver. 2.00 Diagnostics>Trace route 1. Destination IP address ... (0.0.0.0) 2. VLAN tagging (Enable) 3. VLAN ID[1 - 4095] ... (1) 4. VLAN priority tag [0 - 7] ... (0) 5. Trace route send > Please select item <1 to 5> ESC-pr ...

  • RAD Data comm IPmux-11 - page 121

    Installation and Operation Manual Chapter 6 Troubleshooting and Diagnostics IPmux-11 Ver. 2.00 Frequently Asked Questions 6-23 Framed mode: In case of local failure on t he IPmux, or situation of jitter buffer underflow/overflow, a con ditioning patter n (00 to FF) will be sent towards the near-end TDM device on the timeslots related to that specif ...

  • RAD Data comm IPmux-11 - page 122

    Chapter 6 Troubleshooting and Diagnostics Installation and Operation Manual 6-24 Frequently Asked Questions IPmux-11 Ver. 2.00 A configuration example: Setting IP precedence of 101 and IP ToS of 1000 will give us the byte 10110000, which means that the IPmux IP ToS parameter should be configured to 176 decimals. UDP Destination Port The IPmux uses ...

  • RAD Data comm IPmux-11 - page 123

    Installation and Operation Manual Chapter 6 Troubleshooting and Diagnostics IPmux-11 Ver. 2.00 Technical Support 6-25 6.7 Technical Support Technical support for this product can be obtained from the local distrib utor from whom it was purchased. For further information, please contact th e RAD distributor nearest you or one of RAD's offices w ...

  • RAD Data comm IPmux-11 - page 124

    Chapter 6 Troubleshooting and Diagnostics Installation and Operation Manual 6-26 Technical Support IPmux-11 Ver. 2.00 ...

  • RAD Data comm IPmux-11 - page 125

    IPmux-11 Ver. 2.00 E1 and T1 Connector A-1 Appendix A Connector Wiring A.1 E1 and T1 Connector Balanced Connector The E1 and T1 interfaces of IP mux-11 terminate in an 8-pin RJ-45 connecto r, wired in accordance with Table A-1 . Table A-1. E1/T1 Port Co nnector Pinout Pin Designation Direction Function 1 RD (R) Input Receive data (ring) 2 RD (T) In ...

  • RAD Data comm IPmux-11 - page 126

    Appendix A Connector Wiring Installation and Operation Manual A-2 CONTROL Connector IPmux-11 Ver. 2.00 A.2 Ethernet Connectors The network and user Ethernet electrical interfaces terminate in 8-pi n RJ-45 connectors, wired in accordance with Table A-2 . Table A-2. Ethernet Connector Pinout Pin Function 1 Tx+ 2 Tx– 3 Rx+ 4 – 5 – 6 Rx– 7 – ...

  • RAD Data comm IPmux-11 - page 127

    IPmux-11 Installation and Operation Manual Appendix A Connector Wiring IPmux-11 Ver. 2.00 External Clock Connector A-3 A.4 External Clock Connector The external clock interface terminates in an 8-pin RJ-45 conne ctor. Table A-4 lists the connector wiring. Table A-4. EXT CL K Connector Pinout Pin Function 1 RxRing (clock in) 2 RxTip (clock in) 3 Ala ...

  • RAD Data comm IPmux-11 - page 128

    Appendix A Connector Wiring Installation and Operation Manual A-4 External Clock Connector IPmux-11 Ver. 2.00 ...

  • RAD Data comm IPmux-11 - page 129

    IPmux-11 Ver. 2.00 Booting IPmux-11 B-1 Appendix B Boot Sequence and Downloading Software This appendix provides a description of the IPmux- 11 boot procedure vi a an ASCII terminal for downloading software. The file system can hold two compressed copies of the IPmux-11 code. One copy is called the operating file, and the other is called the backup ...

  • RAD Data comm IPmux-11 - page 130

    Appendix B Boot Sequence and Downloading Software Installation and Operation Manual B-2 Downloading the Application and Configuration Software IPmux-11 Ver. 2.00 From the Boot Manager menu, you can: • List all files stored in the flash memory • Exchange the operating and backup files • Delete the operating file; the backup file becomes the op ...

  • RAD Data comm IPmux-11 - page 131

    Installation and Operation Manual Appendix B Boot Sequence and Downloading Software Downloading the Application and Configuration Software B-3 5. Send the software release file to IPmux -11 using the XMODEM utility of yo u terminal application. Once the downloading is completed, IPmux- 11 saves the new release as an active partition, the former act ...

  • RAD Data comm IPmux-11 - page 132

    Appendix B Boot Sequence and Downloading Software Installation and Operation Manual B-4 Downloading the Application and Configuration Software IPmux-11 Ver. 2.00 ...

  • RAD Data comm IPmux-11 - page 133

    IPmux-11 Ver. 2.00 SNMP Environment C-1 Appendix C SNMP Management This appendix provides specific in format ion for IPmux-11 management by SNMP (Simple Network Management Protocol). The SNMP management functions of IPmux- 11 are provide d by an internal SNMP agent. The SNMP management communication uses UDP (User Datagram Protocol), which is a con ...

  • RAD Data comm IPmux-11 - page 134

    Appendix C SNMP Management Installation and Operation Manual C-2 SNMP Environment IPmux-11 Ver. 2.00 Management Information Base (MIB) The MIB includes a collection of managed ob jects. A managed o bject is defined as a parameter that can be managed, such as a performance statistics value. The MIB includes the definitions of relevant mana ged o bje ...

  • RAD Data comm IPmux-11 - page 135

    Installation and Operation Manual Appendix C SNMP Management IPmux-11 Ver. 2.00 SNMP Environment C-3 MIBs Supported by the IPmux-11 SNM P Agent The interpretation of the relevant MIBs is a function of the SN MP agent of each managed entity. The general MIBs supporte d by the IPmux-11 SNMP agent are: • rfc1213.mib (except the interfaces vie w whic ...

  • RAD Data comm IPmux-11 - page 136

    Appendix C SNMP Management Installation and Operation Manual C-4 SNMP Environment IPmux-11 Ver. 2.00 SNMP Communities SNMP delimits management do mains by de fining commun itie s. Each community is identified by a name, which is an alphanumeric string of up to 255 charac ters defined by the user. The IPmux-11 SNMP agent defines strings of up to 10 ...

  • RAD Data comm IPmux-11 - page 137

    IPmux-11 Ver. 2.00 I-1 Index —A— AIS, 4-14 Alarms, 1-15, 6-15 Autonegotiation, 4-19 —B— Boot Boot manager, B-1 Bridge aging time, 4-25 configuration, 4-24 MAC table, 4-25 modes, 1-2, 1-17, 1-19, 4-25 Bundles assigning timeslots, 4-20 collecting statistics, 6- 7 configuring connections, 4-20 configuring statistics collection, 6-15 physical l ...

  • RAD Data comm IPmux-11 - page 138

    Index Installation and Operation Manual I-2 IPmux-11 Ver. 2.00 —I— Inventory, 4-27 —J— Jitter buffer, 1-12, 6-9 , 6-10 depth, 1-12 max deviation, 6-10 time sinc e, 6-10 —L— LEDs, 3-1 Loopbacks disabling, 6-18 external, 6-17 internal, 6-17 running, 6-18 T1 inband, 6-19 —M— MAC table, 4-25 Management access method, 4-9 authentication, ...

  • RAD Data comm IPmux-11 - page 139

    Installation and Operation Manual Index IPmux-11 Ver. 2.00 I-3 environment, C-1 operations, C-1 Statistics bundles, 6-7 E1, 6-1 Ethernet, 6-5 T1, 6-1 Status bundles, 4-30 Diagnostics loopback, 4-28, 6- 18 Eth physical layer, 4-29 system clock, 4-31 TDM physical layer, 4-29 Superuser, 3-6, 4-8 —T— T1 collecting statistics, 6- 1 configuring the p ...

  • RAD Data comm IPmux-11 - page 140

    Index Installation and Operation Manual I-4 IPmux-11 Ver. 2.00 ...

  • RAD Data comm IPmux-11 - page 141

    11 22 33 Front Panel 377-901-02/06 Supplement Drilling T emplate for W all Inst allation This panel is drawn to scale. T o drill the holes for a wall installation, tear this page out of the manual or print it and hold it against the wall. on letter-size paper (8.5"x1 1.0") LEDs facing up - drill at . 1 LEDs facing down - drill at . LEDs f ...

  • RAD Data comm IPmux-11 - page 142

    ...

  • RAD Data comm IPmux-11 - page 143

    24 Raoul W allenberg St., T el Av i v 69719, Israel T el: +972-3-6458181, F ax: +97 2-3-6483331, +972-3-6498250 E-mail: , W eb site: Customer Response Form RAD Data Communications would like your hel p in improving its product documentation. Please complete and return this form by mail or by fax or s end us an e-mail with your comments. Thank you f ...

  • RAD Data comm IPmux-11 - page 144

    ...

  • RAD Data comm IPmux-11 - page 145

    Error Report Type of Error(s)  Incompatibility with product or Problem(s):  Difficulty in understanding text  Regulatory in formation (Safety, Compliance, Warnings, etc.)  Difficulty in finding needed informat ion  Missing information  Illogical flow of information  Style (spelling, grammar, references, etc.)  Appearance  ...

  • RAD Data comm IPmux-11 - page 146

    ...

  • RAD Data comm IPmux-11 - page 147

    ...

  • RAD Data comm IPmux-11 - page 148

    Publication No. 352-20 0-08/06 www.rad.com INTERNATIONAL HEADQUARTER S: 24 Raoul Wallenberg Street, Tel Aviv 69719, Israel, Tel: 972-3-6458181 Fax: 972-3-6498250, 972-3-647 4436, Email: market@rad.com NORTH AMERICA HEADQUARTE RS: 900 Corporate Drive, Mahwah, N.J. 07430, Tel: (2 01) 529-1100 Toll Free: 1-800-444-7234, Fa x: (201) 529-5777, Email: ma ...

Fabricant RAD Data comm Catégorie Network Card

Les documents que nous recevons du fabricant de l'appareilRAD Data comm IPmux-11 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques RAD Data comm
- manuels d’utilisations IPmux-11
- fiches produit RAD Data comm
- dépliants
- ou étiquettes-énergie RAD Data comm IPmux-11
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation RAD Data comm IPmux-11.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation RAD Data comm IPmux-11, manuels d’entretien, brefs manuels ou manuels de l’utilisateur RAD Data comm IPmux-11. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit RAD Data comm IPmux-11.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil RAD Data comm IPmux-11, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser RAD Data comm IPmux-11 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs RAD Data comm IPmux-11.

Le manuel d’utilisation complet RAD Data comm, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel RAD Data comm IPmux-11 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières RAD Data comm IPmux-11, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lRAD Data comm IPmux-11 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil RAD Data comm IPmux-11 - qui devraient nous aider dans les premières étapes lors de l'utilisation RAD Data comm IPmux-11
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de RAD Data comm IPmux-11
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service RAD Data comm IPmux-11 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de RAD Data comm IPmux-11?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec RAD Data comm IPmux-11, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec RAD Data comm IPmux-11 il est probable qu’il a envie de partager la façon de le résoudre.