Manuel d’utilisation Conair 0.25 to 1.5 ton

44 pages 0.81 mb
Télécharger

Aller à la page of 44

Summary
  • Conair 0.25 to 1.5 ton - page 1

    P or tab le Chiller s Instant Access P ar ts and Service (800) 458-1960 (814) 437-6861 www .conairnet.com The Conair Group , Inc. One Conair Drive Pittsburgh, P A 15202 Phone: (412) 312-6000 F ax: (412)-312-6227 VL Series, 0.25 to 1.5 ton models UGH020/0301 Installation Maintenance Operation T r oubleshooting ...

  • Conair 0.25 to 1.5 ton - page 2

    It’ s a good idea to record the model and serial number(s) of your equipment and the date you recei ved it in the User Guide. Our service department uses this information, along with the manual number , to provide help for the specific equipment you installed. Please keep this User Guide and all manuals, engineering prints and parts lists togethe ...

  • Conair 0.25 to 1.5 ton - page 3

    Page: 3 UGH020/0301 VL Series P or table Chillers, 0.25 to 1.5 T ons T ABLE OF CONTENTS 1.0 GENERAL 5 1.1 Unit location 6 1.2 Efficiency 6 1.3 Safety 6 1.4 Clean air act 6 1.5 Miscellaneous 7 2.0 INST ALLA TION 9 2.1 General 10 2.2 T o and From process connections 10 2.3 Unit drain 11 2.4 Air-cooled condenser 11 2.5 Electrical connection 12 3.0 OPE ...

  • Conair 0.25 to 1.5 ton - page 4

    VL Series P or table Chillers, 0.25 to 1.5 T ons UGH020/0301 Page: 4 THIS P AGE INTENTIONALLY BLANK ...

  • Conair 0.25 to 1.5 ton - page 5

    Page: 5 UGH020/0301 VL Series P or table Chillers, 0.25 to 1.5 T ons 1.0 GENERAL 1.1 UNIT LOCA TION 1.2 EFFICIENCY 1.3 SAFETY 1.4 CLEAN AIR ACT 1.5 MISCELLANEOUS ...

  • Conair 0.25 to 1.5 ton - page 6

    Page: 6 VL Series P or table Chillers, 0.25 to 1.5 T ons UGH020/0301 1.1 UNIT LOCA TION A. The unit is designed for indoor use only . For most efficient operation, locate the chiller in a clean, dry and well ventilated environment. B. The unit has an air-cooled refrigerant condenser . For air-cooled condensers, a motor driven fan generates air flow ...

  • Conair 0.25 to 1.5 ton - page 7

    Page: 7 UGH020/0301 VL Series P or table Chillers, 0.25 to 1.5 T ons B. Please be aware that effective July 1, 1992, it is unlawful for any person in the course of maintaining, servicing, repairing, or disposing of refrigeration equipment to knowingly vent or otherwise dispose of any class 2 substance used as a refrigerant in the manner which permi ...

  • Conair 0.25 to 1.5 ton - page 8

    VL Series P or table Chillers, 0.25 to 1.5 T ons UGH020/0301 Page: 8 THIS P AGE INTENTIONALLY BLANK ...

  • Conair 0.25 to 1.5 ton - page 9

    Page: 9 UGH020/0301 VL Series P or table Chillers, 0.25 to 1.5 T ons 2.0 INST ALLA TION 2.1 GENERAL 2.2 TO AND FROM PROCESS CONNECTIONS 2.3 UNIT DRAIN 2.4 AIR COOLED CONDENSER 2.5 ELECTRICAL CONNECTION ...

  • Conair 0.25 to 1.5 ton - page 10

    2.1 GENERAL A. All process piping materials (such as hose, rigid piping, valves or filters) used in process water piping circuitry must be rated for 100°F minimum temperature and 100 PSI minimum pressure. B. All such materials must have the equivalent or larger diameter of the particular process connection that length of process water piping is co ...

  • Conair 0.25 to 1.5 ton - page 11

    Page: 11 UGH020/0301 VL Series P or table Chillers, 0.25 to 1.5 T ons 2.3 DRAIN CONNECTION: A. The unit is supplied as standard with a ProCon type pump. In some cases, it may be necessary to drain the unit. This is done by removing the pump volute plug in the pump assembly . B. Note that if chemical treatment of process fluid or additives are use, ...

  • Conair 0.25 to 1.5 ton - page 12

    Page: 12 VL Series P or table Chillers, 0.25 to 1.5 T ons UGH020/0301 2.5 ELECTRICAL CONNECTION A. NEMA 1 MODELS 1. Electrical power supply requirements for Nema 1 units (figure 2.5A) are identified on the equipment data plate. V erify that available voltage supply is the same as the unit’ s voltage requirements. W ARNING : Do not connect the uni ...

  • Conair 0.25 to 1.5 ton - page 13

    3.0 OPERA TIONS 3.1 GENERAL 3.2 ST ART UP/OPERA TIONS PROCEDURE 3.3 INSTRUMENT OPERA TION 3.4 SHUT DOWN/DISCONNECT SEQUENCE Page: 13 UGH020/0301 VL Series P or table Chillers, 0.25 to 1.5 T ons ...

  • Conair 0.25 to 1.5 ton - page 14

    Page: 14 VL Series P or table Chillers, 0.25 to 1.5 T ons UGH020/0301 3.1 GENERAL A. Failure to follow the factory required operation procedures may adversely affect the unit’ s ability to control process temperature and may create a hazardous operating condition which may result in unit damage and serious operator injury or death. B. The Operati ...

  • Conair 0.25 to 1.5 ton - page 15

    Page: 15 UGH020/0301 VL Series P or table Chillers, 0.25 to 1.5 T ons B. OPERA TIONS 1. T urn the thermostat to the highest setting. 2. Shift the illuminated toggle switch to the ‘ON’ position. The pump will begin operations. Note the reservoir level, if it drops below 3/4 full, add fluid. 3. Check the unit and process system for leaks. Repair ...

  • Conair 0.25 to 1.5 ton - page 16

    Page: 16 VL Series P or table Chillers, 0.25 to 1.5 T ons UGH020/0301 2. UP: used to increase the setpoint value, as well as the parameter when in programming. When held down for a few seconds, the change rate accelerates. 3. DOWN: used to decrease the setpoint value, as well as the parameter when in programming. When held down for a few seconds, t ...

  • Conair 0.25 to 1.5 ton - page 17

    Page: 17 UGH020/0301 VL Series P or table Chillers, 0.25 to 1.5 T ons 8. PSE: Probe SElection. Input type (for RTD or Thermocouples only). RTD models: Ni = Ni100; Pt = Pt100. T/C models: FE = T cJ; Cr = T cK; rh = T cS. 9. HC1: Heating/Cooling. Relay switch function. H = heating (humidification; reverse action); C = cooling (dehumidification; direc ...

  • Conair 0.25 to 1.5 ton - page 18

    Page: 18 VL Series P or table Chillers, 0.25 to 1.5 T ons UGH020/0301 3. Other parameters are accessed with the “UP” and “DOWN” button. With the “SET” button, the actual setting of each parameter is displayed. T o change a parameter setting, push the “SET” plus the “UP” (or “DOWN”). 4. The system will automatically return to ...

  • Conair 0.25 to 1.5 ton - page 19

    Page: 19 UGH020/0301 VL Series P or table Chillers, 0.25 to 1.5 T ons 4.0 TROUBLESHOOTING 4.1 UNIT WILL NOT ST ART 4.2 PUMP WILL NOT ST ART 4.3 COMPRESSOR WILL NOT ST ART 4.4 UNIT SHUTS DOWN ON HIGH PRESSURE SWITCH 4.5 UNITS SHUTS DOWN ON LOW PRESSURE SWITCH ...

  • Conair 0.25 to 1.5 ton - page 20

    Page: 20 VL Series P or table Chillers, 0.25 to 1.5 T ons UGH020/0301 4.1 UNIT WILL NOT ST ART A. Blow fuse at power supply - isolate open fuse and replace. Double check fuse sizes against nameplate amperage. B. Low voltage - measure incoming voltage with meter , voltage must be within 10% of nameplate voltage or warranty will be voided. 4.2 PUMP W ...

  • Conair 0.25 to 1.5 ton - page 21

    Page: 21 UGH020/0301 VL Series P or table Chillers, 0.25 to 1.5 T ons C. Restriction to refrigerant flow in refrigeration circuit. D. Poor heat transfer in evaporator tank because (1) percentage of glycol to water is too high and (2) scaled tubes in evaporator tank (chemically descale). E. Low flow through evaporator tank due to (1) process flow re ...

  • Conair 0.25 to 1.5 ton - page 22

    VL Series P or table Chillers, 0.25 to 1.5 T ons UGH020/0301 Page: 22 THIS P AGE INTENTIONALLY BLANK ...

  • Conair 0.25 to 1.5 ton - page 23

    Page: 23 UGH020/0301 VL Series P or table Chillers, 0.25 to 1.5 T ons 5.0 MAINTENANCE 5.1 W ARRANTY SERVICE PROCEDURE 5.2 PERIODIC PREVENT A TIVE MAINTENANCE 5.3 SPECIAL MAINTENANCE 5.4 PUMP REP AIR ...

  • Conair 0.25 to 1.5 ton - page 24

    Page: 24 VL Series P or table Chillers, 0.25 to 1.5 T ons UGH020/0301 5.1 W ARRANTY SERVICE PROCEDURE A. In the event of a problem with a chiller that can not be resolved by normal troubleshooting procedures, the customer is invited to consult the Conair service department for assistance. The correct model number and serial number of the chiller mu ...

  • Conair 0.25 to 1.5 ton - page 25

    Page: 25 UGH020/0301 VL Series P or table Chillers, 0.25 to 1.5 T ons I. Refrigerant sight glass: check for bubbles when compressor is operating at 100%. Check the moisture indicator for a color other than green. J. Clean unit. 5.3 SPECIAL MAINTENANCE A. Any service of the refrigeration system must be accomplished by a certified refrigeration techn ...

  • Conair 0.25 to 1.5 ton - page 26

    VL Series P or table Chillers, 0.25 to 1.5 T ons UGH020/0301 Page: 26 THIS P AGE INTENTIONALLY BLANK ...

  • Conair 0.25 to 1.5 ton - page 27

    Page: 27 UGH020/0301 VL Series P or table Chillers, 0.25 to 1.5 T ons 6.0 COMPONENTS 6.1 W A TER SYSTEM 6.2 REFRIGERA TION SYSTEM ...

  • Conair 0.25 to 1.5 ton - page 28

    Page: 28 VL Series P or table Chillers, 0.25 to 1.5 T ons UGH020/0301 6.1 W A TER SYSTEM A. MOTOR/PUMP ASSEMBL Y : the motor/pump assembly circulates chilled fluid to the process loop. The pump assembly is built of brass to maintain water quality . 6.2 REFRIGERA TION SYSTEM A. COMPRESSOR: hermetic compressors take low pressure/low temperature refri ...

  • Conair 0.25 to 1.5 ton - page 29

    Page: 29 UGH020/0301 VL Series P or table Chillers, 0.25 to 1.5 T ons 7.0 RELA TED DRA WINGS 7.1 ELECTRICAL DRA WING (TYPICAL) 7.2 CIRCUIT SCHEMA TIC ...

  • Conair 0.25 to 1.5 ton - page 30

    Page: 30 VL Series P or table Chillers, 0.25 to 1.5 T ons UGH020/0301 7.1 ELECTRICAL DRA WING (TYPICAL) M1 56 PUMP 55 6 GREEN 6 55 11 11 5 11 11 DUAL HIGH-LOW PRESSURESTAT 13 13 5 3 1 68 79 1 0 ELIWELL 902T TYPE "J" THERMOCOUPLE 7 7 8 8 91 0 9 10 BLU BLU/YEL BLU 24 VAC SECONDARY 230/1/60 PRIMARY BLK/WHT BLK/RED BLK/YEL BLK/ 5 11 1 8 6 4 2 ...

  • Conair 0.25 to 1.5 ton - page 31

    Page: 31 UGH020/0301 VL Series P or table Chillers, 0.25 to 1.5 T ons 7.2 CIRCUIT SCHEMA TIC 12 10 11 9 8 7 6 5 4 3 1 2 ITEM DESCRIPTION 1 Compressor 2 Air cooled condenser 3 Liquid receiver 4 Filter-drier 5 Refrigerant sight glass 6 Expansion valve 7 Evaporator 8 Pump 9 T o process connection 10 From process connection 11 Reservoir tank 12 Refrige ...

  • Conair 0.25 to 1.5 ton - page 32

    VL Series P or table Chillers, 0.25 to 1.5 T ons UGH020/0301 Page: 32 THIS P AGE INTENTIONALLY BLANK ...

  • Conair 0.25 to 1.5 ton - page 33

    Page: 33 UGH020/0301 VL Series P or table Chillers, 0.25 to 1.5 T ons 8.0 APPENDIX 8.1 SPECIFICA TIONS 8.2 OPERA TION BELOW 45°F 8.3 W A TER QUALITY CONTROL 8.4 INHIBITED PROPYLENE GL YCOL 8.5 CHILLER CAP ACITY AND DERA TE CHART 8.6 PRESSURE - TEMPERA TURE CHART FOR R-22 REFRIGERANT 8.7 ENGINEERING FORMULAS 8.8 SP ARE P ARTS LIST ...

  • Conair 0.25 to 1.5 ton - page 34

    Page: 34 VL Series P or table Chillers, 0.25 to 1.5 T ons UGH020/0301 8.1 SPECIFICA TIONS VL Air-cooled P or table Chillers: 0.25 to 1.5 tons SPECIFICA TION NO TES * T on capacity at 12,000 BTU/ton @ 50°F leaving water temper ature @ 115°F condensing temperature. Capacities may be ± 5% as reserved b y the compressor manufacturer . Capacity multi ...

  • Conair 0.25 to 1.5 ton - page 35

    Page: 35 UGH020/0301 VL Series P or table Chillers, 0.25 to 1.5 T ons 8.2 OPERA TION BELOW 48 ° F A. A chiller typically operates with a setpoint of 50°F or higher . However , if setpoints between 20° - 48°F are required, special precautions must be taken to prevent freezing and possible damage. Attention must be given to freeze protection, wat ...

  • Conair 0.25 to 1.5 ton - page 36

    Page: 36 VL Series P or table Chillers, 0.25 to 1.5 T ons UGH020/0301 Therefore, the water supply source must be disconnected and the connection capped. The operator must monitor the water/glycol level and manually make-up to maintain proper reservoir level. D. SAFETY ADJUSTMENTS 1. T o ensure safe and efficient operations at lower setpoints, adjus ...

  • Conair 0.25 to 1.5 ton - page 37

    Page: 37 UGH020/0301 VL Series P or table Chillers, 0.25 to 1.5 T ons 8.3 W A TER QUALITY CONTROL A. Lack of, as well as, improper water treatment can damage the chilling unit. The services of a competent water treatment specialist should be obtained and their recommendations followed. It is the equipment owner’ s responsibility to prevent damage ...

  • Conair 0.25 to 1.5 ton - page 38

    Page: 38 VL Series P or table Chillers, 0.25 to 1.5 T ons UGH020/0301 C. USE OF PLAIN GL YCOL: 1. Even through they do lower the freeze point, plain glycols are even more corrosive than water . The corrosion rate of plain ethylene glycol on iron, for example, is more than 2.5 times faster than plain water . On steel, it is 4.5 times faster . D. AUT ...

  • Conair 0.25 to 1.5 ton - page 39

    Page: 39 UGH020/0301 VL Series P or table Chillers, 0.25 to 1.5 T ons 8.5 CHILLER CAP ACITY AND DERA TE CHART 60 50 45 40 35 30 25 20 15 10 5 0 -5 * * * * * 105% 100% 90% 80% 70% 60% 50% 40% 30% 22% 15% 9% 5% OUTPUT TEMPERA TURE ° F FULL A V AILABLE % CAP ACITY NOTES: If operation of the chiller at less than 48°F is required, an inhibited propyle ...

  • Conair 0.25 to 1.5 ton - page 40

    Page: 40 VL Series P or table Chillers, 0.25 to 1.5 T ons UGH020/0301 8.6 PRESSURE-TEMPERA TURE CHART FOR R-22 REFRIGERANT SA TURA TED TEMPERA TURE 40°F 45°F 50°F 55°F 60°F 65°F 70°F 75°F 80°F 85°F 90°F 95°F 100°F FREON PRESSURE 68 76 84 93 100 112 122 132 144 156 168 182 196 THESE PRESSURE/TEMPERA TURE RELATIONSHIPS ARE IN AN A T -RES ...

  • Conair 0.25 to 1.5 ton - page 41

    Page: 41 UGH020/0301 VL Series P or table Chillers, 0.25 to 1.5 T ons 8.7 USEFUL ENGINEERING FORMULAS ...

  • Conair 0.25 to 1.5 ton - page 42

    Page: 42 VL Series P or table Chillers, 0.25 to 1.5 T ons UGH020/0301 8.8 P ARTS LIST P ART DESCRIPTION 800000 Caster - 3” swivel 810000 Caster - 3” rigid 895010 Coil - Chas 3100 1527475 Condensing unit #F3AHA101CFV -201 203-1-60 R-22 2169475 Filter drier - C-0525 2971475 Expansion valve - #EVGE-1-CP100 4345900 CONTROLLER - #EWPC 902T T ype J 4 ...

  • Conair 0.25 to 1.5 ton - page 43

    IMS0002/0296 S ER VICE I NFORMA TION A PPENDIX A-1 Conair has made the largest in vestment in customer support in the plastics industry . Our service e xperts are av ailable to help with any problem you might ha ve installing and operating your equipment. Y our Conair sales representati ve also can help analyze the nature of your problem, assuring ...

  • Conair 0.25 to 1.5 ton - page 44

    W ARRANTY I NFORMA TION IMS0003/0796 A PPENDIX A-2 E QUIPMENT G U ARANTEE P ERFORMANCE W ARRANTY W ARRANTY L IMIT A TIONS Conair guarantees the machinery and equipment on this order , for a period as defined in the quotation from date of shipment, against defects in material and workmanship under the normal use and service for which it was recommen ...

Fabricant Conair Catégorie Refrigerator

Les documents que nous recevons du fabricant de l'appareilConair 0.25 to 1.5 ton peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Conair
- manuels d’utilisations 0.25 to 1.5 ton
- fiches produit Conair
- dépliants
- ou étiquettes-énergie Conair 0.25 to 1.5 ton
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Conair 0.25 to 1.5 ton.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Conair 0.25 to 1.5 ton, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Conair 0.25 to 1.5 ton. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Conair 0.25 to 1.5 ton.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Conair 0.25 to 1.5 ton, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Conair 0.25 to 1.5 ton par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Conair 0.25 to 1.5 ton.

Le manuel d’utilisation complet Conair, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Conair 0.25 to 1.5 ton - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Conair 0.25 to 1.5 ton, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lConair 0.25 to 1.5 ton qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Conair 0.25 to 1.5 ton - qui devraient nous aider dans les premières étapes lors de l'utilisation Conair 0.25 to 1.5 ton
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Conair 0.25 to 1.5 ton
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Conair 0.25 to 1.5 ton dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Conair 0.25 to 1.5 ton?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Conair 0.25 to 1.5 ton, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Conair 0.25 to 1.5 ton il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)