Curtis 2200R - page 1
MODEL 2100R & 2200R Engine Gages Read Instructions Carefully ! ! ...
-
Curtis 2200R - page 2
Saf ety Instructions This instrument was manuf actured and tested according to the applicable technical standards . It complies with all the safety regulations as shipped from the f actory . Installation and star tup must be performed by skilled personnel. F ailure to install and operate the unit in accordance with these instructions may result in ...
-
Curtis 2200R - page 3
! ! T ABLE OF CONTENTS P age 1. Saf ety Instructions 2 2. Model Encodement 3 3. T echnical Specifications 3.1 Electrical 5 3.2 Mechanical 8 3.3 Environmental 9 4. Installation 11 5. T roubleshooting 14 6. Maintenance 15 ...
-
Curtis 2200R - page 4
3 2. MODEL ENCODEMENT (f or 2100R/2200R series) 2111RXX-YYYY ZZ Model Numbers 2111 T emperature 2112 Fuel 2113 Pressure 2114 V oltage 2211 T emperature/Hour 2212 Fuel/Hour 2213 Pressure/Hour 2214 V oltage/Hour ! ...
-
Curtis 2200R - page 5
4 R = case (round) XX = v oltage (DC v oltages only) YYYY = sequential number code describes gage’ s f actor y programming ZZ = ar twork code (OO = Cur tis) ! ...
-
Curtis 2200R - page 6
5 3. TECHNICAL SPECIFICA TIONS 3.1 Electrical Operating V oltage Model Series 2100R and 2200R are availab le in either 12VDC or 24VDC (negative g round systems only) Operating V oltages (Models 2111R, 2112R, 2113R and 2211R, 2212R, 2213R) Model Minimum Nominal Maximum 12V 9.0 12.0 16.0 24V 18.0 24.0 32.0 (Models 2114R and 2214R) Model Minimum Nomin ...
-
Curtis 2200R - page 7
Operating Current T otal system current is a function of the voltage, sender type, displa y mode, and the gage’ s factory programming. T ypical operating currents (not including the current to drive the sender) v ar y from 16-55 mA, f or 12V models , depending on model number . For 24V models, typical operating currents (not including the current ...
-
Curtis 2200R - page 8
Output signal trigger point (lower) First LED Second LED Output signal trigger point (upper) Ninth LED T enth LED Output signal format—(upper and lower independently set) 0-5 V 5-0 V* LED flashing mode (lower) No flashing First LED flashes alone First LED or second flashes alone Both first & second flash out of phase* LED flashing mode (upper ...
-
Curtis 2200R - page 9
Damping and Hysteresis Tr ansducer po wer modulation (XPM) Used to reduce current in sender circuit Output signal f ormat Outputs are capable of sinking or sourcing up to 1mA, maximum (50 µ A maximum is standard) The 5V -0 output signal format is fully compatible with the Cur tis Model 1178 relay module. 3.2 Mechanical Te r minals (Spade) 6 ANSI/N ...
-
Curtis 2200R - page 10
Bezel Material Aluminum, blac k anodized Hardware U clamp (1) (Individually box ed 4 mm lock washers (2) un it s ) F emale 1/4 inch fast-on connectors (up to 6) 4 mm knurled thumbnuts (2) Hardware U clamp (1) (OEM bulk pac ked) 4 mm lock w ashers (2) 4 mm hex n uts (2) 3.3 En vironmental T emperature Operating -40C to +85C Storage -50C to +90C Shoc ...
-
Curtis 2200R - page 11
Vibration Meets SAE J 1378 March 83. Double amplitude of 1.53 mm with frequency sw eep from 10-80-10 Hz (20 g max) at intervals of 1 minute. Humidity 95% RH (non-condensing) at +38C Wa ter/dust immunity F ace IP63 Rear IP50 Salt spra y (fog) ASTM B 117-73 as per SAE J1810, section 4.7.1.2 10 ! ...
-
Curtis 2200R - page 12
4. INST ALLA TION Te r m inal Assignment f or Models 2111R, 2112R, 2113R 1 Sender in 2B attery + 3G round 4 Sender low (optional: for use with two wire senders) 5 Output signal (upper) 6 Output signal (lower) ! 11 ...
-
Curtis 2200R - page 13
Te r minal Assignment f or Model 2114R 1 Not Connected ** 2B attery + 3G round 4 Not Connected** 5 Output signal (upper) 6 Output signal (lower) Te r minal Assignments f or Models 2211R, 2212R, 2213R 1 Sender in 2B attery + 3G round 4 Hourmeter enable* 5 Output signal (upper) 6 Output signal (lower) ! 12 ...
-
Curtis 2200R - page 14
Te r minal Assignments f or Model 2214R 1 Not connected*** 2B attery + 3G round 4 Hourmeter enable*** 5 Output signal (upper) 6 Output signal (lower) * Options terminal can be factory programmed to function as hourmeter reset or sender low (for use with two wire senders) **Options terminal-can be factory programmed to measure a separate v ariable v ...
-
Curtis 2200R - page 15
5. TR OUBLESHOO TING The follo wing checklist should help y ou to trou- b leshoot an y problems with the instrument. T urning the instrument off and then on again after about 10 seconds may solv e the prob lem in the simplest cases. Make sure to observe the saf ety instructions in Section 1. Pr ob lem P ossib le Cause No display V oltage on Battery ...
-
Curtis 2200R - page 16
6. MAINTENANCE Cur tis 2100R & 2200R Series Engine Gages are not serviceable in the field. Units returned to the f actory within the warranty period will be replaced without charge. 16 ! ...
-
Curtis 2200R - page 17
Guarantee - These Curtis Instr uments’ products are guaran- teed against defects in w orkmanship and material for a period of three years , or as defined in the individual product literature, from date of shipment from our factory , when applied in a prop- er application within specified ratings. This guarantee is limited to repair or replacement ...
-
Curtis 2200R - page 18
CURTIS INSTRUMENTS, INC. 200 Kisco A venue, Mt. Kisco, NY 10549 T el. (914) 666-2971 • FAX (914) 666-2188 53018 REV A 10/97 ...
Hai una domanda su Curtis 2200R?
Utilizza il modulo sottostante
Se non hai risolto il problema con Curtis 2200R con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Curtis 2200R è probabile che voglia condividere il modo di risolverlo.