Manuale per l’uso APC AP9830

31 pagine 0.61 mb
Scarica

Vai alla pagina of 31

Summary
  • APC AP9830 - page 1

    Remote Power -Off Devic e AP9830 Ins talla tion an d Quick Star t ...

  • APC AP9830 - page 2

    Remote Po wer-Off Devic e — Installa tion and Q uick Start Conte nts Features and Requirements 1 Feature s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Hardwa re Re quire ments . . . . . . . . . . . . . . . . . . . . 2 Safety Inf ormation 3 Avoid H azardo us Confi guration s . . . . . . . . . . . . . . 3 Exam ple of th e pote ...

  • APC AP9830 - page 3

    ii Remote Po wer-Off Devic e — Installation a nd Quick Start Contents Set up t he Rem ote P ower-Of f Devic e . . . . . . . . . . 14 Remot e switch: r equirement s and pin as signment 16 Pin locati ons for the keystone j ack 16 Pin locati ons for the RJ -11 conne ctor 16 Connect the swit ch cable to the keystone ja ck 17 Placemen t of accessor ie ...

  • APC AP9830 - page 4

    1 Featur es and Re quir ements Featur es The APC ® Remote Pow er-Off Device (RPO), AP9830, enables you to tu rn off the output pow er of an APC uninterruptible pow er supply (UPS) imm ediately by a remote swit ch. For exam ple: • If the UPS itself is n ot readily accessible, place the RPO in a convenien t location. • T o turn off the output po ...

  • APC AP9830 - page 5

    2 Remote Po wer-Of f Devic e — Installation a nd Quick St art H a rdw a re R e q u i rem e n t s The Remote Power- Off Device requires the f ollowi ng: • A Sm art-UPS ® or Matrix-UPS ™ . • A sw itch (SEL V or Class 2 circuit). • A cable to connect the rem ote sw itch to the R emote Power-Off Device. Note A Symme t ra ™ UPS has a built- ...

  • APC AP9830 - page 6

    3 Safety Information Avoid Hazar dous Configurations Example of the potentia l hazard 1. An adm inis trator uses th e remote sw i tch conn ected to the Remote Pow er-Off Device to turn off the output pow er from a UPS, but the UPS continu es to receive utilit y pow e r . 2. From an int erface of an A PC accessory device, a us er issues a com man d ...

  • APC AP9830 - page 7

    4 Remote Po wer-Of f Devic e — Installation a nd Quick St art Eliminate t he Hazard Use a n Emergency Power Off system Matrix-UPS m odels and man y S mart- UPS models have an integrated EPO system th at allow s connected equipmen t to be deenergized immediately f rom a rem ote location with out the UPS switch ing to battery operation. War n in g ...

  • APC AP9830 - page 8

    Remote Power-Off Device — Installation a nd Quick St art 5 Safe ty Inf orma tio n: E limi nat e t he H azar d Block a ccess to acces sory devic es The Remote Power-Off Device can provide a usef ul alternativ e to the integrated EPO interface of a UPS in any of th e followin g situ ations: • Y our system configu ration requires either of th e fo ...

  • APC AP9830 - page 9

    6 Remote Po wer-Of f Devic e — Installation a nd Quick St art Contact Closur e Setup with Multiple UPSs T o elimin ate t he ne ed fo r multip le conta ct cl osu res a t the remo te s w itch , do one of th e foll owing: • Use an applied voltage sw itch. • Use a cascading setup. War n in g T o connect multipl e UPSs to a system that uses contac ...

  • APC AP9830 - page 10

    7 V erify C ontents of the Shipment Unpack and Inspec t the RPO Pa ckage Please r ecycle Receiving inspecti on Inspect the package and conten ts for shipping damag e, and make su re that all parts w ere sent. Report any damage imm ediately to the sh ipping agent, and report mis sing contents, damage, or other problems im m ediately to APC or your A ...

  • APC AP9830 - page 11

    8 Remote Po wer-Of f Devic e — Installation a nd Quick St art Verify Contents o f the Ship ment: Unpack and Inspect the RPO P ackage • Remote Pow er-Off Device • Keystone jack (750-0023) • A strip of hook-an d-loop fastener (not sh own here) for optional mount ing of th e Rem ote Power-Off Dev ice. ...

  • APC AP9830 - page 12

    9 Components of the RPO Side Views View fr om the server sid e of the RPO View fr om the UPS side of th e RPO  DB9 female port to connect to server or accessories  RJ-1 1 port: RPO/Cascade In  RJ-1 1 port: Cascade Out     Configu ration DIP sw itches  DB9 Male Port to connect to UPS For DIP switch set tings , see “ Conf ig ...

  • APC AP9830 - page 13

    10 Remote Power- Off Device — Insta llation and Q uick Start To p V i e w  Pow e r-O ff /T e st L ED  Labels that identif y component s on the sides of the RPO    ...

  • APC AP9830 - page 14

    11 Configur ation and Setup Overvi ew T o configure and set up th e Rem ote Power-Off Dev ice: 1. C onfig ure the RPO to oper ate in T est ( Disab led ) po w er - off mode by settin g DIP sw itch #3 to the up position. 2. Connect the RPO. 3. T est the RPO w hile leavin g DIP sw itch #3 in the u p position. 4. Configu re the RPO to operate in the En ...

  • APC AP9830 - page 15

    12 Remote Power- Off Device — Insta llation and Q uick Start Config ur e the R emote Power -Off Device Ty p e s o f r e m o t e switches supported The RPO supports two ty pes of remote sw it ches: • A contact closure sw itch toggles betw een an open and closed circuit. • A voltage in put sw itch applies an d removes a voltag e signal. Set the ...

  • APC AP9830 - page 16

    Remote Power-Off Device — Installation a nd Quick St art 13 Configura tion and Setup: Confi gure the Remote Po wer -Off Device Power -off m ode: DIP switch #3. In either power-off mode, the Rem ote Power-Off Dev ice LED illum in ates wh en the device is connected and config ured properly and the rem ote swit ch is being asserted. DIP Switch #4. D ...

  • APC AP9830 - page 17

    14 Remote Power- Off Device — Insta llation and Q uick Start Set up t he Remote Power-Off De vice Connect s ingle and multi ple RPOs Y ou can connect one R em ote Power-O ff Device to one rem ote swit ch to control one UPS, or you can connect m u ltiple Remote Pow er-Off Devices to one rem ote sw itch to control mult iple UPSs sim ultaneous ly . ...

  • APC AP9830 - page 18

    Remote Power-Off Device — Installation a nd Quick St art 15 Configura tion an d Setup: Set u p the Remote Po wer -Off Device Note In the follow ing set-u p diagram, note th at the RJ-1 1 cable connects to the m iddle port, labeled RPO / Cascade In .  APC U PS  Keystone jack  W iring to remote sw itch  Server  Cable provided with UP ...

  • APC AP9830 - page 19

    16 Remote Power- Off Device — Insta llation and Q uick Start Configu ration a nd Setup: Set up the Remote P ower-Off Device Remote s witch: re qu i re m e n ts and pin assign ment Pin locations for the keystone jack Pin locations for the RJ -11 connect or T ype Requirements RPO/Cascade In Pin Assignment Contact Closure • Saf ety Ex tra Low V ol ...

  • APC AP9830 - page 20

    Remote Power-Off Device — Installation a nd Quick St art 17 Configura tion an d Setup: Set u p the Remote Po wer -Off Device Connect th e switch cab le to the keystone jack 1. Strip the cable j acket (the outer ins ulation of th e cable) to expose 1 inch (25.4 mm ) of the insu lated w ires (unstripped 26 – 22 A WG required). 2. Cut one of the t ...

  • APC AP9830 - page 21

    18 Remote Power- Off Device — Insta llation and Q uick Start Configu ration a nd Setup: Set up the Remote P ower-Off Device 5. Press each w ire in to its s lot on the clear plastic cap. Then inspect the cap to ensure that each w ire is in the correct slot and that the end of each w i re touches the back of th e slot. 6. Press the plastic cap, wit ...

  • APC AP9830 - page 22

    Remote Power-Off Device — Installation a nd Quick St art 19 Configura tion an d Setup: Set u p the Remote Po wer -Off Device 7. Using slip- joint pliers, terminat e the w ires by pressing the plastic cap and keys tone jack together un til the cap snaps into place. 8. Inspect the jack to ensu re that th e cap is securely snapped into place and tha ...

  • APC AP9830 - page 23

    20 Remote Power- Off Device — Insta llation and Q uick Start How to T urn Off the Output of Multiple UPSs T o set up more than one APC UPS to turn off from on e remote swit ch, y ou mu st have one Remote Pow er-Off Device for each UPS. Y ou can s et up rem ote turnoff of m ultiple UPS output s in either a cascading (serial) config uration or (for ...

  • APC AP9830 - page 24

    Remote Power-Off Device — Installation a nd Quick St art 21 Configura tion and Setup: How to Turn Off th e Output of Mult iple UPSs Matrix-UPS ® in a cascad ing configuration Y ou can in clude only one APC Matrix-U PS in a cascading configuration , and you m u st place it at the end of the series of UPSs (UPS n in the exam ple setup). Connect mu ...

  • APC AP9830 - page 25

    22 Pr oduct Information Selecting and Or dering Components Remote switch specifi catio ns Cabl e re qu i re m e n ts Y ou can u se the tw o RJ-11 cables that cam e w ith the Rem ote Power-Off Device or use ex isting building cables. The cable that connects th e Rem ote Power-Off Device to the rem ote swit ch m ust m eet these requirem ents: • It ...

  • APC AP9830 - page 26

    Remote Power-Off Device — Installation a nd Quick St art 23 Pr oduct Spe cificatio ns Physical Dimensions (H × W × D) Unit Shippi ng 2.54 × 9. 53 × 6.0 5 cm (1.0 0 × 3.75× 2.3 8 in) 7.26 × 24 .13 × 16 .51 cm (2.86 × 9.5 0 × 6.50 in) W eight Unit Shippi ng 0.23 kg (0.5 0 lb) 0.36 kg (0.8 0 lb) Distance (cable length) between th e remote ...

  • APC AP9830 - page 27

    24 Remote Power- Off Device — Insta llation and Q uick Start W arranty and Se rvice Limited warranty APC w arrants the Rem ote Pow er-Off Device to be free from defects in m aterials and w orkm ansh ip for a period of tw o y ears from the date of purchas e. Its obligation under thi s w arranty is limited to repairing or replacing, at its ow n s o ...

  • APC AP9830 - page 28

    Remote Power-Off Device — Installation a nd Quick St art 25 Product In formation: Wa r rant y and Service warranty expired, y ou w ill be charged for repair o r replacement. 4. Pack the unit carefu lly . The warrant y does not cover damage su stained in tran sit. Enclose a letter w ith y our name, address, RMA num ber and dayt ime phone num ber; ...

  • APC AP9830 - page 29

    26 Remote Power- Off Device — Insta llation and Q uick Start Life-Support Policy General poli cy Am erican Power Con version ( APC ) does not recomm end the use of any of its products in th e follow ing s ituations: • In life-su pport applications wh ere failure or malf unction of t h e APC product can be reasonably expected to cause failure of ...

  • APC AP9830 - page 30

    Radio Fr equency Interfer ence This product contains no clocks or oscillators and therefore does not cause interference. ...

  • APC AP9830 - page 31

    *990-0197A* APC W orldwide Customer Support Cust omer supp ort for this or an y other APC produ ct is av ailable at no char ge in a ny of the following ways: • V i sit the APC W eb site to access documen ts in the APC Knowledge Bas e and to subm it custom er supp ort requ ests. – www .apc.com (Corporate Headqu arters) Connect to localized APC W ...

Fabbricante APC Categoria Remote Starter

I documenti che otteniamo dal fabbricante del dispositivoAPC AP9830 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici APC
- manuali per l’uso AP9830
- schede prodotto APC
- opuscoli
- o etichette energetiche APC AP9830
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso APC AP9830.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione APC AP9830, manuali di manutenzione, brevi manuali o manuali utente APC AP9830. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto APC AP9830.

Manuali per l’uso simili

Manuale completo del dispositivo APC AP9830, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare APC AP9830 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti APC AP9830.

Il manuale per l’uso completo APC, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale APC AP9830 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice APC AP9830, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per APC AP9830 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo APC AP9830 - che ci dovrebbe aiutare nei primi passi durante l'uso APC AP9830
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del APC AP9830
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio APC AP9830 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su APC AP9830?

Utilizza il modulo sottostante

Se non hai risolto il problema con APC AP9830 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con APC AP9830 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)