    Agilent 3.125 Gb/s Serial BERT N5980A User Guide ...

  • Agilent Technologies N5980A - page 2

    Notices © Agilent Technologies, Inc. 2006 No part of this man ual may be reprodu ced in any form or by any means (including electronic storage and retrieval or translation into a foreign language) without prior a greement and written consent from Agilent Technologies, Inc. as governed by United States and international copyright laws. Manual Part ...

  • Agilent Technologies N5980A - page 3

    Safety Summary General Safety Precautions The following general safety precautions m ust be observed du ring all phases of operation of this instrument. Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety standards of de sign, manuf a cture, and in tended use of the instrument. Agilent Technol ...

  • Agilent Technologies N5980A - page 4

    Safety Symbols on Instruments General Recycling Mark for plastic parts used in the product. Indicates warning or caution. If you see this symbol on a product, you must refer to the manuals for specific Warning or Caution information to avoid personal injury or damage to the product. Notice for European Community: This product complies with the rele ...

  • Agilent Technologies N5980A - page 5

    Contents Contents 1 Introduction 7 2 Getting Started 8 Inspect Shipment 8 Connect the Instrument 9 Front Panel 9 Rear Panel 10 Install User Software for N5980A 11 To Install the User Software for N5980A 12 To Access N5980A 14 3 Operating N5980A with the User Interface 16 Introduction 16 Running the BER Test 17 Setting the Instrum ent Parameters 18 ...

  • Agilent Technologies N5980A - page 6

    Contents Error 25 Sync Loss 25 Setup and Advanced Tab 26 Setup 26 Advanced 27 BER and Advanced BER Tab 28 BER 28 Advanced BER 29 5 Programming Reference 30 Introduction 30 Common Command Summary 30 Agilent N5980A Command Summary 30 SCPI Instrument Command L ist- Reference 31 Common Commands 31 All Channels 33 SMA Output (Electrical Generator) 34 SF ...

  • Agilent Technologies N5980A - page 7

    Introduction 1 Introduction This chapter introduces you to the Serial BERT Us er Guide, and it provides information on the variou s chapters and topics covered. 1 Getting Started  Inspect Shipment  Connect the Instrument  Install User Software for N5980A 2 Operating N5980A with the User Interface  Introduction  Running the BER Test ? ...

  • Agilent Technologies N5980A - page 8

    Getting Started 2 Getting Started Inspect Shipment Before you get started with the Serial BERT check if the shipment package contains the followi ng standard deliverables: Agilent N5980A 3.125 GB/s Serial BERT Local Power Cord If the content is incomplete, if there is mechanical damage, or if the instrument does not work within its specifications, ...

  • Agilent Technologies N5980A - page 9

    Getting Started Connect the Instrument In order to connect the Serial BERT let’s have a look at the Fr ont and the Rear Panels: Front Panel The Front Panel has LEDs, Data In/O ut ports, and an SFP connector. Figure 1 Front Panel SFP The Small Form Factor Pl uggable interface (SFP) is an industry standard daughter card used in ne tworking devices. ...

  • Agilent Technologies N5980A - page 10

    Getting Started LED LEDs Function Power LED Indicates power-on USB Active Indicates that the instrument is c urrently being used/controlled by the user softw are Signal Detect Indicates the status of the Sign al Detect line when the inserted SFP module supports a Signal Detect Control li ne. Usually th is pin indica tes wh ether the optical input p ...

  • Agilent Technologies N5980A - page 11

    Getting Started Figure 3 Serial BERT setup diagram Install User Software for N5980A The requirements for software installation:  Either Windows 2000 Service Pack 4, or Windows XP Service Pack 2  Microsoft .NET Framework 2.0 is automatically downloaded from the Microsoft downl oad center du ring installation. A lternatively dotnetfx.exe may be ...

  • Agilent Technologies N5980A - page 12

    Getting Started To Install the User Software for N5980A 1 Insert the CD in the PC’s CD Drive. 2 Double-click Displays the Welcome screen. 3 The Installer guides you through th e installation process. 12 N5980A User Guide ...

  • Agilent Technologies N5980A - page 13

    Getting Started Select the folder in which N5980A will be saved. N5980A User Guide 13 ...

  • Agilent Technologies N5980A - page 14

    Getting Started After the installation is completed, click Finish to close the installer. To Access N5980A To launch N5980A, go to Pr ogram File and click on: If there is a N5980A connected to the PC via USB, and the User Software is installed, then the following screen appears: NOTE Typical Hardware Initia lization duration is between 3 to 5 minut ...

  • Agilent Technologies N5980A - page 15

    Getting Started Upon completion of Hardware Initialization, the Us er Interface starts and the following window appears. Demo Offline In Demo Offline mode N5980A need n ot be connected to the PC. The connection dialog looks like the screen below. Click Demo (Offline) to start the offline version of the GUI. NOTE Before disconnecting the USB cable, ...

  • Agilent Technologies N5980A - page 16

    Operating N5980A with the User Interface 3 Operating N5980A with the User Interface Introduction The graphical user interface runs on the PC, an d the screen is divided into tw o areas; one for se tting parameters, and the other for viewing results. The Setting Parameters area of the screen has options for setting parameters like Data Rate, Data Pa ...

  • Agilent Technologies N5980A - page 17

    Operating N5980A with the User Interface Running the BER Test The User Software supports a quick pass/fail measurement, which is generally used for testing the DUT in manufacturing. This measurement allows you to count th e number of bit errors during a user specified gating time. The result of the measurement is displayed as Gating Errors , Gating ...

  • Agilent Technologies N5980A - page 18

    Operating N5980A with the User Interface Setting the Instrument Parameters N5980A has two (SFP and SMA) integrated Patt ern Generators, which can be adjusted to different parameters, for example, different patterns or different error insertion rates. The N5980A Error Detector has two (SFP and SMA) different physical input ports, while only on e inp ...

  • Agilent Technologies N5980A - page 19

    Operating N5980A with the User Interface Advanced To view the Advanced page, click on t he File menu and enable the Advanced Mode : The Advanced page has the following settings: In this page you can set SFP and SMA Data Patterns, Error Insertion Rate, and also select Clock Trigger Output for the Generator. It also gives the option for setting the G ...

  • Agilent Technologies N5980A - page 20

    Operating N5980A with the User Interface Viewing the Results There are two options for viewing the results, BER and Advanced BER, as shown below. BER displays Gating BER and the Elapsed Gating Time . The Advanced BER page can be opened on ly when Advanced Mode is enabled. See below: In this page you can see the Gating Errors , Actual Errors , and t ...

  • Agilent Technologies N5980A - page 21

    Reference for the User Interface 4 Reference for the User Interface This section explains the measur ed parameters, and the display options that are specific to thes e measurements . Ad ditionally, some information is provided to explain the theoretical background to these measurements. When N5980A is launched the fo llowing screen is displayed: Fi ...

  • Agilent Technologies N5980A - page 22

    Reference for the User Interface Store Setting As This is used to store/recall any se tting with a user selected filename. The user selects a specific location, and file name to save the settin gs. Recall Setting This recalls the saved settings. Factory Default Setting Restores the factory default settings, and is useful when the user has problems ...

  • Agilent Technologies N5980A - page 23

    Reference for the User Interface Connect The Connect… option shows the Conn ection Dialog box. NOTE If there are no instruments connected to the PC, the n Connect button will be disabled. If an instrument is conne cted, the user can connect to that instrument. In the Available Devices , the list of connected device will appear, and the Connect bu ...

  • Agilent Technologies N5980A - page 24

    Reference for the User Interface Info This option provides the following information. Help Menu The Help Menu has the following information. About gives you the Software details. Error Indicators The GUI screen contains the Error Indicator: There are two indicators and a BER bar, see the screen ab ove. These indicators inform you ab out the followi ...

  • Agilent Technologies N5980A - page 25

    Reference for the User Interface BER Bar The BER bar displays th e BER calculated during a period of 200 ms. Error This indicator turns red when errors are detected.  Stable errors are caused by th e error add function: i t turns SFP/SMA Error Insertion Rate off.  Variable and high errors may b e caused by faulty connectors/cables . BERT conn ...

  • Agilent Technologies N5980A - page 26

    Reference for the User Interface Setup and Advanced Tab Setup General Data Rate: There are different data rates in th e drop down list. These rates are common to the Gen erator, and the Error Detector. The following screen lists the available Data Rates. Generator Data Pattern: There are different patterns availabl e, for example, PRBS patter ns, C ...

  • Agilent Technologies N5980A - page 27

    Reference for the User Interface Error Detector Data Pattern: The Error Detector (ED) has a bu ilt in CDR for automatic clock recovery, and phase alignment. Th e E D also performs automatic polarity correction when required . Additionally it can detect the incoming PRBS. The input for the Da ta Pattern has two options, SMA [Electrical], and SFP [Op ...

  • Agilent Technologies N5980A - page 28

    Reference for the User Interface On the advanced page the SFP and th e SMA Data pattern can be adjusted independently. NOTE SFP Error Insertion Rate: This drop down list gives a set of Error Insertion Rates that can be inserted for the SFP output. SMA Error Insertion Rate: This drop down list gives a set of Error Insertion Rates that can be inserte ...

  • Agilent Technologies N5980A - page 29

    Reference for the User Interface The screenshot below shows the Gating BER Bar. Elapsed Gating Time This bar shows the gating time while the test runs. Before the test begins this bar is empty as shown bel ow: And after the gating time is complete this bar appear s as shown below: Advanced BER This page contains Gating Error, Ac tual Error, Error D ...

  • Agilent Technologies N5980A - page 30

    Programming Reference 5 Programming Reference Introduction The SCPI commands represent the instrument’s advanced anal ysis, and pattern generation features th at can be controlled from within the remote programs. Programming can only be done using ra w Windows Sockets. The remote programming language is clos e to SCPI, but it’s without a full f ...

  • Agilent Technologies N5980A - page 31

    Programming Reference :SOUR1:VOLT :SOUR1:VOLT? :SOUR2:PATT :SOUR2:PATT? :SOUR2:PATT:EADD :SOUR2:PATT:EADD:RATE :SOUR2:PATT:EADD:RATE? :SOUR3:PATT? :SOUR3:PATT :SENS1:SYNC:TYPE :SENS1:SYNC:TYPE? :SENS1:PATT? :SENS1:GATE:PER :SENS1:GATE:PER? :SENS1:FETC:ECO? :SENS1:FETC:ECO:DELT? :SENS1:FETC:ERAT? :SENS1:FETC:ERAT:DELT? :SENS1:INP :SENS1:INP? :SENS1: ...

  • Agilent Technologies N5980A - page 32

    Programming Reference Read error queue :SYST:ERR? Syntax :SYST:ERR? Description Reads one error from the instruments error queue. Load factory default setting *RST Syntax *RST Description Discards the current instru ment setting, and loads the reset/default setting. Operation complete *OPC? Syntax *OPC? Description Returns 1 when all pending comman ...

  • Agilent Technologies N5980A - page 33

    Programming Reference Store current setting :MMEM:STOR:STAT “filename” Syntax :MMEM:STOR:STAT “filename” Description Stores the current setting into the specified file. If a file with the same name already exist s, then this file will be overwritten. Recall setting :MMEM:LOAD:STAT “filename” Syntax :MMEM:LOAD:STAT “filename” Descrip ...

  • Agilent Technologies N5980A - page 34

    Programming Reference SMA Output (Electrical Generator) The SMA output is accessed via the r oot node :SOUR1 Pattern :SOUR1:PATT Syntax :SOUR1:PATT? :SOUR1:PATT PRBS7 | PRBS1 5 | PRBS23 | PRBS 31 | CLK2 | CLK4 | CLK8 | CLK1 0 | CLK16 | CLK20 | K28_5 Description Either sets or gets the pattern of the SMA output. Available Patterns Name Parameter PRB ...

  • Agilent Technologies N5980A - page 35

    Programming Reference Error Insertion The error insertion is capable to enforce a given error ratio, and to add single errors into the data stre am. Both ar e available in parallel. Insertion Rate :SOUR1:PATT:EADD: RATE Syntax :SOUR1:PATT:EA DD:RATE? :SOUR1:PATT:EA DD:RATE NR3 Description Either sets or gets the error insertion rate. Only t he list ...

  • Agilent Technologies N5980A - page 36

    Programming Reference SFP Output (Optical Generator) The SFP output is accessed via the root node :SOU R2 Pattern :SOUR2:PATT Syntax :SOUR2:PATT? :SOUR2:PATT PRBS7 | PRBS1 5 | PRBS23 | PRBS 31 | CLK2 | CLK4 | CLK8 | CLK1 0 | CLK16 | CLK20 | K28_5 Description Either sets or gets the pattern of the SFP output. Available Patterns Name Parameter PRBS 2 ...

  • Agilent Technologies N5980A - page 37

    Programming Reference Error Insertion The error insertion is capable to enforce a given error ratio, and to add single errors into the data stre am. Both ar e available in parallel. Insertion Rate :SOUR2:PATT:EADD: RATE Syntax :SOUR2:PATT:EA DD:RATE? :SOUR2:PATT:EA DD:RATE NR3 Description Either sets or gets the error insertion rate. Only t he list ...

  • Agilent Technologies N5980A - page 38

    Programming Reference Trigger Output The trigger output is accessible via the root node :SOUR3 Pattern :SOUR3:PATT Syntax :SOUR3:PATT? :SOUR3:PATT CLK2 | CLK4 | CL K8 | CLK10 | CLK 16 | CLK20 Description Either sets or gets the pattern of the trigger output. Available Patterns Name Parameter Clock / 2 CLK2 Clock / 4 CLK4 Clock / 8 CLK8 Clock / 10 C ...

  • Agilent Technologies N5980A - page 39

    Programming Reference Synchronization mode :SENS1:SYNC:TYPE Syntax :SENS1:SYNC:TYPE AUTO|SFP|SMA|PRBS7|PRBS15|PEBS23|PRBS31 :SENS1:SYNC:TYPE? Description Either sets or gets the sync hronization type. The synchronization t ype defines whic h patterns will be used to synchronize when a synchronizatio n loss is detect ed by the Error Detector. Availa ...

  • Agilent Technologies N5980A - page 40

    Programming Reference Gating Time :SENS1:GATE:PER Syntax :SENS1:GATE:PE R? :SENS1:GATE:PE R integer Description Either gets or sets the durati on of the gating interval. The allowed range for t he gating time is 1s to 608399s (168 hours, 59 minut es, 59 seconds) . The gating time is always in seconds. Fractional sec o nds are not supported, and wil ...

  • Agilent Technologies N5980A - page 41

    Programming Reference Gating Progress :SENS1:GATE:STAT Syntax :SENS1:GATE:STAT? Description Requests the current state of the gating interval. It will return 1 while the gating is in progress and 0 if the gating is finished/ inactive. It is guaranteed that the very first :SENS1:GATE:STAT? query after the start of the gatin g period will report a va ...

  • Agilent Technologies N5980A - page 42

    Programming Reference Sample Code The following example code shows how to control the N5980A from within a remote program. The exampl e code is implemented in C#. The code snippets show the required code that needs to be added to a user program. It implements a class N5980A in the namespac e N5980AExample that allows communication with the N5980A u ...

  • Agilent Technologies N5980A - page 43

    Programming Reference /// </summary> public void Disconnect() { if (m_Client != null) m_Client.Close(); } /// <summary> /// Write to a SCPI command to a network socket and return the /// response if it was a query. /// </summary> /// <param name="s">SCPI command to be written to the socket</param> /// <ret ...

  • Agilent Technologies N5980A - page 44

    Programming Reference { /// <summary> /// The main entry point for the application. /// </summary> [STAThread] static void Main() { N5980A instrument = new N5980A(); // Connect to the N5980A software running on the same // PC as this program and that is using port number 5025 instrument.Connect("localhost", 5025); // set the d ...

Fabbricante Agilent Technologies Categoria Webcam

I documenti che otteniamo dal fabbricante del dispositivoAgilent Technologies N5980A possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Agilent Technologies
- manuali per l’uso N5980A
- schede prodotto Agilent Technologies
- opuscoli
- o etichette energetiche Agilent Technologies N5980A
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Agilent Technologies N5980A.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Agilent Technologies N5980A, manuali di manutenzione, brevi manuali o manuali utente Agilent Technologies N5980A. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Agilent Technologies N5980A.

Manuale completo del dispositivo Agilent Technologies N5980A, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Agilent Technologies N5980A dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Agilent Technologies N5980A.

Il manuale per l’uso completo Agilent Technologies, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Agilent Technologies N5980A - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Agilent Technologies N5980A, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Agilent Technologies N5980A che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Agilent Technologies N5980A - che ci dovrebbe aiutare nei primi passi durante l'uso Agilent Technologies N5980A
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Agilent Technologies N5980A
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Agilent Technologies N5980A in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Agilent Technologies N5980A?

Utilizza il modulo sottostante

Se non hai risolto il problema con Agilent Technologies N5980A con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Agilent Technologies N5980A è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)