Manuale per l’uso ResMed 248672

16 pagine 1.31 mb
Scarica

Vai alla pagina of 16

Summary
  • ResMed 248672 - page 1

    H4i ™ HEATED HUMIDIFIER User Guide English Global leaders in sleep and respiratory medicine www.resmed.com 248672/1 2013-02 H4i USER EUR 1 - ENG 1 2 4 5 Filling the wat er chamber / A uf füllen der Bef eucht er kammer / Remplissag e du r éservoir / Riempiment o della camera dell’acqua / Llenado de la cámar a de agua / Encher a câmar a de á ...

  • ResMed 248672 - page 2

    Manufa cturer: ResMed Ltd 1 Elizabeth Mac arthur Drive Bella Vista NSW 2153 A ustralia. Distributed by: ResMed Corp 9001 Spectrum Center Bou levard San Diego CA 92123 USA. ResMed (UK) Ltd 96 Milton Park Abi ngdon Oxfordshire OX14 4RY UK. See www. resmed.com for other ResMed locations worl dwide. For patent info rmation, see www.resmed.com /ip. H4i, ...

  • ResMed 248672 - page 3

    Cont ents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Indications for use 1 Contraindications 1 Components of your H4i . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 S etting up your H4 i for use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • ResMed 248672 - page 4

    1 Introduction English Introduction The H4i ™ is designed to moi sten the air delivered to your airway during Positive Airway Pressure (PAP) therapy. Indications for use The H4i is indicated for humidification of the air del ivered from a ResMed compatible CPAP, bilevel an d non-invasive ventilation device. The H4i is for use only as recommended ...

  • ResMed 248672 - page 5

    2 System setup 1 Align your H4i wi th your flow generator an d push them together until they c lick into place. 2 Connect the power cord to the socket on the rear of your flow generator. 3 Plug the other end of the power cord into the power outlet. Place the combined unit on a firm, level surfac e near your bed at a level lower than your sleeping p ...

  • ResMed 248672 - page 6

    3 Setting up your H4i for use English Filling the water chamber 1 Open the cover. 2 Remove the water chamber. 3 Fill with fresh, clean water up to or below the maxim um water level mark. Note: T he water c hamber must be remo ved from the H4i before it is filled or water may enter the flo w generator . The sp ill guard must also be in place. 4 Retu ...

  • ResMed 248672 - page 7

    4 4 Pull the H4i and flo w generator apart. Note : Re-attach the connector plug firmly to your flow generator. Starting and stopping treatment Warming your H4i with the VPAP or S8 Series The Warm-Up feature (not available on all Re sMed PAP d evices) is used to pre-heat the water before starting treatm ent. Skip this step if you want to start immed ...

  • ResMed 248672 - page 8

    5 Cleaning and maintenance English ! WARNING Do not leave a n excessive length of ai r tubing around the top o f your bed. It could twist around your head or neck while you are sleepin g. Stopping your treatment To stop your treatment, refer to your device user guid e. Note : In orde r to assist the heater plate in cooling, some flow generato rs co ...

  • ResMed 248672 - page 9

    6 Cleaning your H4i Water chamber Daily Wash the water chamber, spill guard, tub pl ate and tub plate seal in warm wate r, using a mild d etergent. Use the yellow cleanin g plug to assist in the clea ning process (see steps 1 to 4). Rinse thoro ughly in clean water and allow them to dry away from direct sunlight. Weekly The disassembled cl eanable ...

  • ResMed 248672 - page 10

    7 Cleaning and maintenance English Cover and cover seal 1 Remove the cover by gently flexing one cover arm away and up from the docking station until the cover detaches compl etely. 2 Peel the cover seal away from the cover. 3 Inspect the cover and cover seal weekly for wear and deteriorati on. Replace any damaged parts. When required, wa sh the co ...

  • ResMed 248672 - page 11

    8 4 Reinsert the sp ill guard into th e water chamber recess and pus h down to fit firmly into place. Reassembling your H4i Reassemble the parts when they are clean and dry. 1 Align the cover seal to the guides on the cover and press along the edges to ensure it is fitted properly. 2 Put one cover arm in to its pivot point on the docki ng station a ...

  • ResMed 248672 - page 12

    9 T roubleshooting English Troubleshooting If there is a p roblem, try the following suggestions. If the problem cannot b e solved, contact your equipment supplier or ResMed. Do not open the unit. ! WARNING Service and repair should only be pe rformed by a n authorise d service ag ent. Pro ble m Possible cause Sol ut i on Devi ce not w orking (no d ...

  • ResMed 248672 - page 13

    10 Technical specifications Humidifier performance The following setting s have been tested at 22°C, 40% RH ambient conditions: Note : The manufacturer reserves the right to cha nge these specifications without notic e. Maximum heate r plate temper atur e 85°C T emperatur e cut-out 93°C Maximum gas t emperatur e 41°C Dimensions (H x W x D) Doc ...

  • ResMed 248672 - page 14

    11 General warnings English Symbols which appear on the device Caution; Read instructions before use; European Authorised Representative; Type BF Applied Part; Hot surface; Class II equipment; Do not touch; Humidifier c ontrol; Max imum water level; Manufacturer; Environmenta l information WEEE 2002/96/EC is a E uropean Directive that requires the ...

  • ResMed 248672 - page 15

    12 Limited warranty ResMed Ltd (hereafter ’ResMed’) warrants that your ResMed product shall be free from defects in material and workmanship from the date of purchase for the period specified below. This warranty is only availabl e to the initial consumer. It is not transferable. If the product fails under conditions of norma l use, ResMed will ...

  • ResMed 248672 - page 16

    H4i ™ HEATED HUMIDIFIER User Guide English Global leaders in sleep and respiratory medicine www.resmed.com 248672/1 2013-02 H4i USER EUR 1 - ENG 1 2 4 5 Filling the wat er chamber / A uffüllen der Bef euchter kammer / Remplissage du r éservoir / Riempiment o della camera dell’acqua / Llenado de la cámar a de agua / Encher a câmar a de água ...

Fabbricante ResMed Categoria Oxygen Equipment

I documenti che otteniamo dal fabbricante del dispositivoResMed 248672 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici ResMed
- manuali per l’uso 248672
- schede prodotto ResMed
- opuscoli
- o etichette energetiche ResMed 248672
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso ResMed 248672.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione ResMed 248672, manuali di manutenzione, brevi manuali o manuali utente ResMed 248672. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto ResMed 248672.

Manuali per l’uso simili

Manuale completo del dispositivo ResMed 248672, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare ResMed 248672 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti ResMed 248672.

Il manuale per l’uso completo ResMed, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale ResMed 248672 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice ResMed 248672, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per ResMed 248672 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo ResMed 248672 - che ci dovrebbe aiutare nei primi passi durante l'uso ResMed 248672
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del ResMed 248672
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio ResMed 248672 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su ResMed 248672?

Utilizza il modulo sottostante

Se non hai risolto il problema con ResMed 248672 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con ResMed 248672 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)