Manuale per l’uso Agilent Technologies 60501B

11 pagine 0.1 mb
Scarica

Vai alla pagina of 11

Summary
  • Agilent Technologies 60501B - page 1

    OPERATING MANUAL 150 WATT ELECTRONIC LOAD MODULE Agilent Model 60501B FOR MO DULES WITH SERIAL NUMBERS: 3118A -00101 A ND A BOVE A gilent Part No. 60501-90009 Printed in U.S.A . Microf iche No. 60501-90010 June, 1991 ...

  • Agilent Technologies 60501B - page 2

    DECLA RA TION OF CONFORMI TY according to IS O/IEC G uide 22 and E N 45014 Manufacturer’s Name : Agilent Tec hnologies Manuf acturer’s A ddress: New Jersey Divi sion 140 Green Pond Road Rock away , NJ 07866 U.S.A. declares that the pr oduct Product Name: Load mainf ram e and m odules Model Number(s): Agilent 6050A, 6051A mainf ram es with m odu ...

  • Agilent Technologies 60501B - page 3

    1 150-Watt Module About This Manual This m anual provides in form ation for t he Ag ilent 60501B 150- Watt Electron ic Load Modul e. It is desig ned as a supplem ent to the A gilent 6050A /6051A Mu ltiple Input Mainf rame Electron ic Load Operating Man ual (part nu mber 06050- 90001). Four tabl es provide th e follow ing modu le-specif ic inf ormat ...

  • Agilent Technologies 60501B - page 4

    2 Table 60501-1. Specification and Supplemental Characteristics SPECIFICA TIO NS DC Input Rating: Current: 0 to 30 A Voltage : 3 to 60 V (min imu m dc operat ion from 0 to 2 V for 0 t o 30 A) Pow er: 150 W at 40 ° C (derated to 112 W at 55 ° C) A . OPERA TING CHARA CTERISTICS B. DERA TED CURRENT DETAIL Constant Current Mode: Ranges: 0 to 3 A; and ...

  • Agilent Technologies 60501B - page 5

    3 Table 60501-1 Specifications and Supplemental Characteristics (continued) Transient Operat ion: Continuous Mode Frequency Range: 0.25 Hz to 10 kHz Frequency Resolution: 4% Frequency A ccuracy : 3% Duty Cy cle Range: 3% to 97% (0.25 Hz to 1 k Hz); 6% to 94% (1 k Hz to 10 kHz) Duty Cy cle Resolution: 4% Duty Cycle A ccuracy : 6% of set ting ± 2% P ...

  • Agilent Technologies 60501B - page 6

    4 Table 60501-1 Specifications and Supplemental Characteristics (continued) External A nalog Programming 0 to 10 V (dc or ac): Bandwidth: 10 kHz (3 db freque ncy ) A ccuracy: ± 4.5% ± 40 m A (0 t o 3 A rang e) ± 4.5% ± 130 m A (0 to 30 A range) ± 0.8% ± 200 mV (0 to 60 V range) Temperature Coeffic ient: 100 ppm/ ° C ± 3 mA/ ° C (cu rrent r ...

  • Agilent Technologies 60501B - page 7

    5 Table 60501-1 Specifications and Supplemental Characteristics (continued) Current Slew Rate:* Rate # 30 A Range Step 3 A Range Step Transition T ime 1 0.5 A/m s 0.05 A/s 8.0 ms 2 1.2 A/m s 0.12 A/s 3.2 ms 3 2.5 A/m s 0.25 A/m s 1.6 ms 4 5 A/m s 0.5 A/m s 800 µ s 5 12 A/m s 1.2 A/m s 320 µ s 6 25 A/m s 2.5 A/m s 160 µ s 7 0.05 A/ µ s 5 A /m s ...

  • Agilent Technologies 60501B - page 8

    6 Table 60501-1 Specifications and Supplemental Characteristics (continued) Source Turn-On Current Overshoot: Less than 10% of fin al value (in CC and CR m odes w hen connected to pow er supplies with voltage rise times of greater than 500 µ s). Programmable Shor t Circuit: 0.066 Ω (0.04 Ω typical) Programmable Open Circuit: 20 k Ω (ty pical ...

  • Agilent Technologies 60501B - page 9

    7 Table 60501-2. Programming Ranges (continued) Transient O peration Set Frequency FREQ value " T RAN:FREQ value" 0.25 Hz to 10 kHz Set Duty Cy cle (shif t) DCYCLE v alue "TRAN: DCYC va lue" 3-97% (0.25 Hz- 1 kHz) 6-94% (1 k Hz-10 kH z) *S et Puls e Width "TRAN:TWID valu e" 0.00005 to 4 s Trigger Operat ion *S et Trigg ...

  • Agilent Technologies 60501B - page 10

    8 Table 60501-4. Calibration Info rmation Ranges and Calibration Points Variables Variables Value Power Supply Settings Current Shunt High C urrent R ange Hi_cu rr_rng 30 5 V/31 A 100 A High C urrent Of fset Hi_curr_off set 0.013 Low Cu rrent Ran ge Lo_curr_rn g 3 5 V/10 A 15 A Low Curren t Off set L o_curr_off set 0.013 Voltage Range N/A N/A 61 V/ ...

  • Agilent Technologies 60501B - page 11

    9 Agilent Sales and Support Office For more information about Agilent Technologies test and measurement products, applications, services, and for a current sales office listing, visit our web site: http://www.agilent.com/find/tmdir You can also contact one of the following centers and ask for a test and measurement sales representative. United Stat ...

Fabbricante Agilent Technologies Categoria Drums

I documenti che otteniamo dal fabbricante del dispositivoAgilent Technologies 60501B possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Agilent Technologies
- manuali per l’uso 60501B
- schede prodotto Agilent Technologies
- opuscoli
- o etichette energetiche Agilent Technologies 60501B
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Agilent Technologies 60501B.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Agilent Technologies 60501B, manuali di manutenzione, brevi manuali o manuali utente Agilent Technologies 60501B. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Agilent Technologies 60501B.

Manuale completo del dispositivo Agilent Technologies 60501B, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Agilent Technologies 60501B dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Agilent Technologies 60501B.

Il manuale per l’uso completo Agilent Technologies, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Agilent Technologies 60501B - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Agilent Technologies 60501B, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Agilent Technologies 60501B che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Agilent Technologies 60501B - che ci dovrebbe aiutare nei primi passi durante l'uso Agilent Technologies 60501B
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Agilent Technologies 60501B
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Agilent Technologies 60501B in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Agilent Technologies 60501B?

Utilizza il modulo sottostante

Se non hai risolto il problema con Agilent Technologies 60501B con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Agilent Technologies 60501B è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)