    WARNING : Improper installation, adjustment , alterat ion, service or maint enance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency or t he gas supplier . Upon completion of the installation, these instructions should be handed to the user of the applia ...

  • Bosch 125B LPS - page 2

    2 6 720 606 518 This well engineered, gas water heater has been specially designed to operate with incoming pre-heated water: It operates on the principle of heating water instantaneously “on demand”. When a hot water faucet is opened, cold water flows through the coils of the heat exchanger in the Aquast ar . This same flow opens the gas valve ...

  • Bosch 125B LPS - page 3

    3 6 720 606 518 D861_059 M I N I M U M I N S T ALLA TI ON C LE A R ANC ES F RO M C OM B U S TI B LE AN D N ON C OM B U S TI B LE MA TE R IAL S F O R AL COVE O R C L O S ET I NST ALLA TI O NS F RO NT VI EW S I DE VI EW AQU AST AR M ODE L 1 25B S MODEL 125BS TOP (A) 12 " FRONT (B) 4 " BACK 0 " SIDES 4 " FLOOR (C) 12 " VENT DI ...

  • Bosch 125B LPS - page 4

    4 6 720 606 518 PR OPER L OCA TION FOR I NST ALL I NG Y OU R HEA T ER C arefully select the location of your new heater. For your safety and for proper heater operation, you must provide an abundant supply of combustion air and a proper venting installation. The heater may still operate even when improperly vented. It will, however, be less efficie ...

  • Bosch 125B LPS - page 5

    5 6 720 606 518 WARNING: Flammable materials, gasoline, pressurized containers, or any other items or articles that are pot entially fire hazards must NOT be placed on or adjacent to the heater. The appliance area must be kept free of all combustible materials, gasoline and other flammable vapors and liquids. COMBUSTION AIR REQUIREMENTS The AquaSta ...

  • Bosch 125B LPS - page 6

    6 6 720 606 518 Fig. 1 - Mounting the Heater Fig. 2 - Incandescent Part icle T ray Illustrat ion The incandescent particle tray (shipped loose in the carton with the water heater) must be attached at the bottom of the water heater front cover at the time of installation. Use the screws provided. See figure 2 SUPPORT BOARD WALL STUDS 1” X 4 ” SP ...

  • Bosch 125B LPS - page 7

    7 6 720 606 518 VENTING V ent pipe connect ion. W AR NI NG : Do not reduce t he vent pipe size . S ee Fig. 3 for high alt itude inst allations The heater must be vented to the outside following all local ordinances and specifications for installing a gas appliance vent or chimney . The heater must be located as close as practicable to a vertically ...

  • Bosch 125B LPS - page 8

    8 6 720 606 518 MASO NRY CH I MN EY : Masonry chimneys shall be built and installed in accordance with N FP S 2 1 1 or local codes. A minimum 5” diameter gas vent pipe ( metal double wall T ype B ), or an approved clay flue liner or a listed c himney lining system must be used when venting into a naturally drafting, internal masonr y chimney . 6 ...

  • Bosch 125B LPS - page 9

    9 6 720 606 518 Fig. 3 – V ent Adaptor for High Altit ude Inst allations 5” X 6” ADAPT O R US ED ON HIGH A L TI TUD E T o check the draft : Close all doors and windows to the outside. T urn on all appliances that force air out of the building. These include all exhaust/ventilation fans, furnaces, clothes dryers, wood burning stoves, etc. Open ...

  • Bosch 125B LPS - page 10

    10 6 720 606 518 GAS CONNECTIONS and Gas Regulator NO TE: The Aquastar 1 25 B”S” is supplied wit h a gas pressure regulator that must be inst alled on t he heat er before attaching the gas supply line. See figure 5. Failure to install the gas regulator as shown in figure 5 will be a violation of CSA certificat ion of t he unit . T he regulator ...

  • Bosch 125B LPS - page 11

    11 6 720 606 518 The water heater must be isolated from the gas supply piping system by closing the manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or more than 0.5 psig. The water heater , including the pressure regulator provided with it, must not be operated at gas supply pressures in e ...

  • Bosch 125B LPS - page 12

    12 6 720 606 518 O PERA TIN G INST R U C T IONS Before proceeding with the operation of the heater make sure that the system is filled with water . Open the cold water inlet supply to the heater fully . Open a hot water faucet to permit the water to fill the heater and the piping and to eliminate the air trapped in the system Close the hot water fa ...

  • Bosch 125B LPS - page 13

    13 6 720 606 518 Fig. 8 - Characteristic Pilot Flame 3mm Correct gap between pilot burner tip and piezo electrode tip Piezo Electrode Air screen filter 1 0mm 3/8” Piezo Electrode Thermocouple T o clean t he pilot burner and/ or the pilot orifice : T urn off the gas at the unit . Remove the cover of the heater . T o do so, remove incandescent part ...

  • Bosch 125B LPS - page 14

    14 6 720 606 518 If some burners have yellow flames while others have good flames, it is likely that dust, lint or spider webs have partially clogged the burner venturis. Contact a gas service person to clean the remove and clean the burners. Mineral S c ale Build-up : The AquaStars heater , when operated at lower temperatures settings, do not accu ...

  • Bosch 125B LPS - page 15

    15 6 720 606 518 T o test the thermocouple , disconnect the thermocouple lead to the ECO. Insert a multi-meter probe into the thermocouple lead and attach or hold the other lead to the metal gas valve (DC common). Light the pilot flame and hold button, meter reading should be 24 mVDC or more. If the reading is 24 mVD C or more the thermocouple is g ...

  • Bosch 125B LPS - page 16

    16 6 720 606 518 See specifications on page 2. Unlike storage tank water heaters, the burners of a tankless water heater must be very powerful to heat water instantaneously since they do this only at the time hot water is actually being used. It is therefore imperative that the gas pressure requirement be met exactly . Insufficient gas pressure wil ...

  • Bosch 125B LPS - page 17

    17 6 720 606 518 1 . Heat exchanger 2 . Pilot assembly 3. Burner manifold gas pressure test nipple 4 . Main gas burner 5 . Pilot gas tubing 6 . Gas valve 7 . Piezo igniter 8 . Location of pressure tap screw 9. W ater valve 1 0. Gas inlet gas pressure test nipple 5 1 4 7 9 3 10 6 2 8 Fig. 1 0 - Diagram of AquaSt ar 1 25 BS ...

  • Bosch 125B LPS - page 18

    18 6 720 606 518 A Q 1 25 BS Fig. 1 1 - I NTER IO R COM P ONE NTS DIA G RAM AN D P ARTS LI S T ...

  • Bosch 125B LPS - page 19

    19 6 720 606 518 Fig. 1 1 INTERIOR COMPONENTS DIAGRAM AN D P ARTS LIST 1 25B S 1 Cov er 8 705 421 033 2 Cap cover 8 703 304 011 3 Water connection gasket 8 710 103 043 4 Draf t dive rtor 8 705 5 05 354 5 Heat exch anger 8 705 406 189 6 Hot w ater pipe 8 700 705 431 7 Cold water pipe 8 700 705 294 8 Heat exchang er w asher 8 710 103 045 9 Overheat s ...

  • Bosch 125B LPS - page 20

    20 6 720 606 518 Fig. 1 2 - Flow chart of Aquast ar 1 25 BS ...

  • Bosch 125B LPS - page 21

    21 6 720 606 518 LI M ITE D W AR R ANT Y Aquast ar General Aquastar water heaters are warranted by the Manufacturer ( BO SC H) through C ontrolled Energy Corp . C ontrolled Energy C orp. (C E C) will furnish a replacement heat exchanger and will furnish a replacement of any other part which fails in normal use and service within the applicable peri ...

  • Bosch 125B LPS - page 22

    VU L C ANO T ermod omést icos S.A. Estrada de Cacia 380 1 - 856 Aveiro - P ORTUGAL Recycled paper 3 1 e g a p e e s E L B A T E C N A N E T N I A M R A E Y Y R E V S E R A E Y 2 Y R E V S E R A E Y 5 - 3 Y R E V E E V L A V R E T A W E T A C I R B U L † E V L A V R E T A W D L I U B E R † N E E R C S R E T L I F R E T A W T C E P S N I † Y L ...

Fabbricante Bosch Categoria Water Heater

I documenti che otteniamo dal fabbricante del dispositivoBosch 125B LPS possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Bosch
- manuali per l’uso 125B LPS
- schede prodotto Bosch
- opuscoli
- o etichette energetiche Bosch 125B LPS
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Bosch 125B LPS.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Bosch 125B LPS, manuali di manutenzione, brevi manuali o manuali utente Bosch 125B LPS. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Bosch 125B LPS.

Manuali per l’uso simili

Manuale completo del dispositivo Bosch 125B LPS, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Bosch 125B LPS dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Bosch 125B LPS.

Il manuale per l’uso completo Bosch, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Bosch 125B LPS - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Bosch 125B LPS, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Bosch 125B LPS che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Bosch 125B LPS - che ci dovrebbe aiutare nei primi passi durante l'uso Bosch 125B LPS
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Bosch 125B LPS
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Bosch 125B LPS in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Bosch 125B LPS?

Utilizza il modulo sottostante

Se non hai risolto il problema con Bosch 125B LPS con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Bosch 125B LPS è probabile che voglia condividere il modo di risolverlo.