  • Bryant 116B - page 1

    1 16B Legacy t Line 16 Air C onditioner with Puron r Refrigeran t 1 - - 1/2 to 5 Nominal T ons Pr oduct Data the environmentally sound refrigerant Brya nt ’ s Air Condit i oner s wi t h Puron r re f r ige r a nt pr ovi de a collectio n o f features un match ed b y any oth er family of equ ip men t. T h e 116 B has b een d esign ed utilizin g Bry ...

  • Bryant 116B - page 2

    2 MODEL NUMBER NOMENCLA TURE 1 2 34 5 6 7 8 9 1 0 1 11 2 1 4 N N N A A/N N N N N A/N A/N N A 1 1 6B N A 0 3 60 0 0 0 Prod- uct Fam il y Tier SEER Major Serie s Vo l t a g e Gr ille Va r i a t i o n s Cooling C apacit y Open Open Open S eries 1=AC 1= Leg ac y RNC 6=16 SEER B=Puron N= 208 - - - 230 - - - 1 or 208/230 - - - 1 A=D e n s e 0=Not Defined ...

  • Bryant 116B - page 3

    3 REFRIGERANT PIP ING LENGTH LIMI T A TIONS Liquid Line Sizing and Maximum T otal Equival e nt Le ngths { for Coo ling O n ly Sy stems with P uron r Refrig era nt : The ma xim um all owa bl e le ngt h of a re si de nt ia l spli t s ys te m depe nds on the l iqui d line di a me t er and ver t ic a l se par a t ion bet we e n indoor and outdoor uni t ...

  • Bryant 116B - page 4

    4 REFRIGERANT CHARGE ADJUSTMENTS Liquid Line S ize Puron Charge oz /ft 3/8 0.60 (F actory charg e for lineset = 9 oz) 5/16 0.40 1/4 0.27 Unit s a re fac t or y cha r ged f or 15 f t ( 4.6 m) of 3/8” liqui d li ne . The fa c t ory c ha r ge for 3/8” li ne se t 9 oz. When us ing othe r l engt h or di am et e r li qui d line s , cha r ge adj ust m ...

  • Bryant 116B - page 5

    5 ACCESSO R Y THERMOS T A TS PA R T N U M B E R PRO GR AM GAS ELECTRIC HEA T COOL T 2 --- P A C 0 1 5 --- 2 D a y √ √ 1 1 T 2 --- N A C 0 1 NP √ √ 1 1 T2SNA C0 1 NP √ √ 1 1 THER MOS T AT ACCE SSORI ES PA R T N U M B E R BRIEF DESCRIPT ION THE RMOSTATS USED WI TH TST A TXXCNV10 The rm ost at C on ve r sion K it (4 to 5 wir e ) - - - 10 p ...

  • Bryant 116B - page 6

    6 ACCESSO R Y USAGE GUIDELI NE ACCESSORY RE QUIRE D FOR LOW - - - AMBI - ENT COOLING APPLIC ATIONS (Below 55 ° F/12. 8 _ C) RE QUIRE D FOR LONG LINE APPLICATIONS* (Ov er 80 ft ./ 24. 38 m) REQUI RED FOR SEA COA ST APPLICATIONS ( W i t h i n2m i l e s / 3 . 2 2k m ) Ball Be ar ing Fan Motor Ye s { No No Compressor St art Assist C apa citor and R el ...

  • Bryant 116B - page 7

    7 Ac ce ss or y De sc r iptio n and Us age (List ed A lphabe tic ally ) ( Co ntinue d) 10. Sound Hood W r apa r ound s ound re duc i ng cove r for the c ompr es s or . Re duc e s the sound le ve l by a bout 2 dBA. Us age G uide l ine : Sugges t e d whe n unit is ins t a ll e d cl os e r t ha n 15 ft ( 4. 57 m) t o qu iet areas, b ed ro om s, etc. S ...

  • Bryant 116B - page 8

    8 ELECTRICAL DA T A UNIT S IZE V/PH OPER VOL TS* COMP R FA N MCA MIN WIR E SIZE { 60 ° C MIN WIR E SIZE { 75 ° C MAX LENG TH ft. (m) } 60 ° C MAX LENG TH ft. (m) } 75 ° C MAX FUSE ** or CKT B RK AMPS MAX MIN LRA RLA FLA 018 - - - B 208/230/1 - - - 60 253 197 48.0 9.0 0.50 11.8 14 14 67 (20.4) 64 (19.5) 20 024 - - - A 58.3 13.5 0.75 17.7 14 14 4 ...

  • Bryant 116B - page 9

    9 DIMENSIONS - - ENGLISH B 3" K 5/16" L C 3 1/2" 1 7/8" N P M E F G A 208-230-1-60 230-1-60 208/230-3-60 460-3-60 UNIT SERIES ELECTRICAL CHARACTERISTICS AB C D EF G K L M NP OPERATING WEIGHT (lbs) SHIPPING WEIGHT (lbs) SHIPPING DIMENSIONS (L x W x H) 116BNA018 A X O O O 23 1/8" 28 11/16" 3 3/4" 3/4" 4 7/16&qu ...

  • Bryant 116B - page 10

    10 DIMENSIONS - - SI B C 88.9 47.6 P A 76.2 K 8.0 L N M E F G 208-230-1-60 230-1-60 208/230-3-60 460-3-60 UNIT SERIES ELECTRICAL CHARACTERISTICS AB C D EF G K L M N P OPERATING WEIGHT (Kgs) SHIPPING WEIGHT (Kgs) SHIPPING DIMENSIONS (L x W x H) 116BNA018 A X O O O 587.3 728.7 95.2 19.0 112.7 458.8 198.4 71.4 12.7 330.2 304.8 330.2 53.4 64.0 616.0 X ...

  • Bryant 116B - page 11

    11 CLEARANCES Clearances (various examples) W all 6” (152.4) 24” (609.6) Service W all W all W all 12” (304.8) 12” (304.8) 18” (457.2) 24” (609.6) Service 6” (152.4) 12” (304.8) 24” (609.6) Service 24” (609.6) Service 24” (609.6) Service Note: Numbers in ( ) = mm 18” (457.2) 18” (457.2) 12” (304.8) IMPOR T ANT : W hen in ...

  • Bryant 116B - page 12

    12 TESTED AHRI COMBINA TION RA TINGS* NOTE: Ratings contained in th is documen t are subject to change at any time. For AHRI ratings certificates, please r efer to the AHRI dir ectory www .ahridirectory .org Additional rati ngs and system combinations can be accessed via the Bryant database at: http://cacta xcredits.info/bry ant-ratings/hp_ ratings ...

  • Bryant 116B - page 13

    13 DET AILED COOLING CAP ACITIES # EVAPORA TOR AIR CO ND ENS ER ENT ERI N G AI R TEM PER ATURES ° F (° C ) 75 (23.9) 85 (29.4) 95 (35) 105 (40.6) 115 (46.1) 125 (51.7) CFM EWB °F ( °C ) Capacity MBtuh† To t a l Syst em KW** Capacity MBtuh† To t a l Syst em KW** Capacity MBtuh† To t a l Syst em KW** Capacity MBtuh† To t a l Syst em KW** ...

  • Bryant 116B - page 14

    14 DET AILED COOLING CAP ACITIES # (CONT .) EVAPORA TOR AIR CO ND ENS ER ENT ERI N G AI R TEM PER ATURES ° F (° C ) 75 (23.9) 85 (29.4) 95 (35) 105 (40.6) 115 (46.1) 125 (51.7) CFM EWB °F ( °C ) Capacity MBtuh† To t a l Syst em KW** Capacity MBtuh† To t a l Syst em KW** Capacity MBtuh† To t a l Syst em KW** Capacity MBtuh† To t a l Syst ...

  • Bryant 116B - page 15

    15 DET AILED COOLING CAP ACITIES # (CONT .) EVAPORA TOR AIR CO ND ENS ER ENT ERI N G AI R TEM PER ATURES ° F (° C ) 75 (23.9) 85 (29.4) 95 (35) 105 (40.6) 115 (46.1) 125 (51.7) CFM EWB °F ( °C ) Capacity MBtuh† To t a l Syst em KW** Capacity MBtuh† To t a l Syst em KW** Capacity MBtuh† To t a l Syst em KW** Capacity MBtuh† To t a l Syst ...

  • Bryant 116B - page 16

    16 DET AILED COOLING CAP ACITIES # (CONT .) EVAPORA TOR AIR CO ND ENS ER ENT ERI N G AI R TEM PER ATURES ° F (° C ) 75 (23.9) 85 (29.4) 95 (35) 105 (40.6) 115 (46.1) 125 (51.7) CFM EWB °F ( °C ) Capacity MBtuh† To t a l Syst em KW** Capacity MBtuh† To t a l Syst em KW** Capacity MBtuh† To t a l Syst em KW** Capacity MBtuh† To t a l Syst ...

  • Bryant 116B - page 17

    17 DET AILED COOLING CAP ACITIES # (CONT .) EVAPORA TOR AIR CO ND ENS ER ENT ERI N G AI R TEM PER ATURES ° F (° C ) 75 (23.9) 85 (29.4) 95 (35) 105 (40.6) 115 (46.1) 125 (51.7) CFM EWB °F ( °C ) Capacity MBtuh† To t a l Syst em KW** Capacity MBtuh† To t a l Syst em KW** Capacity MBtuh† To t a l Syst em KW** Capacity MBtuh† To t a l Syst ...

  • Bryant 116B - page 18

    18 CONDENSER ONL Y RA TI NGS SST °F ( °C ) CONDENS ER ENTERING AIR TEMPERAT URES ° F (° C) 55 (12.78) 65 (18.33) 75 ( 23.89) 85 ( 29.44) 95 (35.0) 105 (40.56) 115 (46.11) 125 (51. 67) 116BNA018 ****B 30 ( - - - 1. 11) TCG 15.70 14.90 14.10 13.20 12.30 11.30 10.20 9.20 SDT 66.60 76.20 85.80 95.30 104.80 114.30 123.70 133.10 KW 0.75 0.87 0.99 1.1 ...

  • Bryant 116B - page 19

    19 CONDENSER ONL Y RA TI NGS CONTINUED SST °F ( °C ) CONDENS ER ENTERING AIR TEMPERAT URES ° F (° C) 55 (12.78) 65 (18.33) 75 ( 23.89) 85 ( 29.44) 95 (35.0) 105 (40.56) 115 (46.11) 125 (51. 67) 116BNA036 ****A 30 ( - - - 1. 11) TCG 31.50 29.90 28.30 26.60 24.80 22.90 21.00 18.90 SDT 68.90 78.20 87.50 96.80 106.20 115.50 124.90 134.20 KW 1.50 1. ...

  • Bryant 116B - page 20

    20 CONDENSER ONL Y RA TI NGS CONTINUED SST °F ( °C ) CONDENS ER ENTERING AIR TEMPERAT URES ° F (° C) 55 (12.78) 65 (18.33) 75 ( 23.89) 85 ( 29.44) 95 (35.0) 105 (40.56) 115 (46.11) 125 (51. 67) 116BNA049 ****A 30 ( - - - 1. 11) TCG 45.00 42.40 39.90 37.40 34.90 32.30 29.50 26.40 SDT 70.30 79.50 88.90 98.20 107.60 116.90 126.20 135.40 KW 2.04 2. ...

  • Bryant 116B - page 21

    21 GUI D E SPEC I FIC A TI ON S GENERAL Sy stem D escriptio n Outdoor- - mount ed, a i r- - coole d, spl i t- - sys t e m ai r cond it i one r unit sui t a ble f or gr ound or rooft op ins t al l a ti on. Uni t cons i s ts of a her me tic com pre s s or , a n ai r- - cool e d coi l , pr opel l e r- - type conde ns e r fa n, a nd a cont rol box. Uni ...

  • Bryant 116B - page 22

    22 SYSTE M DE SIGN SU MMA R Y 1. Int e nde d for outdoor i ns ta l l at i on wi th f r e e a i r inl e t a nd out l et . Out door f a n e xte r na l s t a ti c pr es s ur e a va i la bl e is les s t han 0. 01- - in. wc . 2. Mi nim um outdoor ope ra t i ng air t e mpe r at ur e f or cool i ng mode wit hout l ow- - ambi e nt oper a t ion accessory is ...

Fabbricante Bryant Categoria Air Conditioner

I documenti che otteniamo dal fabbricante del dispositivoBryant 116B possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Bryant
- manuali per l’uso 116B
- schede prodotto Bryant
- opuscoli
- o etichette energetiche Bryant 116B
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Bryant 116B.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Bryant 116B, manuali di manutenzione, brevi manuali o manuali utente Bryant 116B. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Bryant 116B.

Manuali per l’uso simili

Manuale completo del dispositivo Bryant 116B, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Bryant 116B dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Bryant 116B.

Il manuale per l’uso completo Bryant, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Bryant 116B - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Bryant 116B, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Bryant 116B che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Bryant 116B - che ci dovrebbe aiutare nei primi passi durante l'uso Bryant 116B
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Bryant 116B
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Bryant 116B in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Bryant 116B?

Utilizza il modulo sottostante

Se non hai risolto il problema con Bryant 116B con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Bryant 116B è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)