    UL TRAPROBE TM 100 INSTRUCTION MANUAL VOLUME 1.3 ...

  • Alpine VOLUME 1.3 - page 2

    NEED HELP??? HA VE QUESTIONS?? AT UE SYSTEMS, WE ARE DEDICATED TO SUPPORTING OUR ULTRAPROBE USERS. OUR STAFF HAS YEARS OF FIELD EXPERIENCE AND IS STANDING READY TO ASSIST YOU SHOULD YOU NEED US. WHEREVER YOU ARE, REMEMBER, WE ARE AS CLOSE AS YOUR PHONE, FAX OR COMPUTER. CALL: 914-592-1220 FAX: 914-347-2181 Email: ue@worldnet.att.net Internet: http: ...

  • Alpine VOLUME 1.3 - page 3

    The ULTRAPROBE 100 provides easy, accurate leak detection and mechanical inspection through advanced ultrasonic technology. Before you begin testing, it is advisable to familiarize yourself with the basic components of your kit. 1. PISTOL HOUSING The main component of the Ultraprobe is its' pistol housing. From back to front, let's examin ...

  • Alpine VOLUME 1.3 - page 4

    2. SCANNING MODULE This module is utilized to receive air-borne ultrasound such as the ultrasounds emitted by pressure leaks and electrical discharges. To use, make sure it is plugged in to the front end of the metered pistol housing by aligning the plug with the receptical and inserting it firmly. To use the Scanning Module: 1. Plug in to front en ...

  • Alpine VOLUME 1.3 - page 5

    To use the WARBLE TONE GENERATOR : 1. Turn Tone Generator on by selecting either "LOW" for a low amplitude signal (usually recom mended for small containers) or "HIGH" for high amplitude. In high, the Warble Tone Generator will cover up to 4,000 cubic feet (121.9 cu. meters) of unobstructed space. When the Tone Generator is on, ...

  • Alpine VOLUME 1.3 - page 6

    -4- UL TRAPROBE APPLICA TIONS 1. LEAK DETECTION This section will cover airborne leak detection of pressure and vacuum systems. (For information concerned with internal leaks such as in Valves and Steam Traps, refer to the appropriate sections). What produces ultrasound in a leak? When a gas passes through a restricted orifice under pressure, it is ...

  • Alpine VOLUME 1.3 - page 7

    -5- B. TO CONFIRM A LEAK: Position the Scanning Module, or the rubber focusing probe (if it is on the scanning module) close to the suspect leak site and move it, slightly, back and forth, in all directions. If the leak is at this location, the sound will increase and decrease in intensity as you sweep over it. In some instances, it is useful to po ...

  • Alpine VOLUME 1.3 - page 8

    -6- D. LOW LEVEL LEAKS In ultrasonic inspection of leakage, the amplitude of the sound often depends upon the amount of turbulence generated at the leak site. The greater the turbulence, the louder the signal, the less the turbulence, the lower the intensity of the signal. When a leak rate is so low that it produces little, if any turbulence that i ...

  • Alpine VOLUME 1.3 - page 9

    The Tone Test incorporates two basic components: a TONE GENERATOR (an ultrasonic transmitter) , and the Scanning Module in the Ultraprobe. To conduct the test: 1. Make certain the test item has no fluids or contaminants such as water, mud, sludge, etc., that can block the path of the transmitted ultrasound. -7- 2. Place the Tone Generator within th ...

  • Alpine VOLUME 1.3 - page 10

    2. ELECTRIC ARC, CORONA, TRACKING DETECTION There are three basic electrical problems that are detected with the Ultraprobe 500: Arcing: An arc occurs when electricity flows through space. Lightning is a good example. Corona: When voltage on an electrical conductor, such as an antenna or high voltage transmission line exceeds the threshold value, t ...

  • Alpine VOLUME 1.3 - page 11

    3. DETECTING BEARING WEAR Ultrasonic inspection and monitoring of bearings is by far the most reliable method for detecting incipient bearing failure. The ultrasonic warning appears prior to a rise in temperature or an increase in low frequency vibration levels. Ultrasonic inspection of bearings is useful in recognizing: a. The beginning of fatigue ...

  • Alpine VOLUME 1.3 - page 12

    DETECTING BEARING FAILURE COMPARATIVE TESTING. The comparative method involves testing two or more similar bearings and "com- paring" potential differences. FOR COMPARATIVE TEST 1. Use contact (stethoscope) module. 2. Select a "test spot" on the bearing housing. Touch that spot with the contact module. In ultrasonic sensing, the ...

  • Alpine VOLUME 1.3 - page 13

    5. LOCATING FAULTY STEAM TRAPS An ultrasonic test of steam traps is a positive test. The main advantage to ultrasonic testing is that it isolates the area being tested by eliminating confusing background noises. A user can quickly adjust to recognizing differences among various steam traps, of which there are three basic types: mechanical, thermost ...

  • Alpine VOLUME 1.3 - page 14

    THERMOSTATIC TRAPS (bellows & bimetallic) operate on a difference in temperature between condensate and steam. They build up condensate so that the temperature of condensate drops down to a certain level below saturation temperature in order for the trap to open. By backing up condensate, the trap will tend to modulate open or closed depending ...

  • Alpine VOLUME 1.3 - page 15

    6. LOCATING FAULTY VALVES Utilizing the contact (stethoscope) module in the Ultraprobe, valves can easily be monitored to determine if a valve is operating properly. As a liquid or gas flows through a pipe, there is little or no turbulence generated except at bends or obstacles. In the case of a leaking valve, the escaping liquid or gas will move f ...

  • Alpine VOLUME 1.3 - page 16

    ULTRASOUND TECHNOLOGY The technology of ultrasound is concerned with sound waves that occur above human perception. The average threshold of human perception is 16,500 Hertz. Although the highest sounds some humans are capable of hearing is 21,000 Hertz, ultrasound technology is usually concerned with frequencies from 20,000 Hertz and up. Another w ...

  • Alpine VOLUME 1.3 - page 17

    SPECIFICA TIONS Construction : Hand held ABS pistol type ultrasonic processor stainless steel sensor enclosures Circuitry: SMD/Solid State hybrid hetrodyne receiver Frequency Response: 20-100 kHz (centered at 28-42 kHz) Indicator: 10 segment LED bargraph (red) Sensitivity Selection: 8 position precision attenuation Power: 9 volt alkaline battery Lo ...

  • Alpine VOLUME 1.3 - page 18

    SAFETY ADVISOR Y PLEASE READ BEFORE USING YOUR INSTRUMENT . W ARNING Improper use of your ultrasonic detector may result in death or serious injury . Observe all safety precautions. Do not attempt to make any rep airs or adjustments while the equipment is operating. Be sure to turn off and LOCK OUT all electrical and mechanical sources before perfo ...

Fabbricante Alpine Categoria Impact Driver

I documenti che otteniamo dal fabbricante del dispositivoAlpine VOLUME 1.3 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Alpine
- manuali per l’uso VOLUME 1.3
- schede prodotto Alpine
- opuscoli
- o etichette energetiche Alpine VOLUME 1.3
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Alpine VOLUME 1.3.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Alpine VOLUME 1.3, manuali di manutenzione, brevi manuali o manuali utente Alpine VOLUME 1.3. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Alpine VOLUME 1.3.

Manuali per l’uso simili

Manuale completo del dispositivo Alpine VOLUME 1.3, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Alpine VOLUME 1.3 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Alpine VOLUME 1.3.

Il manuale per l’uso completo Alpine, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Alpine VOLUME 1.3 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Alpine VOLUME 1.3, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Alpine VOLUME 1.3 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Alpine VOLUME 1.3 - che ci dovrebbe aiutare nei primi passi durante l'uso Alpine VOLUME 1.3
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Alpine VOLUME 1.3
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Alpine VOLUME 1.3 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Alpine VOLUME 1.3?

Utilizza il modulo sottostante

Se non hai risolto il problema con Alpine VOLUME 1.3 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Alpine VOLUME 1.3 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)