    Installation Manual 1550 UNIVERSAL BEER DISPENSER (R-404A REFRIGERANT) PRINTED IN U.S.A IMI CORNELIUS INC; 1998–99  IMI CORNELIUS INC g One Cornelius Place g Anoka, MN 55303-6234 T elephone (800) 238-3600 Facsimile (612) 422-3246 Part No. 569000246 August 1 1, 1998 Revised: June 1 1, 1999 Control Code A THIS DOCUMENT CONT AINS IMPOR T ANT INFO ...

  • Cornelius 1550 - page 2

    i 569000246 T ABLE OF CONTENTS Page SAFETY INFORMA TION 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RECOGNIZE SAFETY INFORMA TION 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UNDERST AND SIGNAL WORDS 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Cornelius 1550 - page 3

    ii 569000246 T ABLE OF CONTENTS (cont ’ d) Page SERVICE AND MAINTENANCE 15 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PREP ARING UNIT FOR SHIPPING, RELOCA TING, OR ST ORING 15 . . . . . . . . . . ADJUSTMENTS 15 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Cornelius 1550 - page 4

    1 569000246 SAFETY INFORMA TION Recognize Safety Information This is the safety-alert symbol. When you see this symbol on our machine or in this manual, be alert to the potentially of personal injury . Follow recommended precautions and safe operating practices. DANGER Understand Signal Words A signal word - DANGER, W ARNING, OR CAUTION is used wit ...

  • Cornelius 1550 - page 5

    ...

  • Cornelius 1550 - page 6

    2 569000246 THIS P AGE LEFT BLANK INTENTIONALL Y ...

  • Cornelius 1550 - page 7

    3 569000246 GENERAL INFORMA TION IMPORT ANT : T o the user of this manual – This manual is a guide for installing, operating, and main- taining this equipment. Refer to the T able of Contents for page location for detailed information per- taining to questions that arise during installation, operation, service, or maintenance of this equip- ment. ...

  • Cornelius 1550 - page 8

    4 569000246 T able 1. Design Data (cont ’ d) Electrical Requirements: Operating V oltage See Unit Nameplate Current Draw See Unit Nameplate THEOR Y OF OPERA TION ( see Figure 2 ) A CO 2 cylinder delivers carbon dioxide (CO 2 ) gas through adjustable CO 2 regulators to the beer kegs. When dispensing valves are opened, CO 2 gas pressure exerted upo ...

  • Cornelius 1550 - page 9

    5 569000246 CO 2 GAS CHECK V A L VE (2) BEER KEG (2) CO 2 CYLINDER LINE LEGEND BEER CO 2 PRIMAR Y CO 2 REGULA T OR BEER KEG SECONDARY CO 2 REGULA T OR (2) CO 2 SHUT OFF V A L VE (2) BEER KEG T APPER (2) 1 2 1550 UNIVERSAL BEER DISPENSER DISPENSING F AUCET (2) COIL NO. 1 COIL NO. 2 NO. 2 NO. 1 SEE NOTE 2 SEE NOTE 1 SYRUP T AN K CO 2 QUICK DISCONNECT ...

  • Cornelius 1550 - page 10

    ...

  • Cornelius 1550 - page 11

    6 569000246 THIS P AGE LEFT BLANK INTENTIONALL Y ...

  • Cornelius 1550 - page 12

    7 569000246 INST ALLA TION This section covers unpacking and inspection, selecting location, installing Unit, preparing for operation, and operation. UNP ACKING AND INSPECTION NOTE: The Unit was thoroughly inspected before leaving the factory and the carrier has accepted and signed for it. Any damage or irregularities should be noted at the time of ...

  • Cornelius 1550 - page 13

    8 569000246 2. The Unit must be installed near a properly grounded electrical outlet with proper electrical require- ments.The electrical circuit must be properly fused (slow-blow type fuse) or the circuit must be connected through an equivalent HACR circuit breaker .The electrical outlet must be accessible for ease of connecting and disconnecting ...

  • Cornelius 1550 - page 14

    9 569000246 6. Make sure the main power switch (1 15 V AC, 60 Hz Unit), located on back side of the Unit, is in the “ OFF ” (down) position. 7. Plug Unit power cord into electrical outlet. If Unit is 1 15 V AC, 60 Hz, place main power switch on back side of the Unit in “ ON ” position. 8. The compressor , condenser fan motor, and the agitat ...

  • Cornelius 1550 - page 15

    10 569000246 3. Open the CO 2 cylinder shutof f valve slightly to allow the primary CO 2 regulator to fill with gas, then open the valve fully to back-seat the valve. Back-seating the valve prevents leakage around the valve shaft. 4. Adjust the primary CO 2 regulator by loosening the regulator adjusting screw lock nut, then turn the adjust- ing scr ...

  • Cornelius 1550 - page 16

    569000246 11 OPERA T OR ’ S INSTRUCTIONS This section covers operating controls, pre-operation check, Unit operation, and maintenance procedures that may be performed by the Operator . IMPORTANT : Only qualified Personnel should service internal components of the Unit. PROPER BEER ST ORAGE Beer is a perishable product that can be materially chang ...

  • Cornelius 1550 - page 17

    569000246 12 BEER F AUCET (2) UNIT POWER SWITCH (1 15 V AC, 60 HZ UNIT ONL Y) DRIP TRA Y/CUP REST FIGURE 3. 1550 UNIVERSAL BEER DISPENSER OPERA TING CLEARANCES Check area in front, back, sides, and above the Unit for obstructions. These areas must be kept clear at all times. Listed below are the minimum clearances that must be maintained. A. Cleara ...

  • Cornelius 1550 - page 18

    569000246 13 An excessive accumulation of dust, lint, and grease on the condenser coil will restrict air flow through the coil which will decrease cooling efficiency of the Unit. The Unit condenser coil should be periodically cleaned to maintain cooling ef ficiency of the Unit. Contact a qualified Service Person to clean the Unit condenser coil. CH ...

  • Cornelius 1550 - page 19

    ...

  • Cornelius 1550 - page 20

    569000246 14 THIS P AGE LEFT BLANK INTENTIONALL Y ...

  • Cornelius 1550 - page 21

    569000246 15 SER VICE AND MAINTENANCE This section describes the service and maintenance procedures to be performed on the Unit. IMPORTANT : Only qualified Personnel should service the Unit internal components or electrical wiring. W ARNING: Disconnect electrical power from the Unit to prevent personnel injury before attempting any internal mainten ...

  • Cornelius 1550 - page 22

    569000246 16 UNIT BEER INLET LINES (2) POWER CORD T OP COVER BEER F AUCET (2) CUP REST DRIP TRA Y AIR INT AK E RET AINING SCREW (4) ACCESS GRILLE (4) DRIP TRA Y DRAIN HOSE W A TER T ANK OVERFLOW TUBE W A TER T ANK DRAIN HOSE PLUG COVER RET AINING SCREW (4) V A L VE TRIM P ANEL DRIP TRA Y DRAIN HOSE UNIT POWER SWITCH (1 15 V AC UNIT ONL Y) FIGURE 4. ...

  • Cornelius 1550 - page 23

    569000246 17 BEER INLET LINES (2) ELECTRICAL CONTROL BOX POWER CORD RET AINING SCREW TERMINAL BLOCK CONDENSER COIL UNIT POWER SWITCH (1 15 V AC UNIT ONL Y ) COMPRESSOR CONDENSER F AN MOTOR ACCESS GRILLE FIGURE 5. P ARTS IDENTIFICA TION ...

  • Cornelius 1550 - page 24

    569000246 18 Adjusting Beer Kegs Secondary CO 2 Regulators. Beer kegs secondary CO 2 regulators pressures adjustments require calculations of each beer system total beer system pressure. T otal beer system pressure, required to push beer from keg to faucet, is the result of comput- ing length of beer line of a certain size, vertical line lift, and ...

  • Cornelius 1550 - page 25

    569000246 19 2. Remove four screws securing air intake grille on the Unit front panel, then remove the grille. 3. V acuum or use a soft brush to clean the condenser coil. If available, use low-pressure compressed air . 4. Install air intake grille on the Unit and secure with four screws. 5. Plug Unit power cord into electrical outlet. CHECKING ICE ...

  • Cornelius 1550 - page 26

    569000246 20 8. Using a fiber brush, carefully clean mineral deposit build-up from the agitator motor shaft and the ice bank sensing bulb. 9. Rinse all parts and flush water tank with clean water . 10. Install plug in end of the water tank drain hose, then place drain hose back inside the Unit. 1 1. Place end of the Unit water tank overflow tube in ...

  • Cornelius 1550 - page 27

    569000246 21 5. Connect tank containing detergent solution into the beer system. 6. Place waste container under applicable beer faucet. 7. Activate the beer faucet to permit detergent solution to purge beer out of the line, coil, and the beer faucet. Continue to dispense until all beer has been purged from the beer system and only detergent solutio ...

  • Cornelius 1550 - page 28

    569000246 22 W ARNING: CO 2 displaces oxygen. Strict attention must be observed in the prevention of CO 2 (carbon dioxide) gas leaks in the entire CO 2 and soft drink system. If a CO 2 gas leak is suspected, particularly in a small area, immediately ventilate the contaminated area before attempting to repair the leak. Personnel exposed to high conc ...

  • Cornelius 1550 - page 29

    569000246 23 CLEANING CO 2 GAS CHECK V AL VE (see Figures 2 and 7) CO 2 gas check valves must be inspected and serviced at least once a year under normal conditions and after any servicing or disruption of the CO 2 system. AL WA YS REPLACE QUAD RING SEALS EACH TIME CHECK V AL VES ARE SER VICED. ...

  • Cornelius 1550 - page 30

    569000246 24 FIGURE 8. WIRING DIAGRAM ...

  • Cornelius 1550 - page 31

    25 569000246 TROUBLESHOOTING IMPORTANT : Only qualified Personnel should service internal components or electrical wiring. W ARNING: If repairs are to be made to the beer system, close shutoff valve in applicable beer inlet line, then relieve system pressure before proceeding. If repairs are to be made to the CO 2 system, shut off CO 2 supply , shu ...

  • Cornelius 1550 - page 32

    26 569000246 T rouble Remedy Probable Cause DISPENSED BEER FLOW RA TE T OO HIGH. A. Beer faucet not properly adjusted for beer flow rate. A. Adjust dispensed beer flow rate as instructed. OFF-TASTE BEER (SOUR AND UNP ALA T ABLE). A. Beer system needs to be cleaned and sanitized. A. Clean and sanitize beer system as instructed. B. Beer spoilage (sec ...

  • Cornelius 1550 - page 33

    27 569000246 T rouble Probable Cause Remedy TROUBLESHOOTING COOLING UNIT REFRIGERA TION SYSTEM COMPRESSOR DOES NOT OPERA TE. A. Glycol (coolant) sufficiently cooled. A. Refrigeration not called for . B. Cooling Unit POWER switch in ‘‘ OFF ’’ (down) position. B. Place Cooling Unit POWER switch in ‘‘ ON ’’ (up) position. C. No power s ...

  • Cornelius 1550 - page 34

    28 569000246 T rouble Remedy Probable Cause REFRIGERA TION COMPRESSOR NOT OPERA TING A. Refrigeration system overheated. Clogged condenser coil air intake filter . A. Clean air filter as instructed. B. Refrigeration system overheated. Condenser fan motor not operating. B. Replace condenser fan motor . C. Glycol tank temperature control sensor inope ...

  • Cornelius 1550 - page 35

    29 569000246 IMI CORNELIUS INC . O NE C ORNELIUS P LACE A NOKA, MN . 55303 – 6234 T ELEPHONE ( 800) 238 – 3600 F ACSIMILE (612) 422 – 3232 W ARRANTY IMI Cornelius Inc. warrants that all equipment and parts are free from defects in material and workman- ship under normal use and service. For a copy of the warranty applicable to your Cornelius ...

  • Cornelius 1550 - page 36

    IMI CORNELIUS INC. CORPORA TE HEADQUARTERS: One Cornelius Place Anoka, Minnesota 55303-6234 (612) 421-6120 (800) 238-3600 301 137000 ...

メーカー Cornelius カテゴリー Beverage Dispenser

Cornelius 1550のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 1550の取扱説明書
- Corneliusの製品カード
- パンフレット
- またはCornelius 1550の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Cornelius 1550の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Cornelius 1550の取り付け説明書、サービスマニュアル、簡易説明書、またはCornelius 1550のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Cornelius 1550の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Cornelius 1550デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがCornelius 1550を使用するのを助ける技術的文書のことです。説明書は通常、全てのCornelius 1550ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Corneliusの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Cornelius 1550の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははCornelius 1550の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Cornelius 1550に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Cornelius 1550デバイスの基本機能を使うにあたってのヒント。 Cornelius 1550のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Cornelius 1550に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるCornelius 1550のメーカー/サービスへの連絡先に関する情報。

Cornelius 1550についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもCornelius 1550の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがCornelius 1550で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)