    INSTRUCTION MANUAL CS1 15 Barometric Pressure Sensor 3/03 Copyright (c) 2002-2003 Campbell Scientific, Inc. ...

  • Campbell Hausfeld CS115 - page 2

    Warranty and Assistance The CS115 BAROMETR IC PRESS URE SE NSOR is w arranted by CAMPBELL SCIENTIFIC, INC. to be f ree from def ects in m aterials and workmanship und er no rmal use a nd ser vice fo r twelve ( 12 ) months fr om date of shipment unle ss spec ified othe rwise. B atte ries ha ve no warr anty. CAMP BE LL SCIENTIFIC, INC.' s obliga ...

  • Campbell Hausfeld CS115 - page 3

    i CS115 Table of Contents PDF viewers note: These page numbers refer to the printed version of this document. Use the Adobe Acrobat® bookmarks tab for links to specific sections. 1. Introducti on ................................................................. 1 2. Specifications ............................................................. 2 2.1 ...

  • Campbell Hausfeld CS115 - page 4

    This is a blank page. ...

  • Campbell Hausfeld CS115 - page 5

    1 CS115 Barometric Pressure Sensor The CS115 Barometric Pressure Sensor us es the resonant silicon technology pressure sensor developed by Druck. The sensor outputs a variable frequency which can be measured using the datalogger' s period averaging instruction or pulse count instruction. The entire process is essentially digital from sensor el ...

  • Campbell Hausfeld CS115 - page 6

    CS115 Barometric Pr essure Sensor 2 2. Specifications 2.1 Performance Measurem ent R ange: 600 mb t o 1100 mb (hPa) Operating Tem perature Range: -40°C to +60°C Hum idity Ran ge: non- condens ing Media Compatibility: non-corrosive gas Total Accuracy 1 : at 20°C ±0.3 mb -10°C to +50°C ±0.5 mb -20°C to +60°C ±1.5 mb -40°C to +60°C ±2.0 m ...

  • Campbell Hausfeld CS115 - page 7

    CS115 Barometric Pr essure Sensor 3 3. Installation 3.1 Venting and Condensati on To p revent condensation, install the se nsor in an en vironm entally protected enclosure, com plete w ith desiccant w hich should be chan ged at regular intervals. A s the sen sor mus t detect the external am bient pressu re the enclosu re mus t not be ‘hermeticall ...

  • Campbell Hausfeld CS115 - page 8

    CS115 Barometric Pr essure Sensor 4 As y ou m ount the sen sor onto the back plate of the enclosu re, place the fork lu g under the m ountin g screw to accomplish the proper groun ding of the s ensor as show n i n Fig ure 3-1. 3.3 Jumper Settings The CS115 ha s tw o operating m odes, ‘ contin uous’ and ‘tri ggered’ . It is norm ally shipped ...

  • Campbell Hausfeld CS115 - page 9

    CS115 Barometric Pr essure Sensor 5 4. Wiring The CS115 w iring instru ctions f or the exam ple program s are sh own in Table 4-1. For datal oggers C R500, CR510, C R10(X), CR 23X, and CR5000, analog ch annel is us ed for period averagin g meas uremen t. For CR7, 21X and CR9000 pu lse chann el is us ed for pulse cou nt m easurem ent. TABLE 4-1. Wir ...

  • Campbell Hausfeld CS115 - page 10

    CS115 Barometric Pr essure Sensor 6 Once th e CS115 is tu rned on one m inu te before every hour, an d the correct measu rement is m ade, it is then copied into the current variable called "Pressure" . The sensor is then turned off im m ediately follow ing the meas uremen t. In thi s exam ple, the CR 5000 measu res the CS 115 once every h ...

  • Campbell Hausfeld CS115 - page 11

    CS115 Barometric Pr essure Sensor 7 5.1 Period Averaging Measurement Examples 5.1.1 Period Averaging Measurement Example fo r CR10(X) EXAMPLE 1. Sam ple Program for CR 10(X) ;{CR 10X} ; *Table 1 Prog ram 01: 1 Execution Interval (seconds ) ;Turn on C S115 one m inut e before the h our ; 1: If tim e is (P92) 1: 59 Minutes (Seconds --) in to a 2: 60 ...

  • Campbell Hausfeld CS115 - page 12

    CS115 Barometric Pr essure Sensor 8 8: Sam ple (P70) 1: 1 Reps 2: 1* Loc [ P_m b ] *Table 2 Prog ram 02: 0.0000 Execution In terval (secon ds) *Table 3 S ubroutin es End Program -Input Loca tio ns- 1 P_m b * Proper entries w ill vary w ith program an d datalogger channel, and input location assign ments. 5.1.2 Period Averaging Measurement Example f ...

  • Campbell Hausfeld CS115 - page 13

    CS115 Barometric Pr essure Sensor 9 ;T urn off CS1 15 ; 4: Do (P86) 1: 58* Set Port 8* Low 5: If tim e is (P92) 1: 0 Minutes (Secon ds --) in to a 2: 60 Interval (sam e un its as above) 3: 1 0 Set Out put Flag H igh (Flag 0 ) 6: Real Tim e (P77) 1: 0110 Day ,Hour/Mi nute (m idnig ht = 0000) 7: Sam ple (P70) 1: 1 Reps 2: 1* Loc [ P_m b ] *Table 2 Pr ...

  • Campbell Hausfeld CS115 - page 14

    CS115 Barometric Pr essure Sensor 10 3: Period A verage (SE) (P27) 1: 1 Reps 2: 14 200 kHz Max Freq @ 500 m V Peak to Peak, F req Output 3: 24* SE Chan nel 4: 10 No. of Cy cles 5: 5 Timeou t (unit s = 0.01 seconds) 6: 1* Loc [ P_m b ] 7: 1000 Mult 8: 0.0 Of fset ;T urn off CS1 15 ; 4: Do (P86) 1: 51* Set Port 1* Low 5: End (P95) 6: If tim e is (P92 ...

  • Campbell Hausfeld CS115 - page 15

    CS115 Barometric Pr essure Sensor 11 5.1.4 Period Averaging Measurement Example fo r CR5000 in a Fast Executing Program at 10Hz EXAMPLE 4. Sam pl e Program for C R5000 ‘CR5000 ' 'Sample Progr am to Measure C S115 Barometri c Pressur e Sensor ' ' Public CS115_Freq, Pressu re Units Pressure = mb Begi nPr og Scan (100,m Sec,3,0) ...

  • Campbell Hausfeld CS115 - page 16

    CS115 Barometric Pr essure Sensor 12 5.2 Pulse Count Measure ment Exampl e 5.2.1 Pulse Count Measu rement Example for 21X EXAMPLE 5. Sam ple Program for 21X ;{21X} ; *Table 1 Prog ram 01: 1 Execution Interval (seconds ) 1: If tim e is (P92) 1: 59 Minu tes into a 2: 60 Minu te Interval 3: 46* Set Port 6* Hig h 2: If tim e is (P92) 1: 0 Minutes into ...

  • Campbell Hausfeld CS115 - page 17

    CS115 Barometric Pr essure Sensor 13 *Table 3 S ubroutin es End Program -Input Loca tio ns- 1 P_mb 1 1 1 * Proper entries w ill vary w ith program an d datalogger channel, and input location assign ments. 5.3 Output Resolution When s toring th e valu es from the CS115 t o a datalogger’ s fin al storage location, or to a da ta table, care must be ...

  • Campbell Hausfeld CS115 - page 18

    CS115 Barometric Pr essure Sensor 14 The corrections in volved can be signi ficant: e.g ., at 1000 mb an d 20°C, barometric pressure w ill decrease by 1.1 mb for ev ery 10 meter in crease in altitude. 7. Maintenance and Calibration Since the sen sor is sem i-sealed, m inim um m aintenan ce is required. 1. Visually inspect the cable conn ectio n to ...

  • Campbell Hausfeld CS115 - page 19

    Thi s is a b lank p age . ...

  • Campbell Hausfeld CS115 - page 20

    Campbell Scie ntific Com panies Campbell Scientific, Inc. (CS I) 815 West 1 800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com info@campb ellsci.com Campbell Scientif ic Africa Pty. Ltd. (CSAf) PO B ox 24 50 Somers et West 7129 SOUTH AFRICA www.csafrica.co.za sales@csafrica.co.za Campbell Scientific Au st ralia Pt y. Ltd. (CSA) PO B ox 4 ...

メーカー Campbell Hausfeld カテゴリー Marine Instruments

Campbell Hausfeld CS115のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- CS115の取扱説明書
- Campbell Hausfeldの製品カード
- パンフレット
- またはCampbell Hausfeld CS115の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Campbell Hausfeld CS115の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Campbell Hausfeld CS115の取り付け説明書、サービスマニュアル、簡易説明書、またはCampbell Hausfeld CS115のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Campbell Hausfeld CS115の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Campbell Hausfeld CS115デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがCampbell Hausfeld CS115を使用するのを助ける技術的文書のことです。説明書は通常、全てのCampbell Hausfeld CS115ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Campbell Hausfeldの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Campbell Hausfeld CS115の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははCampbell Hausfeld CS115の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Campbell Hausfeld CS115に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Campbell Hausfeld CS115デバイスの基本機能を使うにあたってのヒント。 Campbell Hausfeld CS115のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Campbell Hausfeld CS115に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるCampbell Hausfeld CS115のメーカー/サービスへの連絡先に関する情報。

Campbell Hausfeld CS115についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもCampbell Hausfeld CS115の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがCampbell Hausfeld CS115で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)