    OPERA TING & SER VICE MANUAL BUNN-O-MA TIC CORPORA TION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS 62708-3227 PHONE: (217) 529-6601 F AX: (217) 529-6644 39064.0000A 04/06 ©2006 Bunn-O-Matic Corporation www .bunn.com VPR TC VPR APS ...

  • Bunn VPR APS - page 2

    Page 2 INTRODUCTION This equipment will brew a half-gallon batch of coffee into an awaiting dispenser . It is only for indoor use on a sturdy counter or shelf. WARRANTY Bunn-O-Matic Corp. (“Bunn”) warrants the equipment manufactured by it to be commer cially free from de- fects in material and workmanship existing at the time of manufacture and ...

  • Bunn VPR APS - page 3

    Page 3 USER NOTICES Carefully read and follow all notices in this manual and on the equipment. All labels on the equipment should be kept in good condition. Replace any unreadable or damaged labels. #00833.0000 #00658.0000 #00831.0000 ...

  • Bunn VPR APS - page 4

    Page 4 ELECTRICAL REQUIREMENTS CAUTION - The brewer must be disconnected from the power sour ce until specifi ed in Initial Set-Up. The brewer has an attached cordset and requires 2-wire grounded service rated 120 volts ac, 15 amp, single phase, 60 Hz. INITIAL SET -UP CAUTION - The brewer must be disconnected from the power sour ce throughout the ...

  • Bunn VPR APS - page 5

    Page 5 TROUBLESHOOTING A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic T echnical Ser vice Department. • Inspection, testing, and repair of electrical equipment should be performed only ...

  • Bunn VPR APS - page 6

    Page 6 TROUBLESHOOTING (cont.) PROBLEM Dripping from sprayhead Beverage overfl ows dispenser Weak beverage PROBABLE CAUSE REMEDY 1. Lime Build-up CAUTION - T ank and tank com- ponents should be delimed regularly depending on local water conditions. Excessive min- eral build-up on stainless steel surfaces can initiate corrosive reactions resulting ...

  • Bunn VPR APS - page 7

    Page 7 TROUBLESHOOTING (cont.) PROBLEM Dry coffee grounds remain in the funnel Brewer is making unusal noises PROBABLE CAUSE REMEDY 1. Funnel Loading 1. T ank Heater The BUNN ® paper fi lter must be centered in the funnel and the bed of grounds leveled by gently shaking. Remove and clean lime off the tank heater . See page 10 39064 042806 ...

  • Bunn VPR APS - page 8

    Page 8 FIG. 3 CONTROL THERMOST A T CONTROL THERMOST A T SERVICE This section provides procedures for testing and replacing various major components used in this brewer should service become necessar y . Refer to T roubleshooting for assistance in determining the cause of any problem. WARNING - Inspection, testing, and repair of electri- cal equipme ...

  • Bunn VPR APS - page 9

    Page 9 Location: The control thermostat is located inside the hood on the left end of the mounting bracket. T est Procedures: 1. Disconnect the brewer from the power sour ce. 2. Locate the black wire on the control thermo- stat. 3. Check voltage across the black wire on the control thermostat and the white wire on the tank heater with a voltmeter . ...

  • Bunn VPR APS - page 10

    Page 10 FIG. 6 LIMIT THERMOST A T TERMINALS SERVICE (cont.) LIMIT THERMOST A T Location: The limit thermostat is located inside the hood on the right side of the tank lid. T est Procedures: 1. Disconnect the brewer from the power source. 2. Disconnect the blue/black and black wires from the limit thermostat. 3. Check for continuity across the limit ...

  • Bunn VPR APS - page 11

    Page 11 SERVICE (cont.) If continuity is present as described, reconnect the wires, the tank heater is operating properly . If continuity is not present as described, replace the tank heater . NOTE- If the tank heater remains unable to heat, remove and inspect heater for cracks in the sheath. Removal and Replacement: 1. Remove the tank inlet fi tt ...

  • Bunn VPR APS - page 12

    Page 12 L1 BLK T ANK HEA TER WHI LOWER WARMER "KEEP WARM" HEA TER WHI BLK SCHEMA TIC WIRING DIAGRAM VPR, VPR TC & VPR APS GREEN N WHI WHI BLK 33769.0000C 03/06 © 2001 BUNN - O - MA TIC CORPORA TION UPPER WARMER WHI BLK 120 VOL TS A C 2 WIRE SINGLE PHASE 60 HZ WHI/RED VIO LIMIT THERMOST A T BLU/BLK SW . & THERMOST AT ON/OFF SWITCH ...

メーカー Bunn カテゴリー Coffeemaker

Bunn VPR APSのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- VPR APSの取扱説明書
- Bunnの製品カード
- パンフレット
- またはBunn VPR APSの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Bunn VPR APSの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Bunn VPR APSの取り付け説明書、サービスマニュアル、簡易説明書、またはBunn VPR APSのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Bunn VPR APSの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Bunn VPR APSデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがBunn VPR APSを使用するのを助ける技術的文書のことです。説明書は通常、全てのBunn VPR APSユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Bunnの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Bunn VPR APSの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははBunn VPR APSの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Bunn VPR APSに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Bunn VPR APSデバイスの基本機能を使うにあたってのヒント。 Bunn VPR APSのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Bunn VPR APSに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるBunn VPR APSのメーカー/サービスへの連絡先に関する情報。

Bunn VPR APSについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもBunn VPR APSの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがBunn VPR APSで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)