  • Bunn 40410.0000G - page 1

    Smar t W ave Series Smar t W ave Silver Series Series ® INST ALLA TION & OPERA TING GUIDE BUNN-O-MA TIC CORPORA TION POST OFFICE BO X 3227 SPRINGFIELD , ILLINOIS 62708-3227 PHONE: (217) 529-6601 F AX: (217) 529-6644 T o ensure you have the latest revision of the Operating Manual, or to view the Illustrated Parts Catalog, Programming Manual, or ...

  • Bunn 40410.0000G - page 2

    Page 2 40410 030912 BUNN-O-MA TIC COMMERCIAL PRODUCT WARRANTY Bunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows: 1) Airpots, thermal carafes, decanters, GPR servers, iced tea/coffee dispensers, MCP/MCA pod brewers thermal ser vers and Thermofresh servers (mechanical and digital)- 1 year parts and 1 year labor . 2) All ...

  • Bunn 40410.0000G - page 3

    Page 3 CONTENTS Warranty .............................................................................................................2 Introduction ........................................................................................................3 User Notices .................................................................................. ...

  • Bunn 40410.0000G - page 4

    Page 4 ELECTRICAL REQUIREMENTS CAUTION - The brewer must be disconnected from the power source until specified in Initial Set-Up. Refer to Data Plate on the Brewer , and local/national electrical codes to determine circuit requirements. Electrical Hook-Up CAUTION – Improper electrical installation will damage electronic components. 1. An electri ...

  • Bunn 40410.0000G - page 5

    Page 5 PLUMBING REQUIREMENTS These brewers must be connected to a cold water system with operating pressure between 20 and 90 psi (138 and 620 kPa) from a 1 ⁄ 2 " or larger supply line. A shut-off valve should be installed in the line before the brewer . Install a regulator in the line when pressure is greater than 90 psi (620 kPa) to reduce ...

  • Bunn 40410.0000G - page 6

    Page 6 INITIAL SET UP CAUTION - The brewer must be disconnected from the power source throughout the initial set-up, except when specified in the instructions. 1. Insert an empty funnel into the funnel rails. (FIG 4) 2. Place an empty server under the funnel. For taller ser vers, lift up on the front of the booster plate, and slide it back into th ...

  • Bunn 40410.0000G - page 7

    Page 7 COFFEE BREWING 1. Begin each brew cycle with a clean empty brew funnel. 2. Insert a BUNN filter into the funnel. (FIG 6) 3. Pour (or grind) fresh coffee into the filter and level the bed of grounds by gently shaking. 4. Slide the funnel into the funnel rails until it stops. 5. Place an empty server under the funnel. 6. Verify that the &quo ...

  • Bunn 40410.0000G - page 8

    Page 8 OPERA TING CONTROLS - SIL VER SERIES (A) ENABLE BREW ON/OFF SWITCH Pressing the "ENABLE BREW ON/OFF" switch (indicator on) enables the brew circuit, and energizes the tank refill circuit. Pressing the switch again (indicator off) stops tank refilling and brewing. Stopping a brew cycle after it has been started will not stop the ? ...

  • Bunn 40410.0000G - page 9

    Page 9 40410 092407 PROGRAMMING - SIL VER SERIES BREW VOLUME SET -UP: NOTE: Set small and large batches separately . Maximum water on time is 5 minutes. Use the following steps when the setting is unknown. 1. Place an empty funnel in the funnel rails and an empty server beneath the funnel. 2. Press the "ENABLE BREW ON/OFF" switch ("O ...

  • Bunn 40410.0000G - page 10

    Page 10 B C A (A) ENABLE BREW ON/OFF SWITCH Pressing the "ENABLE BREW ON/OFF" switch (indicator/display on) enables the brew circuit, and the tank refill circuit. Pressing the switch again (indicator/display off) stops tank refilling and brewing. Stopping a brew cycle after it has been started will not stop the flow of water into the s ...

  • Bunn 40410.0000G - page 11

    Page 11 40410 092211 PROGRAMMING - SMAR T W A VE WITH DISPLA Y BREW VOLUME SET -UP: NOTE: Maximum water on time is 5 minutes. 1. Press the "HIDDEN" switch until display reads A1. This represents the adjust mode "Brew Time" for the "A" brew switch. The display will then change to (minutes-seconds). Press "BREW A&qu ...

  • Bunn 40410.0000G - page 12

    Page 12 Remove sprayhead by turning counterclockwise DELIMING Bunn-O-Matic recommends deliming your coffee brewer periodically . The actual frequency of deliming de- pends on the mineral content of the water you use. NOTE: In hard water areas, this may need to be done daily . It will help prevent liming problems in the brewer and takes less than a ...

  • Bunn 40410.0000G - page 13

    Page 13 FIG 12 FIG 11 CLEANING The use of a damp cloth rinsed in any mild, non-abrasive, liquid detergent is recommended for cleaning all surfaces on Bunn-O-Matic equipment. CLEANING OPTIONAL LARGE SPRA YHEAD 1. Remove the brew funnel. 2. Remove the sprayhead by turning it counterclockwise with your fingertips. 3. Disassemble sprayhead by removing ...

  • Bunn 40410.0000G - page 14

    Page 14 CO VER REMO V AL Unplug the brewer and let it cool down before proceeding. Front Wrap: 1. Remove the brew funnel. 2. Remove upper and lower screws on either side of front cover . 3. Loosen middle screw on either side of front cover . 4. Pull front cover towards front of brewer . T op Cover: 1. Remove both screws. 2. Lift top cover to clear ...

  • Bunn 40410.0000G - page 15

    Page 15 DRAINING T ANK 1. Unplug the brewer and let it cool down before proceeding. 2. Remove the brew funnel. 3. Remove the front cover . 4. Pinch fill hose. 5. Loosen clamp from fill solenoid.. 6. Remove hose from solenoid and drain into sink as shown (or 2 gallon bucket). 7. After draining, reinstall hose and clamp. (Hand tighten only) . FIG 1 ...

  • Bunn 40410.0000G - page 16

    Page 16 1 2 3 4 OFF ON FIG 16 SWITCH SETTINGS Program Switches: 1. Unplug the brewer and let it cool down before proceeding. 3. Remove the left rear cover . 4. Flip the dip switches as needed. NOTE: All switches are turned OFF from factory . FIG 15 KEY # FUNCTION - OFF FUNCTION - ON 4. High altitude Set temp 200°F (93°C) Set temp 190°F (87.8°C) ...

  • Bunn 40410.0000G - page 17

    Page 17 TR OUBLESHOO TING 40410 092407 RED LED FLASHES DISPLA Y DESCRIPTION ACTION 1. ER 1 TEMP SENSOR SHORTED CALL SERVICE 2. ER 2 TEMP SENSOR OPEN CALL SERVICE 3. ER 3 HEA TING TOO LONG CALL SERVICE 4. ER 4 REFILL TOO LONG CHECK WA TER SUPPL Y 5. ER 5 HIGH T ANK LEVEL-DURING BREW DELIME 6. ER 6 CHECK "ENABLE BREW ON/OFF" SWITCH CHECK SW ...

  • Bunn 40410.0000G - page 18

    Page 18 - SCHEMA TIC WIRING DIAGRAM W A VE 15 APS, 15 S APS 40405.0001A 02/08 ©2008 BUNN-O-MA TIC CORPORA TION T ANK HEA TER LIMIT THERMOST A T VENT V AL VE SOLENOID 12VDC L1 NT BLU/BLK BLK-14 230V AC 2 WIRE + GND SINGLE PHASE RED/BLK WHI WHI BLU BRN J2-1 J5-1 BRN - ON/0 OFF ORN +12 ORN GRN TA N WHI/ORN +12 WHI PNK RED/BLK - ON/0 OFF GRN YEL WHI/R ...

  • Bunn 40410.0000G - page 19

    Page 19 SCHEMA TIC WIRING DIAGRAM W A VE 120/240V APS SERIES 40405.0002A 02/08 ©2008 BUNN-O-MA TIC CORPORA TION 120/240V AC 3 WIRE + GND SINGLE PHASE Chassis Ground Earth Ground GRN/YEL - T ANK HEA TER LIMIT THERMOST A T VENT V AL VE SOLENOID 12VDC L1 NT BLK BLK-14 RED/BLK RED WHI WHI BLK J2-1 J5-1 BRN - ON/0 OFF ORN +12 ORN GRN TA N WHI/ORN +12 W ...

  • Bunn 40410.0000G - page 20

    Page 20 - SCHEMA TIC WIRING DIAGRAM WA VE 15 APS, 15 S APS 40405.0003A 04/10 ©2010 BUNN-O-MA TIC CORPORATION T ANK HEATER LIMIT THERMOS TAT VENT VA LVE SOLENOID 12VDC L1 NT C O N T R O L P C B O A R D BLK BLK-14 100/120V AC 2 WIRE + GND SINGLE PHASE RED/BLK WHI WHI WHI BLK J2-1 J5-1 BRN - ON/0 OFF ORN +12 ORN GRN TA N WHI/ORN +12 BLK PNK RED/BLK - ...

メーカー Bunn カテゴリー Coffeemaker

Bunn 40410.0000Gのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 40410.0000Gの取扱説明書
- Bunnの製品カード
- パンフレット
- またはBunn 40410.0000Gの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Bunn 40410.0000Gの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Bunn 40410.0000Gの取り付け説明書、サービスマニュアル、簡易説明書、またはBunn 40410.0000Gのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Bunn 40410.0000Gの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Bunn 40410.0000Gデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがBunn 40410.0000Gを使用するのを助ける技術的文書のことです。説明書は通常、全てのBunn 40410.0000Gユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Bunnの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Bunn 40410.0000Gの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははBunn 40410.0000Gの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Bunn 40410.0000Gに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Bunn 40410.0000Gデバイスの基本機能を使うにあたってのヒント。 Bunn 40410.0000Gのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Bunn 40410.0000Gに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるBunn 40410.0000Gのメーカー/サービスへの連絡先に関する情報。

Bunn 40410.0000Gについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもBunn 40410.0000Gの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがBunn 40410.0000Gで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)