  • Amana AMH* - page 1

    C US ® RT6621017r1 April 2010 This manual is to be used by qualified, professionally trained HV AC technicians only . Goodman does not assume any responsibility for property damage or personal injury due to improper service procedures or services performed by an unqualified person. ® is a registered trademark of Maytag Corporation or its related ...

  • Amana AMH* - page 2

    PRODUCT IDENTIFICA TION 2 The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. WARNING WARNING HIGH VOLTAGE! Disconnect ALL power before servicing or installing this unit. Multiple power sources may be present. Failure ...

  • Amana AMH* - page 3

    PRODUCT IDENTIFICA TION 3 The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. * Indicates minor revision & is not used for order entry or inventory management AMH80453AXC* AMH80703AXC* AMH80704BXC* AMH80903BXC* AM ...

  • Amana AMH* - page 4

    4 PRODUCT DESIGN WA R N I N G T O PREVENT P OSSI BLE PERSONAL I NJURY OR DEATH DUE TO ASPHYX I ATI ON, THI S FURNACE M UST BE C AT E GOR Y I VENT ED. D O NOT VENT USI NG C ATEGORY III VEN TI NG. 1. Category I Venting is venting at a non-positive pressure. A furnace vented as Category I is considered a fan-as- sisted appliance and the vent system do ...

  • Amana AMH* - page 5

    5 PRODUCT DESIGN Accessibility Clearances (Minimum) Unobstructed front clearance of 24" for servicing is rec- ommended. SW B 1 0 36 11 * 24" clear ance f or s erviceab ility recom me nded. MINIM UM CLEARA NCE TO COMBUSTIBLE MATERIAL S - INCHES ** Si ngle Wall Vent (SW ) to be us ed only as a con ncetor. Refer to the venting ta bles outl i ...

  • Amana AMH* - page 6

    COMPONENT IDENTIFICA TION 6 躀 Pressure Switch T ubul ar Heat E xchanger Flu e Pi pe C onnec ti o n Gas L i ne Entrance (Al tern at e) Indu ced Draf t Blowe r Gas Line En tr a nc e Gas V alve Roll o ut Li mit Junc tion Box Wiri ng Har nes s Grommet Gas Ma nif old Inshot Burne r Blower Door Interlock Switch Integrated Contr ol Module T rans for mer ...

  • Amana AMH* - page 7

    PRODUCT DIMENSIONS 7 AMH8 MO D EL S A B AMH 8 0 4 5 3 AX** AMH 8 0 7 0 3 AX** 14 1 2 - 1/ 2 AMH 8 0 7 0 4 BX** AMH 8 0 9 0 3 BX** AMH 8 0 9 0 4 BX** 17-1 / 2 16 A MH8 09 05C X * * A MH8 11 55C X * * 21 1 9 - 1/ 2 A MH8 140 5D X * * 24- 1 /2 23 A ll d i m e ns i o ns ar e i n in c h es . Alt. Ga s I nlet Hi gh Voltage In let Lo w V olt ag e Alt. Ga ...

  • Amana AMH* - page 8

    8 PRODUCT DESIGN MODEL TRIP POINT ID BLOWER PRESSURE SWITCH ID BLOWER PRESSURE SWITCH PART # MODEL TRIP POINT ID BLOWER PRESSURE SWITCH ID BLOWER PRESSURE SWITCH PART # AMH80453A X** -0.60 B1370142 AMH80453A X** -0.60 B1370142 AMH80703A X** -0.60 B1370142 AMH80703A X** -0.60 B1370142 AMH80704BX* * -0.60 B1370142 AMH80704BX** -0.47 B1370176 AMH80903 ...

  • Amana AMH* - page 9

    9 PRODUCT DESIGN Coil Matches: A large array of Amana ® brand coils are available for use with the AMH8 furnaces, in either upflow or horizontal applica- tions. These coils are available in both cased and uncased models (with the option of a field installed TXV expansion device). These 80% furnaces match up with the existing Amana ® brand coils a ...

  • Amana AMH* - page 10

    10 PRODUCT DESIGN Thermost at s: The following Amana ® brand Thermostats are suggested for use with the AMH8 Furnace Models: Filters: Filters are required with this furnace and must be provided by the installer. The filters used must comply with UL900 or CAN/ULCS111 standards. Installing this furnace without filters will void the unit warranty. Re ...

  • Amana AMH* - page 11

    11 PRODUCT DESIGN T winComfort™ Configuration & Operation OFF ON Blower Switch to Hi Heat Operation Blower Switch to Hi Heat Operation T-Stat S atisfied T-Stat S atisfied Delay Time ( 5 Min) Delay Time 1- 12 Min) Gas Valv e Swit ch to 2nd Stage Gas Valv e Swit ch to 2nd Stage Start Furnac e in Low Stage Start Furnac e in Low Stage Low-Heat Bl ...

  • Amana AMH* - page 12

    FURNACE SPECIFICA TIONS 12 NOTES: 1. For elevations above 2000 feet the rating should be reduced by 4% for each 1000 feet above sea level. The furnace must not be derated, orifice changes should only be made if necessary for altitude. 2. The total heat loss from the structure as expressed in TOTAL BTU/HR must be calculated by the manufacturers meth ...

  • Amana AMH* - page 13

    BLOWER PERFORMANCE SPECIFICA TIONS 13 NOTES: 1 . CFM in chart is without filters(s). Filters do not ship with this furnace, but must be provided by the installer. 2 . All furnaces ship as high speed cooling. Installer must adjust blower cooling speed as needed. 3 . For most jobs, about 400 CFM per ton when cooling is desirable. 4 . INSTALLATION IS ...

  • Amana AMH* - page 14

    BLOWER PERFORMANCE SPECIFICA TIONS 14 30 40 50 60 70 80 90 1 10 12 0 100 13 0 140 150 100 90 80 70 60 50 40 30 20 10 OU TPUT B T U/HR x 10 00 BTU OUTPUT vs T EMPERA TURE RISE CHART TE M PE R AT U R E R ISE 600 CFM 700 900 100 0 1 100 1200 1400 1600 180 0 2000 2200 2400 CFM FORM ULA S BTU OUTPUT = C FM x 1.08 x RISE RISE = BTU OUTPUT 1.08 ÷ CFM 800 ...

  • Amana AMH* - page 15

    15 WIRING DIAGRAMS Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. HIGH VOL T A GE! DISCONNECT ALL POWER BEFORE SERVICI NG OR INST A LLING THIS UNIT . M UL TIPL E POW ER SOUR CES MA Y BE P RESENT . F AILURE TO DO SO MA Y CAUSE PROP ERTY DAMAG E, PERSO NAL INJURY OR DEA TH . AMH8_CA/CB CAP ...

  • Amana AMH* - page 16

    16 WIRING DIAGRAMS Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. HIGH VOL T A GE! DISCONNECT ALL POWER BEFORE SERVICI NG OR INST A LLING THIS UNIT . M UL TIPL E POW ER SOUR CES MA Y BE P RESENT . F AILURE TO DO SO MA Y CAUS E PROPERTY DAMAG E, PERSONAL I NJUR Y OR DEA TH. CA P BK (H I) A ...

  • Amana AMH* - page 17

    17 SCHEMA TICS HI G H VO L T AG E! DISC ONNECT ALL POWER BEFORE SERVICI NG OR INST A LLIN G THIS UNIT . M UL TIPL E POW ER SOURCES M A Y BE PR ESENT . F AILURE T O DO SO MA Y CAUS E PROPERTY DAMAG E, PERSONAL I NJUR Y OR DEA TH . TYPICAL SCHEMATIC AMH8 ____** MODEL FURNACES WR 50M56-289 INTEGRATED IGNITION CONTROL .00 05 3M K4 K2 HI HEAT COOL PARK ...

メーカー Amana カテゴリー Furnace

Amana AMH*のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- AMH*の取扱説明書
- Amanaの製品カード
- パンフレット
- またはAmana AMH*の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Amana AMH*の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Amana AMH*の取り付け説明書、サービスマニュアル、簡易説明書、またはAmana AMH*のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Amana AMH*の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Amana AMH*デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがAmana AMH*を使用するのを助ける技術的文書のことです。説明書は通常、全てのAmana AMH*ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Amanaの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Amana AMH*の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははAmana AMH*の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Amana AMH*に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Amana AMH*デバイスの基本機能を使うにあたってのヒント。 Amana AMH*のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Amana AMH*に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるAmana AMH*のメーカー/サービスへの連絡先に関する情報。

Amana AMH*についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもAmana AMH*の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがAmana AMH*で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)