  • Bosch 125B LP - page 1

    W ARNING : Improper installat ion , adjust ment , alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional informat ion consult a qualified inst aller , service agency or t he gas supplier . Upon completion of the installation, these instructions should be handed to the user of the a ...

  • Bosch 125B LP - page 2

    2 6 720 607 030 This well engineered, gas water heater has all the fea- tures a water heater should have: It operates on the principle of heating water instantaneously “on demand”. When a hot water faucet is opened, cold water flows through the coils of the heat exchanger in the Aquast ar. This same flow opens the gas valve, and the burners are ...

  • Bosch 125B LP - page 3

    3 6 720 607 030 M I N I M U M I N S T ALLA TI O N C LE ARAN C E S F R OM C O M B U S TI B LE A N D N O N C OM B U STI B LE MA TE R IALS F OR AL COVE O R C L O SET I N S T ALLA TIO N S FR ONT VI EW SI D E VI EW A QUAST AR M ODE L 1 25B MODEL 125B TO P ( A) 12 " FR ONT ( B) 4 " BAC K 0 " SIDE S 4 " FLOOR (C) 12 " VENT DIA M E ...

  • Bosch 125B LP - page 4

    4 6 720 607 030 G EN E RAL R ULE S T O FOLL OW FOR SAFE OPE R A TI ON 1. Y ou should follow these instructions when you install your heater . In the United States: The installation must conform with local codes or , in the absence of local codes , the National Fuel Gas Code ANS I Z223. 1 / N FP A 54. In Canada: The Installation should conform with ...

  • Bosch 125B LP - page 5

    5 6 720 607 030 Fig. 1 - Water heater drain plug WARNING: Flammable materials, gasoline, pressurized containers, or any other items or articles that are potent ially fire hazards must NO T be placed on or adjacent t o t he heater . The appliance area must be kept free of all combustible materials, gasoline and other flammable vapors and liquids. CO ...

  • Bosch 125B LP - page 6

    6 6 720 607 030 Expansion and contraction of piping due to changing water temperature in the pipes imparts movement to the heater which, if mounted directly to a brittle, friable board, such as plasterboard, can cause failure of mounting. In earthquake-prone zones, C EC recommends that installers use a large washer and lag screw through the existin ...

  • Bosch 125B LP - page 7

    7 6 720 607 030 V ent pipe connection. WARN I NG: Do not reduce t he vent pipe size. See Fig . 4 for high altitude installat ions The heater must be vented to the outside following all local ordinances and specifications for installing a gas appliance vent or c himney . The heater must be located as close as practicable to a vertically rising c him ...

  • Bosch 125B LP - page 8

    8 6 720 607 030 MASON RY CH IM NE Y : Masonr y c himneys shall be built and installed in accordance with NF PS 2 1 1 or local codes. A minimum 5” diameter gas vent pipe (met al double wall T ype B ), or an approved clay flue liner or a listed chimney lining system must be used when venting into a naturally drafting, internal masonry c himney . 6 ...

  • Bosch 125B LP - page 9

    9 6 720 607 030 T o check t he draft : Close all doors and windows to the outside. T urn on all appliances that force air out of the building . These include all exhaust/ventilation fans, furnaces, clothes dryers, wood burning stoves, etc. Open all doors between the AquaStar and these other appliances. With the control knob set fully clockwise and ...

  • Bosch 125B LP - page 10

    10 6 720 607 030 GAS LINE SIZING -It is strongly recommended that the Natural Gas pipe be Black Iron pipe the entire distance from the outside meter to the inlet of t he Aquast ar regulat or . 1 /2” Black Iron pipe up t o 1 0 feet , 3/ 4 ” Black Iron pipe up to 4 0 feet and 1 ” Black Iron pipe up to 1 50 feet distances. Flex line tubing is NO ...

  • Bosch 125B LP - page 11

    11 6 720 607 030 GAS PIPING, CONNECTIONS and Gas Regulator Before connecting the gas supply, c heck the rating plate on the right side of the front cover to be sure that the heater is rated for the same gas to which it will be connected. In the United St ates: T he installation must conform with local codes or, in the absence of local codes , the N ...

  • Bosch 125B LP - page 12

    12 6 720 607 030 W A TE R CON NECTIONS Install the heater centrally in the building if possible and make hot water piping runs as short as possible When facing the heater , the cold water inlet will be on the right and the hot water outlet on the left.. Although water piping throughout the building may be other than copper , copper or galvanized pi ...

  • Bosch 125B LP - page 13

    13 6 720 607 030 LIGHTING INSTRUCTIONS (as seen on front cover of heater) 1. S T O P! Read the safety information above on this plate. 2. The Gas valve must be turned off by sliding the gas valve button to the far left under the OFF ( ) mark. 3. W ait five (5) minutes to clear out any gas . If you smell gas, S T OP! Follow “B” in the safety inf ...

  • Bosch 125B LP - page 14

    14 6 720 607 030 T o clean t he pilot burner and/ or t he pilot orifice : T urn off the gas at the unit. Remove the cover of the heater . T o do so, pull off the temperature adjustment knob and unscrew and remove the plastic collar and unscrew the central screw located at the bottom of the front cover . Pull main cover out toward you and lift up an ...

  • Bosch 125B LP - page 15

    15 6 720 607 030 3. Poor thermocouple connection at the electromagnet Note : Electromagnet is part #8 7072 0 1 01 2 l ocated on the right side of the gas valve behind the piezo push-button assembly . Check the tightness of the thermocouple connection nut at the electromagnet: The Electro-magnet connection is a large aluminum 1 7mm hex head nut. The ...

  • Bosch 125B LP - page 16

    16 6 720 607 030 5. Crossover in household plumbing The AquaStar burner activates when there is sufficient water pressure drop in the AquaStar water valve assembly — i.e. when a hot water faucet is opened. If there is a crossover in the plumbing, the necessary pressure drop in the AquaStar will be insufficient, or totally eliminated. A plumbing c ...

  • Bosch 125B LP - page 17

    17 6 720 607 030 H O T WA T E R TE M PE RA TU R E F LUCTU A T E S / U N IT DEA C T IV A T ED 1 . Unbalanced pressure in waterlines The added restriction caused by the Aquastar in the hot water system can result in uneven pressures between the cold and the hot. In such cases when mixing cold water at the tap, the lower hot water pressure may be over ...

  • Bosch 125B LP - page 18

    18 6 720 607 030 ...

  • Bosch 125B LP - page 19

    19 6 720 607 030 Fig. 1 2 - Diagram of AquaStar 1 25 B 1 . Heat exchanger 2. Pilot assembly 3. Burner manifold gas pressure test nipple 4. Main gas burner 5. Pilot gas tubing 6. Gas valve 7 . Pressure tap screw location 8. Gas control slide 9. Piezo igniter 1 0 . W ater valve 1 1. T emperature adjustment selector 1 2 . Gas inlet gas pressure test n ...

  • Bosch 125B LP - page 20

    20 6 720 607 030 Fig. 1 3 - I NTER I O R C OMP ON E NTS DIAGRAM AND P ARTS LIST ...

  • Bosch 125B LP - page 21

    21 6 720 607 030 Fig. 1 3 INTERIOR COMPONENTS DIAGRAM AN D P ARTS LIST 1 25B 1 Cover 8 705 421 025 2 Temperatu re adjustment knob 8 702 000 111 3T e m p era tur e ad j ustment co l la r 8 700 403 008 4 Dra ft diverter 8 705 505 354 5 Heat e xchange r 8 705 406 235 6 Outlet flex hose 8 700 703 130 7 Wa sher 8 700 103 658 8 Cold water pipe 8 700 705 ...

  • Bosch 125B LP - page 22

    22 6 720 607 030 LI M ITE D W AR R ANT Y Aquast ar 06.03 General Aquastar water heaters are warranted by the Manufacturer (B O SC H) through C ontrolled Energy C orp. C ontrolled Energy Corp . ( C EC ) will furnish a replacement heat exchanger and will furnish a replacement of any other part which fails in normal use and service within the applicab ...

  • Bosch 125B LP - page 23

    23 6 720 607 030 Fig. 1 4 - Flow chart of Aquastar 1 25 B ...

  • Bosch 125B LP - page 24

    Replacement Parts available from North American Distributor CONTROLLED ENERGY CORP . 340 Mad River Park W ait sfield, V ermont 05673 Phone 800-642-31 1 1 Fax (802) 496-6924 ww w .controlledenergy .com/tech techsupport@controlledenergy .com Recycled paper 4 1 & 3 1 s e g a p e e s E L B A T E C N A N E T N I A M R A E Y Y R E V ES R A E Y 2 Y R ...

メーカー Bosch カテゴリー Water Heater

Bosch 125B LPのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 125B LPの取扱説明書
- Boschの製品カード
- パンフレット
- またはBosch 125B LPの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Bosch 125B LPの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Bosch 125B LPの取り付け説明書、サービスマニュアル、簡易説明書、またはBosch 125B LPのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Bosch 125B LPの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Bosch 125B LPデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがBosch 125B LPを使用するのを助ける技術的文書のことです。説明書は通常、全てのBosch 125B LPユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Boschの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Bosch 125B LPの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははBosch 125B LPの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Bosch 125B LPに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Bosch 125B LPデバイスの基本機能を使うにあたってのヒント。 Bosch 125B LPのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Bosch 125B LPに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるBosch 125B LPのメーカー/サービスへの連絡先に関する情報。

Bosch 125B LPについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもBosch 125B LPの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがBosch 125B LPで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)