  • Allied Telesis AT-PWR05 - page 1

    Installation Guide Remo vable P o w er Supply and F an A T -PWR01 A T -PWR02 A T -PWR05 A T -F AN01 A T -F AN03 ...

  • Allied Telesis AT-PWR05 - page 2

    Remo vable P o wer Suppl y and F an Installation Guide AT - P W R 0 1 AT - P W R 0 2 AT - P W R 0 5 AT - F A N 0 1 AT - F A N 0 3 Download the complete document set fr om www .alliedtelesis.com/suppor t/software ...

  • Allied Telesis AT-PWR05 - page 3

    Removable P ow er Supply and Fan 2 Removable P ower Supply and Fan Installatio n Guide Document Number C613-04057-00 REV L © 2008 Allied T elesis, Inc. All rights r eserved. No part of this publication ma y be repr oduced wit hout prior written permissi on fro m Allied T elesis, Inc. Allied T elesis, Inc. reserves the right to change specification ...

  • Allied Telesis AT-PWR05 - page 4

    Installation Guide 3 Contents About this Guide ........................................... ..................... .................... .......................... 4 Compatible Switches .............................................. ..................... .................... ................ 4 Package Contents ........... ..................... ....... ...

  • Allied Telesis AT-PWR05 - page 5

    Removable P ow er Supply and Fan 4 About this Guide This Installation Guide de scribes how to install the f ollowing PSUs and fans: ■ A T -PWR01 PSU , either A C or DC power suppl y unit ■ AT - P W R 0 2 P S U , A C o n l y ■ AT - P W R 0 5 P S U , A C o n l y ■ A T -F AN01, fan-only module ■ A T -F AN03, chassis fan module Compatible Swi ...

  • Allied Telesis AT-PWR05 - page 6

    Installation Guide 5 P acka ge Contents Depending on the model, switches are shipp ed with a single supply unit (PSU), either A C or DC . Some models also ha v e fan-onl y modules (FOM), chassis f an modules, or blanking plates. ■ The A T -8948, A T -9924Ts, x900-24XT , x900-24XT-N, and x900-24XS switches ha ve a PSU and a FOM installed. ■ The ...

  • Allied Telesis AT-PWR05 - page 7

    Removable P ow er Supply and Fan 6 Installing a P o wer Suppl y Unit or F an Use these instructions to install PSUs, chassis fan mo dules and FOMs. ■ Do not combine PWR01 and PWR02 PSUs in the sa me switch. ■ Do not combine A C and DC PSUs in the same switch. Befor e y ou begin ■ Read the safety information f or the switch. Safety inf ormatio ...

  • Allied Telesis AT-PWR05 - page 8

    Installation Guide 7 Installing a PWR01, PWR02, or F AN01 1. If you a re r eplacing a PSU, disconnect the po w er cord fr om the currently installed PSU befor e r emovin g it. For A C PSUs, turn off the main po w er sour ce to the PSU and disc onnect the pow er cord. For DC PSUs, push the Run/Standby contr ol and r elease it to the Off position. Wh ...

  • Allied Telesis AT-PWR05 - page 9

    Removable P ow er Supply and Fan 8 Installing a PWR05 or F AN03 1. If you a re r eplacing a PSU, turn off the main pow er sour ce to th e PSU and disconnect the pow er cor d befor e r emoving it. The DC eart hing connection is not necessar y for the SwitchBlade x908 when using A C PSUs because the ch assis is gr ounded t hr ough the p ow er cor ds. ...

  • Allied Telesis AT-PWR05 - page 10

    Installation Guide 9 Connecting an A C po w er suppl y Follow these instructions to connect an A T-PWR01, A T-PWR02, or A T-PWR05 A C PSU to an A C powe r supply: Wa r n i n g The A T-PWR01 A C PSU has a fuse rating of 2 50 V , 5 A for FH1 01 and FH102. Wa r n i n g The A T-PWR01 A C PSU has double pole/neutral fusing. Electric shock is possible si ...

  • Allied Telesis AT-PWR05 - page 11

    Removable P ow er Supply and Fan 10 3. Connect the po wer cord to the main po we r sour ce. 4. Check that the Run/Standby s witch is set to the Run position (1). Both the A C and DC LEDs should be lit. Note that when the Run/Standby switch is set to the Standby position (0), the A C LED lights and the fan spins, but the DC LED does not light and th ...

  • Allied Telesis AT-PWR05 - page 12

    Installation Guide 11 Connecting a DC po wer suppl y Follow these instructions to connect an A T-PWR01-80 DC PSU to a DC power supply . Only trained and qualified p erso nnel sh ould connect a DC pow er suppl y . Y ou need an appropriate DC po wer sour ce, DC supply cable, ring connectors, a crimp tool and an a ppr opriate scr ewdriver to tighten t ...

  • Allied Telesis AT-PWR05 - page 13

    Removable P ow er Supply and Fan 12 5. Ensure ther e ar e no exposed cable strands. 6. Replace the co ver . Y ou must replace the transparent plastic te rminal cover befor e contin uing. 7. Secur e the supply cabl e to the rack frame w ork or a similar object to ensur e that connections ar e iso lated fro m any f or ce a pplied to the cable. 8. Ens ...

  • Allied Telesis AT-PWR05 - page 14

    Installation Guide 13 Checking LEDs LEDs on PSUs, fans, and the fr ont panels o f switches in dicate the operationa l status of the devices. Aft er you ha ve installed a PSU or fan and ha ve po wer ed on the switch, c heck the LEDs to v erify operation by using the f ollowing tables. PWR01 PWR02 The follo wing table describes LEDs o n the PWR01 and ...

  • Allied Telesis AT-PWR05 - page 15

    Removable P ow er Supply and Fan 14 Switch The follo wing table describes how LEDs on the swi tch re port operations and faults with installed PSUs and FOMs. LED State Description PSU 1 and PSU 2 Green The PSU is installed and supplying po wer to the s witch. The vo ltage output is with in specification. Red One of the f ollowing: • The PSU is in ...

  • Allied Telesis AT-PWR05 - page 16

    Installation Guide 15 Remo ving a P o wer Suppl y Unit or F an Follow these instructions to remo ve a PSU , chassis fan module or FOM. Befor e y ou begin ■ Read the safety information f or the switch. Safety inf ormation is in the x900 Ser ies Switc h and Switc hBlade ® x908 Installation and Safety Guide . Y ou can download th is document fr om ...

  • Allied Telesis AT-PWR05 - page 17

    Removable P ow er Supply and Fan 16 T r oub leshooting If the PSU does not function as expected: ■ Check that all cable connections ar e corr ect and secur e. ■ On the PWR01 DC model, chec k that the Run/Standb y switch h as been presse d and is in the On position. ■ On the PWR05 A C model, check that the Run/Standb y switch has been set to R ...

  • Allied Telesis AT-PWR05 - page 18

    Installation Guide 17 Obtaining Documentation and Resour ces The complete docume nt set for x900 Series switches and SwitchBlade x908 includes: ■ this Installation Guide ■ the x900 Ser ies Switc h and Switc hBlade ® x908 Installation and Saf ety Guide , which describes ho w to install t he switch and includes important safety and statutor y in ...

  • Allied Telesis AT-PWR05 - page 19

    Removable P ow er Supply and Fan 18 A T -TFTP Ser ver for Windows is a TFTP ( T r ivial File T ransfer Pr otocol ) server for transferrin g softwar e v ersions, configurat ion scripts and other files betw een a PC and the switc h. Y ou download A T -TFTP Ser ver fr om www .alliedtelesis.com/support/softwar e . CD-R OM Some pr oducts also ship with ...

  • Allied Telesis AT-PWR05 - page 20

    Installation Guide 19 Standards Pr oducts in this document meet the follo wing standar ds: Category Appro val Agency and Requir ement UL60950-1 CAN/CSA-C22.2 No. 609 50-1-03 EN60950-1 AS/NZS 60950.1 Electr omagnetic Complia nce FCC CFR47 Part 15 Class A EN55022 Class A VCCI Clas s A AS/NZS CISPR22 Class A CNS 13438 Class A EN61000-3-2/ 3 Immunity E ...

  • Allied Telesis AT-PWR05 - page 21

    Removable P ow er Supply and Fan 20 EC Declaration of Conformity We : ALLIED TELESIS LABS LIMITED 27 NAZARETH A VENUE CHRISTCHURCH 802 4 NEW ZEALAND Declare unde r our sole legal responsibil ity that these pro ducts: A T -PWR01, A T -PWR01-80, A T -PWR02, and A T -PWR05 Po w er Supply Units Are in conformity w ith the essential r equir ements o f d ...

メーカー Allied Telesis カテゴリー Power Supply

Allied Telesis AT-PWR05のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- AT-PWR05の取扱説明書
- Allied Telesisの製品カード
- パンフレット
- またはAllied Telesis AT-PWR05の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Allied Telesis AT-PWR05の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Allied Telesis AT-PWR05の取り付け説明書、サービスマニュアル、簡易説明書、またはAllied Telesis AT-PWR05のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Allied Telesis AT-PWR05の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Allied Telesis AT-PWR05デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがAllied Telesis AT-PWR05を使用するのを助ける技術的文書のことです。説明書は通常、全てのAllied Telesis AT-PWR05ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Allied Telesisの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Allied Telesis AT-PWR05の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははAllied Telesis AT-PWR05の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Allied Telesis AT-PWR05に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Allied Telesis AT-PWR05デバイスの基本機能を使うにあたってのヒント。 Allied Telesis AT-PWR05のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Allied Telesis AT-PWR05に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるAllied Telesis AT-PWR05のメーカー/サービスへの連絡先に関する情報。

Allied Telesis AT-PWR05についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもAllied Telesis AT-PWR05の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがAllied Telesis AT-PWR05で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)