APC 78-10169-02の取扱説明書

28ページ 0.22 mb
ダウンロード

ページに移動 of 28

Summary
  • APC 78-10169-02 - page 1

    CHAPTER 2-1 Cisco ICS 7750 Administration and Troubleshooting Guide 78-10169-02 Rev. B0 2 Monitoring the System This chapter explains ho w to monitor the Cisco ICS 7750. The chapter is organized as follo ws: • Alarms, page 2-2 • Logging, page 2-3 • SNMP Basics, page 2-10 • Monitoring with ICS System Manager , page 2-16 • Monitoring with C ...

  • APC 78-10169-02 - page 2

    Chapter 2 Monitoring the System Alarms 2-2 Cisco ICS 7750 Administration and Troubleshooting Guide 78-10169-02 Rev. B0 Alarms This section describes alarms, which indicate problems on the Cisco ICS 7750 or on systems with which it is communicating. Alarms are associated with the following: • Events—Physical problems, such as system o verheating ...

  • APC 78-10169-02 - page 3

    2-3 Cisco ICS 7750 Administration and Troubleshooting Guide 78-10169-02 Rev. B0 Chapter 2 Monitoring the System Logging Alarm Levels The system has the following tw o alarm lev els: • Major alarm (amber LED)—Any state that indicates a system malfunction that can immediately result in a service outage or that indicates a system problem that can ...

  • APC 78-10169-02 - page 4

    Chapter 2 Monitoring the System Logging 2-4 Cisco ICS 7750 Administration and Troubleshooting Guide 78-10169-02 Rev. B0 Handling Log Messages with ICS System Manager ICS System Manager provides se veral options for handling the log messages directed to it. By default, the system sends log messages to the SPE, where they are stored on disk. ICS Syst ...

  • APC 78-10169-02 - page 5

    2-5 Cisco ICS 7750 Administration and Troubleshooting Guide 78-10169-02 Rev. B0 Chapter 2 Monitoring the System Logging T able 2-1 Log Message Elements Element Example Format Description Receiv ed date and time 1999 Nov 21 11:55:00 yyyy mmm dd hh:mm:ss The date and time when the message was recei ved. Sent date and time 1999 Nov 21 11:55:00 yyyy mm ...

  • APC 78-10169-02 - page 6

    Chapter 2 Monitoring the System Logging 2-6 Cisco ICS 7750 Administration and Troubleshooting Guide 78-10169-02 Rev. B0 Facilities T able 2-2 describes the facility types supported by log messages. Severity Levels T able 2-3 describes log message se verity lev els. T able 2-2 Log F acility T ype Ke ywor ds Keyword Description auth Authorization sys ...

  • APC 78-10169-02 - page 7

    2-7 Cisco ICS 7750 Administration and Troubleshooting Guide 78-10169-02 Rev. B0 Chapter 2 Monitoring the System Logging Note Not all messages indicate problems. Some messages are informational. Others may help diagnose problems with communications lines, internal hardware, or system software. T o f ind out how to use system messages to identify and ...

  • APC 78-10169-02 - page 8

    Chapter 2 Monitoring the System Logging 2-8 Cisco ICS 7750 Administration and Troubleshooting Guide 78-10169-02 Rev. B0 Default Log Configuration System IOS components (ASI cards, MRP cards, and the SSP card) ship with the default logging conf iguration shown in T able 2-4 . Ti p T o vie w the state of syslog error and event logging, including host ...

  • APC 78-10169-02 - page 9

    2-9 Cisco ICS 7750 Administration and Troubleshooting Guide 78-10169-02 Rev. B0 Chapter 2 Monitoring the System Logging • syslog path is the path to syslog.conf • myf ile.log is the name of your log f ile The syslog daemon (syslogd) sends messages at the lev el specif ied in syslog.conf, provided that the f ile exists, and provided that syslogd ...

  • APC 78-10169-02 - page 10

    Chapter 2 Monitoring the System SNMP Basics 2-10 Cisco ICS 7750 Administration and Troubleshooting Guide 78-10169-02 Rev. B0 SNMP Basics The Simple Network Management Protocol (SNMP) facilitates the e xchange of management information among network de vices. SNMP is part of the T ransmission Control Protocol/Internet Protocol (TCP/IP) protocol suit ...

  • APC 78-10169-02 - page 11

    2-11 Cisco ICS 7750 Administration and Troubleshooting Guide 78-10169-02 Rev. B0 Chapter 2 Monitoring the System SNMP Basics • An SNMP management application, together with the computer it runs on, is called a network management system (NMS). An NMS executes applications that monitor and control managed devices. NMSs pro vide the bulk of the proc ...

  • APC 78-10169-02 - page 12

    Chapter 2 Monitoring the System SNMP Basics 2-12 Cisco ICS 7750 Administration and Troubleshooting Guide 78-10169-02 Rev. B0 The following system components, though not SNMP-managed de vices, recei ve SNMP support through ICS System Manager: • System alarm processor (SAP) card • Po wer supply modules • Fans • Chassis SNMP Management Informa ...

  • APC 78-10169-02 - page 13

    2-13 Cisco ICS 7750 Administration and Troubleshooting Guide 78-10169-02 Rev. B0 Chapter 2 Monitoring the System SNMP Basics On the Cisco ICS 7750, the ICS System Manager software (the NMS) typically sends SNMP requests to a single IP address to access the SNMP MIBs of any system component. The SNMP agent can then respond to MIB-related queries bei ...

  • APC 78-10169-02 - page 14

    Chapter 2 Monitoring the System SNMP Basics 2-14 Cisco ICS 7750 Administration and Troubleshooting Guide 78-10169-02 Rev. B0 Supported MIBs The Cisco ICS 7750 supports the following MIBs: • CISCO-C2900-MIB—Supports the SSP card. • CISCO-CCM-MIB—Enables the system to get provisioning and statistical information about Cisco CallManager , devi ...

  • APC 78-10169-02 - page 15

    2-15 Cisco ICS 7750 Administration and Troubleshooting Guide 78-10169-02 Rev. B0 Chapter 2 Monitoring the System SNMP Basics Cisco ICS 7750 Traps Cisco ICS 7750 ASI cards, MRP cards, and the SSP card can generate traps such as the following: • coldStart—Indicates power -up reset of a card. • warmStart—Indicates that software running on a ca ...

  • APC 78-10169-02 - page 16

    Chapter 2 Monitoring the System Monitoring with ICS System Manager 2-16 Cisco ICS 7750 Administration and Troubleshooting Guide 78-10169-02 Rev. B0 • Number represents the target physical slot number (slots 1 through 8) of the SNMP request. Note All SNMP requests with a composite community string of @SLO T9 or higher are directed to the SSP, whic ...

  • APC 78-10169-02 - page 17

    2-17 Cisco ICS 7750 Administration and Troubleshooting Guide 78-10169-02 Rev. B0 Chapter 2 Monitoring the System Monitoring with CiscoWorks2000 Monitoring with CiscoWorks2000 CiscoW orks2000 uses SNMP to monitor and control system de vices. Y ou can integrate CiscoW orks2000 applications with other NMSs, such as HP OpenV ie w. CiscoWorks2000 Applic ...

  • APC 78-10169-02 - page 18

    Chapter 2 Monitoring the System Monitoring with Cisco IOS Software 2-18 Cisco ICS 7750 Administration and Troubleshooting Guide 78-10169-02 Rev. B0 SNMP and the CiscoWorks2000 Interface Using SNMP , CiscoW orks2000 retrie ves CDP information by polling Cisco CallManager . After the discovery process is completed, a topology map rev eals all the Cis ...

  • APC 78-10169-02 - page 19

    2-19 Cisco ICS 7750 Administration and Troubleshooting Guide 78-10169-02 Rev. B0 Chapter 2 Monitoring the System Monitoring with Cisco IOS Software Evaluating Reachability and Response Times Polling remote parts of the network enables you to test reachability and measure response times. Response-time measurements consist of sending a ping (packet i ...

  • APC 78-10169-02 - page 20

    Chapter 2 Monitoring the System Monitoring with Cisco IOS Software 2-20 Cisco ICS 7750 Administration and Troubleshooting Guide 78-10169-02 Rev. B0 W ith in-band monitoring, network management data is sent ov er the same paths as user traff ic. This means that any problems on the netw ork will be more diff icult to solve because collecting troubles ...

  • APC 78-10169-02 - page 21

    2-21 Cisco ICS 7750 Administration and Troubleshooting Guide 78-10169-02 Rev. B0 Chapter 2 Monitoring the System Monitoring a UPS Searching and Filtering Output of show Commands In Cisco IOS software Release 12.0(1)T or later , you can search and f ilter the output for show commands. This functionality is useful when you need to sort through large ...

  • APC 78-10169-02 - page 22

    Chapter 2 Monitoring the System Monitoring a UPS 2-22 Cisco ICS 7750 Administration and Troubleshooting Guide 78-10169-02 Rev. B0 Step 2 If any of the follo wing de vices are not turned on, power them on as follo ws: • UPS—Press the T est button on the UPS front panel. • Cisco ICS 7750—Press the po wer supply switches (on the right side of ...

  • APC 78-10169-02 - page 23

    2-23 Cisco ICS 7750 Administration and Troubleshooting Guide 78-10169-02 Rev. B0 Chapter 2 Monitoring the System Monitoring a UPS Step 6 Install the UPS: installups Step 7 Start FmmServer: net start FmmServer Step 8 Go to “V erifying That the Cisco ICS 7750 Can Communicate with the UPS” on page 2-26 . Configuring the System to Monitor a UPS Thr ...

  • APC 78-10169-02 - page 24

    Chapter 2 Monitoring the System Monitoring a UPS 2-24 Cisco ICS 7750 Administration and Troubleshooting Guide 78-10169-02 Rev. B0 While the system is attempting to communicate with the UPS, the f irst screen of the SNMP/W eb Card Management W izard continues to be displayed (this process might take se veral minutes). When the system is ready for yo ...

  • APC 78-10169-02 - page 25

    2-25 Cisco ICS 7750 Administration and Troubleshooting Guide 78-10169-02 Rev. B0 Chapter 2 Monitoring the System Monitoring a UPS Step 17 In the left pane of the browser windo w , choose Smart-UPS 1400 RM XL > Po werChute . Step 18 In the Add Client IP Address f ield, enter the IP address of the SPE running System Manager . Step 19 Click Add . T ...

  • APC 78-10169-02 - page 26

    Chapter 2 Monitoring the System Monitoring a UPS 2-26 Cisco ICS 7750 Administration and Troubleshooting Guide 78-10169-02 Rev. B0 Step 32 Log in as an administrator (userID administrator ), and enter your passw ord (the default is c hangeme ). Step 33 Enter the following command to stop the FMMServ er on the SPE: net stop FmmServer Step 34 Change t ...

  • APC 78-10169-02 - page 27

    2-27 Cisco ICS 7750 Administration and Troubleshooting Guide 78-10169-02 Rev. B0 Chapter 2 Monitoring the System Monitoring a UPS Step 5 V erify that the Cisco ICS 7750 can communicate with the UPS: fmmcli getchassisinfo | more Information similar to the following will be displayed: UPS status = AC Battery Level = <non-zero value> Batt. Span ...

  • APC 78-10169-02 - page 28

    Chapter 2 Monitoring the System Monitoring a UPS 2-28 Cisco ICS 7750 Administration and Troubleshooting Guide 78-10169-02 Rev. B0 ...

メーカー APC カテゴリー Computer Monitor

APC 78-10169-02のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 78-10169-02の取扱説明書
- APCの製品カード
- パンフレット
- またはAPC 78-10169-02の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、APC 78-10169-02の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、APC 78-10169-02の取り付け説明書、サービスマニュアル、簡易説明書、またはAPC 78-10169-02のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、APC 78-10169-02の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

APC 78-10169-02デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがAPC 78-10169-02を使用するのを助ける技術的文書のことです。説明書は通常、全てのAPC 78-10169-02ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

APCの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. APC 78-10169-02の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははAPC 78-10169-02の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。APC 78-10169-02に関してこのドキュメントで見つけることができる全てのヒントの目次
3. APC 78-10169-02デバイスの基本機能を使うにあたってのヒント。 APC 78-10169-02のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。APC 78-10169-02に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるAPC 78-10169-02のメーカー/サービスへの連絡先に関する情報。

APC 78-10169-02についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもAPC 78-10169-02の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがAPC 78-10169-02で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)