    Adtron Corporation Rev. 003 PN: 610200094 I I 3 3 5 5 M M B B - - 3 3 . . 5 5 ” ” M M i i r r r r o o r r e e d d H H a a r r d d D D i i s s k k O O p p e e r r a a t t i i o o n n s s M M a a n n u u a a l l March 2006 ...

  • ADTRAN 610200094 - page 2

    ESD Warning Before handling the I35MB, or any media associated with the I35MB, ensure that you are working in an ESD-safe environment. Notice This manual describes the features of the Adtron I35MB. Adtr on reserves the right to modify, amend, or in any way change the contents and/or products described herein, at any time, without notification. The ...

  • ADTRAN 610200094 - page 3

    Rev. 003, PN: 610200094 i Table of Contents Introduction 1 I35MB Features 1 Related Documents 2 I35MB Jumper Settings 2 Setting Master/Slave and Cable Select 3 Setting a Remote-Mounted Activity LED 3 Interface Connectors 4 I35MB Installation 4 Introduction 4 Inserting the I35MB 5 Removing the I35MB 6 Basic Operation 6 Partitioning and Formatting 6 ...

  • ADTRAN 610200094 - page 4

    A dtron I35MB Operations Manua l Rev. 003, PN: 610200094 1 Introduction The Adtron™ Diskpak™ Model I35MB with Adtron Acti veRAID™ technology incorporates RAID-1 mirroring in a 3.5-inch hard disk form factor. RAID-1 mirroring between two hard disk drives provides data redundancy and rebuild independent from the host CPU. With both disk driv es ...

  • ADTRAN 610200094 - page 5

    A dtron I35MB Operations Manua l Rev. 003, PN: 610200094 2 Related Documents • ANSI NCITS 340-2000 ATA/AT API-5 Specification • I35MB Product Specification • I35MB Installation Manual Static Sensitive – The I35MB is a static sensitive device. While setting jumpers, take precautions to ensure t hat static does not discharge into the I35MB. I ...

  • ADTRAN 610200094 - page 6

    A dtron I35MB Operations Manua l Rev. 003, PN: 610200094 3 Setting Master/Slave and Cable Select This IDE jumper is only for the configuration of master, slave, cable select and to mount a remote Activity LED. Figure 3 shows the pins of the IDE jumper on the I35MB. 1 3 4 2 5 6 1 3 4 2 5 6 1 3 4 2 5 6 Master Setting Slave Setting Cable Select Settin ...

  • ADTRAN 610200094 - page 7

    A dtron I35MB Operations Manua l Rev. 003, PN: 610200094 4 Interface Connectors The I35MB has an interface connector located on the front panel. Using an 80- conductor cable (40-pin connector); connect the I35MB to the primary or secondary ports on the IDE controller. Plug a power cable from the computer’s power supply into the I35MB power connec ...

  • ADTRAN 610200094 - page 8

    A dtron I35MB Operations Manua l Rev. 003, PN: 610200094 5 Inserting the I35MB To install the I35MB in the hard disk drive bay: 1. Power down the computer and remove the cover. 2. Make sure that you are properly grounded. 3. Set the master/slave to desired configurations. By defa ult, the I35MB is set to master. 4. Select a 3.5-inch drive bay that ...

  • ADTRAN 610200094 - page 9

    A dtron I35MB Operations Manua l Rev. 003, PN: 610200094 6 Removing the I35MB To remove the I35MB from the hard disk drive bay: 1. Make sure that you are properly grounded. 2. Power down the computer. 3. Remove the chassis casing. 4. Disconnect the 80-conductor cable and the computer power supply cable from the I35MB. 5. Unfasten the mounting screw ...

  • ADTRAN 610200094 - page 10

    A dtron I35MB Operations Manua l Rev. 003, PN: 610200094 7 I35MB LEDs and Mirror Control Buttons D14 D13 D12 D11 D10 Activity LED Bank 0 Access LED Bank 0 Fault LED Bank 1 Access LED Bank 1 Fault LED S4 Buzzer Reset S2 Bank 0 Mirror Control S3 Bank 1 Mirror Control Figure 7 LEDs and Mirror controls The LEDs are used to indicate individual Bank stat ...

  • ADTRAN 610200094 - page 11

    A dtron I35MB Operations Manua l Rev. 003, PN: 610200094 8 Mirror Control Button Functions The following figure shows the location of the mirror control buttons and LEDs on the I35MB. Bank 0 Mirror control Bank 1 Mirror control Buzzer Reset Figure 8 Mirror Control Button operations The following table describes the differe nt operations using the M ...

  • ADTRAN 610200094 - page 12

    A dtron I35MB Operations Manua l Rev. 003, PN: 610200094 9 Adtron recommends having a system ba ck-up available prior to managing hard or soft faults. Bank Hard Faults Hard fault errors may originate from any one of the following: • Write errors • Track 0 Not Found read error • HDD Timeout after a command If a hard fault occurs on one bank, t ...

  • ADTRAN 610200094 - page 13

    A dtron I35MB Operations Manua l Rev. 003, PN: 610200094 10 Rebuilding the faulted drive may take several hours, depending on the size of the media and may result in a hard fault if the drive cannot “map” around any “bad” sectors. While rebuilding can result in a reliable storage device and workable drive, Adtron recommends repl acing the d ...

  • ADTRAN 610200094 - page 14

    A dtron I35MB Operations Manua l Rev. 003, PN: 610200094 11 3. Note the bank number, 0 or 1, with the fault LED turned solid orange. This is the bank that requires attention. 4. Power down the computer. 5. Remove the computer cover and locate the I35MB in the disk drive bay. 6. Disconnect the power supply and 80-conductor cable from the I35MB. 7. U ...

  • ADTRAN 610200094 - page 15

    A dtron I35MB Operations Manua l Rev. 003, PN: 610200094 12 12. Before the disk drive is fully seated (a pproximately ¼ of an inch to t he drive being fully seated) re-attach the flex cable to the disk drive. Refer to Figure 10 for a view of this procedure. Carefully align and slowly attach. Pay close attention to mounting the flex cable. Ignoring ...

  • ADTRAN 610200094 - page 16

    A dtron I35MB Operations Manua l Rev. 003, PN: 610200094 13 Rebuilding a bank After a bank has been replaced, a rebuild must be performed. To start a Bank Rebuild, press the mirror control button between 5 and 10 seconds on the off-line bank. Release the button when the Access LED starts flashing at 2 blinks pe r second. The rebuild process begins, ...

  • ADTRAN 610200094 - page 17

    A dtron I35MB Operations Manua l Rev. 003, PN: 610200094 14 Examples: A new I35MB is installed in the field with two 20GB capacity media for 20GB of mirrored storage. Bank 1 requires replacement. A 10GB media is installed and the button pressed for rebuild. Rebuild will not start and the mirror remains broken. A 40GB media is then inserted in Bank ...

  • ADTRAN 610200094 - page 18

    A dtron I35MB Operations Manua l Rev. 003, PN: 610200094 15 Using the I35MB Rail Kit The following steps describe the process to disassemble and reassemble hard disk drives on the I35MB. Attention to individual instruct ions is necessary to ensure functionality and avoid dama ge to the device. Please contact Adtron Sales if assembling hard disk dri ...

  • ADTRAN 610200094 - page 19

    A dtron I35MB Operations Manua l Rev. 003, PN: 610200094 16 S.M.A.R.T. (Self-Monitoring, Analysis and Reporting Technology) Attributes The Adtron Diskpak I35MB incorporates an array of S.M.A.R.T. attribut es and capabilities that provide significant amou nts of informat ion relating to the life history of the hard disk drive (HDD). S. M.A.R.T. is a ...

  • ADTRAN 610200094 - page 20

    A dtron I35MB Operations Manua l Rev. 003, PN: 610200094 17 S.M.A.R.T Attribute Table S.M.A.R.T attributes are vendor specific pa rameters that are used in evaluating the status of the device. Adtron specific S.M.A.R.T attribut es are listed below. Many tools used to display S.M.A.R.T. attributes may not recogni ze Adtron specific attributes. Refer ...

  • ADTRAN 610200094 - page 21

    A dtron I35MB Operations Manua l Rev. 003, PN: 610200094 18 Attribute Number (8 bits) Name Value (8 bits) Raw Data (eight, 8-bit bytes) Threshold 194 (0xC2) Temperature Degrees C (Note 194) 0 199 (0xC7) (Note 199) UltraDMA error count 0 Unsigned integer 0 Table 3 S.M.A.R.T. Attributes S.M.A.R.T Attribute Notes Note Description 110 This value does n ...

  • ADTRAN 610200094 - page 22

    A dtron I35MB Operations Manua l Rev. 003, PN: 610200094 19 LED Indicators IDLE State – No host access Bank State Bank Access LED (Green/Orange) Bank Fault LED (Green/Orange) Drive Activity LED (Green/Orange) Description Normal GREEN OFF GREEN No host access Request off-line GREEN flashing (1/sec) OFF GREEN Button pushed while on-line. Fully off- ...

  • ADTRAN 610200094 - page 23

    A dtron I35MB Operations Manua l Rev. 003, PN: 610200094 20 ACTIVE State – Host access Bank State Bank Access LED (Green/Orange) Bank Fault LED (Green/Orange) Drive Activity LED (Green/Orange) Description Normal GREEN OFF ORANGE Host access in progress (reads or writes) Request off-line GREEN flashing (1/sec) OFF ORANGE Button pushed while on- li ...

  • ADTRAN 610200094 - page 24

    A dtron I35MB Operations Manua l Rev. 003, PN: 610200094 21 I35MB Dimension Drawings 25.3 .997 6-32 x 3.8[.150] MAX. DEPTH (3X) 101.6 4.000 5.750 146.1 Figure 11 I35MB ...

  • ADTRAN 610200094 - page 25

    A dtron I35MB Operations Manua l Rev. 003, PN: 610200094 22 Appendix I The table below lists the parts supplied on the I35MB Rail Kit. Items numbers correspond with Figure 11, under the section of this document ti tled, Using the I35MB Rail Kit . Item Number Quantity Description # 1 Four (4) Rail Retention Screw (M3 x 5) # 2 One (1) Rail – Left # ...

  • ADTRAN 610200094 - page 26

    A dtron I35MB Operations Manua l Rev. 003, PN: 610200094 23 Sales and Technical Support Contact Adtron Corporation for technical support, appl ication questions, data sheets, and documentation. Our normal business hours are Monday through Friday, 8am t o 5pm, MST. Headquarters – Sales Europe - Sales Adtron Corporation 4415 E. Cotton Center Blv d. ...

  • ADTRAN 610200094 - page 27

    A dtron I35MB Operations Manua l Rev. 003, PN: 610200094 24 Revision Control Rev Author Date Sections Description 001 JMH Apr 2005 All Original 002 JMH Aug 2005 Connector 8-pin change to the connector 003 JMH Mar 2006 SMART, Rail Kit Adding SMART attributes/ and information. Rail Kit guide. ...

メーカー ADTRAN カテゴリー Air Conditioner

ADTRAN 610200094のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 610200094の取扱説明書
- ADTRANの製品カード
- パンフレット
- またはADTRAN 610200094の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、ADTRAN 610200094の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、ADTRAN 610200094の取り付け説明書、サービスマニュアル、簡易説明書、またはADTRAN 610200094のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、ADTRAN 610200094の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

ADTRAN 610200094デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがADTRAN 610200094を使用するのを助ける技術的文書のことです。説明書は通常、全てのADTRAN 610200094ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

ADTRANの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. ADTRAN 610200094の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははADTRAN 610200094の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。ADTRAN 610200094に関してこのドキュメントで見つけることができる全てのヒントの目次
3. ADTRAN 610200094デバイスの基本機能を使うにあたってのヒント。 ADTRAN 610200094のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。ADTRAN 610200094に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるADTRAN 610200094のメーカー/サービスへの連絡先に関する情報。

ADTRAN 610200094についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもADTRAN 610200094の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがADTRAN 610200094で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)