Agilent Technologies 60502Bの取扱説明書

11ページ 0.04 mb
ダウンロード

ページに移動 of 11

Summary
  • Agilent Technologies 60502B - page 1

    OPERATING MANUAL 300 WATT ELECTRONIC LOAD MODULE Agilent Model 60502B FOR MODULES WITH SERIAL NUMBERS: 3118A-00101 AND ABOVE Agilent Part No. 60502-90008 Printed in U.S.A. Microfiche No. 60502-90009 June, 1991 ...

  • Agilent Technologies 60502B - page 2

    DECLARATION OF CONFORMITY according to ISO/IEC Guide 22 and EN 45014 Manufacturer’s Name : Agilent Technologies Manufacturer’s Address: New Jersey Division 140 Green Pond Road Rockaway, NJ 07866 U.S.A. declares that the product Product Name: Load mainframe and modules Model Number(s): Agilent 6050A, 6051A mainframes with modules Agilent 60501A/ ...

  • Agilent Technologies 60502B - page 3

    1 300-Watt Module About This Manual This manual provides information for the Agilent 60502B 300-Watt Electronic Load Module. It is designed as a supplement to the Agilent 6050A/6051A Multiple Input Mainframe Electronic Load Operating Manual (part number 06050- 90001). Four tables provide the following module-specific information: Table 60502-1 list ...

  • Agilent Technologies 60502B - page 4

    2 Table 60502-1. Specification and Supplemental Characteristics SPECIFICATIONS DC Input Rating: Current: 0 to 60 A Voltage : 3 V to 60 V (minimum dc operation from 0 to 2 V for 0 to 60 A) Power: 300 W at 40 ° C (derated to 225 W at 55 ° C) A. OPERATING CHARACTERISTICS B. DERATED CURRENT DETAIL Constant Current Mode: Ranges: 0 to 6 A; and 0 to 60 ...

  • Agilent Technologies 60502B - page 5

    3 Table 60502-1 Specifications and Supplemental Characteristics (continued) Transient Operation: Continuous Mode Frequency Range: 0.25 Hz to 10 kHz Frequency Resolution: 4% Frequency Accuracy: 3% Duty Cycle Range: 3% to 97% (0.25 Hz to 1 kHz); 6% to 94% (1 kHz to 10 kHz) Duty Cycle Resolution: 4% Duty Cycle Accuracy: 6% of setting ± 2% Pulsed Mode ...

  • Agilent Technologies 60502B - page 6

    4 Table 60502-1 Specifications and Supplemental Characteristics (continued) External Analog Programming 0 to 10 V (dc or ac): Bandwidth: 10 kHz (3 db frequency) Accuracy: ± 4.5% ± 75 mA (0 to 6 A range) ± 4.5% ± 250 mA (0 to 60 A range) ± 0.8% ± 200 mV (0 to 60 V range) Temperature Coefficient: 100 ppm/ ° C ± 6 mA/ ° C (current ranges) 100 ...

  • Agilent Technologies 60502B - page 7

    5 Table 60502-1 Specifications and Supplemental Characteristics (continued) Current Slew Rate:* Rate # 60 A Range Step 6 A Range Step Transition Time 1 1 A/ms 0.1 A/s 8.0 ms 2 2.5 A/ms 0.25 A/s 3.2 ms 3 5 A/ms 0.5 A/s 1.6 ms 4 10 A/ms 1 A/ms 800 µ s 5 25 A/ms 2.5 A/ms 320 µ s 6 50 A/ms 5 A/ms 160 µ s 7 0.1 A/ µ s 10 A/ms 80 µ s 8 0.25 A/ µ s ...

  • Agilent Technologies 60502B - page 8

    6 Table 60502-1 Specifications and Supplemental Characteristics (continued) Source Turn-On Current Overshoot: Less than 10% of final value (in CC and CR modes when connected to power supplies with voltage rise times of greater than 500 µ s). Programmable Short Circuit: 0.033 Ω (0.002 Ω typical) Programmable Open Circuit: 20 k Ω (typical) Dri ...

  • Agilent Technologies 60502B - page 9

    7 Table 60502-2. Programming Ranges (continued) Function Front Panel Front Panel HPSL Command Range of Values Key Display (Short Form) Transient Operation Set Frequency FREQ value "TRAN:FREQ value" 0.25 Hz to 10 kHz Set Duty Cycle (shift) DCYCLE value "TRAN:DCYC value" 3-97% (0.25 Hz-1 kHz) 6-94% (1 kHz-10 kHz) *Set Pulse Width ...

  • Agilent Technologies 60502B - page 10

    8 Table 60502-4. Calibration Information Ranges and Calibration Points Variables Variables Value Power Supply Settings Current Shunt High Current Range Hi_curr_rng 60 5 V/61 A 100 A High Current Offset Hi_curr_offset 0.0282 Low Current Range Lo_curr_rng 6 5 V/10 A 15 A Low Current Offset Lo_curr_offset 0.0197 Voltage Range N/A N/A 61 V/5 A N/A Volt ...

  • Agilent Technologies 60502B - page 11

    9 Agilent Sales and Support Office For more information about Agilent Technologies test and measurement products, applications, services, and for a current sales office listing, visit our web site: http://www.agilent.com/find/tmdir You can also contact one of the following centers and ask for a test and measurement sales representative. United Stat ...

メーカー Agilent Technologies カテゴリー Video Games

Agilent Technologies 60502Bのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 60502Bの取扱説明書
- Agilent Technologiesの製品カード
- パンフレット
- またはAgilent Technologies 60502Bの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Agilent Technologies 60502Bの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Agilent Technologies 60502Bの取り付け説明書、サービスマニュアル、簡易説明書、またはAgilent Technologies 60502Bのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Agilent Technologies 60502Bの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Agilent Technologies 60502Bデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがAgilent Technologies 60502Bを使用するのを助ける技術的文書のことです。説明書は通常、全てのAgilent Technologies 60502Bユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Agilent Technologiesの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Agilent Technologies 60502Bの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははAgilent Technologies 60502Bの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Agilent Technologies 60502Bに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Agilent Technologies 60502Bデバイスの基本機能を使うにあたってのヒント。 Agilent Technologies 60502Bのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Agilent Technologies 60502Bに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるAgilent Technologies 60502Bのメーカー/サービスへの連絡先に関する情報。

Agilent Technologies 60502Bについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもAgilent Technologies 60502Bの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがAgilent Technologies 60502Bで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)