  • Clarion MS2005 - page 1

    MS2005BO.QXD 6/27/2002 2:25 PM Page 1 ...

  • Clarion MS2005 - page 2

    C ongratulations on your purchase of this Ungo System. Please read this manual thoroughly to familiarize yourself with your system’s components and operation. Discuss any questions you might have with your installing dealer. Record the serial number of your Ungo System and keep all dealer records and receipts. Be sure to discuss the installation ...

  • Clarion MS2005 - page 3

    Table of Contents 1. About Your System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 1 2. Remote Transmitters Remote Transmitter Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 2 Optional Driver Door Priority Mode . . . . . . . . ...

  • Clarion MS2005 - page 4

    MS2005BO.QXD 6/27/2002 2:25 PM Page 4 ...

  • Clarion MS2005 - page 5

    The Ungo MS2005 is a state-of-the-art combination vehicle security and remote controlled car starter system. The MS2005 offers security features designed to deter and detect potential intrusions to your vehicle. It will alert and inform the driver and people in the vicinity of your vehicle when a zone is violated. The MS2005 will inform the user of ...

  • Clarion MS2005 - page 6

    Page 2 - MS2005 Owner’s Manual Remote Transmitter Layout The Ungo MS2005 comes with 2 multi-function Remote Transmitters used to control nearly all of the system’s features. Each time a transmitter button is pressed, the LED will flash to indicate that a transmission is taking place. Button 1 Arms the system. This button also locks the doors wh ...

  • Clarion MS2005 - page 7

    MS2005 Owner’s Manual - Page 3 Battery Replacement Your Ungo Remote Transmitter uses a 12 volt alkaline battery, which will need to be replaced from time to time. Under normal conditions, the battery should last for up to a year before it needs replacement. When your Remote Transmitter’s battery is in need of replacement, you will notice a decr ...

  • Clarion MS2005 - page 8

    Page 4 - MS2005 Owner’s Manual Remote Arming When Armed, the system monitors and protects 3 independent areas, or zones , including the doors, hood/trunk, and shock sensor. To Arm the system: 1. Turn off the ignition. 2. Press Button 1. • The siren/horn will chirp once.* • The doors will lock. • The parking lights will flash once. • The L ...

  • Clarion MS2005 - page 9

    MS2005 Owner’s Manual - Page 5 * The siren chirps and light flashes during disarming will alert you if the system had been triggered while armed. 2 chirps / 2 flashes = normal disarming 3 chirps / 3 flashes = Tamper Alert - system was triggered ** If the Passenger Unlock Feature is installed, pressing Button 2 will unlock only the driver’s door ...

  • Clarion MS2005 - page 10

    Page 6 - MS2005 Owner’s Manual To start the Passive Arming Process: 1. Turn off the ignition.* • The status LED will begin to flash quickly. 2. Open the door and exit the vehicle. • Once all doors are closed and the dome light is turned off, the LED will turn off. 3. After 20 seconds, • The siren will chirp (if Passive Arming with chirp is ...

  • Clarion MS2005 - page 11

    MS2005 Owner’s Manual - Page 7 3. Turn ignition key on. 4. Within 4 seconds, press and hold the Override switch. • The system will disarm. 5. You can now start and drive the car. Note: During installation, your installer can program the system to give 10 second entry delay when the system Arms passively. When the door is opened while the system ...

  • Clarion MS2005 - page 12

    Page 8 - MS2005 Owner’s Manual Remote Starting To Remote Start the System: 1. Be sure the System is not in Valet Mode. 2. Press Button 4. • The parking lights will turn on. • T he siren will chirp 3 times (if the system is Armed, the shock sensor will turn off). • The ignition will turn on. • The engine will start and run for the duration ...

  • Clarion MS2005 - page 13

    MS2005 Owner’s Manual - Page 9 To re-enter the vehicle and resume driver control: 1. Disarm the alarm by pressing Button 2 on the Remote Transmitter.* • The doors will unlock.* 2. Turn on the ignition. 3. Press the brake pedal to disengaged the MS2005. • The LED will turn off. *If optional keyless entry feature is installed. Auto Cold Startin ...

  • Clarion MS2005 - page 14

    Valet Mode Allows you to temporarily disable the security system when the car is being service or turned over to a parking attendant. To turn Valet Mode on or off: 1. Turn on the ignition. 2. Press and hold the override switch. 3. While holding the override switch, turn off the ignition. • The siren will chirp once to indicate you have turned Val ...

  • Clarion MS2005 - page 15

    Dome Light Control The dome light will turn on for 20 seconds when the system is disarmed (or unlocked in Valet Mode) using the Remote Transmitter. Auxiliary Function This function will operate regardless of whether the system is armed or disarmed and will stay active for as long as the Button 3 is held. T o operate the auxiliary function, press Bu ...

  • Clarion MS2005 - page 16

    Notes Page 12 - MS2005 Owner’s Manual MS2005BO.QXD 6/27/2002 2:25 PM Page 12 ...

  • Clarion MS2005 - page 17

    MS2005 Owner’s Manual - Page 13 You can use this chart to quickly identify and interpret your system’s chirp indications and LED flashes. Reference Chart Output When Status 1 chirp 1 + 4 chirps arming arming normal arming door, hood, or trunk is open no chirps LED double flashes arming Valet Mode Valet Mode is on Starter Defeat is activated 2 c ...

  • Clarion MS2005 - page 18

    Page 14 - MS2005 Owner’s Manual You can use these tables to quickly identify and interpret the MS2005’s parking light and LED indications. Technical Data System Indications Specifications Main Unit Voltage: 12v, negative ground Current Consumption: <15mA Temperature Range: -40 o F to +257 o F Auxiliary Output Capability: 500mA Internal Relay ...

  • Clarion MS2005 - page 19

    MS2005 Owner’s Manual - Page 15 1. Ungo Security Corporation of Gardena, California ("Ungo Security") warrants this Ungo system to be free from defects in materials and workmanship and to comply with Ungo Security’s applicable printed specifications. 2. Ungo Security systems carry a limited lifetime warranty on the Main unit (system b ...

  • Clarion MS2005 - page 20

    Ungo Security Corporation A Clarion Company 661 West Redondo Beach Blvd. Gardena, CA 90247 800-Go-Clarion www.clarion-usa.com © Ungo Security Corporation, Gardena, CA 97-MS2005-10 Rev. 2 (04/01) MS2005BO.QXD 6/27/2002 2:25 PM Page 16 ...

メーカー Clarion カテゴリー Automobile Alarm

Clarion MS2005のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- MS2005の取扱説明書
- Clarionの製品カード
- パンフレット
- またはClarion MS2005の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Clarion MS2005の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Clarion MS2005の取り付け説明書、サービスマニュアル、簡易説明書、またはClarion MS2005のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Clarion MS2005の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Clarion MS2005デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがClarion MS2005を使用するのを助ける技術的文書のことです。説明書は通常、全てのClarion MS2005ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Clarionの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Clarion MS2005の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははClarion MS2005の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Clarion MS2005に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Clarion MS2005デバイスの基本機能を使うにあたってのヒント。 Clarion MS2005のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Clarion MS2005に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるClarion MS2005のメーカー/サービスへの連絡先に関する情報。

Clarion MS2005についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもClarion MS2005の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがClarion MS2005で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (1)

Евгений

Хочу инструкцию на русском языке