  • Cooper Lighting Radio - page 1

    WR 3M - Operating Instructions 1 of 21 EN FR IT ES PT NL SV DK FI GR TR CZ PL HU SK SL EE LV LT Device Overview 1 Channel Selection LED Indicator 2 Heater Power LED Indicator 3 Vacuum “On” LED 4 LCD Display 5 UP Scroll Key 6 DOWN Scroll Key 7 Channel Selection Radio Buttons ┌ 1 ┐,┌ 2 ┐,┌ 3 ┐ 8 Start/Stop Pick-Up Radio Button 9 Statu ...

  • Cooper Lighting Radio - page 2

    Page 2 of 21 WR 3M Table of Contents 1 Instructions 2 2 Cautions and Warnings 2,3 3 Packing List 3 4 Description 3,4 5 Initial Set-up 5 6 Operating Guidlines 6 7 Special Functions 8 8 Maintaining and Servicing the WR 3M 16 9 Fault Indications and Correction 17 10 Accessories 18 11 Disposal 19 12 Warranty 19 1 Instructions Thank you for placing your ...

  • Cooper Lighting Radio - page 3

    WR 3M Page 3 of 21 EN FR IT ES PT NL SV DK FI GR TR CZ PL HU SK SL EE LV LT Safety Information: z Always place the solderi ng iron in its original holder z Remove all inflammable objects from the proximity of the hot soldering tool. z Use suitable protective clothi ng to prevent the risk of burns associated with molten solder. z Never leave a hot s ...

  • Cooper Lighting Radio - page 4

    Page 4 of 21 WR 3M The desired temperature can be adjusted in the range of 150°F t o 999°F for hot-air tools and the WSP150 Soldering Iron; 150°F to 850°F for all other soldering / desoldering tools. Set and Read values are displayed in digital form. Three Radio Buttons are used to select fixed / pre-set temperatures directly. The Heater Contro ...

  • Cooper Lighting Radio - page 5

    WR 3M Page 5 of 21 EN FR IT ES PT NL SV DK FI GR TR CZ PL HU SK SL EE LV LT The Weller WR 3M Rework Station offers the following additional features / functions: − Automatic tool detection and acti vation of the related control parameters − Operates with all Weller tools listed in the Accessories sectio n on page 18 − Digital Temperature Cont ...

  • Cooper Lighting Radio - page 6

    Page 6 of 21 WR 3M − can remotely control the unit and chart, store and print temper ature curves ("Monitor Software“). 5 Initial Set-up WARNING! • Risk of injury may occur i f vacuum hose is incorrectly connected to the air port (15). If the vacuum hose is incorrectly connected, hot air and liquid solder can escape when the desol dering ...

  • Cooper Lighting Radio - page 7

    WR 3M Page 7 of 21 EN FR IT ES PT NL SV DK FI GR TR CZ PL HU SK SL EE LV LT − LED lit green constantly indicates that the connected tool is being heated up. − LED flashing green indicates t hat the Set temperature of the tool has been reached. Active channels are indicated in the display with a triangle “ S ”(22) and a lightning symbol &quo ...

  • Cooper Lighting Radio - page 8

    Page 8 of 21 WR 3M 2. Depress the UP or DOWN Scroll Key. The display switches to the set value. The temperature symbol (18) flashes. 3. Depress the UP or DOWN Scroll Key to set the desired temperature: - Tapping the Scroll Keys changes the Set temperature by one degree. - Holding down the Scroll Keys changes the Set temperature rapidly. The Set val ...

  • Cooper Lighting Radio - page 9

    WR 3M Page 9 of 21 EN FR IT ES PT NL SV DK FI GR TR CZ PL HU SK SL EE LV LT 2 s ➾ Menu 1 4 s ➾ Menu 2 1x ➾ ON/OFF 2. The current air flow in percent age is shown in the display for approximately 2 seconds. 3. Set the desired flow by Depressing the UP or DOWN Scroll Key. 6.4 Switching the Vacuum Pick-up Pump ON/OFF Z Depress the Pick-Up Radio ...

  • Cooper Lighting Radio - page 10

    Page 10 of 21 WR 3M 1. Select the desired channel ┌ 1 ┐ , ┌ 2 ┐ or ┌ 3 ┐ for entering the special functions. 2. Depress and hold down the UP and DOWN Scroll Keys simultaneously. "– 1 –“ appears in the display after 2 seconds. 3. Release the Scroll Keys. Menu 1 is activated and the special functions can now be selected. - Sele ...

  • Cooper Lighting Radio - page 11

    WR 3M Page 11 of 21 EN FR IT ES PT NL SV DK FI GR TR CZ PL HU SK SL EE LV LT Setting the Automatic “Switch-Off” Time (AUTO-OFF) When the soldering tool is not i n use, heating of the soldering tool is switched off after the AUTO-OFF time has elapsed. The Auto-Off can be set from 0-999 minutes fo r each channel independently. With a setting of & ...

  • Cooper Lighting Radio - page 12

    Page 12 of 21 WR 3M 1) Not in use = UP/DOWN Scroll Keys not depressed and no temperat ure drop > 41 °F. 2) STANDBY temperature must be below the Set temperature, otherwi se the SETBACK function is inactive. 3) When a switching holder is connec ted, the soldering tool alway s remains at the Set temperature outside the holder. The holder function ...

  • Cooper Lighting Radio - page 13

    WR 3M Page 13 of 21 EN FR IT ES PT NL SV DK FI GR TR CZ PL HU SK SL EE LV LT the airflow is activated as l ong as the push-button on the hot- air pencil is depressed. 1. Select the menu item HAP-On in Menu 1. 2. Set the time value with the UP or DOWN Scroll Key. 3. Proceed to the next menu item with the Radio Button ┌ 1 ┐ (back) or ┌ 2 ┐ (f ...

  • Cooper Lighting Radio - page 14

    Page 14 of 21 WR 3M 2. Enter the 1, 2, or 3-digit LOCK code with the UP or DOWN Scroll Key. 3. Depress Radio Button ┌ 3 ┐ . The Station is now unlocked. Resetting the Special Functi ons to Factory Default Settings 1. Select the Special Functions Menu 1 . 2. Depress and hold down Radio Button ┌ 3 ┐ . 3. Then Depress the UP and DOWN Scroll Ke ...

  • Cooper Lighting Radio - page 15

    WR 3M Page 15 of 21 EN FR IT ES PT NL SV DK FI GR TR CZ PL HU SK SL EE LV LT requires a Station Identificati on (ID code) so that it can clea rly be identified. 1. Select the menu item REMOTE ID in Menu 2. 2. Enter an ID with the UP or DOWN Scroll Keys (possible values 0 – 999). 3. Proceed to the next menu item with the Radio Button ┌ 1 ┐ (ba ...

  • Cooper Lighting Radio - page 16

    Page 16 of 21 WR 3M 2. Select the menu item FCC in Menu 2. 3. Depress the UP Scroll Key. Control point 842 °F / 450 °C is selected. The soldering tip is now heated to 842 °F / 450 °C. The Heater Control Indicator flashes ( a ) (21) as soon as the temperature is constant. 4. Compare the temperatures indicated by the meter with the indications in ...

  • Cooper Lighting Radio - page 17

    WR 3M Page 17 of 21 EN FR IT ES PT NL SV DK FI GR TR CZ PL HU SK SL EE LV LT WARNING! Vacuum pump will be destr oyed if operated without the filter. Z Check to ensure the filters are in place before operating unit. Replacing the filter 1. Turn the cover cap for "Vac“ (14) or "Air“ (15) 45° counterclockwise and remove. 2. Pull out the ...

  • Cooper Lighting Radio - page 18

    Page 18 of 21 WR 3M − Clean desoldering tool – replace filter − Check vacuum hose 10 Accessories 0052918399 WMRP Micro Soldering-tip set, 40 W; WDH 30T Stand, RT3 tip. 0051514599 WMRH Micro Soldering Tool Switching Holder 0051317399 WMRT Micro Desoldering-tweezer set, 80 W 005xxxxxxx RTWX Tip set ??? 0051514699 WMRTH Micro Desolder ing-tweeze ...

  • Cooper Lighting Radio - page 19

    WR 3M Page 19 of 21 EN FR IT ES PT NL SV DK FI GR TR CZ PL HU SK SL EE LV LT 0058761732 Desoldering set 18/15.5/12.5/10 with pick-up 0051512499 WDC Weller Dry Tip Cleaner 0051512599 WDC 2 Dry Tip Cleaner for WDH Stands 0051303199 Lead Free Tip Tinner / Activator 0051350099 Cleaning Tool for Desoldering Pencils 0051312499 Spare Filters for DSX 80 De ...

  • Cooper Lighting Radio - page 20

    Page 20 of 21 WR 3M THE PERIOD OF ALL IMPLIED WARRANTIES APPLICABLE TO THIS PRODUCT INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS, OR FITNESS FOR A PARTICULAR PURPOSE IS LIMIT ED TO 12 MONTHS FROM THE DATE OF PURCHASE BY THE USER. Some states do not allow the excl usion or limitation of inciden tal or consequential damages, so the ab ...

  • Cooper Lighting Radio - page 21

    WR 3M Page 21 of 21 EN FR IT ES PT NL SV DK FI GR TR CZ PL HU SK SL EE LV LT Apex, N.C. 27539 Tel: (919) 387-0099 Fax: (919) 387-2379 For inquiries concer ning Technical / Customer Service please call: (800) 476-3030 Ext. 1 Canada Shipping Address: Cooper Tools 164 Innisfil Street Barrie, Ontario Canada L4N 3B7 Attn: Repairs Fax: 1-800-403-TOOL (86 ...

メーカー Cooper Lighting カテゴリー Stereo System

Cooper Lighting Radioのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- Radioの取扱説明書
- Cooper Lightingの製品カード
- パンフレット
- またはCooper Lighting Radioの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Cooper Lighting Radioの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Cooper Lighting Radioの取り付け説明書、サービスマニュアル、簡易説明書、またはCooper Lighting Radioのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Cooper Lighting Radioの製品を使用するにあたって最も人気のある説明書を閲覧できます。

Cooper Lighting Radioデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがCooper Lighting Radioを使用するのを助ける技術的文書のことです。説明書は通常、全てのCooper Lighting Radioユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Cooper Lightingの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Cooper Lighting Radioの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははCooper Lighting Radioの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Cooper Lighting Radioに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Cooper Lighting Radioデバイスの基本機能を使うにあたってのヒント。 Cooper Lighting Radioのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Cooper Lighting Radioに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き