Bunn TB3Qの取扱説明書

27ページ 0.99 mb
ダウンロード

ページに移動 of 27

Summary
  • Bunn TB3Q - page 1

    TB3Q TB3Q-LP OPERA TING & SERVICE MANUAL BUNN-O-MA TIC CORPORA TION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS 62708-3227 PHONE: (217) 529-6601 FAX: (217) 529-6644 www .bunnomatic.com 37236.0000C 05/05 ©2004 Bunn-O-Matic Corporation ...

  • Bunn TB3Q - page 2

    Page 2 CONTENTS User Notices .................................................................... 3 Electrical & Plumbing Requirements ............................... 4 Initial Set-Up .................................................................... 5 Auto Sweetener Set-Up .................................................... 6 Adjusting Brew ...

  • Bunn TB3Q - page 3

    Page 3 W ARNING ! Fill water tank before turning - on - thermostat or connecting appliance to power source. Use only on a properly protected circuit capable of the rated load. Electrically ground the chassis. Follow national/local electrical codes. Do not use near combustibles. F AILURE TO COMPL Y RISKS EQUIPMENT DAMAGE, FIRE, OR SHOCK HAZARD READ ...

  • Bunn TB3Q - page 4

    Page 4 ELECTRICAL REQUIREMENTS CAUTION - The brewer must be disconnected from the power sour ce until specified in Initial Set-Up. 120V model brewers require 2-wire, grounded service rated 120 volts ac, 15 amp, single phase, 60 Hz. "A" model brewers require 2-wire, grounded service rated 230 volts ac, 10 amp, single phase, 50 Hz. "B& ...

  • Bunn TB3Q - page 5

    Page 5 INITIAL SET -UP CAUTION - The brewer must be disconnected from the power sour ce throughout the Initial Set-Up, except when specified in the instructions. 1. Remove the top lid from the brewer . 2. Rotate the control thermostat knob fully counter clockwise to the "OFF" position and replace the top lid. 37236 050305 3. Insert an emp ...

  • Bunn TB3Q - page 6

    Page 6 37236 050305 AUTO SWEETENER SET -UP CAUTION - The brewer must be disconnected from the power sour ce throughout the Initial Set-Up, except when specified in the instructions. 1. Remove the top lid and both rear panels. 2. Make sure the brewer water supply is off. 3. Connect sweetener hose from the bag in a box delivery system to the rear fit ...

  • Bunn TB3Q - page 7

    Page 7 ADJUSTING BREW VOLUMES CAUTION - Disconnect the power sour ce from the brewer prior to the removal of any panel for the replacement or adjustment of any component. NOTE: Prior to setting or modifying batch sizes, check that the brewer is connected to water supply , the tank is properly filled, and a funnel and server are in place. 1. Modifyi ...

  • Bunn TB3Q - page 8

    Page 8 OPERA TING CONTROLS A. ON/OFF Switch ON - Placing the switch in the left position allows the start switch to activate a timed brew cycle for three gallons of tea. OFF - Placing the switch in the right position stops the brew cycle. Stopping a brew cycle after it has been started will not stop the flow of water into the funnel until the tank ...

  • Bunn TB3Q - page 9

    Page 9 37236 080504 TEA BREWING 1. Begin each brew cycle with a clean empty brew funnel and server . (Be sure the ser ver lid doesn’t inter fere with the flow of dilution water .) 2. Insert a BUNN® filter into the funnel. 3. Pour the packet of loose fresh tea leaves into the filter . Approximately three to five ounces is recommended for three ga ...

  • Bunn TB3Q - page 10

    Page 10 TROUBLESHOOTING A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic T echnical Ser vice Department. • Inspection, testing, and repair of electrical equipment should be performed only ...

  • Bunn TB3Q - page 11

    Page 11 TROUBLESHOOTING (cont.) PROBLEM PROBABLE CAUSE REMEDY Brew cycle will not start (cont.) Water is not hot Dilution cycle will not start Inconsistent beverage level in dispenser 6. Brew Timer 7. Brew Solenoid Valve 1. Limit Thermostat CAUTION - Do not eliminate or by- pass limit thermostat or thermal cut-off. Use only BOM replacement part #29 ...

  • Bunn TB3Q - page 12

    Page 12 TROUBLESHOOTING (cont.) PROBLEM PROBABLE CAUSE REMEDY Consistently high or low beverage level in the dispenser Spitting or excessive steaming Drip-out time too long Sweetener is not working 1. Strainer/Flow Control (.750GPM) 1. Lime Build-up CAUTION - T ank and tank compo- nents should be delimed regularly depending on local water condi- ti ...

  • Bunn TB3Q - page 13

    Page 13 TROUBLESHOOTING (cont.) PROBLEM Dripping from sprayhead Water flows into tank continuously (ON/OFF Switch "ON") (UNSWEET/OFF/SWEET Switch in "UNSWEET" or "SWEET" position) Water flows into tank continuously (ON/OFF Switch "OFF") (UNSWEET/OFF/SWEET Switch in "OFF" position. Beverage overflows ...

  • Bunn TB3Q - page 14

    Page 14 TROUBLESHOOTING (cont.) PROBLEM Weak beverage (cont.) Dr y tea leaves remain in the funnel Brewer is making unusual noises PROBABLE CAUSE 4. Funnel Loading 5. Water T emperature 6. Low Brew Water V olume 1. Funnel Loading 1. Solenoid(s) 2. Plumbing Lines 3. Water Supply 4. T ank Heater REMEDY The BUNN® paper filter must be centered in the ...

  • Bunn TB3Q - page 15

    Page 15 SERVICE This section provides procedures for testing and replacing various major components used in this brewer should service become necessar y . Refer to T roubleshooting for assistance in determining the cause of any problem. WARNING - Inspection, testing, and repair of electri- cal equipment should be performed only by qualified service ...

  • Bunn TB3Q - page 16

    Page 16 SERVICE (cont.) BREW SOLENOID V AL VE FIG. 2 BREW SOLENOID V AL VE P3046 Location: Viewing the brewer from the top, the brew sole- noid valve is mounted on the right side of the brewer. Test Procedures: 1. Disconnect the brewer from the power source. 2. Disconnect the white/violet and white/green wires from the solenoid valve. With the ON/O ...

  • Bunn TB3Q - page 17

    Page 17 SERVICE (cont.) DIGIT AL BREW TIMER FIG. 4 DIGIT AL BREW TIMER P3047 Location: The timer is located inside the hood, on the left side. Test Procedure. NOTE: Do not remove or install wires while timer board is installed. Pressure applied to one side may cause damage to the board. 1. Disconnect the brewer from the power source and remove the ...

  • Bunn TB3Q - page 18

    Page 18 SERVICE (cont.) TL1 - WHI to Power Cord (100V & 120V) or RED to Power Connector (230V) and WHI to On/Off Switch (100V & 120V) or RED to On/Off Switch (230V) TL2 - WHI/VIO to Brew Solenoid and WHI/VIO to On/Off Switch TL3 - WHI/ORN to Start Switch TL4 - WHI/GRN to Brew Solenoid TL5 - WHI/YEL to Start Switch FIG. 5 DIGIT AL TIMER WIRI ...

  • Bunn TB3Q - page 19

    Page 19 SERVICE (cont.) CONTROL THERMOST A T FIG. 6 CONTROL THERMOST A T P3047 Location: The control thermostat is located inside hood on the right side. Test Procedures: 1. Disconnect the brewer from the power sour ce. 2. Locate the blue/black wire on the control thermo- stat. 3. With a voltmeter , check the voltage across the blue/ black wire on ...

  • Bunn TB3Q - page 20

    Page 20 SERVICE (cont.) LIMIT THERMOST A T FIG. 8 LIMIT THERMOST A T P3047 Location: The limit thermostat is located inside the hood on the tank lid. T est Procedure: 1. Disconnect the brewer from the power source and remove the black wire from the limit thermostat. 2. With a voltmeter , check the voltage across the black wire removed from the limi ...

  • Bunn TB3Q - page 21

    Page 21 SERVICE (cont.) ON/OFF SWITCH FIG. 10 ON/OFF SWITCH P3034 Location: The ON/OFF switch is located in the front of the hood, above and to the left of the brew funnel. T est Procedure: 1. Disconnect the brewer from the power sour ce. 2. Remove the black and white/violet wires from the switch terminals. 3. With a voltmeter , check the voltage a ...

  • Bunn TB3Q - page 22

    Page 22 If continuity is present as described, reconnect the wires, the switch is operating properly . If continuity is not present as described, replace the switch. Removal and Replacement: 1. Remove the wires from the switch terminals. 2. Compress the clips inside the hood and gently push the switch through the opening. 3. Push the new switch int ...

  • Bunn TB3Q - page 23

    Page 23 FIG.15 UNSWEET/OFF/SWEET SWITCH TERMINALS P1763 37236 050305 SERVICE (cont.) UNSWEET/OFF/SWEET SWITCH (Sweetner Option) FIG. 14 UNSWEET/OFF/SWEET SWITCH P3034 Location: The UNSWEET/OFF/SWEET switch is located in the front of the hood, above and to the left of the brew funnel. T est Procedure: 1. Disconnect the brewer from the power sour ce. ...

  • Bunn TB3Q - page 24

    Page 24 37236 050305 SERVICE (cont.) SWEETNER SOLENOID V AL VE FIG. 16 SWEETNER SOLENOID V AL VE P3298 FIG. 17 SOLENOID V AL VE TERMINALS P2843 WHI/VIO to Brew Solenoid WHI/VIO to Brew Timer TL1 BRN/WHI to Selector Switch Location: Viewing the brewer from the front, the sweetener solenoid is mounted on the right side of the solenoid mounting bracke ...

  • Bunn TB3Q - page 25

    Page 25 SERVICE (cont.) T ANK HEA TER FIG. 18 T ANK HEA TER Location: The tank heater is located inside the tank and se- cured to the tank lid. T est Procedures: 1. Disconnect the brewer from the power supply . 2. With a voltmeter , check the voltage across the black and white wires on 100 volt and 120 volt models or the black and red wires for 230 ...

  • Bunn TB3Q - page 26

    Page 26 LIMIT THERMOSTAT BLU/BLK TANK HEATER "KEEP WARM" HEATER START L1 N BLK WHI BLK BREW TIMER WHI WHI GREEN WHI/YEL WHI/ORA BLK WHI/GRN WHI/VIO WHI BRN/WHI WHI/VIO WHI WHI SCHEMATIC WIRING DIAGRAM TB3Q W/SWEETENER 120 VOLTS AC 2 WIRE SINGLE PHASE THERMOSTAT SOL 1 2 3 4 5 SOL WHI/GRN WHI/VIO BREW SWTNR UNSWEET/OFF/SWEET (OPTIONAL) READ ...

  • Bunn TB3Q - page 27

    Page 27 37236 050305 SCHEMA TIC WIRING DIAGRAM TB3QA LIMIT THERMO S TAT S W1 BREW TIMER BLK BLK BLK BLU/BLK RED RED RED WHI WHI WHI/VIO WHI/VIO WHI/GRN WHI/GRN WHI/ORN L1 L2 GRN/YEL WHI/YEL 37234.0003A 11/04 © 2004 BUNN-O-MA TIC CORPORA TION 230 VOL TS AC 2 WIRE SINGLE PHASE S OL S W2 "KEEP WARM" HEA TER T ANK HEA TER THERMAL FU S E THER ...

メーカー Bunn カテゴリー Ice Tea Maker

Bunn TB3Qのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- TB3Qの取扱説明書
- Bunnの製品カード
- パンフレット
- またはBunn TB3Qの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Bunn TB3Qの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Bunn TB3Qの取り付け説明書、サービスマニュアル、簡易説明書、またはBunn TB3Qのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Bunn TB3Qの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Bunn TB3Qデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがBunn TB3Qを使用するのを助ける技術的文書のことです。説明書は通常、全てのBunn TB3Qユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Bunnの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Bunn TB3Qの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははBunn TB3Qの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Bunn TB3Qに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Bunn TB3Qデバイスの基本機能を使うにあたってのヒント。 Bunn TB3Qのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Bunn TB3Qに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるBunn TB3Qのメーカー/サービスへの連絡先に関する情報。

Bunn TB3Qについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもBunn TB3Qの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがBunn TB3Qで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください