Manual HP (Hewlett-Packard) 6.5

20 pages 0.54 mb
Download

Go to site of 20

Summary
  • HP (Hewlett-Packard) 6.5 - page 1

    Upgrading to Novell NetWare 6.5 on ProLiant servers integration note Abstract .............................................................................................................................................. 2 Introduction to Novell NetWare 6.5 ............................................................................................ ...

  • HP (Hewlett-Packard) 6.5 - page 2

    Abstract This integration note provides requir ements and guidelines for upgrading from Novell NetWare 5.1 and 6 to Novell NetWare 6.5 on ProLiant servers. More specifically, we disc uss the following four topics: • Enhancements of Novell NetWare 6.5 • Comprehensive upgrade plan • Upgrading to Novell NetWare 6.5 • Post upgrade tasks This in ...

  • HP (Hewlett-Packard) 6.5 - page 3

    Comprehensive upgrade plan When considering upgrading your server to a more powerful operating system, it is important to evaluate your existing hardware components. Thi s evaluation is a necessity when upgrading to NetWare 6.5 due to applications such as eDirectory , iFolder, iPrint, and Apache Web Server, which require increased amounts of RAM an ...

  • HP (Hewlett-Packard) 6.5 - page 4

    Server platforms Table 2 lists the ProLiant servers that c urrently suppo rt NetWare 6.5. For the latest information, refer to the ProLiant Supported OS Matrix available at ftp://ftp.compaq.com/pu b/products/servers/os- support-matrix-310.pdf . Table 2. Supported system platforms CL servers DL servers ML servers ProLiant CL380 ProLiant DL360 (all g ...

  • HP (Hewlett-Packard) 6.5 - page 5

    Option Driver Location StorageWorks ESL9326 Family DLT/SDLT Library Vendor Specific NetWare 6.5 Operating System CD StorageWorks ESL9322L1 LTO-1 Tape Library Vendor Specific NetWare 6.5 Operating System CD StorageWorks ESL9322S2 SDLT Tape Library Vendor Specific NetWare 6.5 Operating System CD StorageWorks ESL9595L1 LTO-1 Tape Library Vendor Specif ...

  • HP (Hewlett-Packard) 6.5 - page 6

    Table 4 lists supported ProLiant storage devi ces and controllers and drivers supported by NetWare 6.5. Table 4. Supported ProLiant storage devices 1 Option Driver Location Compaq 4.3 – 145.6 GB Hard Disk Drives CPQSHD.CDM NetWare 6.5 Operating System CD Compaq 64-Bit Dual Channel Wide- Ultra2 SCSI Controller CPQSCSI.HAM NetWare 6.5 Operating Sys ...

  • HP (Hewlett-Packard) 6.5 - page 7

    Supported network interface controllers Table 5 lists supported ProLiant network interfac e controllers (NICs) and drivers supported by NetWare 6.5. Table 5. Supported ProLiant NICs 3 NIC Driver Location NC3120 Fast Ethernet N100.LAN NetWare 6.5 Operating System CD NC3121 Fast Ethernet N100.LAN NetWare 6.5 Operating System CD NC3122 Fast Ethernet N ...

  • HP (Hewlett-Packard) 6.5 - page 8

    ProLiant cluster support The following platforms support NetWare 6.5 clustering: • ProLiant CL380 Packaged Cluster • ProLiant DL380 G2 Packaged Cluster • ProLiant DL380 G3 Packaged Cluster • ProLiant DL360 • ProLiant DL360 G2 • ProLiant DL360 G3 • ProLiant DL380 • ProLiant DL380 G2 • ProLiant DL380 G3 • ProLiant DL560 • ProLia ...

  • HP (Hewlett-Packard) 6.5 - page 9

    Table 6. Supported ProLiant value-add software Utility Module name Minimum version Server Health Driver CPQHLTH.NLM CPQASM.NLM 5.08 Server Agents CPQBSSA.NLM CPQHTHSA.NLM CPQRISA.NLM CPQSERV.RDM 6.41 Foundation Agents CPQAGIN.NLM CPQHOST.NLM CPQHMMO.NLM CPQTHRSA.NLM CPQWEBAG.NLM CPQHLTAG.CFG CPQSNMP.CFG CPQFOUND.RDM 6.41 NIC Agents CPQNCSA.NLM CPQN ...

  • HP (Hewlett-Packard) 6.5 - page 10

    Utility Module name Minimum version NIC Teaming Driver for N100.LAN and N1000.LAN Drivers CPQANS.LAN CPQANS.LDI 7.03 NIC Teaming Drivers for Q57.LAN Driver QASP.LAN QASP.LDI BMAPI.NLM 2.19 All other HP specific drivers needed to in stall and run NetWare 6.5 are included on the NetWare 6.5 base media, as well as on the Ne tWare 6.5 PSP mentioned pre ...

  • HP (Hewlett-Packard) 6.5 - page 11

    .NCF files onto a blank diskette. These settings may be required if a restore is necessary. When porting software applications to the new system, contact the appropriate vendor for instructions. Upgrade procedures There are two options available for upgrading Nove ll servers. NetWare 6.5 may be installed through a Standard In-Place Upgrade or throu ...

  • HP (Hewlett-Packard) 6.5 - page 12

    • • • • Runs a cluster health check (on clust ered servers only ). Provides steps to verify that the host CA object is running Novell Certificat e Server version 2.0 or later. Provides preparation steps for implementi ng Novell’s Universal Password. Provides preparation steps for enabling CIFS (M icrosoft Windows native network workstatio ...

  • HP (Hewlett-Packard) 6.5 - page 13

    Note HP recommends selecting Manual , as there is a driver that may need to be changed during the upgrade. 16. Select Next to begin the file copy. 17. After the file copy completes, the Components page displays, allowing you to choose any additional NetWare 6.5 products for installation. To see a description of a product, place the cursor over the ...

  • HP (Hewlett-Packard) 6.5 - page 14

    b. Press Enter . c. Make any desired changes. d. Select Continue . e. Press Enter . 22. The file copy continues, and the GUI port ion of the installation process begins. 23. When prompted, login to eDirectory (NDS) as a us er with Admin rights. Af ter successfully logging in, eDirectory upgrades to the latest version. Select Next when co mp lete. 2 ...

  • HP (Hewlett-Packard) 6.5 - page 15

    Post upgrade tasks Updating NSS Volumes If you upgraded from a NetWare 5.1 server with NSS volumes, you must complete the following procedure to update NSS volumes. Note For more detailed information, see Upgrading NetWare 5 NSS Volumes in the Novell Storage Services Administration Guide fo r NetWare 6.5 . 1. When prompted at the end of the upgrade ...

  • HP (Hewlett-Packard) 6.5 - page 16

    Issue 2 Accessing the B: drive during installation will hang the server Description Attempting to access the B: drive during the GUI p ortion of the server installation will cause the server to hang. This problem on ly occurs during server installation. Workaround The only available workaround is to restart the server installation. Solution This ...

  • HP (Hewlett-Packard) 6.5 - page 17

    Issue 6 Software RAID 5 not supported Description HP and Novell have discovered issues wh ere failed drives in softwar e RAID 5 environments may not properly rebuild and data corruption may occur. Workaround Use software RAID 0 or 1, or use hardware RAID 5 as an alternative. Solution Novell is communicating to customers that so ftware RAID 5 will n ...

  • HP (Hewlett-Packard) 6.5 - page 18

    Issue 12 CD volumes not mounting after installing NetWare Service Pack 6 on NetWare 5 .1 English Only installations causes upgrade to NetWare 6.5 to fail Description During an SP6 installation on Net Ware 5.1 English Only OS installations, answering "NO" when prompted to update the St orage/LAN /PSM/WAN drivers causes CD volumes not to mo ...

  • HP (Hewlett-Packard) 6.5 - page 19

    Workaround Select Do not downgrade during the instal lation, and keep the latest version of NCMCON.C FG. Solution Install PSP 7.00 (from the web or through the SmartStart CD when available) to obtain the latest NCMCON.CFG. Issue 17 Virtual CD-ROM in iLO and RILOE II does not work Description The Virtual CD-ROM function does not work with NetWare 6. ...

  • HP (Hewlett-Packard) 6.5 - page 20

    For more information The NetWare 6.5 Welcome scree n provides helpful in formation for getting the most out of your new NetWare 6.5 server. To access the Welcome screen, op en a browser on a workstation with access to the new NetWare 6.5 server and go to http://xxx.xxx.xxx.xxx , where xxx.xxx.xxx.xxx is the new server's IP address. For additio ...

Manufacturer HP (Hewlett-Packard) Category Frozen Dessert Maker

Documents that we receive from a manufacturer of a HP (Hewlett-Packard) 6.5 can be divided into several groups. They are, among others:
- HP (Hewlett-Packard) technical drawings
- 6.5 manuals
- HP (Hewlett-Packard) product data sheets
- information booklets
- or energy labels HP (Hewlett-Packard) 6.5
All of them are important, but the most important information from the point of view of use of the device are in the user manual HP (Hewlett-Packard) 6.5.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals HP (Hewlett-Packard) 6.5, service manual, brief instructions and user manuals HP (Hewlett-Packard) 6.5. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product HP (Hewlett-Packard) 6.5.

A complete manual for the device HP (Hewlett-Packard) 6.5, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use HP (Hewlett-Packard) 6.5 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of HP (Hewlett-Packard) 6.5.

A complete HP (Hewlett-Packard) manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual HP (Hewlett-Packard) 6.5 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the HP (Hewlett-Packard) 6.5, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the HP (Hewlett-Packard) 6.5, that we can find in the current document
3. Tips how to use the basic functions of the device HP (Hewlett-Packard) 6.5 - which should help us in our first steps of using HP (Hewlett-Packard) 6.5
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with HP (Hewlett-Packard) 6.5
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of HP (Hewlett-Packard) 6.5 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning HP (Hewlett-Packard) 6.5?

Use the form below

If you did not solve your problem by using a manual HP (Hewlett-Packard) 6.5, ask a question using the form below. If a user had a similar problem with HP (Hewlett-Packard) 6.5 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)