    IMPORT ANT - PLEASE READ AND FOLLOW ✓ Before beginning, please r ead these instructions completely and carefully . ✓ Do not remove permanently af fixed labels, warnings, or plates from the product. This may void the warranty . ✓ Please observe all local and national codes and ordinances. ✓ Please ensure that this pr oduct is properly gr oun ...

  • DeLonghi DEFSGG 24 SS - page 2

    2 ✓ Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. ✓ WHA T TO DO IF YOU SMELL GAS: • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • lmmediately call your gas supplier from a neighbor's phone. Follow t ...

  • DeLonghi DEFSGG 24 SS - page 3

    3 DA T A PLA TE CONVERSION LABEL This appliance is designed and manufactured solely for the cooking of domestic (household) food and in not suitable for any none domestic application and therefor e should not be used in a commercial envir onmement. The appliance guarantee will be void if the appliance is used within a none domestic environnement i. ...

  • DeLonghi DEFSGG 24 SS - page 4

    4 W ARNING! THIS APPLIANCE HAS TO BE INST ALLED BY A QUALIFIED INST ALLER. Improper installation, adjustment, alteration, services, or maintenance can cause injury or pr operty damage. Consult a qualified installer , service agent, or the gas supplier . IMPORT ANT : The use of suitable protective clothing/gloves is r ecommended when handling, insta ...

  • DeLonghi DEFSGG 24 SS - page 5

    5 GENERAL INFORMA TION 1. Installation must conform with local codes or , in the absence of local codes, with the National Fuel Gas Code , ANSI Z223.1-Latest Edition. 2. Installation in manufactured (mobile) home: installation must conform with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 [formerly the Federal Sta ...

  • DeLonghi DEFSGG 24 SS - page 6

    6 (303 m m ) (303 m m ) 11" 15/16 11" 15/16 (150 mm) 5" 57/64 installation  PROXIMITY TO SIDE CABINETS 1. This range may be installed directly adjacent to existing 36" (914 mm) high base cabinets. Range dimensions: • width: 23” 7/8 (606.5 mm) • depth: 24” 5/64 (611.6 mm) • height (without backguard): MIN 35” 7/16 ...

  • DeLonghi DEFSGG 24 SS - page 7

    7  A B A (914 mm) 36" 30" min. (762 mm) (457 mm) 18" min. 0" 0" (0 m m ) (0 m m ) 20" min. (500 mm) 1 1 " 13/16 m in . (3 0 0 m m ) 13" max. (330 mm) 0" (0 m m ) 3" min. (76 mm) 13" max. (330 mm ) (914 mm) 36" 0" (0 m m ) 2 0 " m in . (5 0 0 m m ) 30" min. (762 mm) (457 m ...

  • DeLonghi DEFSGG 24 SS - page 8

    8  LEVELLING THE RANGE The range is equipped with 4 LEVELLING FEET and may be levelled by scr ewing or unscrewing the feet with a spanner (fig. 1.8). It is important to observe the directions of figures 1.6, 1.7a, 1.7b . + 8 mm + 5/16" + 8 mm + 5/16" 0 mm 0" + 20 mm + 25/32" Fig. 1.6 Fig. 1.7a Fig. 1.7b Fig. 1.8 A ...

  • DeLonghi DEFSGG 24 SS - page 9

    9 gas connection  Gas supply line Shutoff valve “open” position To range Explosion Hazard Use a new CSA or UL approved gas supply line. Install a shut-off valve. Securely tighten all gas connec- tions. If connected to LP , have a quali- fied person make sure gas pr es- sure does not exceed 14" water column. Examples of a qualified perso ...

  • DeLonghi DEFSGG 24 SS - page 10

    10  PRESSURE REGULA TOR INST ALLA TION LOCK Arrow STEP 1 Mount the 1/2” NPT (conical) male connector to the pressur e r egulator and tighten by using a wr ench. Do not over tighten the connector . Over tightening may crack regulator . STEP 2 Assemble the 1/2” NPT connector + pressur e regulator group to the extension pipe interposing the gas ...

  • DeLonghi DEFSGG 24 SS - page 11

    11  To mains connection Manifold test point pressure 1/8” NPT To range Range manifold Manifold male pipe fitting Connector Pressure regulator 1/2” G cylindrical (ISO 228-1) male 1/2” G cylindrical (ISO 228-1) female 1/2” NPT (conical) male 1/2” NPT female 1/2” NPT female WARNING: check the right positioning of the gas regulator. The ...

  • DeLonghi DEFSGG 24 SS - page 12

    12  To mains connection To range Manifold test point pressure 1/8” NPT Screw Unscrew Fig. 2.5 5. Leak T esting: IMPORT ANT : Leak testing of the appliance shall be conducted as follows: • After final gas connection is made, turn on manual gas valve and test all connections in gas supply piping and appliance for gas leaks with a soapy water s ...

  • DeLonghi DEFSGG 24 SS - page 13

    13  1 2 3 4 Fig. 2.6b Fig. 2.6a REGULA TOR COVER Pressur e r egulator CONVERSION TO LP/PROP ANE GAS Every range is provided with a set of injectors for the various types of gas. Select the injectors to be replaced accor ding to the “INJECTORS T ABLE”. The nozzle diameters, expressed in hundr edths of a millimetre, ar e marked on the body of ...

  • DeLonghi DEFSGG 24 SS - page 14

    14  SETTING THE BURNER MINIMUM When switching from one type of gas to another , the minimum flow rate must also be correct: the flame should not go out even when passing suddenly fr om maximum to minimum flame. To r egulate the flame follow the instructions below: – Light the burner – Set the gas valve to position – Remove the knob – Wit ...

  • DeLonghi DEFSGG 24 SS - page 15

    15  OPERA TIONS TO BE EXECUTED FOR THE REPLACEMENT OF THE INJECTORS OF THE OVEN AND BROIL BURNERS a) Oven Burner – Lift and remove the lower panel inside the oven. – Remove the burner securing screw (fig. 2.10). – Withdraw the burner as shown in figure 2.11 and rest it inside the oven. T ake care not to damage the wire to the ignition elec ...

  • DeLonghi DEFSGG 24 SS - page 16

    16  After regulation r epeat the operations indicated in paragraph “2. Pressure r egulator” at page 9. If the range has been disconnected and then connected again to the gas supply line r epeat the operations indicated in paragraph “5. Leak T esting” at page 12. IMPORT ANT : After conversion to LP/PROP ANE gas has been carried out affix ...

  • DeLonghi DEFSGG 24 SS - page 17

    17 electrical connection  If codes permit and a separate ground wir e is used, it is recommended that a qualified electrician determine that the ground path is adequate. Check with a qualified electrician if you are not sur e whether the range is proper- ly grounded. Do Not ground to a gas pipe. A 120-volt, 60-Hz, AC-only , 15-ampere, fused elec ...

  • DeLonghi DEFSGG 24 SS - page 18

    18  WIRING DIAGRAM Fig. 3.2 P1 F1 MS AS CF N/7 L/8 S1 PA TL3 V T LF EC A M N L ELECTRIC DIAGRAM KEY F1 Switch MS Security microswitch S1 Cooling fan safety lamp LF Oven lamp AS Air switch V Fan TL3 Thermal overload PA Ignition switches group A Ignition coil EC Electronic clock CF Cooling fan M Te r m inal block T Earth connection ...

  • DeLonghi DEFSGG 24 SS - page 19

    19 ...

  • DeLonghi DEFSGG 24 SS - page 20

    Cod. 1102749 - ß3 The manufacturer cannot be held responsible for possible inaccuracies due to printing or transcription err ors in the present booklet. The manufacturer reserves the right to make all modifications to its pr oducts deemed necessary for manufacture or commercial reasons at any moment and without prior notice, without jeopar dising ...

Manufacturer DeLonghi Category Range

Documents that we receive from a manufacturer of a DeLonghi DEFSGG 24 SS can be divided into several groups. They are, among others:
- DeLonghi technical drawings
- DEFSGG 24 SS manuals
- DeLonghi product data sheets
- information booklets
- or energy labels DeLonghi DEFSGG 24 SS
All of them are important, but the most important information from the point of view of use of the device are in the user manual DeLonghi DEFSGG 24 SS.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals DeLonghi DEFSGG 24 SS, service manual, brief instructions and user manuals DeLonghi DEFSGG 24 SS. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product DeLonghi DEFSGG 24 SS.

Similar manuals

A complete manual for the device DeLonghi DEFSGG 24 SS, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use DeLonghi DEFSGG 24 SS by users. Manuals are usually written by a technical writer, but in a language understandable to all users of DeLonghi DEFSGG 24 SS.

A complete DeLonghi manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual DeLonghi DEFSGG 24 SS - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the DeLonghi DEFSGG 24 SS, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the DeLonghi DEFSGG 24 SS, that we can find in the current document
3. Tips how to use the basic functions of the device DeLonghi DEFSGG 24 SS - which should help us in our first steps of using DeLonghi DEFSGG 24 SS
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with DeLonghi DEFSGG 24 SS
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of DeLonghi DEFSGG 24 SS in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning DeLonghi DEFSGG 24 SS?

Use the form below

If you did not solve your problem by using a manual DeLonghi DEFSGG 24 SS, ask a question using the form below. If a user had a similar problem with DeLonghi DEFSGG 24 SS it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)