    1 W415-0583 / B / 05.23.07 INST ALLA TION AND OPERA TION INSTRUCTIONS Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031 www .napoleonfireplaces.com • ask@napoleon.on.ca INST ALLER: THESE INSTRUCTIONS MUST BE CONVEYED T O AND REMAIN WITH THE HOMEOWNER. GD82NT -T NA TURAL GAS GD82PT -T PROP ANE W ARN ...

  • Napoleon Fireplaces GD82NT-T - page 2

    2 W415-0583 / B / 05.23.07 PG 2-5 INTRODUCTION W arranty Dimensions General Instructions General Information Care of Glass & Plated Parts 5-9 VENTING V ent lengths V enting Specifi cations Air T erminal Locations 10-15 INST ALLA TION/FRAMING W all & Ceiling Protection Using Flexible V ent Components Fireplace V ent Connection Using Rigid V ...

  • Napoleon Fireplaces GD82NT-T - page 3

    3 W415-0583 / B / 05.23.07 ALL SPECIFICA TIONS AND DESIGNS ARE SUBJECT T O CHANGE WITHOUT PRIOR NOTICE DUE T O ON-GOING PRODUCT IMPROVEMENTS. NAPOLEON® IS A REGISTERED TRADEMARK OF WOLF STEEL L TD. P A TENTS U.S. 5.303.693.801 - CAN. 2.073.41 1, 2.082.915. © WOLF STEEL L TD. N APOLEON® products are manuf actured under the strict Standard of the ...

  • Napoleon Fireplaces GD82NT-T - page 4

    4 W415-0583 / B / 05.23.07 Under extreme vent confi gurations, allow several minutes (5-15) for the fl ame to stabilize after ignition. Provide adequate ventilation and combustion air. Provide adequate accessibility clearance for servicing and operating the fi replace. Never obstruct the front opening of the fi replace. Objects placed in front ...

  • Napoleon Fireplaces GD82NT-T - page 5

    5 W415-0583 / B / 05.23.07 24" 16" 8" Do not use abrasive cleaners to clean glass. Buff lightly with a clean dry cloth. The glass is 3/16” ceramic glass available from your Napoleon® / Wolf Steel Ltd. dealer . DO NOT SUB- STITUTE MA TERIALS. Clean the glass after the fi rst 10 hours of operation with a recommended gas fi replace ...

  • Napoleon Fireplaces GD82NT-T - page 6

    6 W415-0583 / B / 05.23.07 VER TICAL RISE IN FEET V T FIGURE 4 when (H T ) < (V T ) Simple venting confi guration (only one 90° elbow) See graph to determine the required vertical rise V T for the required horizontal run H T . For vent confi gurations requiring more than one 90° elbow , the following formulas apply: F or mula 1: H T < V T ...

  • Napoleon Fireplaces GD82NT-T - page 7

    7 W415-0583 / B / 05.23.07 H 2 H 1 V 1 90° See graph to determine the required verti- cal rise V T for the required horizontal run H T . V 1 = V T = 6 ft H 1 = 3 ft H 2 = 5 ft H R = H 1 + H 2 = 3 + 5 = 8 ft H O = .0 3 (t wo 90° elbows - 90°) = .03(180° - 90°) = 2.7 ft H T = H R + H O = 8 + 2.7 = 10.7 ft H T + V T = 10.7 + 6 =16.7 Formula 1: H ...

  • Napoleon Fireplaces GD82NT-T - page 8

    8 W415-0583 / B / 05.23.07 REQUIRED VER TICAL RISE IN FEET V T HORIZONT AL VENT RUN PLUS OFFSET IN FEET H T when (H T ) < (V T ) FIGURE 9 For vent confi gurations requiring more than zero 90° elbow (top exit) or one 90° elbow (rear exit), the following formulas apply: F or mula 1: H T < V T F or mula 2: H T + V T < 40 feet See graph to ...

  • Napoleon Fireplaces GD82NT-T - page 9

    9 W415-0583 / B / 05.23.07 FIGURE 12 ...

  • Napoleon Fireplaces GD82NT-T - page 10

    10 W415-0583 / B / 05.23.07 This application occurs when venting through a roof. Installation kits for various roof pitches are available from your Napoleon® dealer . See Accessories to order the specifi c kit required. 1 . Determine the air terminal location, cut and frame 1 1½ inch openings in the ceiling and the roof to provide the minimum cl ...

  • Napoleon Fireplaces GD82NT-T - page 11

    11 W415-0583 / B / 05.23.07 1. Move the fi replace into position. 2. Fasten the roof support to the roof using the screws provided. The roof support is optional. In this case the venting is to be adequately supported using either an alternate method suitable to the authority having jurisdiction or the optional roof support. (Fig.a) 3. Stretch the ...

  • Napoleon Fireplaces GD82NT-T - page 12

    12 W415-0583 / B / 05.23.07 1. Move the fi replace into position. 2. Fasten the roof support to the roof using the screws pro- vided. The roof support is optional. In this case the venting is to be adequately supported using either an alternate method suitable to the authority having jurisdiction or the optional roof support. 3. Apply high tempera ...

  • Napoleon Fireplaces GD82NT-T - page 13

    13 W415-0583 / B / 05.23.07 FLUE COLLAR RESTRICTOR PLA TE TOP OF THE FIREBOX Proceed once the vent installation is complete. Note : All gas connections must be contained within the fi replace when complete. 1. The fi replace is designed to accept a ½” gas supply line. The fi replace is equipped with a ½” manual shut-off valve, and an 18” ...

  • Napoleon Fireplaces GD82NT-T - page 14

    14 W415-0583 / B / 05.23.07 WARNING F acing and/or fi nishing material must ne ver o verhang into the fi replace opening. Do not distor t or force the fr ame kit components. W hen using a rough fi nish materi- al (i.e.; stone), maintain a ¼” - ½” bor der from the fr aming components. NON-COMBUSTIBLE FINISHING MA TERIAL 59 3 / 8 " 21 3 ...

  • Napoleon Fireplaces GD82NT-T - page 15

    15 W415-0583 / B / 05.23.07 FIGURE 32 MANTLE CLEARANCES 0 34 7 8 9 11 13 12 5 6 7 10 12 H E I G H T M A N T L E MANTLE WIDTH Combustible mantle clearance can vary according to the mantle depth. Use the graph to help evaluate the clearance needed. Do NOT use the fi replace if any part has been under water . Call a qualified service technician IMMED ...

  • Napoleon Fireplaces GD82NT-T - page 16

    16 W415-0583 / B / 05.23.07 Optional Front Glass Door Latches Retainer Before the glass door can be removed, the optional front must be removed. The glass door is secured to the top front edge of the fi rebox. Pull the handles of the latches forward, then lift the hooks out from the slots in the door frame to release the top of the door . Next, pi ...

  • Napoleon Fireplaces GD82NT-T - page 17

    17 W415-0583 / B / 05.23.07 FIGURE 39 TOP EDGES BOTTOM EDGES Next, remove the 6 screws that secure the burner base. Once the gas has been disconnected, the burner train assembly will lift out. TOP SIDE OF ROCK CLUSTER 4. After rocks have been placed on the bowl, add the remaining rock by inserting the pin into the hole shown in Fig 40. FIGURE 40 CU ...

  • Napoleon Fireplaces GD82NT-T - page 18

    18 W415-0583 / B / 05.23.07 BOWL BURNER CURVED DECORA TIVE PA N E L BURNER BOTTOM BURNER BASE S E E - T H R U W I N D O W ELECTRODE BOX (AA Battery Required) CONTROL P ANEL CONTROL P ANEL BA TTER Y REPLACEMENT 1. Remove the optional front. (Instructions on Pg. 17) 2. T ilt the control panel forward allowing access to the electode box which is screw ...

  • Napoleon Fireplaces GD82NT-T - page 19

    19 W415-0583 / B / 05.23.07 Yo u r comes equipped with our Night Light TM . The light has been pre-wired and is controlled from the remote control. If in the event the lamp or lens needs to be replaced, follow the instructions below . Unplug the wire harness / transformer from the junction box inside the fi replace or turn off the electrical break ...

  • Napoleon Fireplaces GD82NT-T - page 20

    20 W415-0583 / B / 05.23.07 5. F AN SPEED SETTING This function controls the speed of the hot air circulating fan. T o change the fan speed, use the UP and Down button until the cursor (small triangle) is left of the fan icon. Set to one of 4 levels included or turned off (level 4 means full speed) 6. TIMER SETTING The Remote Control has a sleep fu ...

  • Napoleon Fireplaces GD82NT-T - page 21

    21 W415-0583 / B / 05.23.07 CHILD SAFETY LOCK-OUT This function is to deactivate con- trol button. The function is active when the lock icon is lit. T o activate this function press the ON / OFF button and within one second the UP key T o reactivate the remote control buttons follow the same sequence, press ON / OFF key and within one second press ...

  • Napoleon Fireplaces GD82NT-T - page 22

    22 W415-0583 / B / 05.23.07 DIP SWIT CH NUMBER (0 = ON / 1 = OFF) FIGURE 57 ...

  • Napoleon Fireplaces GD82NT-T - page 23

    23 W415-0583 / B / 05.23.07 A. This fi replace is equipped with a pilot which must be lit by hand while following these instructions exactly . B. Before operating smell all around the fi replace area for gas and next to the fl oor because some gas is heavier than air and will settle on the fl oor . C. Use only your hand to turn the gas control ...

  • Napoleon Fireplaces GD82NT-T - page 24

    24 W415-0583 / B / 05.23.07 AIR SHUTTER OPENING Closing the air shutter will cause a more yellow fl ame, but can lead to carboning. Opening the air shutter will cause a more blue fl ame, but can cause fl ame lifting from the burner ports. The fl ame may not appear yellow immediately; allow 15 to 30 minutes for the fi nal fl ame colour to be e ...

  • Napoleon Fireplaces GD82NT-T - page 25

    25 W415-0583 / B / 05.23.07 CONVERSION KIT This conversion kit shall be installed by a qualifi ed service agency in accordance with the manufacturer ’ s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instruction is not followed exactly , a fi re, explosion or production o ...

  • Napoleon Fireplaces GD82NT-T - page 26

    26 W415-0583 / B / 05.23.07 # P ART NO. DESCRIPTION 1 W135-0275 OUTER ROCKS 2 W135-0304 SINGLE ROCK 3 W135-0277 BOWL 4 GL-655 ROCK SET ASSEMBL Y 5 W565-0090 WIRE MESH 6* W390-0002 DOOR LA TCH ( EA ) 7 W725-0047 NA TURAL GAS V AL VE - MODULA TING 7 W725-0048 PROP ANE GAS V AL VE - MODULA TING 8* W455-0019 NA TURAL GAS ORIFICE #43 8* W455-0003 PROP A ...

  • Napoleon Fireplaces GD82NT-T - page 27

    27 W415-0583 / B / 05.23.07 35 34 16 48 46 45 22 19 28 18 20 AUX ON 0:00 00 ON/OFF FEATURE SELECT 21 25 23 24 26 1 2 17 4 11 9 13 12 10 54 40 41 42 43 55 39 3 5 ...

  • Napoleon Fireplaces GD82NT-T - page 28

    28 W415-0583 / B / 05.23.07 White / grey film forms. Sulphur from fuel is being deposited on glass, logs or combustion chamber sur- faces. - clean the glass with a gas fi replace glass cleaner . DO NOT CLEAN GLASS WHEN HOT . If deposits are not cleaned off regularly , the glass may become per- manently marked. Carbon is being de- posited on glass, ...

  • Napoleon Fireplaces GD82NT-T - page 29

    29 W415-0583 / B / 05.23.07 Remote wall switch is in “OFF” position; main burner comes on when gas knob is turned to “ON” position. W all switch is mounted upside down - reverse. Faulty valve. - replace. - replace. Remote wall switch is ground- ing. - check for ground (short); repair ground or replace wire. Remote wall switch wire is ground ...

  • Napoleon Fireplaces GD82NT-T - page 30

    30 W415-0583 / B / 05.23.07 Fireplace Service History This fireplace must be serviced annually depending on usage DA TE DEALER NAME SERVICE TECHNICIAN NAME SERVICE PERFORMANCE SPECIAL CONCERNS ...

  • Napoleon Fireplaces GD82NT-T - page 31

    31 W415-0583 / B / 05.23.07 NOTES ...

Manufacturer Napoleon Fireplaces Category Fire Pit

Documents that we receive from a manufacturer of a Napoleon Fireplaces GD82NT-T can be divided into several groups. They are, among others:
- Napoleon Fireplaces technical drawings
- GD82NT-T manuals
- Napoleon Fireplaces product data sheets
- information booklets
- or energy labels Napoleon Fireplaces GD82NT-T
All of them are important, but the most important information from the point of view of use of the device are in the user manual Napoleon Fireplaces GD82NT-T.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Napoleon Fireplaces GD82NT-T, service manual, brief instructions and user manuals Napoleon Fireplaces GD82NT-T. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Napoleon Fireplaces GD82NT-T.

A complete manual for the device Napoleon Fireplaces GD82NT-T, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Napoleon Fireplaces GD82NT-T by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Napoleon Fireplaces GD82NT-T.

A complete Napoleon Fireplaces manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Napoleon Fireplaces GD82NT-T - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Napoleon Fireplaces GD82NT-T, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Napoleon Fireplaces GD82NT-T, that we can find in the current document
3. Tips how to use the basic functions of the device Napoleon Fireplaces GD82NT-T - which should help us in our first steps of using Napoleon Fireplaces GD82NT-T
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Napoleon Fireplaces GD82NT-T
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Napoleon Fireplaces GD82NT-T in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Napoleon Fireplaces GD82NT-T?

Use the form below

If you did not solve your problem by using a manual Napoleon Fireplaces GD82NT-T, ask a question using the form below. If a user had a similar problem with Napoleon Fireplaces GD82NT-T it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)