Manual Ingersoll-Rand 4581740

48 pages 2.1 mb
Download

Go to site of 48

Summary
  • Ingersoll-Rand 4581740 - page 1

    Insight IC-D and IC-M DC Elec tric T ool C ontr oller U ser Manual Sav e T hese Instruc tions 04581740 Edition 2 December 2007 ...

  • Ingersoll-Rand 4581740 - page 2

    2 04581740_ed2 T able of C ont ents Sec tion 1 – Introduction - 5 1.1 Contr ol P anel ................................................................................................................................................................................... 5 1.1.1 Navigation Keypad ........................................................ ...

  • Ingersoll-Rand 4581740 - page 3

    04581740_ed2 3 3.3 System Setup ............................................................................................................................................................................... 20 3.3.1 P asswor ds ......................................................................................................................... ...

  • Ingersoll-Rand 4581740 - page 4

    4 04581740_ed2 Appendix 1 – Sy stem Specs and Spare P ar ts - 38 Insight T echnical Specications ..................................................................................................................................................... 38 Pinout T ables ................................................................................ ...

  • Ingersoll-Rand 4581740 - page 5

    04581740_ed2 5 Sec tion 1 – Introduction The Insight IC-D and IC-M F astening Systems are electronic tightening con trollers that can be prog rammed to operat e Ingersoll Rand QE- and QM-series spindles, depending on the model, to perform repetitive fastening operations . The spindles may be individual hand-held spindles, or sev eral may be mount ...

  • Ingersoll-Rand 4581740 - page 6

    6 04581740_ed2 Enter Key Escape Key Expand Key Directional Arrow Keys F igure 2 - Directional Keypad A screen element containing the Expand symbol indica tes the element can be opened to r eveal additional options. Pr essing the Expand key located in the center of the na vigation keypad will open the element and display the options . Y ou can then ...

  • Ingersoll-Rand 4581740 - page 7

    04581740_ed2 7 1.1.4 Screen Elements All the dier ent screens that can appear on the Insight IC-D display ha ve certain design elements in common. These design elements, called scr een elements, ar e shown in the graphics below . In actual operation, you use the arrow keys on the Naviga tional keypad to navigate the cursor t o the individual scr ...

  • Ingersoll-Rand 4581740 - page 8

    8 04581740_ed2 1.1.5 Using Menus and Screens 1. Push the corr esponding button to select the menu section you want to view . Ther e are f our sets of menu screens from which you can select. The selec tion buttons for these f our menus are locat ed above the display scr een in the upper part of the front panel. Run The Run screen displa ys fastening ...

  • Ingersoll-Rand 4581740 - page 9

    04581740_ed2 9 Sec tion 2 – Installation 2.1 Mounting Bolt the Insight controller enclosure t o a suitable rigid sur face near the assembly area using the mounting brackets on the back of the enclosure. See the dra wings below for dimensions , information on bracket hole spacing , recommended mounting bolts, door opening clearanc es, and other mo ...

  • Ingersoll-Rand 4581740 - page 10

    10 04581740_ed2 F igure 7 - Side and Back Dimensional Drawings 2.2 Elec trical Connection Make sure the Main Po wer Swit ch is in the O position. Insight controllers are a vailable with various power c ord options. Some options include a pigtail pow er cable, and the user must supply the correct power cor d connector . Review the elec trical cir ...

  • Ingersoll-Rand 4581740 - page 11

    04581740_ed2 11 2.3 A ttaching P eripheral I/O De vices T o remov e the I/O cover , rst remov e the retaining screw on the right -hand side of the cover , and then press in the locking tab below the screw and lift up the cover . Serial Port Rotar y Switches (CA2 Addr ess) T ermination Resistor Switch USB Port P owerhead Synchr onization Bus Ethe ...

  • Ingersoll-Rand 4581740 - page 12

    12 04581740_ed2 2.3.1 Activating an Input All input signals operate a t 24VDC. The Return for the 24V sig nal must be connected to C OM IN for each input bank. It is recommended that y ou use the internal 24VDC located at the t erminals marked 24VDC OUT +/-. Switch the 24VDC back to the desired input signal (FORW ARD , REVERSE, FREE SPEED , etc.). ...

  • Ingersoll-Rand 4581740 - page 13

    04581740_ed2 13 2.3.4 PL C Connection and S etup NO TE: All connections to a PL C are made via the Insight’ s terminal blocks, ex cept data collection. Data collection is done via the serial Fieldbus and/or E thernet por ts. F or data collection, follo w the procedur es for setup via the serial or Ethernet por t. T o connec t a PL C to the t ermi ...

  • Ingersoll-Rand 4581740 - page 14

    14 04581740_ed2 2.4.2 Bar Code C onnection and Setup Description The bar code function allows the Insight IC contr oller to be connected to any serial ASCII bar code scanner or E thernet bar code scanner . Each spindle can be equipped with its own scanner or , in the case of a powerhead, one scanner can be assigned to the pow erhead. The bar code f ...

  • Ingersoll-Rand 4581740 - page 15

    04581740_ed2 15 2.5.1 Single Spindle Operation If the E-stop is being used, JP21 pin 2 (relay c oil (-)) is routed to one c ontact of a remote (normally closed) SPST palm button switch (PBS). The switch ’ s other contact is routed back to JP21 pin 4. JP21 pin 1 r emains connected to JP21 pin 3. If an emergency occurs the spindle operator can depr ...

  • Ingersoll-Rand 4581740 - page 16

    16 04581740_ed2 2.5.3 E-Stop Not P resent If E-stop is not being used, the E-stop rela y must still be energized t o permit normal operation. This is ac complished by connecting JP21 pin 1 to JP21 pin 3 and JP21 pin 2 to JP21 pin 4. This allows the module’ s internal 24 VDC to energize the relay . The wiring is the same regardless of single or mu ...

  • Ingersoll-Rand 4581740 - page 17

    04581740_ed2 17 2.7 P ow erhead Setup A group of Insight units synchroniz ed together to perform a multiple bolt tightening task is called a Po werhead . If you are arranging a series of Insight contr ollers together in this way , you must link them in a “ daisy chain ” fashion to create a Po werhead S ynchronization Bus . These can comprise up ...

  • Ingersoll-Rand 4581740 - page 18

    18 04581740_ed2 Sec tion 3 – Progr amming the IC-D 3.1 Setup Menu The Setup menu and its sub-menus are used to program tigh tening strategies and t o set a broad variety of important system parameters . Basic tightening strat egies are cr eated in the Setup menu. In addition to strateg ies, you can use the Setup menu to set many basic system par ...

  • Ingersoll-Rand 4581740 - page 19

    04581740_ed2 19 F igure 17 - Quick Setup Screen T o complete the parameters in the Quick Setup sub-menu: 1. Pr ess the Setup menu button, then press Enter to choose the rst sub-menu, Quick Setup . 2. Use the arrow key s to move t o one of the eight lines representing C ongurations 1 thr ough 8. 3. Pr ess Enter to bring up the Step 2, the r ...

  • Ingersoll-Rand 4581740 - page 20

    20 04581740_ed2 If the Gang Count is successfully completed , in addition to displaying “Gang Complete ” on the screen, the controller provides a gang complet e output signal on the spindle ’ s I/O connector . There ar e two ways to r eset the Gang Count. 1. Use the dedicated r eset palm switch on the Gang Reset Input. 2. While on the Run Mai ...

  • Ingersoll-Rand 4581740 - page 21

    04581740_ed2 21 3.3.3 Job Number and CAN Address The Job Number and CAN (C ontroller A rea Network) A ddress paramet ers found at the top of the S yst em Setup screen are used t o set a Location ID f or a particular I nsight controller . The L ocation ID is used as a unique identier f or each unit on the network. The Job Number is a 4-digit entr ...

  • Ingersoll-Rand 4581740 - page 22

    22 04581740_ed2 F igure 19 - Spindle Setup Screen The rst parameter , T ransducer Range ( TR), allows you to enter a desir ed TR value in Nm to calibrat e the torque output of the connected spindle. The second parameter is A ngle Constan t . This is wher e you set a value to calibra te the angle output of the spindle. Cong Selection is the pa ...

  • Ingersoll-Rand 4581740 - page 23

    04581740_ed2 23 When T ube Nut 1 is selected, the spindle operates in tube nut rev erse when the momentary position of the switch is activated. No trigger press is nec essary to operate the spindle in tube nut reverse in this mode . When the momentary switch is released, the spindle stops, and it is then r eady for f orward operation. When T ube Nu ...

  • Ingersoll-Rand 4581740 - page 24

    24 04581740_ed2 3.5.6 Host Addr ess The Host Addr ess is only used when Host Data Out has been selected in the Protoc ol parameter . F or more inf ormation on applying the Serial Setup screen to par ticular devises, see section 2.4.1 Print er Connections and Setup. 3.6 PC C onnec tion When a PC is connected to the Insight controller via the E thern ...

  • Ingersoll-Rand 4581740 - page 25

    04581740_ed2 25 3.7 USB Stor age Device Da ta T ransf er 3.7.1 Inser tion A USB Storage device or key can be inserted into the contr oller at either run time or prior to booting. Such a devic e is conv enient for transf erring setup les to the controller , or for r etrieving data les from it. F or instance, you can copy an entire setup to an ...

  • Ingersoll-Rand 4581740 - page 26

    26 04581740_ed2 Sec tion 4 – Operating the IC-D S y stem 4.1 Introduction This section provides the information tha t you need to operat e the Insight controller . At this point, the syst em should be properly installed and progr ammed. The Main screen from the Run menu is where syst em operation takes place. It is made up of three parts: the Con ...

  • Ingersoll-Rand 4581740 - page 27

    04581740_ed2 27 4.3 Monitoring Operation 4.3.1 T orque and Angle V alues The middle section of the Run Main screen on the IC-D displays tor que and angle information f or each tightening operation. The larger value is the primar y one, and it reects the strategy tha t applies to the selected Conguration. In the cutout of the screen shown belo ...

  • Ingersoll-Rand 4581740 - page 28

    28 04581740_ed2 4.4 Message Area The Message Box a t the bottom of the Main screen summarizes syst em status and provides warnings and alarms on the IC-D . On the IC-M LED display , only the Event Code number is display ed in the event of an error . See Event C ode T able on page 44 for a listing of these events . 4.5 Stats and P M Alarms 4.5.1 Sta ...

  • Ingersoll-Rand 4581740 - page 29

    04581740_ed2 29 Sec tion 5 – Qualit y C ontr ol 5.1 Statistics Menu The Statistics menu allow s you to acc ess a variety of statistical data on completed fastenings . F or example, you can view actual fastening parameters, as w ell as statistical calculations, and can compar e them to target values . This section discusses the four Statistics sub ...

  • Ingersoll-Rand 4581740 - page 30

    30 04581740_ed2 The SD C ode column on the Cy cle Log show s the Shutdown C ode for each cycle. The shutdown code is a 2-digit code that gives the r eason why the cycle stopped. See a list of the shutdo wn codes in the table below . Shutdown Code # Description 0 Normal Completion of C ycle 1 Handheld – T rigger released before cycle was complete ...

  • Ingersoll-Rand 4581740 - page 31

    04581740_ed2 31 Shutdown Code # Description 121 Po werhead – MCE step sequence err or 122 Po werhead – MCE software fault 123 Po werhead – MCE IGBT fault 124 Po werhead – MCE low bus v oltage fault 125 Po werhead – MCE hardwar e watchdog fault 126 Po werhead – MCE calibration failed due to EEPROM mode 127 Po werhead – MCE calibration ...

  • Ingersoll-Rand 4581740 - page 32

    32 04581740_ed2 2. On the Statistics menu , select Spindle Statistics and press En ter . 3. Select the dropdown Congur ation box and pr ess the Expand button to view a list of the av ailable Congurations with statistics that can be viewed . 4. Select the Conguration you wish to use and pr ess Enter . 5. Scroll through the various parameter ...

  • Ingersoll-Rand 4581740 - page 33

    04581740_ed2 33 The nal selection on the Statistics menu is P ow erhead Stats . This screen provides useful data when the IC-D is part of a powerhead Congur ation.These statistics ar e only available when the contr oller is a powerhead master (the con troller can2 rotary switches must be set to 01). F igure 29 - P owerhead Stats Note that the ...

  • Ingersoll-Rand 4581740 - page 34

    34 04581740_ed2 Sec tion 6 – Diagnostics and T roubleshooting 6.1 Diagnostics Menu The Diagnostics menu allows y ou to check the over all system health of the Insight IC-D . This func tionality also diagnoses system pr oblems. This section discusses the four Diagnostics sub-menu screens, including: Sy stem T est Display Inputs Set Outputs T ool T ...

  • Ingersoll-Rand 4581740 - page 35

    04581740_ed2 35 T est Data Element Explanation T ool Motor temperatur e Checks motor temperatur e and reports P ASS or F AIL. Amplier oset MCE’ s oset voltage (as % of Shunt C al voltage). Shunt calibration F ront-end electronics gain (as % of ideal Shunt Cal voltage). Sine Oset The oset in A/D coun ts of the resolver sine analog i ...

  • Ingersoll-Rand 4581740 - page 36

    36 04581740_ed2 F igure 33 - Discrete Outputs Menu T o access and use Set Outputs : 1. Pr ess the Diag button on the Insight controller . 2. On the Diagnostics menu, select Set Outputs and press Enter . 3. Scroll through the listed outputs using the arr ow keys to the Output you wish t o test. 4. Pr ess the Enter key to send an output signal fr om ...

  • Ingersoll-Rand 4581740 - page 37

    04581740_ed2 37 T o access and use T ool T est : 1. Pr ess the Diag button on the Insight controller . 2. On the Diagnostics menu , select T ool T est and press En ter . 3. A pop-up message warns you that running the test interrupts spindle operations . Pr ess Enter to con tinue. 4. F or a xtured spindle, use the arrow key s to the Start T ool b ...

  • Ingersoll-Rand 4581740 - page 38

    38 04581740_ed2 Appendix 1 – S y stem Specs and Spar e Parts Insight T echnical Specications The specications for the Insight IC Tightening Syst em are shown belo w . Measurement Ac curacy ±0.2% of torque full scale ±1 count of angle (degr ees) Measurement Resolution ±0.025% of torque full scale T orque T ransducer Bridge Excitation ±5V ...

  • Ingersoll-Rand 4581740 - page 39

    04581740_ed2 39 Outputs Output Behavior Block # Pin # Spindle In c ycle 2 O-1 Cy cle Complete 2 O -2 Accept 2 O-3 T orque High 2 O -4 T orque Lo w 2 O -5 Angle High 2 O -6 Angle Low 2 O -7 Gang Complete 2 O-8 Recommended Spar e Parts List See the illustrations following the P ar ts List. Detail Number Part Number Description 04581740 IC-D , IC-M Op ...

  • Ingersoll-Rand 4581740 - page 40

    40 04581740_ed2 Outside the Co ver 6 2 3 8 ...

  • Ingersoll-Rand 4581740 - page 41

    04581740_ed2 41 Inside the Co v er 1 4 5 7 ...

  • Ingersoll-Rand 4581740 - page 42

    42 04581740_ed2 Side 9 ...

  • Ingersoll-Rand 4581740 - page 43

    04581740_ed2 43 Appendix 2 – E v ent C odes The follo wing table lists the Event C odes for the IC-D and IC-M. Below is an explanation of table c olumns. Ev ent C ode Explanation Ev ent Code This is the event c ode number . On an IC-M controller , the code is displayed on the screen as “E” and then the code number , for example, E002. F or a ...

  • Ingersoll-Rand 4581740 - page 44

    44 04581740_ed2 Ev ent Code Description/C ondition Critical Error Action Required/Explanation Display on D , M GUI USB Ev ents 081 to 100 081 Not enough space to sav e controller data to USB key No Remove excess les f or USB key D , M 082 Time out while saving data t o the USB Disk No Check that USB key is approv ed to function with controller D ...

  • Ingersoll-Rand 4581740 - page 45

    04581740_ed2 45 Inde x A Activating an Input 12 Attaching P eripheral Devices 11 Attaching The Spindles 11 Auto Increment 20 B Backspace Key 6 Bar Code Active Mode 14 Compatibility W ith Other Functions 14 Auto Increment 14 Gang Count 14 P owerhead 14 Connection and Setup 14 Description 14 Operation 14 P assive Mode 14 Button 7 C Check Box 7 Circui ...

  • Ingersoll-Rand 4581740 - page 46

    46 04581740_ed2 Q Quality Control 29 Quick Setup screen 18 R Radio Button 7 Receiving an Output 12 Run Menu Statistic Summary Screen 31 Run Menus Cy cle Log Screen 29 S Screen Elements 7 Serial Port 16 Serial Printer 13 Setup 23 Shutdown Code 30 Spare P arts List 39 Specications 38 Spindle Operation 22 Spindles Attaching 11 Startup 17 Statistic ...

  • Ingersoll-Rand 4581740 - page 47

    04581740_ed2 47 Notes: ...

  • Ingersoll-Rand 4581740 - page 48

    ww w .ir tools.com © 2007 Ingersoll Rand Compan y ...

Manufacturer Ingersoll-Rand Category Saw

Documents that we receive from a manufacturer of a Ingersoll-Rand 4581740 can be divided into several groups. They are, among others:
- Ingersoll-Rand technical drawings
- 4581740 manuals
- Ingersoll-Rand product data sheets
- information booklets
- or energy labels Ingersoll-Rand 4581740
All of them are important, but the most important information from the point of view of use of the device are in the user manual Ingersoll-Rand 4581740.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Ingersoll-Rand 4581740, service manual, brief instructions and user manuals Ingersoll-Rand 4581740. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Ingersoll-Rand 4581740.

A complete manual for the device Ingersoll-Rand 4581740, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Ingersoll-Rand 4581740 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Ingersoll-Rand 4581740.

A complete Ingersoll-Rand manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Ingersoll-Rand 4581740 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Ingersoll-Rand 4581740, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Ingersoll-Rand 4581740, that we can find in the current document
3. Tips how to use the basic functions of the device Ingersoll-Rand 4581740 - which should help us in our first steps of using Ingersoll-Rand 4581740
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Ingersoll-Rand 4581740
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Ingersoll-Rand 4581740 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Ingersoll-Rand 4581740?

Use the form below

If you did not solve your problem by using a manual Ingersoll-Rand 4581740, ask a question using the form below. If a user had a similar problem with Ingersoll-Rand 4581740 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)