    LG Room Air Conditioner SERVICE MANUAL LG MODELS: LAN121CNM (ASNC121ERH0) LAU121CNM (ASUC121EUH0) LA121HPMI (ASNH121ERH0) LA121HPMO (ASUH121EUH0) LAN121HNM (ASNH121ERH0) LAU121HNM (ASUH121EUH0) LA121CPMI (ASNC121ERH0) LA121CPMO (ASUC121EUH0) CAUTION website http://www.lgservice.com • BEFORE SERVICING THE UNIT, READ THE SAFETY PRECAUTIONS IN THIS ...

  • LG Electronics LAU121CNM - page 2

    2 Room Air Conditioner Air Conditioner Ser vice Manual T ABLE OF CONTENTS Safety Precautions ..........................................................................................................................................3 Dimensions .......................................................................................................... ...

  • LG Electronics LAU121CNM - page 3

    Ser vice Manual 3 Saf ety Precautions Safety Precautions T o pre v ent injury to the user or other people and proper ty damage, the f ollowing instructions must be f ollow ed. ■ Incorrect operation due to ignoring instruction will cause har m or damage. The seriousness is classified by the f ollowing indications. ■ Meanings of symbols used in t ...

  • LG Electronics LAU121CNM - page 4

    4 Room Air Conditioner Saf ety Precautions ■ Operation Be cautious when unpacking and installing the product. • Shape edges could cause injur y . Be especially careful of the shar p edges. For installation, alwa ys contact the dealer or an A uthorized Service Center . • There is risk of fire, electric shock, e xplosion, or injur y . Do not in ...

  • LG Electronics LAU121CNM - page 5

    Ser vice Manual 5 Saf ety Precautions Do not place a heater or other appliances near the power cable. • There is risk of fire, f ailure of the product, and/or electric shock. Do not let the air conditioner run for a long time when the humidi- ty is very high and a door or a window is left open. • Moisture ma y condense and wet or damage fur nis ...

  • LG Electronics LAU121CNM - page 6

    6 Room Air Conditioner Saf ety Precautions V entilate the product fr om time to time when operating it togeth- er with a stove, etc. • There is risk of fire or electr ical shock. Unplug the appliance before performing c leaning or mainte- nance. • There is risk of electr ic shock. When the product is not be used for a long time disconnect the p ...

  • LG Electronics LAU121CNM - page 7

    Ser vice Manual 7 ■ Operation Saf ety Precautions Do not install the product where the noise or hot air from the out- door unit could damage the neighborhoods. • It ma y cause a prob lem f or your neighbors. Use two or more people to lift and transport the air conditioner • A v oid personal injury . Do not install the product where it will be ...

  • LG Electronics LAU121CNM - page 8

    8 Room Air Conditioner Dimensions Do not rechar ge or disassemble the batteries. Do not dispose of batteries in a fire. • They ma y burn or explode . If the liquid from the batteries gets onto y our skin or clothes, wash it well with c lean water . Do not use the remote if the batteries have leaked. • The chemicals in batteries could cause burn ...

  • LG Electronics LAU121CNM - page 9

    Ser vice Manual 9 Dimensions Dimensions Installation plate D H W Indoor Unit This symbol aler ts y ou to the risk of electric shoc k. This symbol aler ts y ou to hazar ds that could cause harm to the air conditioner . This symbol indicates special notes. NOTICE Symbols Used in this Manual W mm 915(36.0) H mm 282(11.1) D mm 165(6.5) Model Dimension ...

  • LG Electronics LAU121CNM - page 10

    10 Room Air Conditioner Dimensions Outdoor Unit 1. 12k W L2 L3 L1 D H L4 L5 Gas side (3-way valve) Liquid side (2-way valve) MODEL 12k DIM unit W mm(inch) 770(30.3) H mm(inch) 540(21.3) D mm(inch) 245(9.6) L1 mm(inch) 287(11.3) L2 mm(inch) 64(2.5) L3 mm(inch) 518(20.4) L4 mm(inch) 10(0.4) L5 mm(inch) 100(3.9) ...

  • LG Electronics LAU121CNM - page 11

    Ser vice Manual 11 Introduction Intr oduction This symbol alerts you to the risk of electric shoc k. This symbol alerts you to hazar ds that may cause harm to the air condi- tioner . This symbol indicates special notes. NOTICE Symbols Used In This Manual Features Air Intake Vents Air Outlet Vents Connecting Wires Piping Drain Hose Base Plate Air Ou ...

  • LG Electronics LAU121CNM - page 12

    12 Room Air Conditioner Installation Figure Figure Name Screw driver Electric Drill Measuring Tape, Knife Hole Core Drill Spanner Torque wrench Ohmmeter Hexagonal wrench Ammeter Gas Leak Detector Thermometer, Level Flaring Tool Set Name Type "A" screw and plastic anchor Type "B" screw Remote Control Holder Installation plate Ins ...

  • LG Electronics LAU121CNM - page 13

    Ser vice Manual 13 Installation Installation Map Installation parts you should purchase. Vinyl tape (Wide) • Apply after carrying out a drainage test. • To carry out the drainage test, remove the air filters and pour water into the heat exchanger. Saddle Forced Operation Button Gas side piping (Optional Parts) Liquid side piping (Optional Parts ...

  • LG Electronics LAU121CNM - page 14

    14 Room Air Conditioner 1. Check the quality label on the indoor and outdoor unit. 2. Make certain that the refr igerant is R-410A. THIS PRODUCT CONT AINS R-410A REFRIGERANT 1) Diff erent compressor oil - R-410A(P olyol ester) / R-22(Mineral). - Do not mix the e xisting mineral oil. - Do not apply used pipe, tools and gauges co v ered with the e xi ...

  • LG Electronics LAU121CNM - page 15

    Ser vice Manual 15 Outdoor unit 1. If an a wning is built o v er the unit to pre v ent direct sunlight or rain e xposure , make sure that heat radiation from the condenser is not restricted. 2. Ensure that the space around the bac k and sides is more than 30cm(11.8in). The front of the unit should hav e more than 70cm(27.6in) of space. 3. Do not pl ...

  • LG Electronics LAU121CNM - page 16

    16 Room Air Conditioner Piping Length and Elev ation 12k Ø 12.7(1/2") Ø 6.35(1/4") 7.5(25) 7.5(25) 15(49) 20(0.22) Pipe Size Capacity (Btu/h) Suction Evap Standard Length m(ft) Max. Elevation B m(ft) Max. length A m(ft) Additional Refrigerant g/m(oz/ft) In case more than 5m(16.4ft) Outdoor unit Indoor unit A B Outdoor unit Indoor unit A ...

  • LG Electronics LAU121CNM - page 17

    Ser vice Manual 17 The wall y ou select should be strong and solid enough to pre v ent vibration 1. Mount the installation plate on the wall with type "A" screws . If mounting the unit on a concrete wall, use anchor bolts . • Mount the installation plate horizontally b y aligning the centerline using a lev el. How to Mount Installation ...

  • LG Electronics LAU121CNM - page 18

    18 Room Air Conditioner Flaring W ork Cut the pipes and the cable. 1. Use the piping kit accessor y or the pipes purchased locally . 2. Measure the distance between the indoor and the out- door unit. 3. Cut the pipes a little longer than measured distance. 4. Cut the cable 1.5m(59.1in) longer than the pipe length. Burrs remo v al 1. Completely remo ...

  • LG Electronics LAU121CNM - page 19

    Ser vice Manual 19 Indoor 1. Prepare the indoor unit's piping and drain hose f or installation through the w all. 2. Remo ve the plastic tubing retainer(see the illus- tration b y) and pull the tubing and drain hose aw a y from chassis. 3. Replace only the plastic tubing holder 1, not the holder 2 in the original position. Route the indoor tub ...

  • LG Electronics LAU121CNM - page 20

    20 Room Air Conditioner Wrap the insulation material around the connecting portion. • Ov erlap the connection pipe insulation mater ial and the indoor unit pipe insulation material. Bind them together with vinyl tape so that there is no gap . Route the indoor tubing and the drain hose to the required piping hole position. Plastic bands Insulation ...

  • LG Electronics LAU121CNM - page 21

    Ser vice Manual 21 Insert the connecting cable into the indoor unit. • Don't connect the cable to the indoor unit. • Make a small loop with the cab le f or easy con- nection later . T ape the drain hose and the connecting cable. • Connecting cable Connecting the pipings to the indoor unit and the drain hose to drain pipe. • Put a coupl ...

  • LG Electronics LAU121CNM - page 22

    22 Room Air Conditioner Reroute the pipings and the drain hose across the bac k of the c hassis. Reroute the pipings and the drain hose across the bac k of the c hassis. Drain hose Vinyl tape(narrow) Pipe Wrap with vinyl tape(wide) • Bundle the piping and drain hose together b y wrapping them with cloth tape o ver the r ange within which they fit ...

  • LG Electronics LAU121CNM - page 23

    Ser vice Manual 23 Installation Inf or mation. F or left piping. F ollo w the instruction below . Correct case • Press on the upper side of clamp and unf old the tubing to downw ard slowly . Incorrect case • F ollowing bending type from right to left ma y cause damage to the tubing. Installation ...

  • LG Electronics LAU121CNM - page 24

    24 Room Air Conditioner Put a couple drops of refrigerant oil on the face of the flare before assemb ling taking care not to add an y contaminants. Align the center of the pipings and suffi- ciently tighten the flare n ut by hand. • The drain hose can be connected at tw o diff erent positions. Use the most con v enient position and, if necessar y ...

  • LG Electronics LAU121CNM - page 25

    Ser vice Manual 25 Connection of The Cable 1 Indoor Unit Outdoor Unit 2 3 4 1 2 3 4 5 6 G To branch circuit Ground P ower supply a L1 * L2 Connecting cable(Low v oltage) b T er minal (4P) T er minal (6P) Outdoor unit Wiring Diagram T er minal bloc k Over 5mm (0.2") Cov er control Conduit panel Connecting cable P o wer supply cord * L1 is neutr ...

  • LG Electronics LAU121CNM - page 26

    26 Room Air Conditioner After the confir mation of the abov e conditions , prepare the wiring as follo ws: 1) Never fail to ha ve an individual po wer cir cuit specificall y f or the air conditioner . As for the method of wiring, be guided by the cir cuit diagram posted on the inside of contr ol co ver . 2) The screw whic h fasten the wiring in the ...

  • LG Electronics LAU121CNM - page 27

    Ser vice Manual 27 Chec king The Drainage • P our a glass of water on the drain pan. • Ensure the water flo ws through the drain hose of the indoor unit without an y leakage and goes out the drain e xit. Drain piping • The drain hose should point do wnward f or easy drain flo w . Drain pan Drain hose Leakage checking Connecting area drain hos ...

  • LG Electronics LAU121CNM - page 28

    28 Room Air Conditioner Forming The Piping Form the piping by wrapping the connect- ing portion of the indoor unit with insula- tion material and secure it with two kinds of vinyl tapes. • If you w ant to connect an additional drain hose , the end of the drain outlet should be routed abov e the ground. Secure the dr ain hose appro- priately . In ...

  • LG Electronics LAU121CNM - page 29

    Ser vice Manual 29 Air Purging Air purging With V acuum Pump Lo Hi Indoor unit Outdoor unit Manifold valve Charge hose Nitrogen gas cylinder(in vertical standing position) Pressure gauge Air and moisture remaining in the refrigerant system hav e undesirab le eff ects as indicated belo w . • Pressure in the system rises. • Operating current rise ...

  • LG Electronics LAU121CNM - page 30

    30 Room Air Conditioner Ev acuation • Connect the charge hose end described in the preceding steps to the v acuum pump to e vacuate the tubing and indoor unit. Confir m the "Lo" knob of the manif old v alv e is open. Then, run the vacuum pump . The operation time f or e v acuation v aries with tub- ing length and capacity of the pump . ...

  • LG Electronics LAU121CNM - page 31

    Ser vice Manual 31 Charging ■ Each outdoor unit is f actor y charged (nameplate charge) f or the e v aporator as well as a 7.5m(25ft) line set. Any time a line set is used either shor ter or longer then the nominal 7.5m(25ft) line set length the refrigerant charge has to be adjusted. ■ Whether the line set is made shor ter or longer you must ad ...

  • LG Electronics LAU121CNM - page 32

    32 Room Air Conditioner Outside ambient TEMP. The pressure of the gas side service valve 95 ° F(35 ° C) 8.5~9.5kg/cm 2 G(120~135 P.S.I.G.) Settlement of outdoor unit ■ Anchor the outdoor unit with a bolt and nut( ø 10mm(0.39in) tightly and horizontally on a concrete or rigid mount. ■ When installing on the wall, roof or rooftop , anchor the ...

  • LG Electronics LAU121CNM - page 33

    Ser vice Manual 33 Operation Function of Contr ols Operation • DISPLA Y 1) C/O Model Operation Indicator • ON while in appliance operation, OFF while in appliance pause . • Flashing while in disconnection or shor t in Ther mistor . (3 sec off / 0.5 sec on) Timer Indicator • ON while in timer mode (on/off), OFF when timer mode is completed o ...

  • LG Electronics LAU121CNM - page 34

    34 Room Air Conditioner Operation • While in compressor off , the indoor f an repeats lo w airflow speed and pause . • While the intak e air temp is between compressor on temp . and compressor off temp ., 10-min dehu- midification operation and 4-min compressor off repeat. Compressor ON T emp . ➲ Setting T emp+0.5 ° C Compressor OFF T emp . ...

  • LG Electronics LAU121CNM - page 35

    Ser vice Manual 35 Operation ■ Airflow Speed Selection • The airflo w speed of the indoor f an is set to high, medium, low , or chaos (auto) by the input of the airflow speed selection k e y on the remote control. ■ Sleep Timer Operation • When the sleep time is reached after <1,2,3,4,5,6,7,0(cancel) hr> is input b y the remote contro ...

  • LG Electronics LAU121CNM - page 36

    36 Room Air Conditioner Operation ■ Forced operation • Operation procedures when the remote control can't be used. • The operation will be star ted if the pow er button is pressed. • If you w ant to stop operation, re-press the b utton. • While in f orced operation, the k e y input by the remote control has no eff ect and the buzzer ...

  • LG Electronics LAU121CNM - page 37

    Ser vice Manual 37 Self-diagnosis Function Operation Displa y Function 1. Heating Model 2. Cooling Model • Cooling, Soft Dry, Fan, Heating • Cooling, Soft Dry, Fan • Hot-start, Deice Operation Indicator Deicer Indicator Operation Indicator Compressor on Indicator 3sec 3sec 3sec (once) Error Code 1 Error Displa y LED (Indoor body operation LED ...

  • LG Electronics LAU121CNM - page 38

    38 Room Air Conditioner Remote Contr ol Operations Operation The controls will look like the f ollowing. 1. ST ART/ST OP BUTT ON Operation star ts when this button is pressed and stops when the button is pressed again. 2. OPERA TION MODE SELECTION BUTT ON Used to select the operation mode . 3. ROOM TEMPERA TURE SETTING BUTT ONS Used to select the r ...

  • LG Electronics LAU121CNM - page 39

    Ser vice Manual 39 Disassembly Disassembl y Indoor Unit Disconnect the unit from power supply before mak- ing any checks. Be sure the power switch is set to “ OFF ” . To remove the Grille from the Chassis. • Open the front panel as shown, and Remove the Securing screws. • Set the up-and-down air discharge louver to open position (horizontal ...

  • LG Electronics LAU121CNM - page 40

    40 Room Air Conditioner Disassembly 2. T o remove the Control Bo x. • Remove securing screws. • Pull the control box out from the chassis carefully. 3. T o remove the Dischar ge Grille . • Unhook the discharge grille and pull the discharge grille out from the chassis carefully. 4. T o remove the Evaporator . • Remove 3 screws securing the e ...

  • LG Electronics LAU121CNM - page 41

    Ser vice Manual 41 Disassembly • Unhook the tab on the right inside of the chassis at the same time, slightly pull the evaporator toward you until the tab is clear of the slot. 5. T o remove the Motor Cover • Remove 2 securing screw. • Pull the motor cover out from the chassis carefully. 6. T o remove the Cross-Flo w Fan • Loosen the screw ...

  • LG Electronics LAU121CNM - page 42

    42 Room Air Conditioner T r oub leshooting Guide T roubleshooting Guide INDOOR UNIT OUTDOOR UNIT INDOOR UNIT OUTDOOR UNIT HEAT EXCHANGE (EVAPORATOR) HEAT EXCHANGE (EVAPORATOR) HEAT EXCHANGE (CONDENSER) HEAT EXCHANGE (CONDENSER) COMPRESSOR COMPRESSOR ACCUMU LATOR GAS SIDE GAS SIDE 3-WAY VALVE LIQUID SIDE LIQUID SIDE 3-WAY VALVE CAPILLARY TUBE CAPILL ...

  • LG Electronics LAU121CNM - page 43

    Ser vice Manual 43 T roubleshooting Guide 2-wa y , 3-wa y V alve 2-way Valve (Liquid Side) 3-way Valve (Gas Side) Shaft position Shaft position Service port Closed Closed Closed (with valve cap) (with valve cap) (with cap) Open Closed Open (counter-clockwise) (clockwise) (push-pin or with vacumm pump) Open Open Closed (with valve cap) (with valve c ...

  • LG Electronics LAU121CNM - page 44

    44 Room Air Conditioner T roubleshooting Guide • Procedure (1) Confirm that both the 2-way and 3-way valves are set to the open position. – Remov e the v alv e stem caps and confir m that the v alve stems are in the r aised posi- tion. – Be sure to use a he xagonal wrench to operate the v alv e stems. (2) Operate the unit for 10 to 15 minutes ...

  • LG Electronics LAU121CNM - page 45

    Ser vice Manual 45 T roubleshooting Guide Balance Refrigerant of the 3-way V alve (Gas leakage) • Procedure (1) Confirm that both the 2-way and 3-way valves are set to the bac k seat. (2) Connect the charge set to the 3-way valve ’ s por t. – Leav e the v alv e on the charge set closed. – Connect the charge hose to the ser vice por t. (3) O ...

  • LG Electronics LAU121CNM - page 46

    46 Room Air Conditioner T roubleshooting Guide Ev acuation (All amount of refrigerant leaked) • Procedure (1) Connect the vacuum pump to the center hose of char ge set center hose (2) Evacuation for appr o ximatel y one hour . – Confir m that the gauge needle has mov ed tow ard -76 cmHg (v acuum of 4 mmHg or less). (3) Close the valve (Lo side) ...

  • LG Electronics LAU121CNM - page 47

    Ser vice Manual 47 T roubleshooting Guide Gas Charging (After Evacuation) • Procedure (1) Connect the charge hose to the charging cylinder . – Connect the charge hose which you dis- connected from the v acuum pump to the v alve at the bottom of the cylinder . – If you are using a gas cylinder , also use a scale and re v erse the cylinder so t ...

  • LG Electronics LAU121CNM - page 48

    48 Room Air Conditioner T roubleshooting Guide Additional gas c harging (Gas leakage) • When refrigerant is insufficient b y leakage, recharge the unit with the refrigerant up to normal oper- ating suction pressure. • Use the gr aph or the equation below to get oper ating suction pressure according to indoor and out- door temperature . Suction ...

  • LG Electronics LAU121CNM - page 49

    Ser vice Manual 49 T roubleshooting Guide T rouble anal ysis 1. Check temper ature diff erence between intak e and discharge air and operating current. Temp. Difference Temp. difference : approx. ° F(0 ° C) Current : less than 80% of rated current Temp. difference : approx. 14 ° F(8 ° C) Current : less than 80% of rated current Temp. difference ...

  • LG Electronics LAU121CNM - page 50

    50 Room Air Conditioner T roubleshooting Guide Electr onic P arts Pr oduct does not operate at all. (* Refer to Electr onic Contr ol Device dra wing and Schematic diagram.) Turn off Main Power Turn on Main Power Does "beeping" sound is made from the Indoor Unit? Primarily, the operating condition of Micom is OK. Check the voltage of power ...

  • LG Electronics LAU121CNM - page 51

    Ser vice Manual 51 T roubleshooting Guide The pr oduct is not operate with the remote controller . Turn on Main Power While the compressor has been stopped, the compressor does not operate owing to the delaying function for 3 minutes after stopped. Caused by other parts except the remote controller Cause by the remote controller When the mark( ) is ...

  • LG Electronics LAU121CNM - page 52

    52 Room Air Conditioner T roubleshooting Guide Compressor/Outdoor F an are unable to drive. Turn on Main Power Operate "Cooling Mode( )" by setting the desired temperature of the remote controller is less than one of the indoor temperature by 2 ° F at least. When in Fan Mode, Compressor/Outdoor Fan is stopped. Check the sensor for indoor ...

  • LG Electronics LAU121CNM - page 53

    Ser vice Manual 53 T roubleshooting Guide When indoor F an does not operate . Check connecting condition of the CN-MOTOR CON- NECTOR Does the voltage of terminal of CN-DC/DC CONNECTOR in Indoor unit corresponds to the values in the table of page 52 Do the voltage of terminal of CN-DC/DC CONNECTOR in Outdoor unit corresponds to the values in the tab ...

  • LG Electronics LAU121CNM - page 54

    54 Room Air Conditioner T roubleshooting Guide When V er tical Louver does not operate . • Confirm that the Vertical Louver is normally geared with the shaft of Stepping Motor. • If the regular torque is detected when rotating the Vertical Louver with hands Normal • Check the connecting condition of CN-UP/DOWN Connector • Check the solderin ...

  • LG Electronics LAU121CNM - page 55

    Ser vice Manual 55 T roubleshooting Guide • The operation indicator of Indoor unit blinks five times. • The red indicator of Outdoor unit blinks five times. Check the connecting wires between Indoor and Outdoor unit for the connecting error and the contacting condition. Check the installation condition of outdoor unit. Check for the communicati ...

  • LG Electronics LAU121CNM - page 56

    56 Room Air Conditioner T roubleshooting Guide The phenomena in case of connecting err or INDOOR UNIT Connector Type Condition Open and connecting error Open Open Open Open Short between terminals ( and ) CN-TH2. Short between terminals ( and ) CN-TH1. Short between terminals • The same as the phenomenon of Outdoor Unit. • The up/down vane does ...

  • LG Electronics LAU121CNM - page 57

    Ser vice Manual 57 OUTDOOR UNIT Connector Type Condition OPEN • PWB pattern is damaged when applying the power. Connecting reversely Connecting reversely OPEN OPEN OPEN OPEN Connecting error ( ) Connecting error ( ) Connecting error ( ) Connecting error ( ) Connecting error ( ) Connecting error ( ) • All functions stop. • The operation with t ...

  • LG Electronics LAU121CNM - page 58

    58 Room Air Conditioner Schematic Diagram Schematic Dia gram Electric Contr ol Device ■ Indoor ...

  • LG Electronics LAU121CNM - page 59

    Ser vice Manual 59 Schematic Diagram ■ Outdoor (12k) ...

  • LG Electronics LAU121CNM - page 60

    60 Room Air Conditioner Schematic Diagram Wiring Diagram ■ Indoor Unit Models: 12k ...

  • LG Electronics LAU121CNM - page 61

    Ser vice Manual 61 ■ Outdoor Unit Models: 12k(C/O) Models: 12k(H/P) Schematic Diagram ...

  • LG Electronics LAU121CNM - page 62

    62 Room Air Conditioner Schematic Diagram Components Location ■ Indoor MAIN P .W .B ASSEMBL Y • T OP VIEW • BO TT OM VIEW ...

  • LG Electronics LAU121CNM - page 63

    Ser vice Manual 63 ■ Outdoor(12k) • T OP VIEW • BO TT OM VIEW Schematic Diagram ...

  • LG Electronics LAU121CNM - page 64

    64 Room Air Conditioner DISPLA Y ASSEMBL Y Schematic Diagram LCD MODULE – 6871A00087B – 6306A90009A – 6306A90009C 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 CN_LIMIT2 CN_RECEIVER_1 CN_FORCE CN_STEPPING MOT OR(F/G) ASSM: 6871A00087 CN_TH1_1 CN_SUB CN_TH1_2 PWB: 6870A90720A <COMPONENT SIDE> – 6871A00088A 1 1 1 1 1 1 1 1 1 ASSM: 6871A00088 PWB: ...

  • LG Electronics LAU121CNM - page 65

    Ser vice Manual 65 Product Specifications Pr oduct Specifications Power Supply Ø , V, Hz Cooling Capacity BTU/h Input W Running Current A COMP. Locked Rotor AMP. A S.E.E.R Air Circulation m 3 G/min(cfm) Moisture Removal l/h(pts/hr) Noise Level Indoor, High dB(A) (Sound Pressure, 1m) Med dB(A) Low dB(A) Outdoor, Max dB(A) Features Temperature Contr ...

  • LG Electronics LAU121CNM - page 66

    Items Unit 66 Room Air Conditioner Product Specifications Cooling & Heating Power Supply ø , V, Hz Cooling Capacity BTU/h Heating Capacity BTU/h Input Cooling W Heating W Running Current Cooling A Heating A COMP. Locked Cooling A Rotor AMP. Heating A S.E.E.R H.S.P.E Air Circulation m 3 /min(cfm) Moisture Removal l/h(pts/hr) Noise Level Indoor, ...

  • LG Electronics LAU121CNM - page 67

    Ser vice Manual 67 Exploded Vie w 152302 137211 135316 263040 146811-2 268711-4 342800 359011 131410 733010 135311 147581 146811-1 346810 135516 249951 268711-3 268711-5 267110 35211B 354210 352116 263230-1 Inlet-air + Eva 352115 352150 266090 159830 Indoor Unit Exploded View ...

  • LG Electronics LAU121CNM - page 68

    68 Room Air Conditioner Exploded View Outdoor Unit: 12k Btu/h Seriess 550140 554160 567502 552113 437211 435301 447910 559010 546810 549610 554031 430410 552203-1 552203-2 437212 435511 649950 W0CZZ 567480-4 268711-6 552202 561410 552116 566000 567480-6 SUCTION ...

  • LG Electronics LAU121CNM - page 69

    Ser vice Manual 69 Replacement P ar ts List Replacement P ar ts List P arts List (Indoor) LOCATION DESCRIPTION PART No. REMARKS No. 131410 CHASSIS ASSEMBLY 3141A20034C 3141A20034C 359011 FAN ASSEMBLY,CROSS FLOW 5901A20017H 5901A20017H 346810 MOTOR ASSEMBLY,AC,INDOOR 4681AR2295L 4681AR2295L 342800 BEARING 4280A20004A 4280A20004A 135516 COVER ASSEMBL ...

  • LG Electronics LAU121CNM - page 70

    70 Room Air Conditioner Replacement P ar ts List P arts List (Outdoor) LOCATION DESCRIPTION PART No. REMARKS No. 430410 BASE ASSEMBLY,OUTDOOR 3041A20008K 3041A20008K - 552203-2 VALVE,SERVICE 2H02479N 2H02479N GAS PIPE 552203-1 VALVE,SERVICE 5220A20006A 5220A20006A LIQUID PIPE 554031 CONDENSER ASSEMBLY,BENDING 5403A20221C 5403A20221C - 549610 BRACKE ...

  • LG Electronics LAU121CNM - page 71

    P/No.: MFL31443001 Printed in Korea ...

Manufacturer LG Electronics Category Air Conditioner

Documents that we receive from a manufacturer of a LG Electronics LAU121CNM can be divided into several groups. They are, among others:
- LG Electronics technical drawings
- LAU121CNM manuals
- LG Electronics product data sheets
- information booklets
- or energy labels LG Electronics LAU121CNM
All of them are important, but the most important information from the point of view of use of the device are in the user manual LG Electronics LAU121CNM.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals LG Electronics LAU121CNM, service manual, brief instructions and user manuals LG Electronics LAU121CNM. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product LG Electronics LAU121CNM.

A complete manual for the device LG Electronics LAU121CNM, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use LG Electronics LAU121CNM by users. Manuals are usually written by a technical writer, but in a language understandable to all users of LG Electronics LAU121CNM.

A complete LG Electronics manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual LG Electronics LAU121CNM - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the LG Electronics LAU121CNM, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the LG Electronics LAU121CNM, that we can find in the current document
3. Tips how to use the basic functions of the device LG Electronics LAU121CNM - which should help us in our first steps of using LG Electronics LAU121CNM
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with LG Electronics LAU121CNM
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of LG Electronics LAU121CNM in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning LG Electronics LAU121CNM?

Use the form below

If you did not solve your problem by using a manual LG Electronics LAU121CNM, ask a question using the form below. If a user had a similar problem with LG Electronics LAU121CNM it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)