    GDS8 & GHS8 33-3/8" 80% Gas Furnace Unit s • Refer to Service Manual RS6610004 for installation, operation, and troubleshooting information. • All safety information must be followed as provided in the Service Manual. • Refer to the appropriate Parts Catalog for part number information. • Model numbers listed on page 3. RT6622011 S ...

  • Goodman Mfg GHS8 - page 2

    PRODUCT IDENTIFICA TION 2 The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. Installation and repair of this unit should be performed ONLY by individuals meeting the requirements of an "entry level technician&qu ...

  • Goodman Mfg GHS8 - page 3

    3 PRODUCT IDENTIFICA TION The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. * These models available in Low NOx The United States Environmental Protection Agency (“EPA”) has issued various regulations re- gardin ...

  • Goodman Mfg GHS8 - page 4

    4 PRODUCT DESIGN NFPA 54/ANSI Z223.1 - latest edition. In Canada, the fur- naces must be vented in accordance with the National Stan- dard of Canada, CAN/CSA B149.1 and CAN/CSA B149.2 - latest editions and amendments. NOTE: The vertical height of the Category I venting system must be at least as great as the horizontal length of the venting system. ...

  • Goodman Mfg GHS8 - page 5

    5 PRODUCT DIMENSIONS MO D EL A B G H S 80 453 A XC* 14 1/ 2 " 1 2 1/ 2" GH S 80 7 04 B X C * 17 1 / 2 " 1 6" GH S 80 9 05 C X C * 21" 1 9 1/ 2" MO D EL A B G D S 80 453 A XC* G D S 80 703 A XC* GD S 80 9 04 B X C * 17 1 / 2 " 1 6" GD S 81 1 55 C X C * 21" 1 9 1/ 2" 14 1/ 2 " 1 2 1/ 2" ...

  • Goodman Mfg GHS8 - page 6

    6 PRODUCT DESIGN GHS8 For installations in Canada, the GHS furances are certified only to 4,500 ft. * Negative pressure readings are in inches of water column (*w.c.) Part Nu mber B1 3701 45 O p en S et t in g ( ° F ) 300 GHS 804 53A XC* 2 GHS 807 04B XC* 2 GHS 809 05C XC* 2 R O LL O U T L IMI T SW IT C H ES P art N u m b er 0130F00038 O p en Se t ...

  • Goodman Mfg GHS8 - page 7

    7 PRODUCT DESIGN GDS8 Part Nu mber B1 3701 45 O p en S et t in g ( ° F ) 300 GDS 804 53A XC* 2 GDS 807 03A XC* 2 GDS 809 04B XC* 2 GDS 811 55C XC* 2 R O LL O U T L IMI T SW IT C H ES M od e l P a r t N o . O pe ns * G DS804 53A X C * B13 70142 - 0. 60 G DS807 03A X C * B1 37158 - 0. 70 G DS809 04B X C * B13 70142 - 0.60 G DS811 55C X C * B1 37158 ...

  • Goodman Mfg GHS8 - page 8

    8 PRODUCT DESIGN Coil Matches: A large array of Amana ® brand coils are available for use with the GHS8 furnaces, in horizontal applications and for the GDS8 for downflow applications. These coils are available in both cased and uncased models (with the option of a field installed TXV expansion device). These 80% furnaces match up with the existin ...

  • Goodman Mfg GHS8 - page 9

    9 PRODUCT DESIGN Thermost at s: NOTE: Complete lineup of thermostats can be found in the Thermostat Specification Sheets. Filters: Filters are required with this furnace and must be provided by the installer. The filters used must comply with UL900 or CAN/ULCS111 standards. Installing this furnace without filters will void the unit warranty Upflow ...

  • Goodman Mfg GHS8 - page 10

    10 PRODUCT DESIGN Counterflow Filters "A" Min Return Air Opti onal Ac ce ss Door This furnace has provisions for the installation of return air filters at the counterflow top return. The furnace will accommodate the following filter sizes depending on cabinet size: Refer to Minimum Filter Area tables to determine filter area requirement. ...

  • Goodman Mfg GHS8 - page 11

    FURNACE SPECIFICA TIONS 11 Unit specifications are subject to change without notice. ALWAYS refer to the unit's serial plate for the most up-to-date general and electrical information. NOTES: * These furnaces are manufactured for natural gas operation. Optional Kits are available for conversion to propane gas operation . * For elevations above ...

  • Goodman Mfg GHS8 - page 12

    FURNACE SPECIFICA TIONS Unit specifications are subject to change without notice. ALWAYS refer to the unit's serial plate for the most up-to-date general and electrical information. NOTES: * These furnaces are manufactured for natural gas operation. Optional Kits are available for conversion to propane gas operation . * For elevations above 20 ...

  • Goodman Mfg GHS8 - page 13

    13 BLOWER PERFORMANCE SPECIFICA TIONS GHS8 NOTES: • CFM in chart is without filter(s). Filters do not ship with this furnace, but must be provided by the installer. • All furnaces ship as high-speed cooling. Installer must adjust blower cooling speed as needed. • For most jobs, about 400 CFM per ton when cooling is desirable • INSTALLATION ...

  • Goodman Mfg GHS8 - page 14

    BLOWER PERFORMANCE SPECIFICA TIONS 14 GDS8 NOTES: • CFM in chart is without filter(s). Filters do not ship with this furnace, but must be provided by the installer. • All furnaces ship as hig-speed cooling. Installer must adjust blower cooling speed as needed. • For most jobs, about 400 CFM per ton when cooling is desirable • INSTALLATION I ...

  • Goodman Mfg GHS8 - page 15

    15 BLOWER PERFORMANCE SPECIFICA TIONS 30 40 50 60 70 80 9 0 11 0 12 0 100 13 0 14 0 15 0 10 0 90 80 70 60 50 40 30 20 10 OUTP UT BTU/H R x 10 00 BTU OUTPUT vs T EM PERATURE RISE CHART TEMPERAT URE RISE 600 C FM 700 900 1000 1100 1200 140 0 1600 1800 2000 220 0 240 0 C F M FORMULAS BTU OUT PUT = CFM x 1. 08 x RI SE RISE = BTU O UTP UT 1.0 8 ÷ CF M ...

  • Goodman Mfg GHS8 - page 16

    16 WIRING DIAGRAMS Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring. HIGH VOL T A GE! DISCONNECT ALL POWER BEFORE SERVICI NG OR INST A LLING THIS UNIT . M UL T IPL E POW ER SOUR CES MA Y BE P RESENT . F AILURE TO DO SO MA Y CAUS E PROP ERTY DAMAG E, PERSONAL INJURY OR DEA TH . G*S8 B O X ...

Manufacturer Goodman Mfg Category Gas Heater

Documents that we receive from a manufacturer of a Goodman Mfg GHS8 can be divided into several groups. They are, among others:
- Goodman Mfg technical drawings
- GHS8 manuals
- Goodman Mfg product data sheets
- information booklets
- or energy labels Goodman Mfg GHS8
All of them are important, but the most important information from the point of view of use of the device are in the user manual Goodman Mfg GHS8.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Goodman Mfg GHS8, service manual, brief instructions and user manuals Goodman Mfg GHS8. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Goodman Mfg GHS8.

A complete manual for the device Goodman Mfg GHS8, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Goodman Mfg GHS8 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Goodman Mfg GHS8.

A complete Goodman Mfg manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Goodman Mfg GHS8 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Goodman Mfg GHS8, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Goodman Mfg GHS8, that we can find in the current document
3. Tips how to use the basic functions of the device Goodman Mfg GHS8 - which should help us in our first steps of using Goodman Mfg GHS8
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Goodman Mfg GHS8
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Goodman Mfg GHS8 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Goodman Mfg GHS8?

Use the form below

If you did not solve your problem by using a manual Goodman Mfg GHS8, ask a question using the form below. If a user had a similar problem with Goodman Mfg GHS8 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)