Manual Clarion UNGO MS3001

26 pages 2.12 mb
Download

Go to site of 26

Summary
  • Clarion UNGO MS3001 - page 1

    install_MS3001.qxd 8/11/99 4:15 PM Page 1 ...

  • Clarion UNGO MS3001 - page 2

    1. Before Y ou Begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 1 2. Installation Tips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 2 3. Mounting Components Main Unit . . . . . . . . . . . . . . . . . ...

  • Clarion UNGO MS3001 - page 3

    MS3001 / MS3200 Installation Manual - Page 1 1. Be sure to read the manual thoroughly before beginning the installation to ensure a proper understanding of the MS3001 / MS3200 and its functions. 2. V erify system contents: ❑ Main Unit ❑ Two 3-Button Remote T ransmitters ❑ Siren (MS3001 only) ❑ Battery Backup Siren (MS3200 only) ❑ Harnesse ...

  • Clarion UNGO MS3001 - page 4

    Page 2 - MS3001 / MS3200 Installation Manual 1. Use a V olt / Ohm meter to test all wires. Do not use a test light. 2. Good power and ground connections are essential for proper operation. 3. Route all wires from the engine compartment to the interior of the vehicle through a grommet and use electrical tape and split loom tubing for protection. 4. ...

  • Clarion UNGO MS3001 - page 5

    MS3001 / MS3200 Installation Manual - Page 3 Main Unit The main unit should be mounted in the interior of the vehicle. Do not mount the main unit in the engine compartment. For maximum security , avoid mounting the main unit where it will be easily accessible to a thief. If you are mounting the unit under the dash board, be sure to mount the unit a ...

  • Clarion UNGO MS3001 - page 6

    Page 4 - MS3001 / MS3200 Installation Manual For maximum security , it is best to disguise all under hood system wires with factory style split loom tubing so that they cannot be easily identified by a thief. Run all wires from the engine compartment into the interior of the vehicle through a grommet. When testing the system, be sure to turn the si ...

  • Clarion UNGO MS3001 - page 7

    MS3001 / MS3200 Installation Manual - Page 5 +12v +12v Chassis Ground +12v LED Override Switch Black Red White Y ellow White/brown Orange +12v (MS3200 only) Y ellow/white Red/yellow P arking Lights Relay Dome Light Relay Horn Relay 10A Negative Door Pins witch P ositive Door Pinswitch Dome Light Dome Light Negative Hood/ T r unk Switch (+) or (-) o ...

  • Clarion UNGO MS3001 - page 8

    Page 6 - MS3001 / MS3200 Installation Manual 14-Pin Main Harness Pin 1 - BLACK: Ground. Connect to a solid chassis ground. Be sure to use a ring connector of proper size. Scrape away the paint at the grounding point. Pin 2 - RED: Main Power (+12v) input [3A fuse]. Connect to constant +12v . A clean source of power is essential. This connection can ...

  • Clarion UNGO MS3001 - page 9

    MS3001 / MS3200 Installation Manual - Page 7 In this configuration, the vehicle ’ s starter will be disabled only when the system is armed and alarming. If power to the system is lost or the system becomes disconnected, the vehicle will be able to start. Pin 12 - BLUE/red: Starter Defeat Normally Open (-) output. Provides a negative output while ...

  • Clarion UNGO MS3001 - page 10

    Page 8 - MS3001 / MS3200 Installation Manual 4-Pin Auxiliary Function Harness Pin 1 - YELLOW/black: Auxiliary Function 2 (-) output. Provides a negative output to activate a relay . The output of this wire can be set to operate in one of two operating modes. See Jumper Settings . Momentary - provides output for as long as the transmitter button is ...

  • Clarion UNGO MS3001 - page 11

    MS3001 / MS3200 Installation Manual - Page 9 Jumper Selections Parking Light Polarity . Selects the polarity (+/-) for the output of the on-board Parking Light relay . Pin 1 + Pin 2 = positive Pin 2 + Pin 3 = negative Auto Rearm. When the jumper is off the system will automatically rearm if no other activity is detected within one minute of Remote ...

  • Clarion UNGO MS3001 - page 12

    Page 10 - MS3001 / MS3200 Installation Manual Accessing the Jumpers Using a flathead screwdriver , carefully press in on the access tabs on the sides of the case until the hooks release. T ake care not to push the tabs in too far or they may break. Once you have made your selections, close the case by aligning the top and button halves of the case, ...

  • Clarion UNGO MS3001 - page 13

    MS3001 / MS3200 Installation Manual - Page 11 Remote T ransmitter Layout Each system comes with 2 Remote T ransmitters, pre-programmed to Arm and Disarm the system with chirp confirmation using Button 1 . Button 1 Arms and Disarms the system. This Button also locks and unlocks the doors when the system is in V alet Mode. Button 2 controls the syste ...

  • Clarion UNGO MS3001 - page 14

    Page 12 - MS3001 / MS3200 Installation Manual T wo Car Operation For your convenience, you may use a single transmitter to operate multiple vehicles. The T ransmitter can be set to arm Car #1 with Button 1 and arm additional cars with the first available Buttons not being used by Car #1. The following diagram illustrates how a single transmitter ca ...

  • Clarion UNGO MS3001 - page 15

    MS3001 / MS3200 Installation Manual - Page 13 Adding a New T ransmitter into the System 1. T urn on the ignition. 2. Press and hold the Override switch. • The status LED will turn on red. 3. Within 5 seconds: Continue holding the Override switch and Press T ransmitter Button 1* For remote arming with chirp confirmation. --- or --- Release the Ove ...

  • Clarion UNGO MS3001 - page 16

    Page 14 - MS3001 / MS3200 Installation Manual Arming Mode Selection (Passive or Active Arming) Using the Remote T ransmitter, you may select Passive Arming with chirp confirmation, Passive Arming without chirp confirmation, or Active Arming (Remote only). T o set the Arming Mode: 1. T urn the ignition on. 2. Within 4 seconds, press T ransmitter But ...

  • Clarion UNGO MS3001 - page 17

    MS3001 / MS3200 Installation Manual - Page 15 V alet Mode Allows you to temporarily disable the security system when the car is being serviced or turned over to a parking attendant. T o turn V alet Mode on or off: 1. T urn on the ignition. 2. Press and hold the override switch. 3. While holding the override switch, turn off the ignition. • The si ...

  • Clarion UNGO MS3001 - page 18

    Page 16 - MS3001 / MS3200 Installation Manual The MS3001 / MS3200 ’ s dual stage, on-board Shock Sensor is adjusted entirely through the use of the Remote T ransmitter. T rigger Sensitivity The T rigger sensitivity is adjustable to 8 levels, including an “ off ” setting where the sensor is ignored. T o Adjust the T rigger sensitivity: 1. T ur ...

  • Clarion UNGO MS3001 - page 19

    MS3001 / MS3200 Installation Manual - Page 17 Y ou can use this chart to quickly identify and interpret the MS3001 / MS3200 system ’ s chirp indications and LED flashes. The system continuously monitors all protected zones, even when it is not armed, and warns you if it detects a problem when you turn off the ignition. 1. T urn off the ignition. ...

  • Clarion UNGO MS3001 - page 20

    Page 18 - MS3001 / MS3200 Installation Manual Dome Light Control Relay Diagrams The Auxiliary Function 2 Output can be set for momentarty or latched operation allowing custom operation of vehicle systems such as: Remote Control of Audio System (Latched Operating Mode) This enables the user to listen to the vehicle ’ s audio or video system for ex ...

  • Clarion UNGO MS3001 - page 21

    MS3001 / MS3200 Installation Manual - Page 19 Door Lock Diagrams Negative T rigger Positive T rigger V oltage Reversal Aftermarket Actuators V acuum Lock System White/green = (-) Lock White/blue = (-) Unlock install_MS3001.qxd 8/11/99 4:15 PM Page 19 ...

  • Clarion UNGO MS3001 - page 22

    Page 20 - MS3001 / MS3200 Installation Manual The optional DLRM is a factory door lock integration module with built-in relays for use with high current positive trigger door locking systems (like those found on some older GM models) and voltage reversal door locking systems (also known as 5-wire systems, found on many Ford vehicles and some GM mod ...

  • Clarion UNGO MS3001 - page 23

    MS3001 / MS3200 Installation Manual - Page 21 Be sure to add a fuse to the violet wire of the 5-pin harness and connect to a constant source of power separate from the alarm ’ s power wire. DO NOT connect the DLRM V iolet wire to alarm ’ s main power lead . High Current Positive T rigger System V oltage Reversal System Adding Aftermarket Actuat ...

  • Clarion UNGO MS3001 - page 24

    Page 22 - MS3001 / MS3200 Installation Manual Notes install_MS3001.qxd 8/11/99 4:15 PM Page 22 ...

  • Clarion UNGO MS3001 - page 25

    MS3001 / MS3200 Installation Manual - Page 23 Notes install_MS3001.qxd 8/11/99 4:15 PM Page 23 ...

  • Clarion UNGO MS3001 - page 26

    +12v +12v Chassis Ground +12v LED Override Switch Black Red White Y ellow White/brown Orange +12v (MS3200 only) Y ellow/white Red/yellow P arking Lights Relay Dome Light Relay Horn Relay 10A Negative Door Pins witch P ositive Door Pinswitch Dome Light Dome Light Negative Hood/ T r unk Switch (+) or (-) output Siren (+) output Aux 1(-) output Y ello ...

Manufacturer Clarion Category Automobile Alarm

Documents that we receive from a manufacturer of a Clarion UNGO MS3001 can be divided into several groups. They are, among others:
- Clarion technical drawings
- UNGO MS3001 manuals
- Clarion product data sheets
- information booklets
- or energy labels Clarion UNGO MS3001
All of them are important, but the most important information from the point of view of use of the device are in the user manual Clarion UNGO MS3001.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Clarion UNGO MS3001, service manual, brief instructions and user manuals Clarion UNGO MS3001. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Clarion UNGO MS3001.

Similar manuals

A complete manual for the device Clarion UNGO MS3001, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Clarion UNGO MS3001 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Clarion UNGO MS3001.

A complete Clarion manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Clarion UNGO MS3001 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Clarion UNGO MS3001, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Clarion UNGO MS3001, that we can find in the current document
3. Tips how to use the basic functions of the device Clarion UNGO MS3001 - which should help us in our first steps of using Clarion UNGO MS3001
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Clarion UNGO MS3001
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Clarion UNGO MS3001 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Clarion UNGO MS3001?

Use the form below

If you did not solve your problem by using a manual Clarion UNGO MS3001, ask a question using the form below. If a user had a similar problem with Clarion UNGO MS3001 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)