Manual Graco Inc. 02017

32 pages 1.11 mb
Download

Go to site of 32

Summary
  • Graco Inc. 02017 - page 1

    308–293 Rev . G Supersedes E and PCN G  INSTRUCTIONS-P ARTS LIST INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. Model M-1265, Series B Optimiser  HVLP Spray Gun 100 psi (0.7 MPa, 7 bar) Maximum Working Fluid Pressure 100 psi (0.7 MPa, 7 bar) Maximum Working Air Pressure 65 psi ...

  • Graco Inc. 02017 - page 2

    2 308–293 T able of Contents W arnings 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Selection Charts 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Air Flow and Atomizing Pressure 7 . . . . . . . . . . . . . . . . . T ypical Installation 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Graco Inc. 02017 - page 3

    308–293 3 W ARNING PRESSURIZED EQUIPMENT HAZARD Spray from the gun, hose leaks or ruptured components can splash fluid in the eyes or on the skin and cause serious injury .  Do not stop or deflect fluid leaks with your hand, body , glove or rag.  Follow the Pressure Relief Procedure on page 13 when: you are instructed to relieve pressure; s ...

  • Graco Inc. 02017 - page 4

    4 308–293 Selection Charts TERMS: Light Fluid: Up to 18 seconds with No. 2 Zahn cup (20 centipoise) Medium Fluid: 19 to 28 seconds with No. 2 Zahn cup (20–64 centipoise) Heavy Fluid: Greater than 28 seconds with No. 2 Zahn cup (greater than 64 centipoise) -- 2.8 V olatile Organic Compounds, High-solid Polyurethanes, Heavy W aterborne Enamels P/ ...

  • Graco Inc. 02017 - page 5

    308–293 5 Selection Charts CHART 1: GUN ASSEMBLIES, Series B (continued) Optional Non-HVLP Compliant Gun Assemblies With standard needle and nozzle and optional high pressure air cap Includes: Optional Complete Gun Assy . Part No. Needle Assy . P/N * Nozzle P/N { High Pressure Air Cap P/N Orifice Size Material Usage (See TERMS on page 4) 236–02 ...

  • Graco Inc. 02017 - page 6

    6 308–293 Selection Charts CHART 3: OPTIONAL ORIFICE PURGE SST NEEDLE  Optional Stainless Steel Orifice-Purge Needle Part No. Orifice Size 186–931 0.042” (1.067 mm) 186–932 0.055” (1.397 mm) 186–933 0.070” (1.778 mm) 186–934 0.086” (2.184 mm)  Use these needles to purge fluid out of the nozzle orifice to prevent pluggi ...

  • Graco Inc. 02017 - page 7

    308–293 7 Air Flow and Atomizing Pressure NOTE: All tests were completed with the pattern adjustment valve fully open. Air Flow                           #! ? ...

  • Graco Inc. 02017 - page 8

    8 308–293 T ypical Installation KEY A Model M-1265 Spray Gun See page 4 for part numbers. B Fluid Inlet; 3/8 npsm (R3/8–19) C Air Inlet; 1/4 npsm D Air Hose Recommend 5/16” (7.9 mm) ID hose Optional 3/8” (9.5 mm) ID hose E Air Shut-of f V alve F Air Regulator G Air Filter H Air Supply Line A B C D EF G 02018 NOTE : See the Accessories secti ...

  • Graco Inc. 02017 - page 9

    308–293 9 Setup 1. Connect the Air Line NOTE:  Yo u must install an air pressure regulator (F) on the gun air line to control air pressure to the gun. See Fig. 2.  If your regulated air source does not have a filter , install an air filter (G) on the air line to ensure a dry , clean air supply to the gun. Dirt and moisture can ruin the appe ...

  • Graco Inc. 02017 - page 10

    10 308–293 Setup 3. Flush the Spray Gun. Before running any paint through the spray gun, flush the gun out with a solvent that is compatible with the fluid to be sprayed, using the lowest possible fluid pressure and a grounded metal container . Fig. 5 02053 W ARNING PRESSURIZED EQUIPMENT HAZARD T o reduce the risk of a serious injury whenever you ...

  • Graco Inc. 02017 - page 11

    308–293 1 1 Setup 6. Adjust the Spray Pattern (continued) B. Adjust the fluid flow using the fluid pressure regulator (L) installed in the gun fluid line. T ypical industrial flow rates will vary with regulator pres - sures from 5 to 10 psi (34 to 70 kPa, 0.3 to 0.7 bar). Fig. 8 L 02059 C. Hold the gun parallel to the floor and adjust the fluid p ...

  • Graco Inc. 02017 - page 12

    12 308–293 Setup 6. Adjust the Spray Pattern (continued) E. Open the pattern adjustment valve (13a) by turning it fully counterclockwise for a full fan pattern.  Fig. 12 13a Open (wider pattern) Close (narrower pattern*) F. Using the air pressure regulator (F), set the gun air supply pressure at 50 psi (345 kPa, 3.4 bar) at the gun ...

  • Graco Inc. 02017 - page 13

    308–293 13 Operation Pressure Relief Procedure W ARNING PRESSURIZED EQUIPMENT HAZARD The system pressure must be manually relieved to prevent the system from starting or spraying acci - dentally . T o reduce the risk of an injury from acci - dental spray from the gun, splashing fluid, or moving parts, follow the Pressure Relief Proce - dure whene ...

  • Graco Inc. 02017 - page 14

    14 308–293 Daily Gun Care, Flushing, and Cleaning W ARNING PRESSURIZED EQUIPMENT HAZARD T o reduce the risk of a serious injury whenever you are instructed to relieve pressure, follow the Pres- sure Relief Procedure on page 13. CAUTION Clean all parts with a non-conductive solvent, com - patible with the fluid being sprayed. Conductive solvents c ...

  • Graco Inc. 02017 - page 15

    308–293 15 Daily Gun Care, Flushing, and Cleaning W ARNING PRESSURIZED EQUIPMENT HAZARD T o reduce the risk of a serious injury whenever you are instructed to relieve pressure, follow the Pres- sure Relief Procedure on page 13. 1. Relieve the pressure. 2. Disconnect the fluid supply hose (J) from the gun; do not disconnect the air supply hose. Fi ...

  • Graco Inc. 02017 - page 16

    16 308–293 Daily Gun Care, Flushing, and Cleaning 8. Remove the air cap ring (12) and air cap (19). 9. T rigger the gun while you remove the fluid nozzle (20) from the gun with the gun wrench (35). Fig. 5 02060A 35 20 12, 19 CAUTION T rigger the gun whenever you tighten or remove the nozzle. This keeps the needle seat away from the nozzle seating ...

  • Graco Inc. 02017 - page 17

    308–293 17 Daily Gun Care, Flushing, and Cleaning 14. T rigger the gun while you install the fluid nozzle (20) with the gun wrench (35). CAUTION When tightening the nozzle, do not exceed 35 in-lbs (4 N S m) torque. Over-tightening the nozzle can cause the nozzle hex to round, can af fect the spray pattern, and is unnecessary to guarantee a seal. ...

  • Graco Inc. 02017 - page 18

    18 308–293 T roubleshooting W ARNING PRESSURIZED EQUIPMENT HAZARD T o reduce the risk of a serious injury , follow the Pressure Relief Procedure on page 13 before checking or repairing any part of the gun or sys - tem. PROBLEM CAUSE SOLUTION Fluid flow is fluttering while spraying 1. Fluid nozzle not tight enough 2. Fluid filter clogged 3. Fluid ...

  • Graco Inc. 02017 - page 19

    308–293 19 Notes ...

  • Graco Inc. 02017 - page 20

    20 308–293 Service Items Needed for Service  Gun W rench – provided  Seal Installation T ool – provided  Adjustable W rench  Screw Driver  Lubricant part no. 1 1 1–265; see Accessories to order  Compatible Solvent NOTE:  Gun Repair Kit 236–007 is available. The kit in - cludes the air valve assembly (14), ring packing ...

  • Graco Inc. 02017 - page 21

    308–293 21 Service CAUTION Do not use excessive force to push out the packing assembly (39) or the u-cup seal (33) as this may bend the fluid needle (21). Refer to Fig. 3 and 4. If packings are difficult to remove, use a 3/16 in. plastic rod to push them out. 9. Push the three piece packing assembly (39) out toward the back of the gun, with the t ...

  • Graco Inc. 02017 - page 22

    22 308–293 Service Assembly 1. Insert the fluid needle (21) through the front of the gun as shown in Fig. 6. Install the new packing assembly (39) by placing them on the end of the needle tip. Orientate the packings as shown in Fig. 6. Fig. 6  21 39 1 W asher U-cup; lips face down Spreader 2 3 1 2 3 2. Place the packing adjustment ...

  • Graco Inc. 02017 - page 23

    308–293 23 Service 8. T ighten the packing adjustment screw (31) with the gun wrench (35), as shown in Fig. 10, until you can feel a slight drag on the fluid needle. Do not over- tighten the screw as this may bind the needle movement. Fig. 10 02104A 31 35 9. Install the trigger (3). T orque the screw (5) to 10–15 in-lbs (1.1–1.7 N  m). See ...

  • Graco Inc. 02017 - page 24

    24 308–293 Parts Drawing 02025A 12 11 15 16 8 33* 14* 3 13a 34 2 4 32* 25 19 20 13c n 13b 13d n 5 39* 31 n 6 22* 21 1 Ref No. 13 Includes items 13a–13d 35 42 1 2 3 4 4 5 6 6 1 1 1 2 7 7 3 8 8 3 21 1 Needle for standard guns Needle set for optional guns Lightly lubricate Lightly lubricate threads T orque to 25–35 in-lbs (2.8–4.0 N S m) Be su ...

  • Graco Inc. 02017 - page 25

    308–293 25 Parts List Part No. 236–013 to 236–016, Series B M-1265 Standard HVLP Spray Gun With standard needle, nozzle, and air cap Includes items 1–42 Part No. 236–020 to 236–028, Series B M-1265 Optional HVLP Spray Gun With optional needle, nozzle, and air cap Includes items 1–42 Part No. 236–023 and 236–024, Series B M-1265 Op ...

  • Graco Inc. 02017 - page 26

    26 308–293 Accessories Cleaning Brush 105–749 For use in cleaning gun Lubricant 1 1 1–265 One 4 oz. (1 13 gram) tube sanitary (non-silicone) lubricant for fluid seals and wear areas. 03405 Fluid T ube Kit 236–318 Allows air and fluid hoses to be more easily strapped together and eases gun movement by the operator . High Pressure Air Cap 189 ...

  • Graco Inc. 02017 - page 27

    308–293 27 Accessories SST Pressure Cup Kit 235–374 with double air regulator 1 qt. (0.95 liter) capacity , 304 stainless steel cup. Includes a pressure relief valve, a 0–100 psi (0–0.7 MPa, 0–7 bar) air regulator for gun atomization, and a 0–15 psi (0–104 kPa, 0–1.0 bar) air regulator for the 1 qt. pressure cup supply air . 01726 0 ...

  • Graco Inc. 02017 - page 28

    28 308–293 Accessories Low Pressure SST Pressure T anks For fluid pressures up to 15 psi (104 kPa, 1.0 bar) High Pressure SST Pressure T anks For fluid pressures up to100 psi (700 kPa, 7 bar) T ank Size gallons (liters) Low Pressure T ank P/N Low Pressure T ank with Agitator P/N High Pressure T ank P/N High Pressure T ank with Agitator P/N 5 (19) ...

  • Graco Inc. 02017 - page 29

    308–293 29 Notes ...

  • Graco Inc. 02017 - page 30

    30 308–293 Notes ...

  • Graco Inc. 02017 - page 31

    308–293 31 Notes ...

  • Graco Inc. 02017 - page 32

    32 308–293 Graco W arranty and Limitation of Liability W ARRANTY Graco warrants all equipment listed in this manual which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale by an authorized Graco distributor to the original purchaser for use. Graco will, for a period of twelve mon ...

Manufacturer Graco Inc. Category Paint Sprayer

Documents that we receive from a manufacturer of a Graco Inc. 02017 can be divided into several groups. They are, among others:
- Graco Inc. technical drawings
- 02017 manuals
- Graco Inc. product data sheets
- information booklets
- or energy labels Graco Inc. 02017
All of them are important, but the most important information from the point of view of use of the device are in the user manual Graco Inc. 02017.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Graco Inc. 02017, service manual, brief instructions and user manuals Graco Inc. 02017. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Graco Inc. 02017.

Similar manuals

A complete manual for the device Graco Inc. 02017, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Graco Inc. 02017 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Graco Inc. 02017.

A complete Graco Inc. manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Graco Inc. 02017 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Graco Inc. 02017, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Graco Inc. 02017, that we can find in the current document
3. Tips how to use the basic functions of the device Graco Inc. 02017 - which should help us in our first steps of using Graco Inc. 02017
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Graco Inc. 02017
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Graco Inc. 02017 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Graco Inc. 02017?

Use the form below

If you did not solve your problem by using a manual Graco Inc. 02017, ask a question using the form below. If a user had a similar problem with Graco Inc. 02017 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)