    Hearth & Home T echnologies Inc. • Cinch Pipe & T erm Caps • 4033-900 Rev K • 05/05 1 TM TM Models: Cinch Pipe & T ermination Cap System Installation Instructions If you need assistance during installation, contact your local dealer or the T echnical Serices Dept., Hearth & Home T echnologie s Inc., phone 1-800-927-6841 or 1-8 ...

  • Hearth and Home Technologies Cinch Pipe & Termination Cap System - page 2

    Hearth & Home T echnologies Inc. • Cinch Pipe & T erm Caps • 4033-900 Rev K • 05/05 2 DVP-TV V ertical termination cap. Includes storm collar and fastener pack. DVP-TB1 Basement/window well termination cap. Includes fas- tener pack. DVP-TRAP2 Horizontal termination cap with 4 in. telescoping fl ue. Includes DVP-WS wall shield with he ...

  • Hearth and Home Technologies Cinch Pipe & Termination Cap System - page 3

    Hearth & Home T echnologies Inc. • Cinch Pipe & T erm Caps • 4033-900 Rev K • 05/05 3 COOL ADD Cap shield DRC-RADIUS Cap shield DVP-TRAPFL DVP-TRAP1 or DVP-TRAP2 termination cap rain fl ashing DVP-TRAP1 DVP-TRAP2 T ermination Cap DVP-TRAPFL Flashing Components Description DRC-RADIUS Cap Shield COOL-ADDM Cap Shield - pack of six DVP-T ...

  • Hearth and Home Technologies Cinch Pipe & Termination Cap System - page 4

    Hearth & Home T echnologies Inc. • Cinch Pipe & T erm Caps • 4033-900 Rev K • 05/05 4 V ent depth is measured from the back of the appliance to the outer edge of the exterior wall. See T able 1 and Figure 1. Figure 1 - Measuring Required V ent Depth T able 1 TRAP CAP SPECIFICA TION CHART Appliance DVP-TRAPK1 T op V ent Depth DVP-TRAP1 ...

  • Hearth and Home Technologies Cinch Pipe & Termination Cap System - page 5

    Hearth & Home T echnologies Inc. • Cinch Pipe & T erm Caps • 4033-900 Rev K • 05/05 5 3 in. (76 mm) top clearance 1 in. (25 mm) clearance bottom & sides Heat Shield Wa l l Shield Heat Shield WA L L Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm). Figure 2.2 Horizontal V enting Clearances to Combustible Materi- al ...

  • Hearth and Home Technologies Cinch Pipe & Termination Cap System - page 6

    Hearth & Home T echnologies Inc. • Cinch Pipe & T erm Caps • 4033-900 Rev K • 05/05 6 C. Assemble V ent Sections Figure 2.5 Lances A B Figure 2.6 Inner/Outer A B Figure 2.7 Snapped CORRECT INCORRECT Make sure the seams are not aligned to prevent unintentional disconnection. Figure 2.8 Seams Fire Risk Exhaust Fumes Risk • Overlap pip ...

  • Hearth and Home Technologies Cinch Pipe & Termination Cap System - page 7

    Hearth & Home T echnologies Inc. • Cinch Pipe & T erm Caps • 4033-900 Rev K • 05/05 7 Assemble Minimum Installation (MI) Sections MI sections are non-unitized so that they can be cut to a specifi c length. Cut these sections to length from the non- expanded end (see Figure 2.9). They can then be attached by fi rst connecting the exp ...

  • Hearth and Home Technologies Cinch Pipe & Termination Cap System - page 8

    Hearth & Home T echnologies Inc. • Cinch Pipe & T erm Caps • 4033-900 Rev K • 05/05 8 Secure the V ent Sections V ertical sections of pipe must be supported every 8 ft after the 25 ft maximum unsupported rise. The vent support or plumber ’s strap (spaced 120° apart) may be used to do this (see Figures 2.12 and 2.13). Horizontal sec ...

  • Hearth and Home Technologies Cinch Pipe & Termination Cap System - page 9

    Hearth & Home T echnologies Inc. • Cinch Pipe & T erm Caps • 4033-900 Rev K • 05/05 9 Burn Risk • Local codes may require installation of a cap shield to prevent anything or anyone from touching the hot cap. W ARNING Do NOT connect a pipe section to a termination cap without using the telescoping fl ue section found on the terminat ...

  • Hearth and Home Technologies Cinch Pipe & Termination Cap System - page 10

    Hearth & Home T echnologies Inc. • Cinch Pipe & T erm Caps • 4033-900 Rev K • 05/05 10 F . V ertical Penetration Framing Note: The fi restop spacer is not required if at tic insulat ion shield is used. Install Attic Insulation Shield • Frame opening for attic insulation shield. • Attic insulation shield may be installed above or ...

  • Hearth and Home Technologies Cinch Pipe & Termination Cap System - page 11

    Hearth & Home T echnologies Inc. • Cinch Pipe & T erm Caps • 4033-900 Rev K • 05/05 11 Figure 2.20 Secure with Screws G. Install Roof Flashing and V ertical T ermination Cap T o attach the vertical termination cap, slide the inner collar of the cap into the inner fl ue of the pipe section and place the outer collar of the cap over th ...

  • Hearth and Home Technologies Cinch Pipe & Termination Cap System - page 12

    Hearth & Home T echnologies Inc. • Cinch Pipe & T erm Caps • 4033-900 Rev K • 05/05 12 H. Assemble and Install Storm Collar Connect both halves of the storm collar with two screws (see Figure 2.21). Wrap the storm collar around the exposed pipe section and align brackets. Insert a bolt (provided) through the brackets and tighten nut t ...

Manufacturer Hearth and Home Technologies Category Indoor Fireplace

Documents that we receive from a manufacturer of a Hearth and Home Technologies Cinch Pipe & Termination Cap System can be divided into several groups. They are, among others:
- Hearth and Home Technologies technical drawings
- Cinch Pipe & Termination Cap System manuals
- Hearth and Home Technologies product data sheets
- information booklets
- or energy labels Hearth and Home Technologies Cinch Pipe & Termination Cap System
All of them are important, but the most important information from the point of view of use of the device are in the user manual Hearth and Home Technologies Cinch Pipe & Termination Cap System.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Hearth and Home Technologies Cinch Pipe & Termination Cap System, service manual, brief instructions and user manuals Hearth and Home Technologies Cinch Pipe & Termination Cap System. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Hearth and Home Technologies Cinch Pipe & Termination Cap System.

A complete manual for the device Hearth and Home Technologies Cinch Pipe & Termination Cap System, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Hearth and Home Technologies Cinch Pipe & Termination Cap System by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Hearth and Home Technologies Cinch Pipe & Termination Cap System.

A complete Hearth and Home Technologies manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Hearth and Home Technologies Cinch Pipe & Termination Cap System - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Hearth and Home Technologies Cinch Pipe & Termination Cap System, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Hearth and Home Technologies Cinch Pipe & Termination Cap System, that we can find in the current document
3. Tips how to use the basic functions of the device Hearth and Home Technologies Cinch Pipe & Termination Cap System - which should help us in our first steps of using Hearth and Home Technologies Cinch Pipe & Termination Cap System
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Hearth and Home Technologies Cinch Pipe & Termination Cap System
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Hearth and Home Technologies Cinch Pipe & Termination Cap System in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Hearth and Home Technologies Cinch Pipe & Termination Cap System?

Use the form below

If you did not solve your problem by using a manual Hearth and Home Technologies Cinch Pipe & Termination Cap System, ask a question using the form below. If a user had a similar problem with Hearth and Home Technologies Cinch Pipe & Termination Cap System it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)