    381333–319 A 50 Hanove r Road, F lorham Park, New J ersey 07932–1591 USA For sales or service call 1 800 800–2726 (A SCO ) www.ascopower .com AS CO PO WER TECH NO LOGI E S CA NA DA PO Box 1238, 17 Airport R oad, Brantf ord, O ntario, Can ada N 3T 5T3 telephone 519 758– 8450, f ax 519 758– 0876, f or service ca ll 1 888 234–2726 (A SCO ) ...

  • Emerson 185 - page 2

    Seri es 185 381333–319 A Namepl ate The T rans fer Switch nam epla te incl udes data for each spec ific A SCO Se ries 185 A TS . Use th e A TS on ly with in the limits shown o n this nameplate. Ca talog Num ber Identif icatio n A typ ica l Cata l og Number is shown be l ow with i ts elements ex plained . Th e example is f or a D–d esign , 2 pol ...

  • Emerson 185 - page 3

    INST ALLA TION Series 185 1 381333–319 A Instal lation of the ASCO Series 18 5 automatic transfer switc h (A TS) m ust be perfor med by a lic ensed elec trician. It m ust be in stall ed ac cor ding to th e National E lec tric al Code (NEC) and all l ocal el ectric al code requirem ents. R emove the enclosure c over and i nspect the A TS for shipp ...

  • Emerson 185 - page 4

    CONT ROLLER Seri es 185 2 381333–319 A The Gr oup 4 dig ital Con trol ler is us ed in A SCO Ser ies 185 autom atic transfer sw itches. It provides the sensing , timing, a nd control functions for the A TS. T his micro– processor–based control ler includes buil t–i n control buttons and sta tus lights for control of the A T S and generator. ...

  • Emerson 185 - page 5

    CONT ROLLER Series 185 (continued) 3 381333–319 A 3 - - - Gene rator S tarting Contacts The generat or starti ng contacts connections are on t he controller. R efe r to the generato r manual. Disconnect the ge nerator b attery and ve rify that the ig nition sw itch is in the OF F position. Connec t the gen erator startin g wires to t he appropri ...

  • Emerson 185 - page 6

    Seri es 185 CONT ROLLER (cont inued) 4 381333–319 A S2 DIP switch S1 DIP switch Fi gure 6. DIP switches S1 and S 2 at the top right. The ti me delay setti ngs are shown in Figures 6 and 7 and in T able C. The se nsor setti ngs are shown in Figure 6 and in T abl e D. The standard ( factory) settin gs are s h o w ni nT a b l e sC ,D ,a n dH . S3 DI ...

  • Emerson 185 - page 7

    CONT ROLLER Series 185 (continued) 5 381333–319 A 6 - - - Remote Contr ol F eatures These remote c ontrol feat ures r equire a custom er– sup pli e d no rma lly– clos ed co nt act s ui t able f o r a 5 V dc lo w energ y circ uit. R efer to the w iring diag ram pr ovided w i t ht h eA T S . A c t i v a t et h ea p p r o p r i a t eD I P s w i ...

  • Emerson 185 - page 8

    FU N CTIO NA L TE ST Seri es 185 6 381333–319 A After ins talling th e Series 185 autom atic trans fer switch (A TS) perfor m the fol lowing th ree–part func tional test. 1 --- M a n u a l O p e r a t i o n A hand le is provided on th e transfer sw itch for main te - nance purposes only. M a n u a l o p e r a t io n o f t he t ra n s f e r swit ...

  • Emerson 185 - page 9

    Sequence of Operat ion - - - Ut ility Failur e Seri es 185 7 381333–319 A wait 1 0 se c. for generator to warm up generator runs unloaded for 5 min. generato r starting Ut ility fails (longe r tha n 3s e c . ) generato r stops wait 1 5 min. for util ity to st abilize obser ve these power lights obser ve these swi tch lights waiting for ut ility t ...

  • Emerson 185 - page 10

    TR OUBLESHOOTING Seri es 185 8 381333–319 A This troubleshooting g uide describes some of the simple caus es of probl ems with the instal lation of the automatic transfer switch. T roubleshooting beyond the scope of this gu ide sho uld n ot be attem pted b y the instal le r. A lic ens ed elec trician must perform all internal tr oubles hooting. A ...

  • Emerson 185 - page 11

    TR OUBLESHOOTING Series 185 (continued) 9 381333–319 A Probl em Cause a nd Sol ution The A TS does not im mediatel y transfer th e load to the generator. 1. V erify that the Generator Acc epted lig ht is on . If it is off , see p revio us tro ubl e- shooting probl em. T he A TS will not transfer the load to an unacc eptable sourc e. 2. W ai t app ...

  • Emerson 185 - page 12

    INDEX Seri es 185 Printed in U .S.A. Copy right - - - ASCO Power T echn ologies, L.P . 2008 10 381333–319 A A A utomatic Generator Exerc iser, light, 2 B b a t t e r y ,c l o c k ,3 buttons, push, 2 Bypass T ime Del ay, button, 2 , 6 C cable s pa cer s, 1 cat alo g nu mber, in si de cov er cl ock batter y, 3 connections elec trical pow er, 1 engi ...

Manufacturer Emerson Category Switch

Documents that we receive from a manufacturer of a Emerson 185 can be divided into several groups. They are, among others:
- Emerson technical drawings
- 185 manuals
- Emerson product data sheets
- information booklets
- or energy labels Emerson 185
All of them are important, but the most important information from the point of view of use of the device are in the user manual Emerson 185.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Emerson 185, service manual, brief instructions and user manuals Emerson 185. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Emerson 185.

Similar manuals

A complete manual for the device Emerson 185, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Emerson 185 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Emerson 185.

A complete Emerson manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Emerson 185 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Emerson 185, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Emerson 185, that we can find in the current document
3. Tips how to use the basic functions of the device Emerson 185 - which should help us in our first steps of using Emerson 185
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Emerson 185
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Emerson 185 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Emerson 185?

Use the form below

If you did not solve your problem by using a manual Emerson 185, ask a question using the form below. If a user had a similar problem with Emerson 185 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)