Manual Lincoln Electric 10,000 PLUS

37 pages 0.94 mb
Download

Go to site of 37

Summary
  • Lincoln Electric 10,000 PLUS - page 1

    RANGER 10,000 PLUS AND RANGER 10,000 LINCOLN ELECTRIC OPERA TOR’S MANUAL For Machines with Code Number 11394, 11395, 11398 IM925 January, 2007 Safety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind. However, your overall safety can be increased by proper installation ... and thought- ful operatio ...

  • Lincoln Electric 10,000 PLUS - page 2

    FOR ENGINE powered equipment. 1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors. ________________________________________________ ...

  • Lincoln Electric 10,000 PLUS - page 3

    ii SAFETY ii ARC RA YS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards. 4.b. Use suitable clothing made from durable flame-resistant material to protect your skin ...

  • Lincoln Electric 10,000 PLUS - page 4

    FOR ELECTRICALL Y powered equipment. 8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment. 8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer’s recommendations. 8.c. Ground the equipment in accordance with the U.S. National Electrical C ...

  • Lincoln Electric 10,000 PLUS - page 5

    Mar. ‘93 iv SAFETY iv PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- antes: Sûreté Pour Soudage A L’Arc 1. Protegez-vous contre la secousse électrique: a. Les ...

  • Lincoln Electric 10,000 PLUS - page 6

    v v Thank You for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product ••• as much pride as we have in bringing this product to you! Read this Operators Manual completely before attempting to use this equipment. Save this manual and keep it handy for quick reference. Pay ...

  • Lincoln Electric 10,000 PLUS - page 7

    vi vi T ABLE OF CONTENTS Page Installation ................................................................................................................... ....Section A Technical Specifications .......................................................................................................A-1 Safety Precautions .......................... ...

  • Lincoln Electric 10,000 PLUS - page 8

    A-1 INST ALLA TION RANGER 10,000 PLUS AND RANGER 10,000 & RANGER 10,000 A-1 TECHNICAL SPECIFICA TIONS - RANGER 10,000 PLUS (K1419-5 ), (K2468-2) RANGER 10,000 (K2160-4) INPUT - GASOLINE ENGINE RA TED OUTPUT @ 104°F (40°C)- WELDER HEIGHT WIDTH DEPTH WEIGHT 30.3 in. 19.1 in. 42.0 in. 502 lbs. (228kg) K1419-5 770 mm 485 mm 1067 mm 528 lbs. (240k ...

  • Lincoln Electric 10,000 PLUS - page 9

    A-2 INST ALLA TION RANGER 10,000 PLUS AND RANGER 10,000 A-2 SAFETY PRECAUTIONS MACHINE GROUNDING Because this portable engine driven welder or genera- tor creates it’s own power, it is not necessary to con- nect it’s frame to an earth ground, unless the machine is connected to premises wiring (your home, shop, etc.). To prevent dangerous electr ...

  • Lincoln Electric 10,000 PLUS - page 10

    FUEL Fill the fuel tank with clean, fresh, lead-free gasoline. Observe fuel gauge while filling to prevent overfilling. OIL The RANGER 10,000 PLUS AND RANGER 10,000 is shipped with the engine crankcase filled with SAE 10W-30 oil. Check the oil level before starting the engine. If it is not up to the full mark on the dip stick, add oil as required. ...

  • Lincoln Electric 10,000 PLUS - page 11

    A-4 INST ALLA TION RANGER 10,000 PLUS AND RANGER 10,000 A-4 WELDING OUTPUT CABLES With the engine off, connect the electrode and work cables to the studs provided. These connections should be checked periodically and tightened if necessary. Loose con- nections will result in overheating of the output studs. When welding at a considerable distance f ...

  • Lincoln Electric 10,000 PLUS - page 12

    A-5 INST ALLA TION RANGER 10,000 PLUS AND RANGER 10,000 A-5 LOCA TION / VENTILA TION The welder should be located to provide an unrestricted flow of clean, cool air to the cooling air inlets and to avoid heated air coming out of the welder recirculating back to the cooling air inlet. Also, locate the welder so that engine exhaust fumes are properly ...

  • Lincoln Electric 10,000 PLUS - page 13

    A-6 INST ALLA TION RANGER 10,000 PLUS AND RANGER 10,000 A-6 120 V DUPLEX RECEPTACLES The 120V auxiliary power receptacles should only be used with three wire grounded type plugs or approved double insulated tools with two wire plugs. The current rating of any plug used with the system must be at least equal to the current load through the associate ...

  • Lincoln Electric 10,000 PLUS - page 14

    A-7 INST ALLA TION RANGER 10,000 PLUS AND RANGER 10,000 A-7 TABLE lll ELECTRICAL DEVICE USE WITH THE RANGER 10,000 PLUS & RANGER 10,000. Type Common Electrical Devices Possible Concerns Resistive Heaters, toasters, incandescent NONE light bulbs, electric range, hot pan, skillet, coffee maker. Capacitive TV sets, radios, microwaves, Voltage spik ...

  • Lincoln Electric 10,000 PLUS - page 15

    A-8 INST ALLA TION RANGER 10,000 PLUS AND RANGER 10,000 A-8 STANDBY POWER CONNECTIONS The RANGER 10,000 PLUS AND RANGER 10,000 are suitable for temporary, standby, or emergency power using the engine manufacturer ’ s recommended maintenance schedule. The RANGER 10,000 PLUS AND RANGER 10,000 can be permanently installed as a standby power unit for ...

  • Lincoln Electric 10,000 PLUS - page 16

    240 Volt 60 Hz. 3-Wire Service POWER COMPANY METER 240 VOLT 120 VOLT 120 VOLT LOAD N NEUTRAL BUS GROUND PREMISES DISCONNECT AND SERVICE OVERCURRENT PROTECTION GND N NOTE: No. 6 COPPER CONDUCTOR CABLE SEE NATIONAL ELECTRICAL CODE FOR ALTERNATE WIRE SIZE RECOMMENDATIONS. 240 VOLT GROUNDED CONDUCTOR 40 AMP 240 VOLT DOUBLE POLE CIRCUIT BREAKER DOUBLE P ...

  • Lincoln Electric 10,000 PLUS - page 17

    WELDER CONTROLS - FUNCTION AND OPERA TION ENGINE SWITCH The engine switch is used to Start the Engine, Select High Idle or Auto Idle while the engine is running, and stop the Engine. When placed in the “ OFF ” position, the ignition circuit is de-energized to shut down the engine. When held in the “ START ” position, the engine starter moto ...

  • Lincoln Electric 10,000 PLUS - page 18

    “ RANGE ” SWITCH The “ Range ” switch is used to select one of three amperage ranges with generous overlap for Stick/TIG welding, or one Wire Feed welding range. Never change the “ RANGE ” Switch setting while welding. This will damage the switch. ------------------------------------------------------------------------ “ CONTROL ” D ...

  • Lincoln Electric 10,000 PLUS - page 19

    B-3 OPERA TION B-3 ST ARTING/SHUTDOWN INSTRUCTIONS STARTING THE ENGINE Be sure all Pre-Operation Maintenance has been per- formed. Also, read the Engine Owner ’ s Manual before starting for the first time . Remove all loads connected to the AC power recepta- cles. Use the choke control as follows: KOHLER ENGINE - Always pull the choke control out ...

  • Lincoln Electric 10,000 PLUS - page 20

    B-4 OPERA TION B-4 WELDING PROCESS For any electrodes the procedures should be kept within the rating of the machine. For electrode information see the appropriate Lincoln publication. STICK (CONSTANT CURRENT) WELDING Connect welding cables to the "TO WORK ” and "ELEC- TRODE ” studs. Start the engine. Set the "Polarity ” switch ...

  • Lincoln Electric 10,000 PLUS - page 21

    B-5 OPERA TION B-5 RANGER 10,000 PLUS AND RANGER 10,000 SUMMARY OF WELDING PROCESSES CONTROL ELECTRODE CABLE IDLE WHEN NOT TO START PROCESS USED MODE WELDING WELDING STICK No AUTO Hot Touch electrode to work. Welding starts immediately and engine goes to high idle. WIRE FEED, LN-25 WITH No AUTO Cold Press gun trigger, LN-25 INTERNAL CONTACTOR conta ...

  • Lincoln Electric 10,000 PLUS - page 22

    C-1 ACCESSORIES C-1 RANGER 10,000 PLUS AND RANGER 10,000 OPTIONAL EQUIPMENT (Field Installed) K957-1 HEAVY DUTY, TWO WHEEL TRAILER FOR SMALL WELDERS - For road, off-road and in-plant and yard towing. (For highway use, consult applicable federal, state and local laws regarding requirements for brakes, lights, fenders, etc.) Order K957-1 Trailer K958 ...

  • Lincoln Electric 10,000 PLUS - page 23

    C-2 ACCESSORIES C-2 RANGER 10,000 PLUS AND RANGER 10,000 RECOMMENDED EQUIPMENT STICK K704 ACCESSORY SET - Includes 35 ft. (10m) of electrode cable and 30 ft. (9.1m) of work cable, head- shield, work clamp electrode holder. Cables are rated at 400 amps, 100% duty cycle. K875 Accessory Kit - For stick welding. Includes 20 Ft. (6.1m). #6 electrode cab ...

  • Lincoln Electric 10,000 PLUS - page 24

    Have qualified personnel do the maintenance work. Turn the engine off before working inside the machine. In some cases, it may be necessary to remove safety guards to perform required maintenance. Remove guards only when necessary and replace them when the mainte- nance requiring their removal is complete. Always use the greatest care when working ...

  • Lincoln Electric 10,000 PLUS - page 25

    D-2 MAINTENANCE D-2 Use 4-stroke motor oil that meets or exceeds the requirements for API service classification SG or SH. Always check the API SERVICE label on the oil con- tainer to be sure it includes the letters SG or SH. SAE 10W-30 is recommended for general, all-tempera- ture use, -5 F to 104 F (-20 C to 40 C). See Engine Owner ’ s Manual f ...

  • Lincoln Electric 10,000 PLUS - page 26

    D-3 MAINTENANCE D-3 ENGINE ADJUSTMENTS OVERSPEED IS HAZARDOUS The maximum allowable high idle speed for this machine is 3750 RPM, no load. Do NOT tamper with governor components or setting or make any other adjustments to increase the maximum speed. Severe personal injury and damage to the machine can result if operated at speeds above maximum. --- ...

  • Lincoln Electric 10,000 PLUS - page 27

    E-1 TROUBLESHOOTING E-1 RANGER 10,000 PLUS AND RANGER 10,000 If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION This Troubleshooting Guide is provided to help y ...

  • Lincoln Electric 10,000 PLUS - page 28

    E-2 TROUBLESHOOTING E-2 RANGER 10,000 PLUS AND RANGER 10,000 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you pro ...

  • Lincoln Electric 10,000 PLUS - page 29

    E-3 TROUBLESHOOTING E-3 RANGER 10,000 PLUS AND RANGER 10,000 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you pro ...

  • Lincoln Electric 10,000 PLUS - page 30

    F-1 DIAGRAMS F-1 RANGER 10,000 PLUS AND RANGER 10,000 NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a replacement. Give t ...

  • Lincoln Electric 10,000 PLUS - page 31

    F-2 DIAGRAMS F-2 RANGER 10,000 PLUS AND RANGER 10,000 NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a replacement. Give t ...

  • Lincoln Electric 10,000 PLUS - page 32

    F-3 DIAGRAMS F-3 RANGER 10,000 PLUS AND RANGER 10,000 / / L L N -15 RANGER 10,000 PLUS AND RANGER 10,000 R A N G E R 10 , 0 0 0 P LU S A ND R A N G E R 1 0, 00 0 AND LN-25 ACROSS T A ND L N- 25 A CR OS S T H E ARC CONNECT E AR C C ON NE C T I O N DI N DI A G R A M ELECTRIC SHOCK can kill Do not operate with panels open. Disconnect NEGATIVE (-) Batt ...

  • Lincoln Electric 10,000 PLUS - page 33

    F-4 DIAGRAMS F-4 RANGER 10,000 PLUS AND RANGER 10,000 KOHLER, HONDA AND SUBARU ROBIN M20267 C. 01 26.5 9 30.2 7 9.09 9.09 17.0 0 21.2 2 8.80 30.0 0 42.0 0 22.1 5 10.3 3 CE NTER OF GR AV ITY WITH OIL I N ENGI N E A ND FULL FUEL TAN K 9.31 CE NTERLI NE OF S HAFT 9.59 10.1 9 OIL FIL TER REMO VAL NOTE: CASEFRONT GRAPHICS MAY NOT MATCH AL L CODES. 42.2 ...

  • Lincoln Electric 10,000 PLUS - page 34

    NOTES RANGER 10,000 PLUS AND RANGER 10,000 ...

  • Lincoln Electric 10,000 PLUS - page 35

    W ARNING A VISO DE PRECAUCION A TTENTION W ARNUNG A TEN ÇÃ O Spanish French German Portuguese Japanese Chinese Korean Arabic READ AND UNDERST AND THE MANUF ACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES. SE RECOMIENDA LEER Y ENTENDER LAS INSTRUCCIONES DEL F ABRICANTE PARA EL ...

  • Lincoln Electric 10,000 PLUS - page 36

    W ARNING A VISO DE PRECAUCION A TTENTION W ARNUNG A TEN ÇÃ O Spanish French German Portuguese Japanese Chinese Korean Arabic LEIA E COMPREENDA AS INSTRUÇÕES DO F ABRICANTE PARA ESTE EQUIP AMENTO E AS P ARTES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR. ● Keep your head out of fumes. ● Use ventilation or exhaust to remove fumes f ...

  • Lincoln Electric 10,000 PLUS - page 37

    • Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com • World's Leader in Welding and Cutting Products • ...

Manufacturer Lincoln Electric Category Welder

Documents that we receive from a manufacturer of a Lincoln Electric 10,000 PLUS can be divided into several groups. They are, among others:
- Lincoln Electric technical drawings
- 10,000 PLUS manuals
- Lincoln Electric product data sheets
- information booklets
- or energy labels Lincoln Electric 10,000 PLUS
All of them are important, but the most important information from the point of view of use of the device are in the user manual Lincoln Electric 10,000 PLUS.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Lincoln Electric 10,000 PLUS, service manual, brief instructions and user manuals Lincoln Electric 10,000 PLUS. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Lincoln Electric 10,000 PLUS.

A complete manual for the device Lincoln Electric 10,000 PLUS, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Lincoln Electric 10,000 PLUS by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Lincoln Electric 10,000 PLUS.

A complete Lincoln Electric manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Lincoln Electric 10,000 PLUS - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Lincoln Electric 10,000 PLUS, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Lincoln Electric 10,000 PLUS, that we can find in the current document
3. Tips how to use the basic functions of the device Lincoln Electric 10,000 PLUS - which should help us in our first steps of using Lincoln Electric 10,000 PLUS
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Lincoln Electric 10,000 PLUS
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Lincoln Electric 10,000 PLUS in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Lincoln Electric 10,000 PLUS?

Use the form below

If you did not solve your problem by using a manual Lincoln Electric 10,000 PLUS, ask a question using the form below. If a user had a similar problem with Lincoln Electric 10,000 PLUS it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)