Manual Rheem RSNA-B Series

40 pages 2.27 mb
Download

Go to site of 40

Summary
  • Rheem RSNA-B Series - page 1

    FORM NO. S1 1-933 REV . 2 Supersedes Form No. S1 1-933 Rev . 1 RSNA-B SUPER HIGH EFFICIENCY 1 3-SEER SERIES NOMINAL SIZES 2-5 TONS [7 .0-1 7 .6 kW] P ACKAGE A IR C ONDITIONERS ...

  • Rheem RSNA-B Series - page 2

    2 T ABLE OF CONTENTS Unit Features & Benefits ..............................................................................3-4 Model Identification Options ..........................................................................5 - 6 General Data RSNA-B Series .................................................................................. ...

  • Rheem RSNA-B Series - page 3

    3 UNIT FEA TURES & BENEFITS—RSNA-B These qualit y feature s are inc luded in the Rhe em P acka ge Air Conditioner 5 ...

  • Rheem RSNA-B Series - page 4

    4 UNIT FEA TURES & BENEFITS—RSNA-B SERIES 1. All models feature Copeland ® Scroll ® compressors for maxi- mum efficiency and quiet operation. 2. Louvered condenser compartment for protecting the coil against yard hazards and/or weather extremes. 3. One-piece top with a drip lip to help keep water off of the unit sides. 4. Supply and return ...

  • Rheem RSNA-B Series - page 5

    R S N A — B 036 J K 010 X X Factory Installed Options (See Next Page) Heating Capacity (Factory Installed) 000 = No Resistance Heat 005 = 05 KW Resistance Heat (018-030) 010 = 10 KW Resistance Heat (024-048) 015 = 15 KW Resistance Heat (036-048) Drive Package K = Direct Drive Electrical Designation J = 208-230V—1PH—60 Hz C = 208-230V—3PH— ...

  • Rheem RSNA-B Series - page 6

    6 OPTIONS—RSNA-B SERIES Option Code Side Flow AA No Option AK x F A CT OR Y INST ALLED OPTION CODES Example: RSNA-B036JK000 XX (where XX is factory installed option) Example: No Options RSNA-B036JK000 Example: Options with Sideflow RSNA-B036JK000AK Note: Factory installed economizer is not available on these models. Instructions f or F actory Ins ...

  • Rheem RSNA-B Series - page 7

    7 GENERAL DA T A—RSNA-B SERIES Model RSNA-B Series B024JK B030JK B036CK B036JK Cooling Performance 1 Gross Cooling Capacity Btu [kW] 24,800 [7.27] 31,200 [9.14] 37,400 [10.96] 37,400 [10.96] EER/SEER 2 11.8/13 11.1/13 11.7/13 11.7/13 Nominal CFM/ARI Rated CFM [L/s] 800/800 [378/378] 1000/1000 [472/472] 1200/1200 [566/566] 1200/1200 [566/566] ARI ...

  • Rheem RSNA-B Series - page 8

    8 GENERAL DA T A—RSNA-B SERIES Model RSNA-B Series B042CK B042JK B048CK B048JK Cooling Performance 1 Gross Cooling Capacity Btu [kW] 42,500 [12.45] 42,500 [12.45] 50,500 [14.8] 50,500 [14.8] EER/SEER 2 11.5/13 11.5/13 11.6/13 11.6/13 Nominal CFM/ARI Rated CFM [L/s] 1400/1350 [661/637] 1400/1350 [661/637] 1600/1600 [755/755] 1600/1600 [755/755] AR ...

  • Rheem RSNA-B Series - page 9

    9 GENERAL DA T A—RSNA-B SERIES Model RSNA-B Series B060CK B060JK Cooling Performance 1 Gross Cooling Capacity Btu [kW] 60,000 [17.58] 60,000 [17.58] EER/SEER 2 11.1/13 11.1/13 Nominal CFM/ARI Rated CFM [L/s] 2000/1850 [897/873] 2000/1850 [897/873] ARI Net Cooling Capacity Btu [kW] 58,000 [16.99] 58,000 [16.99] Net Sensible Capacity Btu [kW] 40,56 ...

  • Rheem RSNA-B Series - page 10

    10 GENERAL DA T A—RSNA-B SERIES NO TES: 1. Cooling Performance is rated at 95° F ambient, 80° F entering dry bulb, 67° F entering wet bulb. Gross capacity does not include the effect of fan motor heat. ARI capacity is net and includes the effect of fan motor heat. Units are suitable for operation to  20% of nominal cfm. Units are certified ...

  • Rheem RSNA-B Series - page 11

    11 SYSTEMS PERFORMANCE—RSNA-B SERIES GR OSS SYSTEMS PERFORMANCE D A T A—RSNA-B024 ENTERING INDOOR AIR @ 80°F [26.7°C] dbE ➀ wbE 71°F [21.7°C] 67°F [19.4°C] 63°F [17.2°C] CFM [L/s] 880 [415] 800 [378] 680 [321] 880 [415] 800 [378] 680 [321] 880 [415] 800 [378] 680 [321] DR ➀ .21 .20 .18 .21 .20 .18 .21 .20 .18 O U T D O O R D R Y B U ...

  • Rheem RSNA-B Series - page 12

    12 SYSTEMS PERFORMANCE—RSNA-B SERIES GR OSS SYSTEMS PERFORMANCE D A T A—RSNA-B036 ENTERING INDOOR AIR @ 80°F [26.7°C] dbE ➀ wbE 71°F [21.7°C] 67°F [19.4°C] 63°F [17.2°C] CFM [L/s] 1320 [623] 1200 [566] 1020 [481] 1320 [623] 1200 [566] 1020 [481] 1320 [623] 1200 [566] 1020 [481] DR ➀ .21 .20 .17 .21 .20 .17 .21 .20 .17 O U T D O O R ...

  • Rheem RSNA-B Series - page 13

    GR OSS SYSTEMS PERFORMANCE D A T A—RSNA-B048 ENTERING INDOOR AIR @ 80°F [26.7°C] dbE ➀ wbE 71°F [21.7°C] 67°F [19.4°C] 63°F [17.2°C] CFM [L/s] 1760 [831] 1600 [755] 1360 [642] 1760 [831] 1600 [755] 1360 [642] 1760 [831] 1600 [755] 1360 [642] DR ➀ .20 .19 .17 .20 .19 .17 .20 .19 .17 O U T D O O R D R Y B U L B T E M P E R A T U R E °F ...

  • Rheem RSNA-B Series - page 14

    INDOOR AIRFLO W PERFORMANCE—208 V OL TS External Static Pressure—Inches W .C. [kPa] CFM [L/s] Air Delivery/RPM/Watts—208 Volts Side Discharge—Wet Coil Nominal Cooling Capacity T ons [kW] Motor Speed from Factory Motor Speed RPM 730 775 820 865 905 940 0.1 [.02] 0.2 [.05] 0.3 [.07] 0.4 [.10] 0.5 [.12] 0.6 [.15] 0.7 [.17] 975 RPM 695 785 870 ...

  • Rheem RSNA-B Series - page 15

    15 AIRFLOW PERFORMANCE—RSNA-B SERIES INDOOR AIRFLO W PERFORMANCE—230 V OL TS External Static Pressure—Inches W .C. [kPa] CFM [L/s] Air Delivery/RPM/Watts—230 Volts Side Discharge—Wet Coil Blower Size/ Motor HP [W] & # of Speeds Nominal Cooling Capacity T ons [kW] Motor Speed from Factory Motor Speed 10x9 1 HP ECM (Constant CFM) RPM 76 ...

  • Rheem RSNA-B Series - page 16

    ELECTRICAL DA T A – RSNA-B SERIES Minimum Circuit Ampacity Minimum Overcurrent Protection Device Size 16/16 20/20 Maximum Overcurrent Protection Device Size 25/25 Compressor Motor No. 1 Volts 208/230 Phase 1 HP 2 1/6 RPM 3450 Amps (RLA) 10.4/10.4 Amps (LRA) Unit Information Unit Operating Voltage Range 54/54 187-253 Condenser Motor No. 1 Volts 20 ...

  • Rheem RSNA-B Series - page 17

    B024JK No Heat — — 16/16 20/25 20/25 A10J 24.57/32.76 34.6/40.0 45/52 45/45 60/60 A05J 12.28/16.38 17.3/20.0 24/27 25/25 30/30 44/50 45/50 — — — — — 16/16 20/25 20/25 22/25 25/25 — — — RXQJ- Heater Kit Nominal kW Heater KBTU/Hr @ 208/240 V Heater Amp. @ 208/240 V Unit Min. Ckt. Ampacity @ 208/240 V Over Current Protective Device ...

  • Rheem RSNA-B Series - page 18

    30% 2% 21% 2% 29% 2% 20% 2% CORNER WEIGHTS % OF TO T AL UNIT WEIGHT THERMOST A T WIRING ENTRANCE ELECTRICAL POWER ENTRANCE BLOWER/ EV APORA T OR ACCESS P ANEL SIDE SUPPL Y DUCT OPENING SIDE RETURN DUCT OPENING TOP COVER UNIT DIMENSIONS P A CKA GE AIR CONDITIONERS OUTDOOR F AN GRILLE AND COMPRESSOR ACCESS CONTROL ACCESS P ANEL LIQUID PRESSURE SERVIC ...

  • Rheem RSNA-B Series - page 19

    52 7 / 16 " [1332 mm] FIL TER ACCESS P ANEL (FOR UNIT MOUNTED FIL TER ACCESSOR Y BLOWER/ EV APORA TOR ACCESS P ANEL OUTDOOR COIL PROTECTIVE GRILLE 25 5 / 16 " [643 mm] 10 3 / 16 " [259 mm] 4 3 / 4 " [121 mm] 5 1 / 16 " [129 mm] 1 1 / 8 " [28.6 mm] THERMOST A T WIRE ENTRANCE ELECTRICAL POWER ENTRANCE SIDE VIEW SIDE VIEW ...

  • Rheem RSNA-B Series - page 20

    20 TYPICAL INST ALLA TIONS ...

  • Rheem RSNA-B Series - page 21

    COMMON SUPPL Y/RETURN CONCENTRIC AIR DIFFUSER SUPPL Y AIR/PERFORMANCE NO TE: The location of the combination supply and return diffuser should not exceed 10 feet [3.05 m] above the floor level for units @ 1000 CFM [472 L/s] or less and 12 [3.66 m] to 14 feet [4.27 m] above the floor level for units with CFM greater than 1000 [472 L/s]. If the diffu ...

  • Rheem RSNA-B Series - page 22

    DUCT AD APTERS RECT ANGULAR T O R OUND TRANSITIONS (DO WNFLO W) RXMC-CA03 RXMC-CA02 [ ] Designates Metric Con versions 22 ACCESSORIES ...

  • Rheem RSNA-B Series - page 23

    [ ] Designates Metric Con versions RXRE-CAA30 (3 P osition) Provided with enthalpy control, and mixed air sensor . Settings include fully open, fully closed and adjustable mid point. RXRD-CAM1 0 (Fully Modulating) Provided with enthalpy control, mixed air sensor and minimum position poten- tiometer for proportioning (modulating) the amount of fresh ...

  • Rheem RSNA-B Series - page 24

    CFM [L/s] RSNA-B 680 [321] RSNA-B 850 [401] RSNA-B 1020 [481] RSNA-B 1190 [562] RSNA-B 1275 [602] 1500 [708] 1400 [661] 1200 [566] 1000 [472] 800 [378] 1650 [779] 1540 [727] 1320 [623] 1100 [519] 880 [415] Minimum Airflow Model No. Nominal Airflow Maximum Airflow 510 [241] RSNA-B 600 [283] 660 [311] Airflow Pressure Drop, Inches W .C. [kPa] 1" ...

  • Rheem RSNA-B Series - page 25

    DUCT AD APTER SIDEFLO W SQU ARE T O R OUND TRANSITION RXMC-B A01 Adapts the side rectangular supply and return openings to 14" [356 mm] diameter round openings. Adapters provided with same finish as unit and also provided with thermal insulation. 25 ACCESSORIES ...

  • Rheem RSNA-B Series - page 26

    RXSG-AAA 14 (1 4" [356 mm] High) RXSG-AAA08 (8" [203 mm] High) R OOFCURB (Full P erimeter) RXSG-AAA08, RXSG-AAA 1 4 and RXSG-AAA24 for RSNA-B Series Hinged corners make for fast, easy set-up. NO T f or use with RQKA/RQLA/RQMA P acka ge Heat Pumps. [ ] Designates Metric Con versions 26 ACCESSORIES ...

  • Rheem RSNA-B Series - page 27

    R OOFCURB (Full P erimeter) (Cont.) [ ] Designates Metric Con versions RXSG-AAA24 (24" [610 mm] High) 27 ACCESSORIES ...

  • Rheem RSNA-B Series - page 28

    [ ] Designates Metric Con versions P A CKA GE AIR CONDITIONERS & GAS/ELECTRIC P A CKA GE UNITS R OOFCURB INST ALLA TION (Full P erimeter) OLD MODEL OLD CURB MODEL NEW MODEL TO OLD MODEL ROOFCURB AD APTER NEW MODEL P ACKA GE ONL Y 1 CABINET SIZE — ALL MODELS RSNA-B SMALL CABINET 20 SERIES RXPX-BACCA20 RXRX-BACDB20 RXPX-BACCA21 RXRX-BACDB21 RXP ...

  • Rheem RSNA-B Series - page 29

    LIFT KIT—MODEL NO . RXML-A01 The lift kit is intended for temporary installation while the unit is being lifted into position. Kit includes 4 lift brackets. 29 ACCESSORIES ...

  • Rheem RSNA-B Series - page 30

    W ARNING ONL Y ELECTRIC HEA TER KITS SUPPLIED BY THIS MANUF ACTURER AS DESCRIBED IN THIS PUBLICA TION HA VE BEEN DESIGNED, TESTED, AND EV ALU A TED BY A NA TIONALL Y RECOGNIZED SAFETY TESTING A GENCY FOR USE WITH THIS UNIT . USE OF ANY O THER MANUF A CTURED ELECTRIC HEA TERS INST ALLED WITHIN THIS UNIT MA Y CAUSE HAZARDOUS CONDITIONS RESUL TING IN ...

  • Rheem RSNA-B Series - page 31

    31 WIRING SCHEMA TICS—RSNA-B SERIES ...

  • Rheem RSNA-B Series - page 32

    32 WIRING SCHEMA TICS—RSNA-B SERIES ...

  • Rheem RSNA-B Series - page 33

    33 WIRING SCHEMA TICS—RSNA-B SERIES ...

  • Rheem RSNA-B Series - page 34

    34 WIRING SCHEMA TICS—RSNA-B SERIES ...

  • Rheem RSNA-B Series - page 35

    35 WIRING SCHEMA TICS—RSNA-B SERIES ...

  • Rheem RSNA-B Series - page 36

    36 WIRING SCHEMA TICS—RSNA-B SERIES ...

  • Rheem RSNA-B Series - page 37

    37 NOTES ...

  • Rheem RSNA-B Series - page 38

    38 NOTES ...

  • Rheem RSNA-B Series - page 39

    39 NOTES ...

  • Rheem RSNA-B Series - page 40

    Before pr oceeding with installation, refer to installation instructions packaged with each model, as well as complying with all Federal, State, Pro vincial, and Local codes, regulations, and practices. RHEEM AIR CONDITIONING DIVISION 5600 Old Greenwood Road, Fort Smith, Arkansas 72908 “In keeping with its policy of contin uous progress and produ ...

Manufacturer Rheem Category Air Conditioner

Documents that we receive from a manufacturer of a Rheem RSNA-B Series can be divided into several groups. They are, among others:
- Rheem technical drawings
- RSNA-B Series manuals
- Rheem product data sheets
- information booklets
- or energy labels Rheem RSNA-B Series
All of them are important, but the most important information from the point of view of use of the device are in the user manual Rheem RSNA-B Series.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Rheem RSNA-B Series, service manual, brief instructions and user manuals Rheem RSNA-B Series. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Rheem RSNA-B Series.

Similar manuals

A complete manual for the device Rheem RSNA-B Series, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Rheem RSNA-B Series by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Rheem RSNA-B Series.

A complete Rheem manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Rheem RSNA-B Series - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Rheem RSNA-B Series, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Rheem RSNA-B Series, that we can find in the current document
3. Tips how to use the basic functions of the device Rheem RSNA-B Series - which should help us in our first steps of using Rheem RSNA-B Series
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Rheem RSNA-B Series
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Rheem RSNA-B Series in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Rheem RSNA-B Series?

Use the form below

If you did not solve your problem by using a manual Rheem RSNA-B Series, ask a question using the form below. If a user had a similar problem with Rheem RSNA-B Series it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)