Manual Dimplex BF39ST/DX

24 pages 0.81 mb
Download

Go to site of 24

Summary
  • Dimplex BF39ST/DX - page 1

    INSTALLATION GUIDE FOR THE ELECTRIC FIREPLACE MODEL NUMBERS: BF33ST/DX BF39ST/DX BF45ST/DX 7206350200REV06 ...

  • Dimplex BF39ST/DX - page 2

    CONTENTS PAGE 1 Listings and Code Approvals PAGE 1 Model Specifications PAGE 1 Step-by-Step Installation Section A P A G E 2 F r a m i n g Section B PAGE 2 Recommended Power Supply Wire Specifications PAGE 2 Recommended Wire and Fusing Requirements PAGE 3 Voltage Selector Switch Location PAGE 3 Mounting Flanges Section C PAGE 4 Factory Setting Wiri ...

  • Dimplex BF39ST/DX - page 3

    LISTINGS AND CODE APPROVALS The BF series fireplaces have been tested in acco rdance with the UL 2021 and CSA C22.2 No. 46 standards for fixed and location-dedicated ele ctric ro om heaters. MODEL SPECIFICATIONS Model Number Description Voltage Volts Rated Power Watts Remote Control Wall Thermostat Refractory Brick Look AMPS No Heat 120 Volt AMPS 1 ...

  • Dimplex BF39ST/DX - page 4

    WARNING Ensure method of installation does NOT obscure the air intake slots on bottom front of unit in any manner. (see diagram in Section A) SECTION A: FRAMING Dimensions This firepl ace is a zer o clear ance des ign. No comb ustibl es can be placed on the top surface of the fireplace. Combustibles may be installed to the edge of the unit. F our m ...

  • Dimplex BF39ST/DX - page 5

    VOLTAGE SELECTOR SWITCH LOCATION IMPORTANT: Ensure that the incoming power supply voltage matches the setting of the voltage selector switch. NOTE: The voltage selector switch is located inside the exhaust panel on the top right hand corner. CAUTION: When changing the voltage selector switch from 240 volts to 120 volts ensure that the power supply ...

  • Dimplex BF39ST/DX - page 6

    SECTION C: FACTORY SETTING WIRING (WITHOUT MAIN POWER WALL SWITCH) IMPORTANT: The unit is factory confi gured for 208/240 volt operation NOTE: Use 3 conductor wire with ground (4 wires total) from the power supply (breaker panel) to the junction box on the unit. NOTE: All wiring must be completed prior to installing the unit. NOTE: Ensure that the ...

  • Dimplex BF39ST/DX - page 7

    SECTION C: FACTORY SETTING WIRING (WITHOUT MAIN PO WER WALL SWITCH) IMPORTANT: The unit is factory confi gured for 208/240 volt operation NOTE: Use 2 conductor wire with ground (3 wires total) from the power supply (breaker panel) to the junction box on the unit. NOTE: All wiring must be completed prior to installing the unit. NOTE: Ensure that the ...

  • Dimplex BF39ST/DX - page 8

    SECTION C: FACTORY SETTING WIRING (WITHOUT MAIN PO WER WALL SWITCH) (NO HEAT INSTALLATION) IMPORTANT: The unit is factory confi gured for 208/240 volt operation NOTE: Use 2 conductor wire with ground (3 wires total) from the power supply (breaker panel) to the junction box on the unit. NOTE: All wiring must be completed prior to installing the unit ...

  • Dimplex BF39ST/DX - page 9

    SECTION D: MAIN POWER WALL SWITCH WIRING OPTI ONS MAIN POWER WALL SWITCH WIRING FOR 240 VOLT NOTE: This option should not be used with the remote control kit. NOTE: Before installing the unit you must have the following wires installed: 1. A 3 conductor wire with ground (4 wires to tal) from the power supply panel to the main switch wall box. 2. A ...

  • Dimplex BF39ST/DX - page 10

    240 VOLT MAIN WALL SWITCH WIRING DIAGRAM 8 FIREPLACE JUNCTION BO X 240 V POWER SUPPLY (BREAKER PANEL) WHITE - N RED – L2 BLACK – L1 WHITE – N BLACK – L1 GROUND - G WALL SWITCH RED – L2 GROUND - G ...

  • Dimplex BF39ST/DX - page 11

    MAIN POWER WALL SWITCH WIRING FOR 120 VOLT NOTE: This option should not be used with the remote control kit. NOTE: Before installing the unit have the following wires installed: 1. A 2 conductor wire with ground (3 wires tota l) from the power supply panel to the main switch wall box. 2. A 2 conductor wire with ground (3 wires total) from the main ...

  • Dimplex BF39ST/DX - page 12

    120 VOLT MAIN WALL SWITCH WIRING DIAGRAM 10 FIREPLACE JUNCTION BO X 120 V POWER SUPPLY (BREAKER PANEL) WHITE - N RED – L2 BLACK – L1 WHITE – N BLACK – L1 GROUND - G WALL SWITCH GROUND - G ...

  • Dimplex BF39ST/DX - page 13

    MAIN POWER WALL SWITCH WIRING FOR 120 VOLT NO HEAT INSTALLATION NOTE: This option should not be used with the remote control kit. NOTE: Before installing the unit have the following wires installed: 3. A 2 conductor wire with ground (3 wires total) from the power supply panel to the main switch wall box. 4. A 2 conductor wire with ground (3 wires t ...

  • Dimplex BF39ST/DX - page 14

    120 VOLT MAIN WALL SWITCH WIRING DIAGRAM NO HEAT INSTALLATION FIREPLACE JUNCTION BO X 120 V POWER SUPPLY (BREAKER PANEL) WHITE - N RED – L2 BLACK – L1 WHITE – N BLACK – L1 GROUND - G WALL SWITCH GROUND - G Wire Nut 12 ...

  • Dimplex BF39ST/DX - page 15

    SECTION E: HEATER WALL SWITCH AND WALL THERMOSTAT WIRING OPTIONS HEATER WALL SWITCH WIRING FOR 120/240 VOLT NOTE: Before installing the unit complete the following: 1. Install main power connection with appr opriate voltage as per Section C or Section D. 2. Install a 2 conductor wire with ground (3 wires total) from the h eater switch wall box to t ...

  • Dimplex BF39ST/DX - page 16

    HEATER WALL SWITCH WIRING DIAGRAM FOR 120/240 VOLT (SEE SECTION C OR SECTION D FOR MAIN POWER CONNECTION) 14 FIREPLACE JUNCTION BOX RED – 2 WALL SWITCH RED – 1 GROUND - G ...

  • Dimplex BF39ST/DX - page 17

    WALL MOUNTED THERMOSTAT WIRING FOR 120/240 VOLT NOTE: Before installing the unit complete the following: 1. Install main power connection with appr opriate voltage as per Section C or Section D. 2. Install a 2 conductor wire with ground (3 wires total) from the thermo stat wall box to the junction box on the unit. NOTE: Wiring of the thermostat mus ...

  • Dimplex BF39ST/DX - page 18

    WALL MOUNTED THERMOSTAT WIRING DIAGRAM FOR 120/240 VOLT (SEE SECTION C OR SECTION D FOR MAIN POWER CONNECTION) 16 FIREPLACE JUNCTION BOX WALL THERMOSTAT RED – 1 GROUND - G RED – 2 CONNECT GROUND TO WALL B OX ...

  • Dimplex BF39ST/DX - page 19

    FLAME OVERRIDE SWITCH WIRI NG FOR 120/240 VOLT NOT AVAILABLE WITH NO HEAT INSTALLATION NOTE: The fireplace can be wired to have a wall switch operate the heater indepen dent of the flame . NOTE: Before installing the unit complete the following: 1. Install main power connection with appr opriate voltage as per Section C or Section D. 2. Install a 2 ...

  • Dimplex BF39ST/DX - page 20

    FLAME OVERRIDE WALL SWITCH WIRING DIAGRAM FOR 120/240 VOLT (SEE SECTION C OR SECTION D FOR MAIN POWER C0NNECTION) NOT AVAILABLE WITH NO HEAT INSTALLATION FIREPLACE JUNCTION BOX BLUE – 4 WALL SWITCH BLUE – 3 GROUND - G 18 ...

  • Dimplex BF39ST/DX - page 21

    WIRING DIAGRAM LOWER SECTION 19 BLACK WHITE BROWN CITOR BYPASS HARNESS LOWER HARNESS WHITE ORANGE FROM TOP BROWN FROM TOP RED FROM TOP BLUE (3) MOTOR FLICKER TWIST-TIE RED RED 2 1 RED (L2) HEATER SWIT CH BLACK (L1) WHITE (N) GREEN WHITE (N) BLACK BLUE (4) RED (1) MARR MARR SWITCH MAIN BLACK (L1) 4B 5B 1A 2A RED (2) CAPA- BLACK BLUE WHITE WHITE G RE ...

  • Dimplex BF39ST/DX - page 22

    WIRING DIAGRAM UPPER SECTION 20 CUT-OUT M ELEMENT #2 ELEMENT #1 2 6 4 1 5 3 BLOW ER WH EEL BLW. MOTOR BROWN ORANGE RED (CUT-OUT LONG WIRE) BLK YLW BLK BLK YLW BLK BLK BLK YLW RED (CUT-OUT SHORT WIRE) ...

  • Dimplex BF39ST/DX - page 23

    WIRING SCHEMATIC 21 ...

  • Dimplex BF39ST/DX - page 24

    1367 Industrial Road Cambridge, Ontario Canada, N1R 7G8 1-888-DIMPLEX 1-888-346-7539 Approved for use in the United States an d Can ada ...

Manufacturer Dimplex Category Fire Pit

Documents that we receive from a manufacturer of a Dimplex BF39ST/DX can be divided into several groups. They are, among others:
- Dimplex technical drawings
- BF39ST/DX manuals
- Dimplex product data sheets
- information booklets
- or energy labels Dimplex BF39ST/DX
All of them are important, but the most important information from the point of view of use of the device are in the user manual Dimplex BF39ST/DX.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Dimplex BF39ST/DX, service manual, brief instructions and user manuals Dimplex BF39ST/DX. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Dimplex BF39ST/DX.

Similar manuals

A complete manual for the device Dimplex BF39ST/DX, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Dimplex BF39ST/DX by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Dimplex BF39ST/DX.

A complete Dimplex manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Dimplex BF39ST/DX - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Dimplex BF39ST/DX, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Dimplex BF39ST/DX, that we can find in the current document
3. Tips how to use the basic functions of the device Dimplex BF39ST/DX - which should help us in our first steps of using Dimplex BF39ST/DX
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Dimplex BF39ST/DX
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Dimplex BF39ST/DX in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Dimplex BF39ST/DX?

Use the form below

If you did not solve your problem by using a manual Dimplex BF39ST/DX, ask a question using the form below. If a user had a similar problem with Dimplex BF39ST/DX it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)