Manual Pyle PAH1

8 pages Not applicable
Download

Go to site of 8

Summary
  • Pyle PAH1 - page 1

    (E lt - Art No . : PYLE_SPORTS · PAH1 PROFESSIONAL DIGITAL ALTIMETER ----ALL·in-0NE • • ...

  • Pyle PAH1 - page 2

    FEATURES A lti meter - Al t i tude Range (- 500 to 9000 meter 1 -1 600 to 29500 feet), Resolution of 1 meter 1 1 feet - Max.' M i n . memory for Alt i tude - Al titude Hi story and Graphica l display of the l ast 12 hour al titude read i ngs - Alt i tude Al arm - Stop Watch up to 9 hr 59 m i n 59.9 sec - Alt i tude tota l gain or loss 44999 me ...

  • Pyle PAH1 - page 3

    Icons: tBlI - Altimeter mode TOT - Altitude Tota l Gain/loss Ilr:tm - Barometer mode IEIORI' - Memory mode e )) - Altimeter Alert ON MAX - Maximum memory D1 ... - Ascending .. - M i ni mum memory • - Descend i ng Elm mb - Barometer Graphic :: } Barometer Un" Display ft } Altimeter Unit m D2 J - : - : - : - : - : - . - . - . - . .. . ( _ ...

  • Pyle PAH1 - page 4

    WAKE UP AND SET YOUR COMPUTER - Press button A until all segment on or re-insta ll the battery A lt imeter Unit (Meterl Feet) Selection L Rig ht after all segment on, the Om" digit will start to flicker. 2. T o select m ( Meter) or ft ( Feet), press button B and then press button C to confirm. Barometer Unit (mb 1 hPa/ inHg ) Setting 1. Right ...

  • Pyle PAH1 - page 5

    THE BAROMETER • Press Button D to enter the Barometer Mode . Barometer and Weather States Adjustment 1. T o adjust the barometer and weather states. weather forecast funct i on can have a good Initialization. 2. Press Button D to Norma l Mode and then hold Button D again. the barometer digits wi ll start to flicker. 3. Press Button B to set and t ...

  • Pyle PAH1 - page 6

    THE BAROMETER Maximum and Minimum 1 . Press Button 0 to enter the Memory mode. 2. The memory of max i mum and minimum barometer wi ll be scro ll ed on the display automatica l ly. 3. To reset the memory, press and ho ld Button B . At the same t i me, the memory for the hygrometer and the thermometer wi ll be reset al so. 4. Press Button 0 to quit o ...

  • Pyle PAH1 - page 7

    Maximum and Minimum 1. Press Button A to enter the Memory mode . 2. T he memory of maximum and minimum a lti tude w ill be scro ll ed on the d i sp l ay automat i cally. 3. To reset the memory. press and hold Button B. At the same time. the memory for the hygrometer and the thermometer wi ll be r eset a l so . 4 . Press Button A to quit or left it ...

  • Pyle PAH1 - page 8

    The Al timeter Alarm 1. Press Button A to enter the Altimeter Al arm Mode. 2. To set the target a l t i tude for the A l arm , press and ho ld Button A unti l the digit starts to flicker. 3 . Press Button B to set the d i gits and then press Button A to conflrm . 4. Repeat Step 3 to set your desire digits . 5. After setting the target al ti tude, p ...

Manufacturer Pyle Category Sport Watch

Documents that we receive from a manufacturer of a Pyle PAH1 can be divided into several groups. They are, among others:
- Pyle technical drawings
- PAH1 manuals
- Pyle product data sheets
- information booklets
- or energy labels Pyle PAH1
All of them are important, but the most important information from the point of view of use of the device are in the user manual Pyle PAH1.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Pyle PAH1, service manual, brief instructions and user manuals Pyle PAH1. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Pyle PAH1.

Similar manuals

A complete manual for the device Pyle PAH1, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Pyle PAH1 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Pyle PAH1.

A complete Pyle manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Pyle PAH1 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Pyle PAH1, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Pyle PAH1, that we can find in the current document
3. Tips how to use the basic functions of the device Pyle PAH1 - which should help us in our first steps of using Pyle PAH1
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Pyle PAH1
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Pyle PAH1 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Pyle PAH1?

Use the form below

If you did not solve your problem by using a manual Pyle PAH1, ask a question using the form below. If a user had a similar problem with Pyle PAH1 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)