Manual Fluke PN 650454

12 pages 0.15 mb
Download

Go to site of 12

Summary
  • Fluke PN 650454 - page 1

    70/73 English Instru ction Sheet Page 1 ® 70/73 Series III Multimeter Instruction Sheet W Read First: Safety Information To ensure that the meter is us ed safely, fo llow these i nstructions: • Never use the m eter if the mete r or test lea ds look damaged. • Be sure the tes t leads and rot ary switc h are in the correc t position for t he des ...

  • Fluke PN 650454 - page 2

    70/73 English Instru ction Sheet Page 2 Input Jacks 300 mA 10A COM FUSED V ! Milliamps Amps Volts, Ohms, Diode Test Common Terminal 600V 70 70 hr2f.eps See Specific ations for overl oad protection. Pushbutton Use the pushb utton to eith er select a fix ed range or p ut the meter in the Automat ic Touch Hold  mode. Autorange The meter defa ults t ...

  • Fluke PN 650454 - page 3

    70/73 English Instru ction Sheet Page 3 Automatic Touch Hold  Mode W Warning To avoid electric shock, do not use the Touch Hold  to determine if a circ uit with high volt age is dead. The Touch Hold  mode will not capture unstable or noisy readings. The Touch H old  mode autom atically captures and d isplays stable readi ngs. Press R fo ...

  • Fluke PN 650454 - page 4

    70/73 English Instru ction Sheet Page 4 Standby If the meter is on but is inac tive for an ho ur (20 minutes i n diode test), the sc reen goes blank and display s selected ba r graph segments . To resume operat ion, turn the r otary switch or pr ess R . AC and DC Voltage ( K L m L ) + _ + _ V AC V DC + _ Volts AC Volts DC Millivolts DC V V V mV hr4 ...

  • Fluke PN 650454 - page 5

    70/73 English Instru ction Sheet Page 5 Diode Test ( G ) Forward Bias Single Beep Reverse Bias Shorted Open or Good Diode Bad Diode + _ + _ Bad Diode + _ Good Diode + _ hr7f.eps ...

  • Fluke PN 650454 - page 6

    70/73 English Instru ction Sheet Page 6 Continuity Test ( R ) + _ + _ hr5f.eps If continuity exists (res istance < 210 Ω ), the beeper s ounds continuous ly. The met er beeps twice if it is in th e Touch Hold  mode. Current ( ? A ) W Warning To avoid injury, do n ot attempt a current measurement if the open circuit voltage is above the rate ...

  • Fluke PN 650454 - page 7

    70/73 English Instru ction Sheet Page 7 Holster The snap-on h olster absorbs sho cks and protects the meter an d comes with a Flex -Stand  . To pro tect the front of the meter, put the meter fac e down in the holster. hr15f.eps Maintenanc e W Warning To avoid electr ic shock, remo ve the test lead s before opening t he case, and clos e the case ...

  • Fluke PN 650454 - page 8

    70/73 English Instru ction Sheet Page 8 Internal Fuse Test 300 mA Ω 5-8 Ω <0.5 OK OK 10 A OK 70 OK hr10f.eps Battery and Fuse Re placeme nt Note Before opening the case, mak e sure the tes t leads are removed and the rotary sw itch is turned to OFF. F1 F2 70 hr11f.eps ...

  • Fluke PN 650454 - page 9

    70/73 English Instru ction Sheet Page 9 Cleaning To clean the m eter, use a dam p cloth and m ild detergent; d o not use abrasiv es or solvents o n the meter. Service a nd Part s For servic e information in t he U.S.A. and C anada, call 1-8 00-44- FLUKE (1-800-44 3-5853), in Europe, 31 40 267 8200, from other countries, 1- 425-356-5500 . Item Descr ...

  • Fluke PN 650454 - page 10

    70/73 English Instru ction Sheet Page 10 Electromagnet ic Compatibility in RF field of 3 V/m on all functi ons exc ept M Ω Total a ccurac y = Spe cified ac curacy plus + 2.0% of range for all functi ons excep t: 320.0 mV range: tot al acc uracy = specified accuracy + 1.0% of range 320.0 Ω range: total accuracy = specifi ed accuracy + 8% of rang ...

  • Fluke PN 650454 - page 11

    70/73 English Instru ction Sheet Page 11 Function Range Accuracy 0L 3.200 V, 32.00 V, 320.0 V 600 V ± (0.3%+1) ± (0.4%+1) m L 320.0 mV ± (0.3%+1) K (45 to 500 Hz, 3.2V range. Other ranges 45 to 1 kHz) 3.200 V, 32.00 V, 320.0 V, 600 V ± (2%+2) ± (2%+2) 320.0 Ω 3200 Ω , 32.00 k Ω , 320.0 k Ω , 3.200 M Ω 32.00 M Ω ± (0.5%+2) ± (0.5% ...

  • Fluke PN 650454 - page 12

    70/73 English Instru ction Sheet Page 12 Overload pro tection for all functions and r anges: 600 V. Function Input Impedance (Nominal) L , m L , K >10 M Ω , <50 pF Common Mo de Rejection Rat io (1 k Ω Un balanced ) Normal Mode Rejection L , m L >120 dB at dc, 50 Hz, or 60 Hz >60 dB at 50 Hz or 60 Hz K >60 dB dc to 60 Hz Open Circ ...

Manufacturer Fluke Category Impact Driver

Documents that we receive from a manufacturer of a Fluke PN 650454 can be divided into several groups. They are, among others:
- Fluke technical drawings
- PN 650454 manuals
- Fluke product data sheets
- information booklets
- or energy labels Fluke PN 650454
All of them are important, but the most important information from the point of view of use of the device are in the user manual Fluke PN 650454.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Fluke PN 650454, service manual, brief instructions and user manuals Fluke PN 650454. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Fluke PN 650454.

Similar manuals

A complete manual for the device Fluke PN 650454, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Fluke PN 650454 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Fluke PN 650454.

A complete Fluke manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Fluke PN 650454 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Fluke PN 650454, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Fluke PN 650454, that we can find in the current document
3. Tips how to use the basic functions of the device Fluke PN 650454 - which should help us in our first steps of using Fluke PN 650454
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Fluke PN 650454
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Fluke PN 650454 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Fluke PN 650454?

Use the form below

If you did not solve your problem by using a manual Fluke PN 650454, ask a question using the form below. If a user had a similar problem with Fluke PN 650454 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)