    P33 Zero Clear ance Direct V ent Gas Fireplace Model P33-NG4 P33-LP4 Fuel T ype Natural Gas Propane Minimum Supply Pressure 5” W .C. (1.25 kPa) 12” W .C. (3.00 kPa) Manifold Pressure - High 3.8” W .C. (0.95 kPa) 1 1” W .C. (2.74 kPa) Manifold Pressure - Low 1.1” W .C. (0.27 kPa) 3.3” W .C. (0.82 kPa) Ori fi ce Size #44 DMS - 0-2000ft # ...

  • Regency 946-523/P - page 2

    Model P33-NG4 w/ Contemporary Faceplate P33-LP4 w/ Contemporary Faceplate Fuel T ype Natural Gas Propane Minimum Supply Pressure 5” W .C. (1.25 kPa) 12” W .C. (3.00 kPa) Manifold Pressure - High 3.8” W .C. (0.95 kPa) 1 1” W .C. (2.74 kPa) Manifold Pressure - Low 1.1” W .C. (0.27 kPa) 3.3” W .C. (0.82 kPa) Ori fi ce Size #47 DMS #56 DMS ...

  • Regency 946-523/P - page 3

    F r aming and Finishing 1) Determine the total thickness of facing material (e.g. drywall plus ceramic tiles) to allow the fi nished surface to be fl ush with the front of the unit. T otal facing thickness can vary from 1/2” (13mm) to 1-¼” (32mm) thick. 2) Frame in the enclosure for the unit with framing material. 3) For exterior walls, insu ...

  • Regency 946-523/P - page 4

    P33 Gas Fireplace Combustible Mantels with Contemporar y F aceplate Because of the extreme heat this fi replace emits, the mantel clearances are critical. Combustible mantel clearances from top of the louvers are shown in the diagram below . Mantel may be installed anywhere in the shaded area or higher . Mantel Le g Clearances with Contemporar y F ...

  • Regency 946-523/P - page 5

    6-7/8" (173mm) dia. Flue pipe 4" (102mm) dia. flue pipe W all Thimble (2 pc) T ermination Cap (Part# 946-523/P) AstroCap TM spring spacer FPI Direct V ent System (Flex) Horizontal T erminations Only This venting system, in combination with the P33 Direct V ent Gas Fireplace, have been tested and listed as a direct vent heater system by W ...

  • Regency 946-523/P - page 6

    Rigid Pipe V enting Horizontal or V ertical T erminations V enting Ar r angements - V er tical T er minations Rigid Pipe System (Propane & Natural Gas) The P33 is approved for a maximum 40 ft. straight vertical, with Rigid Pipe vent systems for Propane and Natural Gas. The lightly shaded area, 6 8 2 0 4 10 0 2 4 6 40 8 10 12 14 16 18 20 22 24 2 ...

  • Regency 946-523/P - page 7

    V er tical V enting with Two (2) 90° Elbo ws - Initial v er tical section. T wo 45° elbows = One 90° elbow Option V H V+ V1 Maximum total pipe: length, of all sections, must not exceed 30 feet. T otal horizontal sections must not exceed 8 feet. Minimum of 1 foot between 90° elbows is required. A) 1’ Min. 4’ Max. 2’ Min. B) 2’ Min. 5’ ...

  • Regency 946-523/P - page 8

    V enting Ar r angements - Horizontal T er minations This lightly shaded area of the diagram shows allowable combinations of vertical runs with horizontal terminations, using one 45° and one 90° elbow (two 45º elbows equal one 90° elbow). Note: Must use optional rigid pipe adapter (Part # 510-994) when using Rigid Pipe. • Maintain clearances t ...

  • Regency 946-523/P - page 9

    Horizontal V enting with Two (2) 90° Elbows - Initial v er tical section. T wo 45° elbows = One 90° elbow Option V H+ H1 Maximum total pipe: length, of all sections, must not exceed 30 feet. T otal horizontal sections must not exceed 8 feet. Minimum of 1 foot between 90° elbows is required. A) 1’ Min. 3’ Max. B) 2’ Min. 4’ Max. C) 3’ ...

  • Regency 946-523/P - page 10

    Flex Liner Exhaust Flue A maximum of two certified joiner kits may be used per length. #948-305 35 ft (1 1m) Air Intake Co-linear DV V ertical T ermination Cap # 946-529 Co-Linea Flex Adapter with Kit# 946-563 Outer Pipe with Kit# 946-563 Inner Pipe Adapter with Kit# 946-563 Rigid Pipe Adapter # 510-994 Pipe Length 45 Elbow o V er tical ter minatio ...

Manufacturer Regency Category Indoor Fireplace

Documents that we receive from a manufacturer of a Regency 946-523/P can be divided into several groups. They are, among others:
- Regency technical drawings
- 946-523/P manuals
- Regency product data sheets
- information booklets
- or energy labels Regency 946-523/P
All of them are important, but the most important information from the point of view of use of the device are in the user manual Regency 946-523/P.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Regency 946-523/P, service manual, brief instructions and user manuals Regency 946-523/P. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Regency 946-523/P.

Similar manuals

A complete manual for the device Regency 946-523/P, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Regency 946-523/P by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Regency 946-523/P.

A complete Regency manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Regency 946-523/P - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Regency 946-523/P, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Regency 946-523/P, that we can find in the current document
3. Tips how to use the basic functions of the device Regency 946-523/P - which should help us in our first steps of using Regency 946-523/P
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Regency 946-523/P
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Regency 946-523/P in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Regency 946-523/P?

Use the form below

If you did not solve your problem by using a manual Regency 946-523/P, ask a question using the form below. If a user had a similar problem with Regency 946-523/P it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)